• Title/Summary/Keyword: Spiral flow test

Search Result 24, Processing Time 0.025 seconds

Study on forced convective heat transfer in helically ceiled tubes (나선코일튜브내의 강제대류 열전달에 관한 연구)

  • 한규일;박종운;임태우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.3
    • /
    • pp.282-291
    • /
    • 1998
  • Heat transfer performance are studied for the turbulent flow of water in 3 smooth tube coils having ratios of coil to tube diameter of 16, 21 and 27, and a corrugated-coiled tube having a ratio of coil to tube diameter of 29, for Reynolds numbers from 8000 to 60000 and is also compared with the limited results available to data. The experiments are carried out for the fully developed turbulent flow of water in tube coils under the condition of uniform heat flux. This work is limited 0 tube coils of R/a between 10 and 30. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. The performance of coiled tube best transfer performance. The performance of coiled tube with a similar curvature ratio is better for a corrugated-coiled tube(R/a=17) than for a smooth coiled tube(R/a=16). An empirical relation which correlates most of the data within $\pm$25% was also developed. Test result shows that the Nusselt number is found to be affected by a secondary flow due to curvature.

  • PDF

The Effect of Spiral Balance Taping on Postoperative Sequelae in Breast Cancer : Case study (스파이랄 발란스 테이핑이 유방암 환자의 수술 후 후유증에 미치는 영향 : 사례연구)

  • Su-Ji Kang;Dae-Hee Lee;Cheul Jang;Back-Vin Lim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.37-47
    • /
    • 2024
  • Purpose : Cancer survivors often suffer from postoperative sequelae. the diagnosing and provision of manual therapy using spiral taping significantly improves the quality of life of cancer patients. The aim of this case study is to investigate the immediate effects of spiral taping on pain, range of motion (ROM), chemotherapy-induced peripheral neuropathy (CIPN), and lymphedema following breast cancer surgery. Methods : The taping techniques were performed as follows by spiral taping. The measurements were taken before, in the middle, and after taping using a mobile phone camera, tape measure, and a numerical rating score (NRS). The evaluation employed a single-group pre-post design based on a primitive experimental design. Results : Out of four patients, all four exhibited Reverse circle flow energy (RCFE), Passive cervical right (Rt) rotation test, anterior-posterior movement pattern, nerve type (+), cold energy (CE), sangcho acupuncture point, blood clot, hwal point. Comparing before and after treatment, almost all values were reduced to zero after treatment in terms of pain complaints. The lack of range of motion (ROM) caused by the shortened tissue after surgery did not increase. The range of motion (ROM) lost due to pain returned to normal. The circumference of lymphedema did not show a tendency. The symptoms of CIPN improved. Conclusion : There was a significant change in joint range of motion, with pain decreasing, but there were structural limitations in the tissue due to total resection, and the chemotherapy-induced peripheral neuropathy scale. It was effectively treated surgical site pain, axillary membrane syndrome-induced pain, and unexplained pain. While there was a treatment effect for lymphedema in the evaluation of circumference values, there was no significant change in circumference. There was a significant effect on chemotherapy-induced peripheral neuropathy, particularly in treating numbness in the feet, which is a side effect of TC anticancer drugs. This case study found that spiral balance taping provides a rapid therapeutic effect for most side effects in patients who have undergone total breast cancer resection. However, the generalization is limited due to the small sample size, and further research is needed to determine the extent to which the effects of one treatment are maintained.

The Fluidity and Hardness of the Recycled Thermoplastic Elastomer in the Injection Molding process (엘라스토머 재생재의 사출성형시 유동성과 경도)

  • Noh, Byeong-Su;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • In recent, recycling of plastic material has became a major issue due to the landfills and environmental problem. This study investigated fluidity and hardness of thermoplastic vulcanizate(TPV), which is used for automobile component parts such as weather strip in order to replace ethylene propylene rubber (EPDM). So, using the spiral flow test mold, we conducted an experiment on fluidity and hardness of TPV according to injection molding conditions. As results of injection molding experiment, the recycled TPV's flow length was a little bit longer than virgin TPV and the hardness was decreased in case of using the recycled resin. Also, we investigated the morphology study by SEM photo.

