• Title/Summary/Keyword: Spiral Duct

Search Result 13, Processing Time 0.025 seconds

Air Flow Prediction and Experiment by T-Method According to Duct Layout on House Ventilation System (주택환기시스템의 덕트 Layout에 따른 T-Method의 풍량 예측 및 실험)

  • Joo, Sung-Yong;Yee, Jurng-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.523-528
    • /
    • 2008
  • The accurate distribution of flow rate has been a very important part to control the air change rate since introduction of house ventilation system. An inappropriate selection of fan due to incorrect prediction of pressure loss in duct brings energy loss. In the previous study the pressure loss of general spiral duct was measured and database was constructed for finding correct loss factors in fitting upper stream. The purpose of this study is to compare and investigate the error range of flow rate by applying T-Method to bilateral symmetry and asymmetry layout of duct. The results of this study are as following. It is demanded to decide accurate size under duct design for house ventilation system. Because the small amount of Flow rate was considered at that time. The error range was 3.17% on case1 and 3.52% on case2. The error range difference was 0.35%.

  • PDF

Studies on the Semen Collection of Wild Duck (Anas platyhychis platylyachos) (청둥오리의 정액채취에 관한 연구)

  • 최인경;송해범
    • Korean Journal of Poultry Science
    • /
    • v.25 no.3
    • /
    • pp.113-118
    • /
    • 1998
  • These experiments were conducted to develope the artificial insemination methods of wild duct (Anas platyhychis platylyachos) . The characteristics of erect phallus and semen collected by the abdominal massage method were investigated in wild duck. The erection and withdrawal time of phallus were 50.70${\pm}$18.66 and 92.58${\pm}$51.95 sec. , respectively, in wild duck. The length, long and short diameter of erect phallus were 3.98${\pm}$0.49crn, 1.53${\pm}$0.15cm and 1.05${\pm}$0.04 cm, respectively, and the spiral grooves of erect phallus were 4 in wild duck. The volume of semen, concentration of spermatozoa and total sperm of an ejaculate were 0.18${\pm}$0.06 ml, 2.84${\pm}$0.03 x 10 9 /ml and 0.52${\pm}$0.21 x 10 cells, respectively, in wild duck. The motility of sperm and pH of semen were 49.06${\pm}$14. 35 and 7.6${\pm}$0.14 in wild duck.

  • PDF

Stall and Counter-measure for Large Size Axial-Flow Fan (대형축류팬의 실속과 대책)

  • Shim, Eui-Bo
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.70-77
    • /
    • 1998
  • The rise in pressure across the impeller blade of an axial flow fan depends on the angle of attack. At a low back pressure, the air volume will be large and the angle of attack is small. The gradual increase of the back pressure approached stall zone which is not stationary but travels blade to blade passage. In consequence, a region occurs around these blades with large vibration in the flow. To avoid these stall operation, the stall detector in the axial flow fans has been designed to detect stalling condition with a manometer or differential pressure switch by electric mechanism.

  • PDF

Study on the Performance Improvement of Roof Fan Used for Local Exhaust System Installed in Apartment (공동주택의 국소배기용 루프팬 성능개선에 관한 연구)

  • Kwon, Yong-Il;Jeong, Yeol-Wha;Ahn, Jung-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.136-141
    • /
    • 2012
  • Performance improvement of local exhaust system used in toilet and cooking place are main concern in a field of ventilation. In Korea, There are many high riser residential apartments in recent years. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depends on stack effect. This study investigates on the performance improvement of terminal device, roof fan, of vertical spiral duct used in high riser residential apartments. This paper focuses mainly on the effect of accessories, number or shape of blades, composed of roof fan with function of exhaust air volume of toilet and cooking place. Roof fan with 10 blades is observed at optimum exhaust performance in this study.

Development and Application of an Open Water Test System for Azimuth Thrusters (아지무스 추진기 단독시험 시스템 개발 및 적용)

  • Lee, Young-Jin;Rhyu, Seong-Sun;Seo, Jong-Soo;Lew, Jae-Moon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.4
    • /
    • pp.199-205
    • /
    • 2013
  • To research and develop an azimuth thruster, the new type of open water test dynamometers to measure thrust, torque, total thrust and duct force are designed and manufactured by Samsung Ship Model Basin(SSMB). A compact servomotor to be accurately controlled is connected to precise spiral bevel gear through shafting system combined by couplings and main shafts. The dynamometers have shown excellent linearity and repeatability for all components of forces and a torque. Also, the open water tests have been successfully performed to show the performance of the system. In near future, it is expected that the device can be used for the study of scale effects and development of azimuth thrusters.

