• Title/Summary/Keyword: Spinning Frequency

Search Result 65, Processing Time 0.021 seconds

Model order reduction for Campbell diagram analysis of shaft-disc-blade system in 3D finite elements

  • Phuor, Ty;Yoon, GilHo
    • Structural Engineering and Mechanics
    • /
    • v.81 no.4
    • /
    • pp.411-428
    • /
    • 2022
  • This paper presents the Campbell diagram analysis of the rotordynamic system using the full order model (FOM) and the reduced order model (ROM) techniques to determine the critical speeds, identify the stability and reduce the computational time. Due to the spin-speed-dependent matrices (e.g., centrifugal stiffening matrix), several model order reduction (MOR) techniques may be considered, such as the modal superposition (MS) method and the Krylov subspace-based MOR techniques (e.g., Ritz vector (RV), quasi-static Ritz vector (QSRV), multifrequency quasi-static Ritz vector (MQSRV), multifrequency/ multi-spin-speed quasi-static Ritz vector (MMQSRV) and the combined Ritz vector & modal superposition (RV+MS) methods). The proposed MMQSRV method in this study is extended from the MQSRV method by incorporating the rotational-speed-dependent stiffness matrices into the Krylov subspace during the MOR process. Thus, the objective of this note is to respond to the question of whether to use the MS method or the Krylov subspace-based MOR technique in establishing the Campbell diagram of the shaft-disc-blade assembly systems in three-dimensional (3D) finite element analysis (FEA). The Campbell diagrams produced by the FOM and various MOR methods are presented and discussed thoroughly by computing the norm of relative errors (ER). It is found that the RV and the MS methods are dominant at low and high rotating speeds, respectively. More precisely, as the spinning velocity becomes large, the calculated ER produced by the RV method is significantly increased; in contrast, the ER produced by the MS method is smaller and more consistent. From a computational point of view, the MORs have substantially reduced the time computing considerably compared to the FOM. Additionally, the verification of the 3D FE rotordynamic model is also provided and found to be in close agreement with the existing solutions.

Proposal on the Diagnostic Criteria of Definite Isolated Otolith Dysfunction

  • Park, Han Gyeol;Lee, Jun Ho;Oh, Seung Ha;Park, Moo Kyun;Suh, Myung-Whan
    • Journal of Audiology & Otology
    • /
    • v.23 no.2
    • /
    • pp.103-111
    • /
    • 2019
  • Background and Objectives: Dizzy patients with abnormal otolith function tests, despite a normal caloric response, are defined as having specific (isolated) otolith organ dysfunction. This study was performed to compare the differences in clinical presentation between isolated otolith dysfunction (iOD) patients with lab- and Sx-based iOD group and lab-based iOD symptoms. Subjects and Methods: The medical records of 23 iOD patients with normal caloric response but abnormal cervical vestibular evoked myogenic potential (VEMP), ocular VEMP, or subjective visual vertical were reviewed. Non-spinning vertigo was considered as otolith-related symptoms. The patients' age, onset of dizziness, Numeric Rating Scale on the severity of dizziness, and concomitant vestibular disorders were analyzed. Results: Patients in the lab-based iOD group were significantly older than those in the lab- and Sx-based iOD group. Known vestibular disorders were significantly more common in the lab-based iOD group (83.3%) compared to the lab- and Sx-based iOD group (18.2%). Despite the normal caloric response, catch-up saccade was found in the video head impulse test in more than half (54.5%) of the lab-based iOD group patients. There was no catch-up saccade in the lab- and Sx-based iOD group. There were no significant differences in gender ratio, frequency of dizziness attacks, and duration of illness. Conclusions: We propose new definitions of definite iOD (lab- and Sx-based iOD) and probable iOD (lab- or Sx-based iOD). These new definitions may help researchers to identify patients who are more likely to have true iOD, and facilitate comparisons of results between different studies.

