• Title/Summary/Keyword: Spiral Computed

Search Result 64, Processing Time 0.036 seconds

Characteristic Analysis using Equivalent Magnetic Circuit Network Method for Permanent Magnet Excited Transverse Flux Linear Motor with Spiral Core in a Mover (스파이럴 이동자 코어를 가지는 영구자석여자 횡자속 선형전동기의 등가자기회로망법을 이용한 특성해석)

  • Lee, Ji-Young;Kim, Ji-Won;Woo, Byung-Chul;Kang, Do-Hyun;Hoang, Trung Kien;Kim, Kwang-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.794_795
    • /
    • 2009
  • This paper presents an analysis method for a permanent magnet excited Transverse Flux Linear Motor (TFLM) with spiral core in a mover. The spiral core is used as mover core in order to make 3-dimensional magnetic flux path at the TFLM which has 3-dimensional magnetic flux flow. Magnetic field is analyzed by three-dimensional Equivalent Magnetic Circuit Network (EMCN) method. And an imaginary part, 'flux barrier,' is introduced to consider the spiral core characteristic. The computed thrust forces is compared to the measured results to show the effect of presented analysis method.

  • PDF

Improved Reconstruction Algorithm for Spiral Scan Fast MR Imaging with DC offset Correction (DC offset을 보정한 나선 주사 초고속 자기공명영상의 재구성 알고리즘)

  • 안창범;김휴정
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.243-250
    • /
    • 1998
  • Reconstruction aspects of spiral scan imaging for ultra fast magnetic resonance imagine(MRI) have been investigated with polar and rectangular coordinates-based reconstruction. For the reconstruction of the spiral scan imaging, acquired data in spiral trjectory should be converted to polar or rectangular grids, where interpolation techniques are used. Various reconstruction algorithms for spiral scan imaging are tested, and reconstructed image qualities are compared with computed phantom. An improved reconstruction algorithm with dc-offset correction in projection domain is proposed, which provides the best reconstructed image quality from the simulation. Image artifact with existing algorithms is completely removed with the proposed method.

  • PDF

Comparative Evaluations of Magnetic Resonance Image, Spiral Computed Tomography and Ultrasound in the Diasnosis of Experimental Diaphragmatic Rupture in the Rabbit (토끼의 횡격막 파열 진단에 있어서 자기공명영상, 나선형전산화단층촬영 및 초음파의 가치 비교)

  • 김학희;정승은;이배영;최병길;신경섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.154-161
    • /
    • 1997
  • Purpose: Traumatic rupture of the diaphragm is not easy to diagnose and often delayed. Delayed diagnosis of diaphragmatic rupture accompanied by higher chances of strangulation of herniated viscera which may result in higher morbility and mortality. The purpose of this study was to evaluate diagnostic accuracy of spiral CT, MRI and US for the diagnosis of diaphragmatic rupture in an animal model. Materials and Methods: Small, medium, and large sized transabdominal diaphragmatic ruptures were surgically made in experimental rabbits and then followed up with spiral CT, MR!, and US at 1 day, 3 day, and 1 week after operation. Results: US was superior to MR! or spiral CT in diagnosis of diaphragmatic rupture(P(0.05). The sensitivity and specificity were 94.4% and 92.9% for US, 54.0% and 85.7% for MRI, and 46.0% and 78.6% for spiral CT, respectively. The size of laceration was not related to diagnostic sensitivity in US. Sensitivity of MRI and spiral CT increased as the size of laceration were larger, but no statistical significance was present(P>0.05). All experimental animals developed pleural effusion or hemothorax one day after operation. In acute phase, US and MRI were more sensitive than spiral CT in detecting diaphragmatic rupture. Spiral CT was more sensitive than US and MRI in delayed phase but without statistical significance(P>0.05). In the experimental rabbits with accompanying visceral hernia through the diaphragmatic defect, diagnostic accuracy was found equally high among three image modalities(P>0.05). Conclusion: This study indicates that US is the most accurate diagnostic method in detecting injury to the diaphragm in a rabbit model. The findings obtained in this experimental study can be applied to the diaphragmatic rupture of human being.

  • PDF

An adult asymptomatic pulmonary artery sling (성인 무증상 폐동맥 슬링)

  • Chung, Han Hee;Baek, Ju Yeol;Lee, Won Yik;Jang, Ji Hye;Jeong, Min Young;Woo, Gi Hyeon;Park, Seong Il;Kim, Il Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.109-112
    • /
    • 2014
  • A pulmonary artery sling is a very rare congenital abnormality in which the left pulmonary artery rises from the posterior surface of the right pulmonary artery and then passes between the trachea and the esophagus, causing tracheal compression. It is associated with tracheo-bronchial abnormalities (50%) and cardiovascular abnormalities (30%). It may produce respiratory symptoms through the airway compression of the abnormal left pulmonary artery and congenital abnormalities associated with it. Because most (90%) pulmonary artery sling patients present symptoms during infancy, their condition is often diagnosed in the first year of life. However, a pulmonary artery sling is occasionally found in adults. It is usually asymptomatic and found incidentally. This is a very rare case of an asymptomatic pulmonary artery sling in an adult. A 38-year-old man presented symptoms of mild exertional dyspnea. His spiral computed tomography showed a pulmonary artery sling. He was discharged without specific treatment because his symptoms improved without specific treatment and might not have been associated with a pulmonary artery sling. We report an adult case of an asymptomatic pulmonary artery sling diagnosed via spiral computed tomography, accompanied by a literature review.

