• 제목/요약/키워드: Spliced

검색결과 229건 처리시간 0.023초

연결이음 접합된 섬유금속적층판의 하중전달 거동 연구 (Load Transfer Behaviors of the Splice-Jointed Fiber Metal Laminates)

  • 노희석;최원종;하민수;최흥섭
    • 대한기계학회논문집A
    • /
    • 제29권2호
    • /
    • pp.220-227
    • /
    • 2005
  • In this study, stress-displacement analytic solutions are obtained by a shear lag modeling method constructed for the spliced joint area with a splicing gap in the fiber metal laminate (FML). This gap can be empty or be filled with an adhesive material of elastic modulus $E_a$. Two splicing types are considered for spliced shear models, one for spliced in the center metal layer, the other for spliced in the outer metal layer. It is shown that from the viewpoint of the load transfer efficiency and the avoidability of disbond generation due to the shear and axial stresses at the interface between metal layer and composite layer of the gap-front in the spliced area, the center spliced type (k=2) is much preferable to the outer spliced type (k=1).

제안된 Spliced PSC-I형 거더의 휨거동에 관한 연구 (A Study on the Flexural Behavior of Proposed Spliced PSC-I Type Girder)

  • 심종성;오홍섭
    • 콘크리트학회논문집
    • /
    • 제12권5호
    • /
    • pp.13-23
    • /
    • 2000
  • In this study, an flexural test on half-scale spliced PSC-I girder was conducted to verify the efficiency of the long span spliced girder as suggested by the Korean Highway Design Specification. The experimental results showed that the specimens developed a complex failure mode due to flexural-compression and torsional stress. The cracking moment of each girder was higher the experiment than was calulated by the ACI and the ultimate strength were the almost same. To estimate the safety and the structural efficiency of the spliced girder, the proposed Yielding Resistance Index(YRI) and ductility index by American Concrete Institutes were used based on the energy concept. The proposed YRI defined the ratio of crack resisting energy and the total energy calculated from load-displacement relationship. Based on the analysis of YRI and ductility index, the flexural behavior of the spliced girder was found to be efficient. Through the experimental results, the structural behavior of proposed spliced PSC I-type girder for long span bridge was found to be more efficient than the exsisting PSC I-type girders.

부분 포스트텐션닝 방법에 의해 연속화된 교량의 주형단면 (Girder Section of Continuous Bridges Spliced by Partial Post-Tensioning)

  • 이환우;곽효경;송영용
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.43-50
    • /
    • 2000
  • In this paper, a new splicing method was applied to design the girder section of bridges with the span length of 25m, 30m, 35m, 40m and 45m. A U-type precast prestressed section was also determined for each bridge. Additionally, the sectional area, beam depth and Guyon's efficiency factor of the spliced U-type sections in each span were analyzed in comparison with the present I-type PSC bridges. As a result, in spite of an increase of 31%∼50% in the sectional areas compared with the I-type precast girders, the spliced U-type the beam depth of the spliced U-type girder was designed as 2,050 mm compared with the I-type precast girder of 2,600mm in a 40m span bridge. The sectional efficiency factors of the spliced U-type sections were analyzed as 0.76∼0.99. It shows that the spliced U-type sections ar of a superior structural efficiency in contrast to the average sectional efficiency factor of 0.66 value in the I-type girders.

휨연결재에 의해 횡방향으로 보강된 분절 프리스트레스트 거더의 정적거동에 관한 실험적 연구 (Experimental Study on Static Behavior of Laterally Strengthened Spliced Prestressed Concrete Girder using Bending Moment Connector)

  • 김재흥;김장호;김성배;이나현
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.287-295
    • /
    • 2010
  • 본 연구는 휨연결재와 횡방향 프리스트레스력으로 보강된 분절 PSC(Prestressed Concrete) 거더의 정적거동 성능을 검증하는데 목적이 있다. 정적거동 성능을 검증하기 위하여 4개의 분절거더와 1개의 일체거더를 제작하여 실험하였다. 분절거더와 일체거더는 동일 제원 및 재료를 적용하여 4.8 m 길이로 제작하여 실험하였다. 3개의 횡방향으로 보강된 분절거더의 정적거동 성능을 검증하기 위해 일체거더와 횡방향으로 보강되지 않은 분절거더가 기준이 되는 실험체로 실험을 수행하였다. 거더 중앙 경간에서 처짐을 측정하였으며 중앙 경간과 연결부에서 변형률을 측정하였다. 극한하중상태에서 횡방향으로 보강된 분절거더는 일체거더와 비교하여 극한강도가 동등이상의 성능을 나타내며 강성측면에서는 다소 불리하게 거동함을 알 수 있었다. 하지만, 횡방향으로 보강된 분절거더는 보강되지 않은 분절거더에 비하여 강도 및 강성측면에서 모두 우수한 성능을 나타내었다.

