• 제목/요약/키워드: Split Condenser

검색결과 10건 처리시간 0.026초

Control of Water Heat Recovery Chiller Using Split Condenser Templifier Application

  • Cho, Haeng-Muk;Mahmud, Iqbal
    • 에너지공학
    • /
    • 제18권1호
    • /
    • pp.17-21
    • /
    • 2009
  • By using the heat recovery of water-cooled chillers, it is possible to reduce the energy operating costs positively and at the same time it could fulfill the heating re-heat air conditioning system as well as the hot water requirements. Basically templifiers are designed to economically to turn the waste heat into useful heat. Waste heat is extracted from a fluid stream by cooling it in the evaporator, the compressor amplifies the temperature of the heat and the condenser delivers the heat to heating loads such as space heating, kitchens and domestic hot water. Design of higher water temperature requirements and split condenser heat recovery chiller system (using of templifiers) produced hotter condenser water approximately up to $60^{\circ}C$ and control the entire heat recovery system.

응축기 배열회수에 의한 흡수식 냉동기의 고효율화에 관한 연구 (A Study on the COP Improvement of Absorption Chillers by Recovering Heat from the Condenser)

  • 박찬우
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.738-744
    • /
    • 2006
  • In order to utilize the condensation heat of refrigerants in condenser on the absorption chiller system, the solution cooled condenser (SCC) was proposed using the weak solution of absorber as a cooling medium. The increase of COP with the increase of UA of the solution cooled condenser was approximately 0.009 in maximum with single effect one, and is about maximum 0.008 in occasion of double effect one with series flow compared to that without. In the case of heat exchanger, effectiveness is about 0.85, it's increments are 0.008 and 0.0072, respectively. And solution cooled condenser is more effective device in the single effect absorption system than double effect system for the principle of operation. On the other hand, as the solution split ratio increases when the value of UA is fixed, COP is increased and as the solution split ratio increases when the value of UA is fixed, COP is increased. If the flow rate of cooling water or the value of UA is reduced in order to increases the heat recovery of solution cooled condenser, heat recovery of solution cooled condenser is increased a little but COP is decreased as the system pressure is increased.

분리형 인버터 에어컨의 운전조건에 따른 성능 연구 (A study on the performance of a split system inverter air-conditioner at different operation conditions)

  • 김만회
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.113-121
    • /
    • 1998
  • The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.

Performance of A Three-Stage Condensation Heat Pump

  • Lee, Yoon-Hak;Jung, Dong-Soo;Kim, Chong-Bo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.55-68
    • /
    • 1999
  • In this study, computer simulation programs were developed for single-stage, two-stage, and three-stage condensation heat pumps and their performance with CFC11, HCFC123, HCFC141b was examined under the same external conditions. The results showed that the coefficient of performance(COP) of an optimized 'non-split type' three-stage condensation heat pump is 25-42% higher than that of a conventional single-stage heat pump. The increase in COP, however, differed among the fluids tested. The improvement in COP is largely due to the decrease in average LMTDs in condensers, which results in the decrease in thermodynamic irreversibility in heat exchange process. For the three-stage heat pump, the highest COP is achieved when the total condenser area is evenly distributed among the three condensers. For the two-stage heat pump, however, the optimum distribution of the total condenser area varies with an individual working fluid. For the three-stage system, 'splitting the condenser cooling water'for the use of intermediate and high pressure subcoolers helps increase the COP further. When the individual cooling water entering the intermediate and high pressure subcoolers is roughly 10% of the total condenser cooling water, the maximum COP is achieved showing roughly an 11% increase in COP as compared to that of the 'non-split type' heat pump.

  • PDF

콘덴서 구동형 단상유도전동기의 특성해석 및 효율개선을 위한 최적설계 (Characteristic Analysis and Optimum Design for Efficiency Improvement of the Single-Phase Permanent-Split Condenser Motor)

  • 임달호;홍정표;윤상백;손병욱;김기붕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.6-8
    • /
    • 1995
  • This paper describes the characteristic- analysis and tile optimum design of the single-phase permanent-split condenser motor. The equivalent circuit is constructed by the symmetrical coordinate method and proved its validity by comparing with the experimental data. Then, the numerical optimization technique is applied to improve the efficiency of the motor.

  • PDF

관순법을 이용한 공조기 사이클 시뮬레이션 (Air-conditioner cycle simulation using tube-by-tube method)

  • 윤백;박현연;유국철;김용찬
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.499-510
    • /
    • 1999
  • A computer program was developed for simulating performance(capacity, power consumption and etc.) of air-conditioners using compressor, fin-tube heat exchanger and capillary tube. The program consists of five modules, condenser, evaporator, compressor, capillary tube simulation modules and properties modules of refrigerant and moist air, The present program is focused on R22 only, however can be easily extended for other refrigerants such as R407C and R410A just by adding property modules. The compressor simulation module utilizes performance maps supplied by manufacturers-map-based model. The condenser and evaporator simulation modules are modeled using tube-by-tube method. Simulation results(capacity and power consumption) were compared with calorimeter test results of actual air-conditioners of window and split types, where more than 82% of the data lied within ${\pm}5$% of the predicted results.