  • PDF

Establishment of DNN and Decoder models to predict fluid dynamic characteristics of biomimetic three-dimensional wavy wings (DNN과 Decoder 모델 구축을 통한 생체모방 3차원 파형 익형의 유체역학적 특성 예측)

  • Minki Kim;Hyun Sik Yoon;Janghoon Seo;Min Il Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.1
    • /
    • pp.49-60
    • /
    • 2024
  • The purpose of this study establishes the deep neural network (DNN) and Decoder models to predict the flow and thermal fields of three-dimensional wavy wings as a passive flow control. The wide ranges of the wavy geometric parameters of wave amplitude and wave number are considered for the various the angles of attack and the aspect ratios of a wing. The huge dataset for training and test of the deep learning models are generated using computational fluid dynamics (CFD). The DNN and Decoder models exhibit quantitatively accurate predictions for aerodynamic coefficients and Nusselt numbers, also qualitative pressure, limiting streamlines, and Nusselt number distributions on the surface. Particularly, Decoder model regenerates the important flow features of tiny vortices in the valleys, which makes a delay of the stall. Also, the spiral vortical formation is realized by the Decoder model, which enhances the lift.

Condensation and evaporation heat transfer characteristics of HFC-134a in a horizontal smooth and a micro-finned tube (수평 평활관과 마이크로핀 관내에서 HFC-134a의 응축 및 증발열전달 특성)

  • Lee, Sang-Cheon;Park, Byeong-Deok;Han, Un-Hyeok;Lee, Jae-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1725-1734
    • /
    • 1996
  • Experimental condensation and evaporation heat transfer coefficients were measured in a horizontal smooth tube and a horizontal micro-finned tube with HFC-134a. The test sections are straight, horizontal tubes with have a 9.52mm outside diameter and about 5000mm long. The micro-finned tube had 60 fins with a height of 0.12mm and a spiral angle of 25.deg.. The condensation test section was a double-pipe type with counter flow configuration. The evaporation test section employed an electic heating method. Enhancement factors which is defined as a ratio of the heat transfer coefficient for micro-finned tube to that for smooth tube, varied from 1.3 to 1.6(mass flux:110~190kg/m$^{2}$s) for condensation and 1.2 to 1.5 (mass flux:70~160kg/m$^{2}$s) for evaporation. The experimental data of condensation and evaporation heat transfer coefficients were compared to several empirical correlations. Based on these comparisons, modified correlations of the condensation and evaporation heat transfer coefficient for both smooth and micro-finned tubes were proposed.

An Outlook on the Draft-Tube-Surge Study

  • Nishi, Michihiro;Liu, Shuhong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.1
    • /
    • pp.33-48
    • /
    • 2013
  • If large pressure fluctuation is observed in the draft tube of a Francis turbine at part-load operation, we have generally called it draft-tube-surge. As occurrence of this phenomenon seriously affects the limit of turbine operating range, extensive studies on the surge have been made since proposal of surge-frequency criterion given by Rheingans. According to the literature survey of related topics in recent IAHR symposiums on hydraulic machinery and systems, in which state-of-the-art contributions were mainly presented, a certain review of them may be desirable for an outlook on the future studies in this research field. Thus, in this review paper, the authors' previous attempts for the last three decades to challenge the following topics: a rational method for component test of a draft tube, nature of spiral vortex rope and its behavior in a draft tube and cavitation characteristics of pressure fluctuations, are introduced together with other related contributions, expecting that more useful and significant studies will be accomplished in the future.

A Study about Micro Mold for Polymer Injection (고분자소재 성형용 마이크로 금형에 관한 연구)

  • Heo Y. M.;Shin K. H.;Yoon G. S.;Jung W. C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.271-275
    • /
    • 2004
  • In recent industry, according to pursuit the miniaturization and high-precision of machine part with development of new technology as IT and BT, the development of mold manufacturing technology for mass production is accompanied. This study proposes the design of micro mold-base, predicts the error of product through estimating transformation of injection process using FEM. Therefore the mold-base which is suitable for micro injection proposed in this study. Finally, the error of feature is analyzed by measuring the manufactured micro mold-base.

