• 제목/요약/키워드: Spiral Computed

검색결과 63건 처리시간 0.024초

사면의 3차원 안정해석에 관한 연구 (A Study on the Three-Dimensional Stability Analysis of the Slope)

  • 김영수;백영식;서인석
    • 한국지반공학회지:지반
    • /
    • 제7권4호
    • /
    • pp.89-98
    • /
    • 1991
  • This paper presents the three-dimensional stability analysis of the homogeneous, isotropic soil Slopes. Rotational slides are assumed with a cylindroid central part terminated with log-spiral curved ends. The ratio of threeiimensional minimum factor of safety to two 4imensional case is examined and factor of safety changes are showed for the ratio of cylinder length to slope height. On touch babes the following conclusions may be made 1. Factors of safety computed for 3-D geometry differ considerablely from ordir,arty 2-D factor of. safety. Sinoe Fn 1 Fa2 exceeds unity, threeiimensional effects tend to increase the factor of safety. 2. A,B LIU increase, the value of Fb3/ Fs2 decreases. 3. The ratio of Fr/Fs2 appears to be very sensitive to c and values.

  • PDF

컴퓨터단층촬영(CT) 기술 동향 (Computed Tomography Technology)

  • 이정원;이수열;유동훈
    • 전자통신동향분석
    • /
    • 제25권4호
    • /
    • pp.60-68
    • /
    • 2010
  • CT는 종래의 엑스선 촬영 기법으로 얻은 인체 내부의 투영 데이터를 컴퓨터로 재구성하여 단층영상을 만들어 내는 기술이다. 1972년 최초의 상용화 CT가 개발된 이후로 촬영 속도 개선의 측면에서 비약적인 발전을 이루었다. 겐트리 구동 방식의 발전과 Spiral CT, MDCT 기술의 도입이 스캔 시간 단축에 큰 역할을 하였다. 특히 MDCT의 개발로 다양한 임상적 활용이 가능해졌다. 한편 O-arm CT 기술은 CT를 공간적 제약에서 벗어나게 하였다. 이는 CT가 수술실 현장에서 활용될 수 있다는 임상적 의미를 가진다. O-arm CT는 즉석에서 활용되어야 하므로 촬영과 동시에 영상이 실시간으로 재구성되는 것도 중요하다. 최근에 도입되기 시작한 GPU 프로그래밍 기술은 고성능 GPU 하드웨어의 발전을 등에 업고 실시간 CT 재구성을 가능하게 할 것으로 보인다.

은하계(銀河系)의 질량분포(質量分布) 모형(模型)-III (A Model of the Mass Distribution of the Galaxy-III)

  • 유경노;강용희
    • 천문학회지
    • /
    • 제8권1호
    • /
    • pp.3-9
    • /
    • 1975
  • Densities of the three constituent spheroids of the same eccentricity as our earlier model of the Galaxy are assumed to be given by an analytical form of $_{{\rho}i}$(r)=$k_ie^{-m_ir^u{_i}}$, where $k_i,\;m_i$, and ${\alpha}i$ are obtained by comparing with the results of the previous model. Using three values of $_{{\rho}i}$(r) the galactic rotation curve, mass of each spheroid and the whole Galaxy are calculated, and the three dimensional density distribution in the Galaxy is also obtained. The calculated rotation curve of the model Galaxy is in good agreement with the observed curve, and the shape of the cross section of the model Galaxy given by the computed density is very similar to the inferred shape of the spiral galaxies.