  • PDF

사구 슬롯이 있는 콘덴서 구동형 단상 유도 전동기의 Radial force 해석 (Radial Force Analysis of a Single-Phase Permanent Split Condenser Induction Motor with skewed slots)

  • 장정환;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.241-243
    • /
    • 1996
  • This papar presents an analysing method of radial force densities acting on each stator tooth of an induction motor with skewed slots. Two-dimensional finite element method is used for electromagnetic Held analysis of an induction motor, and skew effects are considered by coupling several disks cut by planes perpendicular to the shaft. Radial force densities as a source of vibration are calculated along the surface elements of each stator tooth and its time harmonics are examined by discrete Fourier decomposition.

  • PDF

콘덴서 런 단상유도전동기의 설계적 고찰

  • 원종수
    • 전기의세계
    • /
    • 제31권2호
    • /
    • pp.132-140
    • /
    • 1982
  • Designing the capacitor-run motor for balanced operation is accompanied with the excessive capacitor value and low capacitor terminal voltage of condenser. As a solution for this problems, It was reported the design by equal volt-ampere method. The running characteristics of capacitor-run motor by this method due to the balancing point selection, however, has a room to be studied further. This paper deals with the determination of the winding ratio and capacitor value of a permarient-split capacitor motor by balanced operation and equal volt-ampere method at the different load points. The analysis of the running characteristics of a motor and its designing method also presented for both cases. It concluded that the running characteristics due to the equal volt-ampere operation are very close to the balanced operation.

  • PDF

가변주파수에 있어서 유도전동기특성의 도시산정법에 관한 연구 (A Study Of The Current-Diagram Method For Calculating Induction Motor Characteristics With Adjustable Frequency)

  • 박민호
    • 전기의세계
    • /
    • 제18권4호
    • /
    • pp.22-30
    • /
    • 1969
  • The development of the frequency convertors using semiconductors devices makes it possible to control the speed of A.C. motors easily. It is now economically feasible to provide them with power at adjustble frequency using silicon-controlled rectifier (or thyristor) inverters. In such a case, in order to operate an induction motor efficiently over a wide speed range, it must be supplied from a variable frecuency source of which frequency is adjustable over the speep range of the motor. It is desired to observe the changes in characteristics as primary current, torque-speed of induction moter etc. at any optional frequncy. Although the charactheristies can be obtained by means of the conventional methods they require very complicated precedures of calcuations. The Current Diagram Method in this paper suggests a new approach to simpler calcuations of the characteristics, using the motor constants at reference frequency. The conclusions of this study are summarized as follows: (1) The equations of stator current at adjusted frequency were derived to construct graphical chart and the current circle required for the Current Diagrm Method. (2) The radius, center of the current circle and the vector locus, the basis for calculating the characteristics, at any desired frequency could be easily determined with the aid of both the derived graphical chart and current circle at reference frequency. (3) The method was shown to be applicable to the various types of 3-phase induction motors and also dealt with its application to the split-phase, condenser motors.

  • PDF

가변주파수에 있어서 유도잔동기특성의 도식산정법에 관한 연구 제3보 (A Study of the Current-Diagram Method for Calculating Induction Motor Characteristics with Adjustable Frequency)

  • 박민호
    • 전기의세계
    • /
    • 제18권5호
    • /
    • pp.20-25
    • /
    • 1969
  • The development of the frequency convertors using semiconductors devices makes it possible to control the speed of A.C. motors easily. It is now economically feasible to provide them with power at adjustable frequency using silicon-controlled rectifier (or thyristor) inverters. In such a case, in order to operate an induction motor efficiently over a wide speed range, it must be supplied from a variable frequency source of which frequency is adjustable over the speed range of the motor. It is desired to observe the changes in characteristics as primary current, torque-speed of induction motor etc. at any optional frequency. Although the characteristics can be obtained by means of the conventional methods, they require very complicated precedures of calculations. The Current Diagram Method in this paper suggests a new approach to simpler calculations of the characteristics, using the motor constants at reference frequency. The conclusions of this study are summarized as follows: 1) The equations of stator current at adjusted frequency were derived to construct graphical chart and the current circle required for the Current Diagram Method. 2) The radius, center of the current circle and the vector locus, the basis for calculating the characteristics, at any desired frequency could be easily determined with the aid of both the derived graphical chart and current circle at reference frequency. 3) The method was shown to be applicable to the various types of 3-phase induction motors and also dealt with its application to the split-phase, condenser motors.

  • PDF