• 제목/요약/키워드: Spliced

검색결과 229건 처리시간 0.025초

다중모드 광섬유 융착형 침수 감지 센서 개발 (Development of submersion sensors using multi-mode fibers spliced with a fiber Bragg grating)

  • 손경락;계광현;심준환;조석제
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.925-931
    • /
    • 2009
  • This paper reports a preliminary experimental investigation and characterization of an optical fiber-based submersion sensor system for applications in water flooding and leakage. The sensor system comprises a multi-mode fiber spliced with fiber Bragg grating and an intensity-based interrogator. Submersion tests were conducted in water-air and Glycerin-air environments. By the refractive index of the fiber-probe surrounding materials, the reflectance and the detecting power level is determined. When the probe is dipped into the water, the optical output power dramatically decreases from -7.5dBm to -17.5dBm. But, the center of Bragg wavelength is not affected in spite of external material changes. Temporal response characteristics of the sensor system is investigated to verify the real-time reaction. When the probe is immersed into the liquid, there is no transition time.

주철근 겹침이음된 실물 비내진 원형 교각의 내진성능평가 (Seismic Performance Evaluation of Full-size Non-seismic Circular RC Bridge Piers with Longitudinal Steel Lap splice)

  • 정영수;이대형;고성현;이재훈
    • 콘크리트학회논문집
    • /
    • 제16권5호
    • /
    • pp.697-707
    • /
    • 2004
  • 내진설계편이 제정된 1992년 이전의 설계규정에 따라 설계$\cdot$시공된 교량은 내진상세가 적용되지 않아 지진에 취약할 것으로 예상된다. 특히, 주철근의 겹침이음은 교각의 상당한 내진성능저하를 야기하는 것으로 보고되고있다. 하지만, 이들 교량에 대한 내진성능평가 및 내진보강에 관한 연구는 아직 체계적으로 이루어지지 않고 있는 실정이다. 따라서, 이에 대한 대책마련이 시급한 것으로 사료된다. 본 연구에서는 이러한 비내진 교각의 내진성능을 평가하고자 형상비 4.0인 실물크기의 철근콘크리트 교각시험체를 제작하여 준정적실험을 수행하였다. 실험결과를 통하여 주철근 겹침이음된 비내진교각은 띠철근 형태와 상관없이 현행 도로교설계기준의 요구성능을 만족하지 못하는 것으로 조사되어 시급히 보강을 하여야 할 것으로 판단된다. 또한 주철근 겹침이음에 대한 내진규정의 보완이 요구된다.

RC 부재 휨 실험에 의한 GFRP 보강근의 이음길이 제안 (Splice Length of GFRP Rebars Based on Flexural Tests of Unconfined RC Members)

  • 최동욱;천성철;하상수
    • 콘크리트학회논문집
    • /
    • 제21권1호
    • /
    • pp.65-74
    • /
    • 2009
  • 이형철근의 부식이 우려되는 경우, GFRP 보강근의 사용이 사용될 수 있다. 이 연구에서는 GFRP 보강근으로 보강된 총 36개 보 및 일방향 슬래브의 휨 실험을 수행하였다. 4종의 GFRP 보강근을 실험에 사용하였고, 보강근 직경은 13 mm이었다. 대부분의 실험체의 보강근은 중앙부에서 겹침이음되었다. 모든 보 및 슬래브는 4점재하 되었으므로, 이음부는 균일한 모멘트를 받도록 계획하였다. 실험변수는 이음길이, 피복두께 및 보강근 간격이었다. 보수적으로 부착강도를 평가하기 위하여 이음부에는 스터럽을 사용하지 않았다. 실험결과 보강근과 콘크리트 간 발생한 부착응력을 비선형 단면해석을 통하여 결정하였다. 2변수 선형 회귀분석을 사용하여 평균부착강도의 예측식을 유도하였다. 5% 분위수 개념을 사용하여 이음길이 설계식을 제안하였다. 이 연구의 결과로 이론적인 이음길이 설계식이 제안되었으며 결과를 ACI 440 정착설계식과 비교하였다.