볼트 수직이음 PHC말뚝와 용접이음 PHC말뚝의 이음부 거동 비교 (Comparison of Splices between Bolts and Welding Spliced PHC Piles)

  • 김명학;최용규
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.93-103
    • /
    • 2018
  • 볼트 수직이음 PHC말뚝 및 용접이음 PHC말뚝에 대한 휨강도시험을 실시하여 각 이음 PHC말뚝의 성능을 비교 분석하였다. $200N{\cdot}m$이상의 토크치로 체결한 볼트 수직이음 PHC말뚝에서는 가장 낮은 하중단계인 20kN에서도 볼트 수직이음구에서 좌우로 꺾인 변형 양상(직선 v형 라인)이 나타났으며 PHC말뚝 본체는 완전한 직선 형태를 유지하고 있었으므로 볼트 수직이음 PHC말뚝은 말뚝의 가장 중요한 성능인 일체화 거동을 하지 않았다. 체결토크가 풀린 즉, $20N{\cdot}m$의 토크치로 체결한 볼트 수직이음 PHC말뚝은 각 하중 단계에서 이음부위에 대하여 양쪽으로 대칭된 직선 V형 상태의 변위 양상을 나타내고 있었다. 각 하중 단계에서 하중 제거 시 이음말뚝은 하중 재하 전의 상태로 돌아가지 않았으므로 탄성 재료 거동을 나타내지도 않았다. 재하단계에 따른 이음부 변위 및 재하 하중 제거 후의 잔류 변위, 이음 PHC말뚝의 파괴하중 및 3가지 기본 성능 등을 비교한 결과 볼트 수직이음 PHC말뚝의 이음 품질은 용접이음 PHC말뚝의 이음 품질에 크게 미달하였다. 따라서 $200N{\cdot}m$ 이상의 토크치로 체결한 볼트 수직이음 PHC말뚝이나 체결토크가 풀린 볼트 수직이음 PHC말뚝은 이음말뚝의 기본 성능에 크게 미달하는 것으로 나타났다.

Behavior of tension lap spliced sustainable concrete flexural members

  • Al-Azzawi, Adel A.;Daud, Raid A.;Daud, Sultan A.
    • Advances in concrete construction
    • /
    • 제9권1호
    • /
    • pp.83-92
    • /
    • 2020
  • The use of spliced reinforcing bars in sustainable concrete members to manage inadequate bars length is a common practical issue which is may be due to some limitations. The lap splicing means two bars overlapped in parallel with specified length called the splice length in order to provide the required bond between the two bars. The bond between sustainable concrete and spliced steel bars is another important issue. The normal strength sustainable concrete specimens of sizes 1700×150×150 mm with tension reinforcement lap spliced were selected according to testing device length limitations. These members were designed to fail in flexure in order to investigate the lap spliced tension bars effect. The selected lap spliced tension bars were of 10 mm size with smooth and deformed surfaces in order to investigate the surface nature accompanied with the splice nature. The sustainable concrete mechanical properties and mix workability were also studied. This study reveals that the effect of number of spliced bars on the response of beams reinforced with smooth bars is found to be more obvious than deformed one. Finite element modeling in three dimensions was carried out for the tested beams using ABAQUS software. A parametric study is carried out using finite elements on considering the following parameters, concrete compressive strength, load type and opening in cross section (hollow section) for weight reduction purposes.The laboratory and numerical results show good agreements in terms of ultimate load and deflection with an average difference of 10% and 15% in ultimate load and deflection respectively.

Behaviour of fiber reinforced concrete beams with spliced tension steel reinforcement

  • Safan, Mohamed A.
    • Structural Engineering and Mechanics
    • /
    • 제43권5호
    • /
    • pp.623-636
    • /
    • 2012
  • The aim of the current work is to describe the flexural behaviour of simply supported concrete beams with tension reinforcement spliced at mid-span. The parameters included in the study were the type of the concrete, the splice length and the configuration of the hooked splice. Fifteen beams were cast using an ordinary concrete mix and two fiber reinforced concrete mixes incorporating steel and polypropylene fibers. Each concrete mix was used to cast five beams with continuous, spliced and hooked spliced tension steel bars. A test beam was reinforced on the tension side with two 12 mm bars and the splice length was 20 and 40 times the bar diameter. The hooked bars were spliced along 20 times the bar diameter and provided with 45-degree and 90-degree hooks. The test results in terms of cracking and ultimate loads, cracking patterns, ductility, and failure modes are reported. The results demonstrated the consequences due to short splices and the improvement in the structural behaviour due to the use of hooks and the confinement provided by the steel and polypropylene fibers.

