• 제목/요약/키워드: Splinted

검색결과 72건 처리시간 0.025초

치아종 제거후 시행한 자가치아이식술 (TOOTH TRANSPLANTATION AFTER SURGICAL REMOVAL OF ODONTOMA: A CASE REPORT)

  • 김종운;김수관;김수흥;정태영
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권3호
    • /
    • pp.244-247
    • /
    • 2001
  • 본 증례는 치아종제거후 병소하방에 존재하던 매복된 하악 좌측측절치를 원래 맹출되어야 할 부위로 자가치아이식 하였다. 수술후 12주에 치근흡수 소견이 관찰되어 근관치료가 시행되었다. 근관치료후 염증성흡수 소견은 중단되었으며 임상적으로 양호한 결과가 관찰되었다.

  • PDF

3급 부정교합의 초기치료 (Early Treatment of Class III Malocclusion)

  • 김가영;김진영;김병섭
    • 대한심미치과학회지
    • /
    • 제10권1호
    • /
    • pp.8-15
    • /
    • 2001
  • The Class III malocclusion classified in two types of Skeletal Class III and Pseudo Class III. In the case of the maxillary deficiency, the protraction H-G(facemask) with Bonded RPE can be used. For children with A-P and vertical maxillary deficiency, the preferred treatment is to move the maxilla into a more anterior and inferior position, which also increases its size as bone is added at the posterior and superior sutures. Successful forward repositioning of the maxilla can be accomplished before age 8. To resist tooth movement as much as possible, the maxillary teeth should be splinted together as a single unit. The maxillary appliance must have hooks for attachment to the facemask that are located in the canine-primary molar area above the occlusal plane. The facemask usually worn until a positive overjet of 2-5mm is achieved interincisally. Occipital chin cup is successful in those patients who can bring their incisors close to an edge-to-edge position when in centric relation. This treatment is particularly useful in patients who begin treatment with a short lower anterior facial height, as this type of treatment can lead to an increase in lower anterior facial height. If the pull of the chin cup is directed below the condyle, the force of the appliance may lead to a downward and backward rotation of the mandible.

  • PDF

Prevalence and risk factors of peri-implant mucositis and peri-implantitis after at least 7 years of loading

  • Ahn, Dae-Hee;Kim, Hyun-Joo;Joo, Ji-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • 제49권6호
    • /
    • pp.397-405
    • /
    • 2019
  • Purpose: This study examined the prevalence and risk factors of peri-implant disease after at least 7 years of dental implant loading. Methods: A total of 111 patients with 218 dental implants were treated. The follow-up period for all implants was at least 7 years. The patients' dental records were collected and risk factors of peri-implant disease were investigated through logistic regression analysis. Results: The overall implant survival rate was 95.87%, because 9 of the 218 implants failed. The prevalence of peri-implant mucositis and peri-implantitis was 39.7% and 16.7%, respectively. As risk factors, smoking and prosthetic splinting showed significant associations with peri-implantitis (P<0.05). Conclusions: Within the limits of this study, no significant correlations were found between any risk factors and peri-implant mucositis, but a significantly elevated risk of peri-implantitis was observed in patients who smoked or had splinted prostheses in 2 or more implants.

선균열과 상부 심빼기를 이용한 환경 친화적 터널발파공법 (A Tunnel Blasting Method Favorable to the Environment, which Utilizes Pre-splitting & an Upper Center Cut.)

  • 김일중;김영석;기경철
    • 화약ㆍ발파
    • /
    • 제20권2호
    • /
    • pp.7-19
    • /
    • 2002
  • The cut is placed high up in the section, the 1st sloping holes below the cut, and divided all the holes located below the 1st sloping holes into a certain area with longitudinal section, to lower pollution made from tunnel blasting. With the sequential blasting machine, after I first blasted holes around the cut holes by a pre-splitting method, blasted the cut area and the 1st sloping holes. The 1st and 2nd sloping holes divided areas are initiated gradually to free face upwards made by the cut. Especially, I pre-splinted contour holes previous blast the before sloping holes from the contours. The ground vibration from the earth surface just over the advance face decreased about 42.0% compare with the down blasting method under the condition of equal charge weight per delay. I controlled the crack and over break of the mother rock by pre-splitting contour holes before blast the first sloping holes from the contours. The peak values of noise and air blast by blasting decreased about 10dB more than the down blasting method. the noise and air blast diminished gradually as a round. The throw distance of the fly rock was decreased about 55%.

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study

  • Gedrimiene, Agne;Adaskevicius, Rimas;Rutkunas, Vygandas
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.271-279
    • /
    • 2019
  • PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and distal implant scan bodies ($P{\leq}.05$). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.

하악 소수 잔존치에서 텔레스코픽 의치를 이용한 수복 증례 (A case report on telescopic denture with a small number of residual teeth in mandible)

  • 오상민;이재훈
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.46-50
    • /
    • 2015
  • 하악의 잔존 치조제가 얇고 낮은 증례에서 국소의치를 이용한 수복은 잔존 치조제에서 적절한 전후방의 안정성 및 지지를 얻을 수 없어 환자에게 불편함을 주고 치조제에 과도한 교합력을 주게 된다. 또한 서로 멀리 떨어진 소수의 잔존치가 남았을 경우 스플린트하기 어렵고, 스플린트를 하지 않을 경우 고립 지대치가 되어 현명한 치료가 될 수 없다. 이와 같은 경우 텔레스코픽 시스템은 클래스프 의치에서 발생될 수 있는 치아에 작용하는 무리한 측방하중을 줄여주며, 안정적이고 확실한 유지력과 견고성을 갖는다는 장점이 있다. 본 증례는 전반적인 중등도의 치주염으로 인해 상악은 무치악, 하악은 소수 잔존치가 남은 상태에서, 상악은 총의치, 하악은 텔레스코픽 의치로 수복한 증례이다. 치료 계획 시 서로 멀리 떨어진 하악 소수 잔존치가 남고, 적절한 지지를 얻을 수 없는 치조제를 가져 클레스프 의치를 수복하더라도 많은 불편함과 어려움이 있을 것으로 판단되어, 텔레스코픽 의치로 수복하였다.