철근의 겹침이음을 고려한 철근콘크리트 교각의 내진성능평가 (Seismic Performance Evaluation of Reinforced Concrete Bridge Piers with Lap Splices)

  • 김태훈;박현용;김병석;신현목
    • 한국지진공학회논문집
    • /
    • 제7권3호
    • /
    • pp.31-38
    • /
    • 2003
  • 1992년 도로교 설계기준의 내진설계규정이 도입되기 이전에 건설된 대부분의 교각은 소성힌지구간에서 주철근의 겹침이음이 이루어졌다. 그러나 비탄성 반복하중하에서 겹침이음부의 갑작스런 취성파괴가 발생할 수 있다. 이 연구는 반복하중을 받는 주철근이 겹침이음된 철근콘크리트 교각의 비선형 이력거동과 연성능력을 해석적으로 파악하는데 그 목적이 있다. 이를 위해서 비선형 해석프로그램인 RCAHEST가 사용되었으며 겹침이음된 철근의 거동을 예측하기 위해서 겹침이음 철근요소를 개발하였다. 또한 겹침이음된 철근의 최대 철근응력과 슬립이 고려되었다. 이 연구에서는 주철근의 겹침이음을 갖는 철근콘트리트 교각의 내진성능평가를 위해 제안한 해석기법을 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.

수평 반복하중을 받는 비내진상세 RC 중공구형교각의 거동특성 (Behavior of Bellow Rectangular RC Piers without Seismic Detailing Subjected to Cyclic Lateral Load)

  • 김재관;김익현;임현우;이재호
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.263-272
    • /
    • 2003
  • 내진상세가 적용되지 않은 RC중공구형단면 교각의 지진 시 거동특성 및 내진성능을 파악하기 위하여 축소모델 실험을 수행하였다. 축소모델은 교각의 소성힌지영역내에 동일한 위치에서 모든 주철근이 겹침이음된 모델과 연속된 철근을 사용하여 겹침이음을 없앤 모델로 설계하였다. 실험은 축력이 재하된 상태에서 준정적 반복하중을 재하하였다. 실험결과 겸침이음모델은 주철근의 겹침이음부에서의 부착파괴가 발생하였지만 비교적 큰 연성거동을 나타냈으며 연속철근을 사용한 모델은 전형적인 휨파괴 특성과 매우 큰 연성거동을 보였다.

Molecular divergence of the fish somatomedins: the single family of insulin­like growth factor (IGF)-I and -II from the teleost, flounder

  • Kim Dong Soo;Kim Young Tae
    • Fisheries and Aquatic Sciences
    • /
    • 제1권2호
    • /
    • pp.227-231
    • /
    • 1998
  • The teleosts represent ancient real-bony vertebrates in phylogeny and resemble major genetic patterns to higher vertebrates. In the present study, we have defined the single family of insulin-like growth factors (IGFs) from flounder (Paralichthys olivaceus), compared to the prototype of IGFs observed in the Agnathan hagfish. In flounder, IGFs are clearly diverged into two major types including type I and II, and they are structurally similar by displaying a multidomain structure consisting of five functional regions as previously found in other vertebrates. However, flIGF-I appears to be more basic (pI 8.03) than the flIGF-II (pI 5.34) in the fully processed form for the B to D domain region. The flIGF-I seems to contain an evolutionary conserved Asn-linked glycosylation in E domain, which is not found in flIGF­II. The most interesting feature is that flIGF-II appeared to be structurally close to hagfish IGF in secondary structures, particularly in Band D domains. This could tell us an idea on the molecular divergence of IGFs from the Agnatha to teleosts during the vertebrate phylogeny. It also support, in part, a notion regarding on how IGF-II is appeared as more embryonic during development. Nonetheless, the biologically active B to D domain region of flIGF-II shows significant sequence homology of $65.6\%$ to flIGF-Is and contains the evolutionary conserved insulin-family signature, as well as a reserved recognition site (Lys) in D domain, necessary to generate proteolytic cleavage for E-peptide. A significant structural difference was found in E domain in which flIGF-I possesses two potential alternative splicing donor site at $Val^{17,\;24}$ of E domain. Therefore, it seems so far that IGF-I sorely produces spliced variants due to the spliced E-peptide moiety while IGF-II appears to be maintained in a single type during evolution. IGF-II, however, may be also possible to transcribe unidentified variants, depending on the physiological conditions of tissues in vertebrates in vivo.

  • PDF

낮은 압축력을 받는 철근콘크리트 기둥의 내진성능에 대한 띠철근 상세의 영향 (Effects of Tie Details on Seismic Performance of RC Columns Subjected to Low Compression Loads)

  • 김철구;박홍근;엄태성;김태완
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.195-205
    • /
    • 2015
  • Various non-seismic tie details are frequently used for one- and two-story small buildings because the seismic demand on their deformation capacities is not relatively significant. To evaluate the effects of the non-seismic tie details on the seismic performance of reinforced concrete columns, six square columns with a cross section of $400{\times}400mm$ and six rectangular columns with a cross section of $250{\times}640mm$ were tested. The anchorage details at both ends and spacing of tie hoops, along with the cross-sectional shape and the magnitude of axial load, were considered as the primary test parameters. Test results showed that square columns had higher stiffness and lower lateral deformation rather than rectangular columns. Both lap spliced tie and U-shaped tie provided comparable or improved seismic performance to $90^{\circ}$ hook tie in terms of maximum strength, ductility, and energy dissipation. The predicted curves with modeling parameters in ASCE41-13 were conservative for test results of lap spliced tie and U-shaped tie specimens since plastic behavior after flexural yielding could not be considered. For economical design, ASCE41-13 should be revised with various test results of tie details.