  • PDF

글루타르알데하이드에 담근 자가심막을 이용한 전방기관성형술 -1례 보고- (Anterior Tracheoplasty Using Glutaraldehyde-Soaked Autologous Pericardium -One Case Report-)

  • 이석열;송철민;장원호;박형주;이철세;이길노
    • Journal of Chest Surgery
    • /
    • 제35권6호
    • /
    • pp.487-490
    • /
    • 2002
  • 65세 여자 환자가 호흡곤란을 주소로 내원하였다. 환자는 과거력상 뇌수술과 기관절개술후 반복되는 흡인으로 인하여 기관전환수술을 시행 받았다. 응급 3차원 나선형 기관단층 촬영술에서 하부기관의 협착이 나타났다. 수술은 정중 흉골절개술을 통하여 글루타르알데하이드에 담근 심막을 이용한 전방기관성형술을 실시하여 좋은 결과를 보았다. 저자들은 이를 치험 하였기에 보고하는 바이다.

Customized Cranioplasty Implants Using Three-Dimensional Printers and Polymethyl-Methacrylate Casting

  • Kim, Bum-Joon;Hong, Ki-Sun;Park, Kyung-Jae;Park, Dong-Hyuk;Chung, Yong-Gu;Kang, Shin-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권6호
    • /
    • pp.541-546
    • /
    • 2012
  • Objective : The prefabrication of customized cranioplastic implants has been introduced to overcome the difficulties of intra-operative implant molding. The authors present a new technique, which consists of the prefabrication of implant molds using three-dimensional (3D) printers and polymethyl-methacrylate (PMMA) casting. Methods : A total of 16 patients with large skull defects (>100 $cm^2$) underwent cranioplasty between November 2009 and April 2011. For unilateral cranial defects, 3D images of the skull were obtained from preoperative axial 1-mm spiral computed tomography (CT) scans. The image of the implant was generated by a digital subtraction mirror-imaging process using the normal side of the cranium as a model. For bilateral cranial defects, precraniectomy routine spiral CT scan data were merged with postcraniectomy 3D CT images following a smoothing process. Prefabrication of the mold was performed by the 3D printer. Intraoperatively, the PMMA implant was created with the prefabricated mold, and fit into the cranial defect. Results : The median operation time was $184.36{\pm}26.07$ minutes. Postoperative CT scans showed excellent restoration of the symmetrical contours and curvature of the cranium in all cases. The median follow-up period was 23 months (range, 14-28 months). Postoperative infection was developed in one case (6.2%) who had an open wound defect previously. Conclusion : Customized cranioplasty PMMA implants using 3D printer may be a useful technique for the reconstruction of various cranial defects.

고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의 (Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement)