Evaluation of Tracheobronchial Diseases: Comparison of Different Imaging Techniques

  • Qihang Chen;Jin Mo Goo;Joon Beom Seo;Myung Jin Chung;Yu-Jin Lee;Jung-Gi Im
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.135-141
    • /
    • 2000
  • Objective: To compare the clinical utility of the different imaging techniques used for the evaluation of tracheobronchial diseases. Materials and Methods: Forty-one patients with tracheobronchial diseases [tuberculosis (n = 18), bronchogenic carcinoma (n = 10), congenital abnormality (n = 3), post-operative stenosis (n = 2), and others (n = 8)] underwent chest radiography and spiral CT. Two sets of scan data were obtained: one from routine thick-section axial images and the other from thin-section axial images. Multiplanar reconstruction (MPR) and shaded surface display (SSD) images were obtained from thin-section data. Applying a 5-point scale, two observers compared chest radiography, routine CT, thin-section spiral CT, MPR and SSD imaging with regard to the detection, localization, extent, and characterization of a lesion, information on its relationship with adjacent structures, and overall information. Results: SSD images were the most informative with regard to the detection (3.95±0.31), localization (3.95±0.22) and extent of a lesion (3.85±0.42), and overall information (3.83±0.44), while thin-section spiral CT scans provided most information regarding its relationship with adjacent structures (3.56±0.50) and characterization of the lesion (3.51±0.61). Conclusion: SSD images and thin-section spiral CT scans can provide valuable information for the evaluation of tracheobronchial disease.

  • PDF

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.

Computed Tomographic Images of Vertebral Disc Herniation in Dogs (개에서 컴퓨터 단층 촬영 검사를 통한 추간판 탈출증 진단례)

  • 이기창;송경진;권정국;최민철
    • Journal of Veterinary Clinics
    • /
    • v.20 no.4
    • /
    • pp.519-522
    • /
    • 2003
  • An appearance of herniated intervertebral disc into thoracolumbar vertebral canal was evaluated in two patients using computed tomography (CT). Before CT scanning, plain radiography and myelography were performed in both cases. CT images were compared to those of myelography. Dogs were positioned in sternal recumbency under inhalation anesthesia and transverse slices with 2 mm thickness were obtained around thoracolumbar region. The transverse CT images were examined using both vertebral and spiral window mode. The most common findings on CT images were loss of vertebral canal epidural fat, bulging of vertebral canal disc margins, displacement of spinal cord and flatted vertebral canal. Whereas, narrowed intervertebral disc space and simple extradural pattern were the main findings on plain and contrast radiographs. CT imges showed the extent of the herniated disc lesion, type II intervertebral disc hernation, and the displacement of spinal cord in detail in both occations. It is considered that degree and precise localization of the intervertebral disc herniation and subtle lesion of spinal cord could be identified accurately using computed tomography.

Intra- and interobserver agreement of computed tomography in assessment of the mandibular condyle

  • Cho, Bong-Hae;Jung, Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.191-195
    • /
    • 2007
  • Purpose: To study the intra- and interobserver agreement of multidetector row computed tomography (MDCT) in interpretation of degenerative changes of the mandibular condyle. Materials and Methods: Five observers independently evaluated one hundred temporomandibular joint MDCT images for signs of osteophytes, erosion, sclerosis and flattening. The intra- and interobserver agreements were calculated by using Kappa statistics. Results: The intraobserver agreement was substantial for erosion (k=0.75), flattening (k=0.74) and sclerosis (k=0.72) and almost perfect for osteophytes (k=0.84). The interobserver agreement was fair for flattening (k=0.39), moderate for erosion (k=0.58) and sclerosis (k=0.48) and substantial for osteophytes (k=0.75). Conclusion: This study shows that we can expect good agreement for the presence of osteophytes, but not for flattening in the interpretation of MDCT images of the condyle.

  • PDF

Three-dimensional imaging modalities in endodontics

  • Mao, Teresa;Neelakantan, Prasanna
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.177-183
    • /
    • 2014
  • Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of periradicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

NAVIER-STOKES SIMULATION OF A VISCOUS MICRO PUMP WITH A SPIRAL CHANNEL (스파이럴 채널을 가진 초소형 점성 펌프의 Navier-Stokes 해석)

  • Seo, J.H.;Kang, D.J.
    • Journal of computational fluids engineering
    • /
    • v.16 no.1
    • /
    • pp.90-95
    • /
    • 2011
  • The Navier-Stokes equations are solved to study the flow characteristics of a micro viscous pump. The viscous micropump is consisted of a stationary disk with a spiral shaped channel and a rotating disk. A simple geometrical model for the tip clearance is proposed and validated by comparing computed flow rate with corresponding experimental data. Present numerical solutions show satisfactory agreement with the corresponding experimental data. The tip clearance effect is found to become significant as the rotational speed increases. As the pressure load increases, a reversed flow region is seen to form near the stationary disk. The height of the channel is shown to be optimized in terms of the flow rate for a given rotational speed and pressure load. The optimal height of the channel becomes small as the rotational speed decreases or the pressure load increases. The flow rate of the pump is found to be in proportion to the width of channel.