BIM 프로그램을 이용한 프리캐스트 콘크리트 전단벽의 모델링 (Modeling of Precast Concrete Shear Walls BIM Program)

  • 문주현;윤현섭;김종원;엄병호
    • 한국건축시공학회지
    • /
    • 제22권5호
    • /
    • pp.451-462
    • /
    • 2022
  • 이 연구의 목적은 다양한 접합상세를 갖는 프리캐스트 콘크리트(precast concrete, 이하 PC) 전단벽에 대한 BIM 모델링 절차를 정립하는 것이다. 그 결과 스케치업(SketchUp)의 프로그램과 컴포넌트 기능과 IFC(Industry foundation classes)파일 형식을 이용하여 BIM 프로그램에서 사용가능한 PC 전단벽 패밀리 라이브래리를 구축 할 수 있었다. 스플라이스 슬리브, 볼트 또는 용접접합공법을 이용한 PC 전단벽은 BIM 프로그램으로부터 배근된 철근들의 간섭여부와 콘크리트, 철근 및 철재 재료들의 물량을 정확히 평가할 수 있었다. 평가 결과 용접접합 공법을 이용한 PC 전단벽은 판재, 볼트 및 너트를 사용하였음에도 스플라이스 슬리브로 연결된 PC 전단벽에서 사용된 재료들의 전체물량, 경제성 및 환경영향성이 비슷한 수준에 있었다. 결과적으로 볼트 또는 용접접합 공법은 PC 전단벽에서 적용가능성이 높은 공법이며, 특히 시공성까지 고려한다면 스플라이스 슬리브 공법보다도 더 유용한 연결공법이 될 것으로 판단된다.

T형 교각의 겹침이음을 고려한 콘크리트 교량의 지진취약도 분석 (Seismic Fragility Analysis of Concrete Bridges Considering the Lap Splices of T-type Column)

  • 안효준;조백순;박주현;이종한
    • 대한토목학회논문집
    • /
    • 제43권3호
    • /
    • pp.287-295
    • /
    • 2023
  • 교량은 지진에 의해 붕괴가 일어나면 많은 수의 인명피해와 재산피해가 발생할 수 있어 정확한 지진거동 예측과 대비가 필요하다. 특히, 교각은 교량의 지진거동에 있어서 지배적인 역할을 한다. 또한, 교각의 겹침이음 길이 부족과 같은 설계적인 문제가 있다면 지진에 대한 위험성이 더욱 증대하게 된다. 본 연구에서는 교각에서 겹침이음 특성을 분석하기 위해, 겹침이음 길이가 부족한 교각의 수치해석 모델을 정의하고 실험데이터를 통해 검증하였다. 제시된 교각 모델을 일반적으로 사용되는 RC 슬래브 교량에 적용하였다. 교각의 비선형 정적해석을 수행하여 겹침이음에 따른 성능점 변화를 평가하였다. 또한, 지진취약도 곡선을 산정하여 교각의 겹침이음 길이에 따른 지진취약도 비교분석을 수행하였다.

GFRP 래핑에 의한 겹침이음된 교각의 내진보강 (Seismic Retrofit of GFRP Wrapping on the Lap-spliced Bridge Piers)

  • 염광수;권태규;이영호;황윤국
    • 대한토목학회논문집
    • /
    • 제26권2A호
    • /
    • pp.311-318
    • /
    • 2006
  • GFRP를 이용하여 종방향 철근의 겹침이음이 존재하는 원형RC 교각의 내진보강 성능을 파악하기 위해 5개의 실물규모 실험체를 제작하여 실험하였다. 대상교각은 1979년에 완공된 후 현재 공용중인 비내진 원형 RC교각으로 겹침이음된 종방향 철근의 부착파괴에 의한 급작스런 파괴가 예상된다. GFRP 래핑(Wrapping)으로 보강된 교각들의 내진성능은 매우 향상되었다. 하지만, 예상한 휨파괴는 발생하지 않았고, 종방향 철근은 항복하지 않았다. 보강된 교각의 파괴양상은 겹침이음된 종방향 철근의 지연된 부착파괴로 판단된다. 제안된 GFRP 보강설계법을 실험적으로 검증하였다.