• Title/Summary/Keyword: Spiral Tube

Search Result 88, Processing Time 0.021 seconds

DESIGN OF AXIAL FLOW HYDRAULIC TURBINE USING CFD APPROACH: STUDY OF TURBINE PERFORMANCE ACCORDING TO THE NUMBER OF RUNNER BLADE (CFD를 이용한 축류 유체 터빈 설계: 블레이드 수에 따른 성능 연구)

  • Lim, H.S.;Kim, S.W.;Baek, J.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.561-566
    • /
    • 2011
  • In this paper, 1-D design of axial flow hydraulic turbine including runner blades, spiral casing with distributors(guide vanes and stay vane), and draft tube was conducted and then 3-D flow analysis was carried out using CFX-12.1. The results of 3 runners showed that with an increase in the number of blades, the flow rate and the power of the turbine system increased. On the other hand. the runner loss was not directly connected with the number of blades. As a result, proper blade number could be selected and more than 100kW small hydraulic turbine could be designed.

  • PDF

Oxygen Transfer Efficiencies of A Single Spiral Roll Aeration System by the Off-gas Method (Off-gas Analyzer를 이용한 하수처리장 단일선회류 방식 포기시스템 산소전달 효율의 평가)

  • Park, Bo Hwa;Ko, Kwang Baik;Park, Jae Han;Lim, Se Ho;Shin, Dong Rok;Yun, Hye Jung;Lee, Ji Young;Moon, Tae Hoon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.534-539
    • /
    • 2006
  • The supply of oxygen for aeration is the largest energy consumer at activated sludge wastewater treatment plants. Replacement of less efficient aeration systems with fine pore aeration devices can save up to 50 percent of aeration energy costs. The purpose of this study was the diagnosis and evaluation of a domestic wastewater aeration system by the off-gas method which had been studied by US EPA and ASCE. For this study, an off-gas analyzer and its hood were made to collect off-gas. Also, a vacuum pump was connected to the analyzer to make suction of off-gas. Experiments were conducted at a domestic activated sludge wastewater treatment plant which had a single spiral roll aeration system installed with P.E tube diffuser. Data on OTE(f), SOTE(pw), OUR, and air flow rate were obtained from these experiments. In case of replacing an aeration system, it is recommended that it should be replaced with perforated membrane disc or ceramic disc fine bubble diffusers installed in a full floor coverage or grid pattern.

Experimental Analysis of Large Size Concrete-Filled Glass Fiber Reinforced Composite Piles Subjected to the Flexural Compression (대구경 콘크리트 충전 복합소재 파일의 휨-압축 거동에 대한 실험적 분석)

  • Lee, Sung Woo;Choi, Sokhwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.519-529
    • /
    • 2009
  • Fiber reinforced composite materials have various advantages in mechanical and chemical aspects. Not only high fatigue and chemical resistance, but also high specific strength and stiffness are attained, and therefore, damping characteristics are beneficial to marine piles. Since piles used for marine structures are subjected to compression and bending as well, detailed research is necessary. Current study examine the mechanical behavior under flexural and/or compressive loads using concrete filled fiber reinforced plastic composite piles, which include large size diameter. 25 pile specimens which have various size of diameters and lengths were fabricated using hand lay-up or filament winding method to see the effect of fabrication method. The inner diameters of test specimens ranged from 165 mm to 600 mm, and the lengths of test specimens ranged from 1,350 mm to 8,000 mm. The strengths of the fill-in concrete were 27 and 40 MPa. Fiber volumes used in circumferential and axial directions are varied in order to see the difference. For some tubes, spiral inner grooves were fabricated to reduce shear deformation between concrete and tube. It was observed that the piles made using filament winding method showed higher flexural stiffness than those made using hand lay-up. The flexural stiffness of piles decreases from the early loading stage, and this phenomenon does not disappear even when the inner spiral grooves were introduced. It means that the relative shear deformation between the concrete and tube wasn't able to be removed.

Analysis of the Gas Feed Distribution at the Gas Sweetening Absorber Using CFD (CFD를 활용한 산성가스 처리공정용 흡수탑 가스분산성 향상 연구)

  • Lee, Ji Hyun;Shim, Sung-Bo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.314-320
    • /
    • 2014
  • Regarding the design of the gas sweetening absorber, the gas distribution analysis for the increase of the sour gas removal and reduction of the tower height is very important research topics. Recently, regarding the $CO_2$ capture technology which is a promising option for the reduction of the greenhouse gas (GHG), the need for the gas distribution improvement is increased as the gas treating capacity increases. In this paper, we have investigated the sour gas distribution in the absorber using CFD (Computational Fluid Dynamics) based on 10 MW post-combustion $CO_2$ capture plant installed in Boryeong power station, Korea Midland Power company. For this purpose, we suggested the three possible technology options (splash plate, spiral gas line and U-tube) for the gas distribution enhancement and compared the effect of the each cases. The result showed that the U-tube installed in the absorber increase the gas distribution about 30% compared to the base case, while the delta P increasement was about 10%. From these results, it was found that the U-tube installation is an effective technology option for the gas distribution enhancement in the gas sweetening absorber.