국소의치 유지장치의 설계변화에 따른 지지조직의 3차원적 유한요소법 응력분석 (A 3-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE SUPPORTING TISSUES OF REMOVABLE PARTIAL DENTURES WITH VARIOUS RETAINER DESIGNS)

  • 김기숙;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.413-439
    • /
    • 1995
  • The purpose of this study was to evaluate the stress distribution developed in the supporting structures by mandibular distal extension removable partial dentures with 2 different direct retainer designs and with or without indirect retainer and abutment splinting. The examined direct retainers on the second bicuspid abutment tooth were Akers clasp and RPA clasp, the indirect retainer was located on the mesial fossa of the first bicuspid, and the first and second bicuspid were splinted in case of tooth splinting. Total 8 cases were compared and analyzed with 3-dimensional finite element method. 150N were applied vertically on the artificial teeth of the removable partial denture, and then stress distribution patterns were analyzed and compared. The results were as follows : 1. The forces transmitted to the abutment tooth were primarily from the occlusal rests. 2. The abutment tooth was displaced distally when the force was applied. The compressive stress was observed at the distal root surface of the abutment tooth and the tensile stress, at the mesial root surface. 3. The denture base was displaced posteriorly and inferiorly when the force was applied. At the more distal portion of the denture base, the greater displacement was observed.And the anterior portion of the major connector was displaced superiorly. 4. The occlusal rest placed on the distal part of the abutment tooth tended to tip the tooth more posteriorly than did one on the mesial part of that tooth. 5. Severe superior displacement was observed at the anterior portion of the major connector in case of removable partial dentures without indirect retainer. 6. In case of tooth-splinting, the stress was distributed through all the root surface of both abuments. In case of no tooth-splinting, the stress was concentrated on the distal root surface of the primary abutment.

  • PDF

Strain gauge를 사용한 임플랜트 인상법의 정확도 비교 (A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE)

  • 한인택;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up

  • Alrabiah, Mohammed;Deeb, Modhi Al;Alsahhaf, Abdulaziz;AlFawaz, Yasser F.;Al-Aali, Khulud Abdulrahman;Vohra, Fahim;Abduljabbar, Tariq
    • Journal of Periodontal and Implant Science
    • /
    • 제50권2호
    • /
    • pp.97-105
    • /
    • 2020
  • Purpose: The present retrospective clinical study aimed to evaluate and compare the clinical and radiographic parameters, complications, and satisfaction in patients who received fixed prostheses supported by narrow-diameter implants (NDIs) in the anterior and posterior jaw. Methods: Patients aged ≥30 years who had NDI-supported fixed prostheses in the anterior or posterior region of either jaw for at least 2 years were included. Complications such as chipping of the crown; loosening or fracture of the screw, crown abutment, or implant; and loss of retention were recorded. Clinical peri-implant outcomes and crestal bone loss (CBL) were measured. A questionnaire was used to record responses regarding the aesthetics and function of the fixed restorations. Analysis of variance was used to assess the significance of between-group mean comparisons. The log-rank test was performed to analyze the influence of location and prosthesis type on technical complications. Results: Seventy-one patients (mean age: 39.6 years) provided informed consent with a mean follow-up duration of 53 months. Only bleeding on probing showed a statistically significant difference between NDIs in the anterior and posterior regions. The complication rate for NDIs in the posterior region was significantly higher than that for NDIs in the anterior region (P=0.041). For NDIs, CBL was significantly higher around splinted crowns than single crowns (P=0.022). Overall mean patient satisfaction was 10.34±3.65 on a visual analogue scale. Conclusions: NDIs in the anterior and posterior jaws functioned equally well in terms of periimplant soft and hard tissue health and offered acceptable patient satisfaction and reasonable complication rates.

Effects of soft tissue grafting prior to orthodontic treatment on preventing gingival recession in dogs

  • Song, Young Woo;Jung, Heekyu;Han, Seo Yeon;Paeng, Kyeong-Won;Kim, Myong Ji;Cha, Jae-Kook;Choi, Yoon Jeong;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • 제50권4호
    • /
    • pp.226-237
    • /
    • 2020
  • Purpose: This study was conducted to assess the efficacy of prophylactic gingival grafting in the mandibular anterior labial area for preventing orthodontically induced gingival recession. Methods: Eight mongrel dogs received gingival graft surgery at the first (I1) and third (I3) mandibular incisors on both sides based on the following group allocation: AT group (autogenous connective tissue graft on I1), AT-control group (contralateral side in the AT group), CM group (xenogeneic cross-linked collagen matrix graft on I3) and CM-control group (contralateral side in the CM group). At 4 weeks after surgery, 6 incisors were splinted and proclined for 4 weeks, followed by 16 weeks of retention. At 24 weeks after surgery, casts were made and compared with those made before surgery, and radiographic and histomorphometric analyses were performed. Results: Despite the proclination of the incisal tip (by approximately 3 mm), labial gingival recession did not occur. The labial gingiva was thicker in the AT group (1.85±0.50 mm vs. 1.76±0.45 mm, P>0.05) and CM group (1.90±0.33 mm vs. 1.79±0.20 mm, P>0.05) than in their respective control groups. Conclusions: The level of the labial gingival margin did not change following labial proclination of incisors in dogs. Both the AT and CM groups showed enhanced gingival thickness.