  • 송광선;신계철;용석중;류정선;강신구;김정주;성기준
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권4호
    • /
    • pp.519-526
    • /
    • 1996
  • 연구배경 : 양성종양과 악성종양은 혈관분포의 차이와 임파선 발달이 차이로 혈관조영시 조영증강의 정도가 다르다. 이에 연구자는 고립성 폐결절 환자에서 SRCT을 시행하여 조영증강의 정도를 관찰하였다. 방법 : 대상은 1995년에 원주의과대학 호흡기내과에 내원하여 고립성 폐결절로 진단받고 조직검사를 시행받은 환자 16예였다. 고립성 폐결절 환자에서 조영제 주입후 SRCT를 시행하여 조영증강의 정도를 45초, 2분, 5분에 측정하여, 조직학적 및 임상적으로 진단된 양성결절 8예와 수술후 악성결절로 확진된 8예 사이에 그 차이를 관찰하였다. 결과 : 1. 대상 환자의 평균연령은 52세로, 남녀는 11:5 예였다. 2. 질환별로는 결핵성 결절이 8예, 선암이 6예, 상피세포암이 2예였다. 3. 폐결절의 평균 크기는 $2.86{\pm}1.11cm$(1.8-5cm)이었으며 양성결절은 $2.98{\pm}1.4cm$, 악성결절은 $2.76{\pm}0.84cm$으로 차이는 없었다(p=0.75). 조영제 투여전 평균 CT numbed (hounsfield unit)는 $36.8{\pm}17.2$ HU 이며, 양성 결절 $38.1{\pm}23$ HU 과 악성결절 $35.1{\pm}15.3$ HU 으로 두군 간의 차이는 없었다(p=0.52). 조영제 투여 시작후 45초에 조영증강(조영전과 비교한)은 평균 $12.1{\pm}1.3$ HU 이며, 양성결절 $6.22{\pm}10$ HU 과 악성결절 $19.6{\pm}7.9$ HU으로 두군간의 유의한 차이가 있었다 (p=0.008). 조영제 투여 시작후 2분의 조영증강은 평균 $21.1{\pm}20.8$ HU 이며, 양성 결절 $6.75{\pm}15$ HU 과 악성결절 $34.0{\pm}19.2$ HU 으로 악성결절에서 더 높은 경향을 보였다 (p=0.007). 조영제 투여 시작후 5분의 조영증강은 평균 $21.8{\pm}1.9.7$ HU 이며, 양성 결절 $7.75{\pm}17$ HU 과 악성결절 $34.0{\pm}15.4$ HU 으로 악성결절에서 더 높았다(p=0.011). 조영증강의 시판별 변화는 조영제 투여전과 투여시작후 45초, 2분, 5분의 CT number는 악성결절의 경우는 $35.1{\pm}15.3$ HU, $54.7{\pm}15.6$ HU, $69.1{\pm}24.2$ HU, $69.1{\pm}16.4$ HU 으로 계속적인 증가를 유지하였으나 양성 결절에서는 각각 $38.1{\pm}23$ HU, $44.3{\pm}34$ HU, $44.8{\pm}24$ HU, $44.8{\pm}32$ HU 으로 큰 변화가 없었다. 4. 조영증강과 다른 요인간의 상관관계 : 결절의 크기와 조영증강 사이의 상관관계는 없었으며(r=0.21, p=0.43) 환자의 나이와 조영증강 사이에도 상관관계는 없었다(r=0.21, p=0.42). 결론 : 이상의 결과로 고립성 폐결절에서 SRCT상 시간에 따른 조영증가는 악성결절에서 단시간내 더 현저하여 양성결절과 악성결절을 감별하는데 도움이 될 것으로 생각된다.

  • PDF

Clinical Study of Tumor Angiogenesis and Perfusion Imaging Using Multi-slice Spiral Computed Tomography for Breast Cancer

  • Xu, Na;Lei, Zhen;Li, Xiao-Long;Zhang, Jun;Li, Chen;Feng, Guo-Quan;Li, Di-Nuo;Liu, Jing-Yi;Wei, Qiang;Bian, Ting-Ting;Zou, Tian-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권1호
    • /
    • pp.429-433
    • /
    • 2013
  • Objectives: To explore the correlation between multi-slice spiral CT (MSCT) perfusion parameters and the expression of vascular endothelial growth factor (VEGF) as well as matrix metalloproteinase-2 (MMP-2) in breast cancer. Methods: Forty five breast cancer patients and 16 patients with benign breast tumor, both confirmed by pathology examination, were enrolled. All underwent MSCT perfusion imaging to obtain perfusion maps and data for parameters including blood flow (BF), blood volume (BV) and permeability surface (PS). Cancer patients did not receive treatment prior to surgery. The expression of VEGF and MMP-2 were examined with both immunohistochemistry and Western blotting. Results: The levels of VEGF and MMP-2 by immunohistochemistry were significantly higher in the breast cancer group (P < 0.01) than the benign tumor group. Relative OD values from Western blotting were also higher in cancer cases (P < 0.05). Similarly, the mean MSCT perfusion parameters (BF, BV, PS) were significantly higher in the breast cancer group (P < 0.01), BF and BV positively correlating with VEGF expression (r = 0.878 and 0.809 respectively, P < 0.01); PS and VEGF and MMP-2 expression were also positively correlated (r= 0.860, 0.786 respectively, P < 0.01). Conclusion: There is a correlation between breast cancer MSCT perfusion parameters and VEGF andMMP-2 expression, which might be useful for detection of breast lesions, qualitative diagnosis of breast cancer, and evaluation of breast cancer treatment.