Changes in CT Number and Noise Level according to Pitch in Spiral Image Acquisition (나선형영상획득에서 Pitch에 따른 CT 감약계수와 잡음의 변화)

  • Kang, SungJin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.981-989
    • /
    • 2020
  • In this study, a self-made customized phantom was used to quantitatively measure the change in CT number and noise according to the change of pitch. In order to acquire an image using the phantom, the inside of the phantom was filled with sterile distilled water. Inside the glass tube, a solution obtained by diluting the ratio of normal saline and contrast medium to 100%(NS), 400:1, 200:1, 100:1, 50:1, respectively, was placed and imaged. At this time, the pitch was divided into steps of 0, 0.35, 0.7, 1.05, and 1.4 for each dilution ratio of the solution and imaged, respectively. One-way ANOVA analysis were performed to verify whether the mean of the CT number and noise values measured in all ROIs by dilution ratio showed a significant difference according to the change in pitch. As a result of the experiment, there was no statistically significant difference in the change of the CT number according to the change in the pitch for each dilution ratio, but the noise value tended to increase with the increase of the pitch, and showed a statistically significant difference. In the spiral image acquisition of CT, noise can be changed to a significant level depending on the pitch. Therefore, it will be necessary to set the quality evaluation items and criteria for CT images using the spiral image acquisition method.

A Study on the Heat Transfer Performances in Sintered Pipes (소결 코팅 파이프의 열전달 성능에 관한 연구)

  • Park, Ki-Ho;Lee, Ki-Woo;Kim, Seong-Il;Jeong, Dae-Heon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.436-439
    • /
    • 2008
  • This paper is to research the heat transfer performance of the sintered pipe. Recently, oil prices is to be 127 $ per barrel, we expect higher costs this summer. We promote alternative fuels, after oil and gasoline prices reached record highs. The governments have made efforts to avoid future crisis by continuing the move toward renewable energy and energy saving. In this paper, we have fabricated a sintered pipe, the heat transfer performance of sintered pipe is achieved experimentally. The pipe is copper tube of outer diameter of 15.88 mm, the length of the pipe is 800 mm. Based on the experimental results, it is shown the overall heat transfer coefficient of sintered pipe is increased as compared with that of a straight pipe, is equal as compared with that of a spiral pipe. The overall heat transfer coefficient was $0.075{\sim}0.09\;kW/^{\circ}C$

  • PDF

On the Analytical Model of Automotive Steering Hoses Containing Tuner and Its Practical Application (튜너 내장 자동차 조향호스의 해석 모델과 실용적 응용)

  • Lee, J.C.;Oh, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • This study presents an analytical model of an automotive steering hose containing tuner(flexible spiral metal tube) to reduce the ripple pressure induced by steering vane pump. The double-wall side branch composed in a steering hose containing tuner was analogically considered as a filter in a conduit. Specialized test equipment was manufactured for the estimation of speed of sound in a conduit and measurement of amplitude ratio between the propagated ripple pressures of inlet and outlet of the steering hose. Experimental data of entire frequency ranges can be obtained through the test once in short time. The results of three points' measurement method and cross-correlation method to estimate the speeds of sound in a hose, tuner, and side branch respectively reveal that cross-correlation method can be used practically. The results of simulation and experiment were so close, especially in the range of engine idling speed, that the proposed analytical model in this study was validated. Sensitivity analyses and experiments show that longer tuner is preferable, and that the positive-positive composition of the steering hoses containing tuner is superior to others to attenuate ripple pressure.

  • PDF

The Experimental Study on the Heat Transfer Characteristics (가스보일러 코일형 열교환기의 열전달 특성에 관한 실험적 연구)

  • Hong, S.H.;Kim, Y.K.;Kim, I.G.;Kim, D.C.;Lee, C.E.;Yim, C.S.
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.57-66
    • /
    • 1997
  • The performance of gas-fired boilers were experimentally investigated. The heat exchanger used for the experiments consisted of circular tube with longitudinal fins for the gas side and a spiral coil for the water side. The burner was located at the top of the heat exchanger, and the burned gas flowed down to the exit. The experiments carried out for different water flow rates, the heat capacities of the boiler and the number of baffle. The thermal efficiency of the upward flow was higher than that of the downward flow of the water in the heat exchanger. As the boiler capacity increased, the thermal efficiency decreased. As the number of the baffles increase, the thermal efficiency increased and the increasing rate of the efficiency decreased. The gas-side overall heat transfer coefficient was independent of the flow rate of the water. The effect of the number of the baffles on the heat transfer coefficient was greater than that of the boiler capacity.

  • PDF

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Development of Abutment-H pile Connection for Large Lateral Displacements of Integral Abutment Bridges (일체식 교대 교량의 대횡변위를 위한 교대와 H형 말뚝 연결부의 개발)

  • Kim, Woo Seok;Lee, Jaeha;Park, Taehyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.309-318
    • /
    • 2013
  • Abutment-to-pile connection in an integral abutment bridge is vulnerable to lateral displacement induced by thermal movement of the superstructure. However, previous researches have merely focused on the connection. In order to improve the performance of the connection, new abutment-to-pile connection designs were proposed based on quasi-static nonlinear finite element model. The reinforcement detail specified in PennDOT DM4 and HSS tube were barely effective in controlling crack growing but spiral rebar effectively performed to delay crack growth as well as absorbing energy capacity. However, it was found that delaying cracking and strengthening the connection also caused the high lateral load in superstructures. Consequently, shape of HP pile were modified to introduce plastic hinge of the HP pile for reducing the lateral load in superstructures. Connections with modified HP pile significantly prevented crack propagations under the lateral displacement.