  • PDF

A study on the intraoral factor related to oral malodor (구취발생에 관여하는 구강내부요인에 관한 연구)

  • Jung, Mi-Ae;Lee, Eun-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.119-131
    • /
    • 2008
  • This study was peformed in order to find out the relationship between the causing factors and the production of each gas 01 oral malodor, to contribute the oral malodor control at dental clinic as well as to establish the effective application of malodor control project for public oral health program 127 patients from 20 to 40 years old who had been visited for preventive dental cares were participated for the study. Such items as caries status, periodontal status, salivary flow, viscosity, pH. Snyder test, plaque deposit and tongue plaque were checked through the oral examination in order to find out the contributing factors Hydrogen sulfide, Methyl mercaptan, Di-methyl sulfide and Ammonia gas components were checked with Oral-Chroma and Attain, the oral malodor check units. Not only the corelation coefficiencies but also the multi-way variance analysis were calculated between each causing factor and each component of oral malodor gases to estimate the contributing factors of the oral malodor. 1. There was no relationship between the caries status and each component pf the oral malodor such as sulfur compound or Ammonia, both in laboratory test and VAS test (pF0.05). It revealed negative relationship between Hydrogen sulfide and FT(rM-0.1904. pE0.05) as well as the VAS and FT (rM-0.210. pE0.05). S0, it was estimated that the less oral malador was recognized when caries state changed to filled state in Hydrogen sulfide laboratory test or VAS test 2. High relationship was showed between salivary flow and Hydrogen sulfide (rM-0.183, pM0.039), Methyl mercaptan(rM-0.234, p-0.008). Dimethyl sulfide(rM-0.234, pM0.008) and Ammonia(-0.361. pM0.001) gas(pE0.05). 3. There was a high relationship between M-PHP(Modified-Patient Hygiene Performance Index) and tong plaque all kinds of sulfide(rM0.249. pM0.005). Ammonia gas component(rM0.232, pM0.009). 4. It was found that considerable relationship was appeared between the periodontal status and Ammonia gas (rM0.274, pM0.002), so, it should be needed to control Ammonia. Such dental Cares as the prevention or early treatment of periodontal disease and the accelerating the salivary flow as well as reducing the amounts and activities of filament or spiral typed oral micro-organism were recommended for adults, not only for dental care program at the dental clinics but also for public health programs, in order to promote the oral health and quality of file for individual and community peoples.

  • PDF

The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire (터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구)

  • Yang, Sang-Ho;Choi, Young-Seok;Kim, Jung-Yup;Kim, Nam-Goo;Kim, Kyung-Yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.

Constraints on Cosmological Models from the Large-Scale Velocity Field

  • Doh, Jean-Gyung;Park, Changbom-;Chun, Mun-Suk
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.04a
    • /
    • pp.16-16
    • /
    • 1993
  • The Cosmic Mach number M is the ratio of the bulk flow velocity of the galaxrvelocity field on some scale R to the unall scale velocity dispersion within refcions of scale R. Because M is the ratio of two velocities, it is inn-dimansionat and the Here, independent of the amplitude of the power specHim and of the biasplnmeter in the linear theory. We have measured the Mach rnlmber for two observational samples: a spiral galaxy sample(AHM) of Aaronson and hiscoBlaborators with absolute distances measured by the infrared Ttillr-Fisher relatioa and an elliptical galaxy sample(EGALS) of Faber or 0, with distances determined by the relation. The effective depths distances of galaxies from the Local Group of these samples are 1639 km/s and 2862 e/s, respectivelr. The Machnumbers from these observed peculiar velocity Selds He fund as M=0.95 for AHMand M=0.59 for EGALS. We comPBre these calculated Mach numbers with thosefrom meck surweys drawn fuom three cosnulogical medels: the stand8rd biased nh=0.5 CDM modet an open CDM rrudel with gh=0.2, and a medd with thepower-law power specelm P(k)-k-1 and n=1. The Mach rnlmber test can give robust constraints on these cosmelogical nudels whose power spectra have very different shapes at large scales.

  • PDF