나선형영상획득에서 Pitch에 따른 CT 감약계수와 잡음의 변화 (Changes in CT Number and Noise Level according to Pitch in Spiral Image Acquisition)

  • 강성진
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.981-989
    • /
    • 2020
  • 본 연구는 Pitch의 변화에 따른 CT 감약계수(CT Number)와 잡음(Noise)의 변화를 정량적으로 측정하고자 자체 제작한 맞춤형 팬텀(Customized Phantom)을 사용하였다. 팬텀을 이용한 영상의 획득을 위해 팬텀 내부는 멸균증류수로 가득 채웠다. 유리관 내부에는 생리식염수와 조영제의 비율을 각각 생리식염수 100%, 400:1, 200:1, 100:1, 50:1로 희석한 용액을 담은 후 영상화하였고, 이때 용액의 희석비율별로 pitch를 0, 0.35, 0.7, 1.05, 1.4의 단계로 나누어 각각 영상화하였다. 희석비율별로 모든 ROI에서 측정한 CT number와 noise 값의 평균이 pitch의 변화에 따라 유의한 차이를 보이는지 검증하고자 일원 배치 분산분석(One-way ANOVA Analysis)과 사후검정을 시행하였다. 실험 결과 각 희석비율별 pitch의 변화에 대한 CT number의 변화는 통계적으로 유의한 차이가 없었지만, noise 값은 pitch의 증가에 따라 증가하는 경향을 보였으며, 통계적으로도 유의한 차이를 보이는 것으로 나타났다. 나선형 영상획득 방식은 pitch에 따라 noise가 유의한 수준으로 달라질 수 있다. 따라서 나선형 영상획득 방식을 적용한 CT 영상의 화질평가 항목과 기준을 설정할 필요가 있을 것이다.

자발성 뇌지주막하 출혈 환자에서 뇌동맥류 검출에 대한 고식적 혈관조영술과 3차원 전산화 단층 혈관조영술의 비교 (Detection of Aneurysms in Patients with Spontaneous Subarachnoid Hemorrhage : A Comparison of Three-dimensional Computed Tomographic Angiography and Conventional Angiography)

  • 이경수;강창구;허륭;이상훈;정의화
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권6호
    • /
    • pp.711-716
    • /
    • 2001
  • Objectives : Three-dimensional computed tomographic angiography(3D-CTA) is recently developed diagnostic imaging modality. We have studied this noninvasive method for possible role in replacing conventional angiography( CA) in the detection of aneurysms of the circle of Willis in patients with subarachnoid hemorrahge(SAH). Methods : We studied retrospectively, the 100 patients with SAH or unruptured aneurysms admitted to our hospital from October 1997 to December 1998. Among there, 85 patients underwent CTA, 82 patients underwent CA and 67 patients underwent both of CTA and CA. 3D-CTA was obtained using maximum intensity projection(MIP) and shaded-surface display(SSD) reconstruction. Results : Total 107 aneurysms were detected in 92 patients, and 64 aneurysms were detected in 67 patients underwent both CTA and CA. In five cases of those 67 cases, aneurysms were detected by CA but not by 3D-CTA. The detection rate of aneurysms(91.8%) and the detection rate of parent artery in cases of anterior communicating artery aneurysms(86.9%) with total 3D-CTA were relatively compatible with that of CA. But 3D-CTA was not enough in detection of posterior communicating artery aneurysms, internal carotid artery aneurysms as well as small sized aneurysm(<3mm). Conclusion : We consider CTA is valuable in as a screening test for cerebral aneurysm and follow-up test. And it is also valuable in early surgery for patients with aneurysmal rebleeding because of simple, quick, non-invasive method.

  • PDF

뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구 (Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권3호
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.