Removal Effect of Acid Gases by Reactant Mixer and Distributor of Bag Filter in Dry Scrubbing with NaHCO3 (중탄산나트륨 건식공정에서 반응제 혼합 장치 및 백필터 분배장치에 의한 산성가스 제거 영향)

  • Lee, Young-Man;Kwak, Yeon-Ho;Bae, Woo-Keun;Kwon, Ki-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.402-409
    • /
    • 2009
  • Sodium bicarbonate ($NaHCO_3$) was used as a reactant for the removal of acid gases from a waste incinerator. The removal efficiencies of HCl and $SO_x$ were tested with a reactant mixing apparatus and a distributor installed at the bag filter inlet. It was shown that the stoichiometric ratio of $NaHCO_3$ to the acid gases which allows a removal of over 90% for both HCl and $SO_2$ was about 1.2. When a reactant mixing apparatus was installed on the duct, the removal efficiencies of HCl and $SO_2$ at the end of the duct were increased by approximately 1.5 and 3 times respectively, compared to when the apparatus was not installed. At the end of the bag filter, the removal efficiencies of the both were as high as 98% with a stoichiometric ratio of 1.35. Installing a reactant mixing apparatus on the duct and a distributor at the entrance of the bag filter and using $NaHCO_3$ as a reactant helped overcome the problem of low removal efficiencies of acid gases by dry scrubbing.

Ultrastructural Study on the Poison Secreting Organ of the Spider (거미류 독액(毒液) 분필기관(分泌器官)의 미세구조(微細構造)에 관한 연구(硏究))

  • Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.22 no.1
    • /
    • pp.128-142
    • /
    • 1992
  • Ultrastructure of the poison secreting organ in the spiders, Agelena limbata Thorell and Nephila clavata L. Koch were studied using scanning and transmission electron microscopes. The venom glands located its secretory sac portion in cephalothorax and excretory duct in the fang of chelicera are one pair of simple alveolar glands composed of three kinds of basic tissues-outer spiral musculature, middle myoepithelium and inner glandular epithelium. The muscle cells of the venom gland junctioned with the motor nerve endings at neuromuscular contact area are composed of smooth muscle fibers, whereas the myoepithelial cells between the musculature and inner glandular epithelium have compact collagenous fibers within the cytoplasm. The glandular epithelial cells which arranged along the concentrical location are subdivided into basal light cells and apical dark cells according to electron densities of their cytoplasms.

  • PDF

Experimental Study of 3-Dimensional Rapid Prototyping by Laser Chemical Vapor Deposition (레이저 화학증착을 이용한 3차원 쾌속조형에 관한 실험적 연구)

  • Ryu Jae Eun;Lee Young Lim
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.14-21
    • /
    • 2005
  • Laser chemical vapor deposition can be an effective technique for a rapid prototyping with ceramic materials, in particular. The objective of the study is to fabricate several 3-dimensional objects by stacking multi-layers as well as to find out some basic aspects of a rapid prototyping with laser chemical vapor deposition such as deposition characteristics with traversing speed of the laser, possible problems in stacking multi-layers etc. The limit speed of the laser that can grow a tilted SiC rod was found in this study, and laser directing writing that occurs over the limit speed was also investigated. Finally, a zigzag-shaped rod, a spiral-shaped rod, a wall and a square duct were successfully fabricated with laser chemical vapor deposition of tetramethylsilane

Intraductal ultrasonography for biliary strictures

  • Young Koog Cheon
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.164-168
    • /
    • 2023
  • When diagnosing the nature of biliary strictures, it is sometimes difficult to perform non-invasive methods such as ultrasound, spiral computed imaging, magnetic resonance imaging, or endoscopic ultrasonography. Thus, treatment decisions are usually based on biopsy results. However, brush cytology or biopsy, which is widely used for biliary stenosis, has limitations owing to its low sensitivity and negative predictive value for malignancy. Currently, the most accurate method is bile duct tissue biopsy under direct cholangioscopy. On the other hand, intraductal ultrasonography administered under the guidance of a guidewire has the advantages of easy administration and being less invasive, allowing for adequate examination of the biliary tract and surrounding organs. This review discusses the usefulness and drawbacks of intraductal ultrasonography for biliary strictures.