Poly A tail을 결핍한 Simian virus 40 spliced RNA의 세포내 분포 (The abundant presence of nonpolyadenylated SV40 late 19S spliced RNA in the nucleus of monkey cell)

  • 노정혜
    • 미생물학회지
    • /
    • 제26권2호
    • /
    • pp.106-112
    • /
    • 1988
  • We have examined the structures and cellular distributions of the SV40 late RNAs present in monkey cells at late times after infection. One particular RNA species, spliced at residue 373(373-RNA), was found to be as abundant as the major late 16S RNAs. This result was unexpected since previous reports showed that the molecular ratio of the 373-spliced 19S RNA to 16S RNA is approximately 0.1 among either cytoplasmic polyadenylated or polysomal viral RNAs. Both sedimentation and electrophoretic analysis indicated that the 373-RNA was approximately 16S to 19S in size. Therefore, it was not a splicing intermediate or the product of premature termination of transcription within the late leader region. Whereas most SV40 late 16S RNA is polyadenylated and located in the cytoplasm, the majority of 373-RNA was found to lack poly A, and be located in the nucleus.

  • PDF

휨연결재를 이용한 횡방향 프리스트레스를 도입한 분절거더의 실험적 성능평가 (Experimental Study on Lateral Prestressed Concrete of Spliced Girder using Flexural member Connector)

  • 김태균;박정천;김재흥;김성배;김장호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.13-14
    • /
    • 2010
  • 본 연구는 휨연결재와 횡방향 프레스트레스력으로 보강된 PSC(Prestressed Concrete) 분절 거더의 정적 거동 성능을 검증하는데 목적이 있다. 동일 제원과 재료를 적용하며 일체거더와 횡방향으로 보강되지 않은 분절거더와 3개의 횡방향으로 보강된 분절거더를 사용하여 중앙 경간의 처짐과 중앙 경간 및 연결부에서의 변형률을 측정하였다. 실험결과를 바탕으로 거더의 정적 휨성능을 평가 검증 하고 기존의 연속 거더와 횡구속이 안된 분절 거더의 성능을 비교 분석하였다.

  • PDF

확장판 선단부착 PHC말뚝 및 볼트 수직이음을 사용한 PHC말뚝의 시공 중 건전성 확인을 위한 동재하시험의 적용성 및 변형시공법 PHC말뚝들의 올바른 검증시험에 관한 연구 (Study on the Applicability of Dynamic Pile Load Test to Check Integrity during Installation of Extension Plate Attached PHC Piles and Bolts Spliced PHC Piles and the Correct Proof Test of the Transformed-installation PHC Piles)

  • 김명학;최용규
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.115-131
    • /
    • 2018
  • 현장 시험 부지에서 확장판 선단부착 PHC말뚝 및 볼트 수직이음 PHC말뚝에 대한 시험시공을 실시하고 시공중 건전성을 동재하시험으로 확인하고 시공 후 말뚝의 건전성을 직접 확인하였다. 그 결과를 분석하여 확장판 선단부착 PHC말뚝 및 볼트 수직이음 PHC말뚝의 시공 중 건전성을 동재하시험의 건전도지수(${\beta}$지수)로 평가할 수 있는지에 대하여 연구하였다. 이론적으로 말뚝 선단에 매우 인접하거나 선단끝단에서 발생하는 손상(특히 확장판 선단부착구 자체의 변형)은 시험기술의 특성상 건전도지수로 정확한 평가하는 데에는 한계가 있었다. 말뚝의 선단부에 바로 인접해서 발생하거나 말뚝선단 끝단에서의 손상을 PDA시험을 통하여 명확하게 평가하는 데에는 시험기술의 이론에 대한 고도의 지식과 경험이 요구되었다. 다른 볼트 수직이음구로 인하여 실질적인 1차원 파동전달이 용접이음에서와 다를 수 있다는 점, 타격에 의해 발생하는 응력파의 파장이 볼트 수직이음구 높이(약 100mm)보다 클 수 있다는 점, PDA 분석 기능 중 베타 프로세싱(Beta processing)이라는 기능 등이 매우 심도 있는 지식과 경험을 토대로 평가해야만 더욱 정밀한 판단이 이루어질 수 있다는 점 등을 종합적으로 고려할 때 일반적인 건전성 평가기술로 볼트 수직이음의 건전성을 평가하는 데에는 한계가 있었다.