Proposal on the Diagnostic Criteria of Definite Isolated Otolith Dysfunction

  • Park, Han Gyeol;Lee, Jun Ho;Oh, Seung Ha;Park, Moo Kyun;Suh, Myung-Whan
    • Korean Journal of Audiology
    • /
    • v.23 no.2
    • /
    • pp.103-111
    • /
    • 2019
  • Background and Objectives: Dizzy patients with abnormal otolith function tests, despite a normal caloric response, are defined as having specific (isolated) otolith organ dysfunction. This study was performed to compare the differences in clinical presentation between isolated otolith dysfunction (iOD) patients with lab- and Sx-based iOD group and lab-based iOD symptoms. Subjects and Methods: The medical records of 23 iOD patients with normal caloric response but abnormal cervical vestibular evoked myogenic potential (VEMP), ocular VEMP, or subjective visual vertical were reviewed. Non-spinning vertigo was considered as otolith-related symptoms. The patients' age, onset of dizziness, Numeric Rating Scale on the severity of dizziness, and concomitant vestibular disorders were analyzed. Results: Patients in the lab-based iOD group were significantly older than those in the lab- and Sx-based iOD group. Known vestibular disorders were significantly more common in the lab-based iOD group (83.3%) compared to the lab- and Sx-based iOD group (18.2%). Despite the normal caloric response, catch-up saccade was found in the video head impulse test in more than half (54.5%) of the lab-based iOD group patients. There was no catch-up saccade in the lab- and Sx-based iOD group. There were no significant differences in gender ratio, frequency of dizziness attacks, and duration of illness. Conclusions: We propose new definitions of definite iOD (lab- and Sx-based iOD) and probable iOD (lab- or Sx-based iOD). These new definitions may help researchers to identify patients who are more likely to have true iOD, and facilitate comparisons of results between different studies.

Economic Assessment of the Battery Energy Storage System with Its Customer Type (수용가 형태에 따른 전지전력저장시스템의 경제성 평가)

  • 손학식;최준호;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.81-89
    • /
    • 2002
  • The Battery Energy Storage System (BESS) has lots of advantages such as load leveling, quick response emergency power (spinning reserve), frequency and voltage control, improvement of reliability, and deferred generation and transmission construction. However, it is very critical that economic feasibility requires justification from the customer side of meter to promoting the dissemination of BESS in nation widely. In this paper, we proposed the economic assessment model of customer owned BESS which is complemented and improved the existing model. The proposed model is applied to the typical customer types, i.e. light industrial, commercial, and residential, which are taken from the statistical analysis on the load profile survey of Korea Electric Power COmpany (KEPCO). The economic viability performed for each customer load type to justifying their economic feasibility of BESS installation from the economic measures such as payback period, Net Present Worth (NPW), Rate Of Return (ROR). The results show that the BESS has economic benefits to the specific customer type, i.e. residential customer. Therefore, the government and the energy agency should be committing the support program, such as tax incentive, financial support, to disseminate the BESS nation widely. The results of this paper are useful to the customer investment decision-making and the national energy policy & strategy in Korea.

Integrated Rotary Genetic Analysis Microsystem for Influenza A Virus Detection

  • Jung, Jae Hwan;Park, Byung Hyun;Choi, Seok Jin;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.88-89
    • /
    • 2013
  • A variety of influenza A viruses from animal hosts are continuously prevalent throughout the world which cause human epidemics resulting millions of human infections and enormous industrial and economic damages. Thus, early diagnosis of such pathogen is of paramount importance for biomedical examination and public healthcare screening. To approach this issue, here we propose a fully integrated Rotary genetic analysis system, called Rotary Genetic Analyzer, for on-site detection of influenza A viruses with high speed. The Rotary Genetic Analyzer is made up of four parts including a disposable microchip, a servo motor for precise and high rate spinning of the chip, thermal blocks for temperature control, and a miniaturized optical fluorescence detector as shown Fig. 1. A thermal block made from duralumin is integrated with a film heater at the bottom and a resistance temperature detector (RTD) in the middle. For the efficient performance of RT-PCR, three thermal blocks are placed on the Rotary stage and the temperature of each block is corresponded to the thermal cycling, namely $95^{\circ}C$ (denature), $58^{\circ}C$ (annealing), and $72^{\circ}C$ (extension). Rotary RT-PCR was performed to amplify the target gene which was monitored by an optical fluorescent detector above the extension block. A disposable microdevice (10 cm diameter) consists of a solid-phase extraction based sample pretreatment unit, bead chamber, and 4 ${\mu}L$ of the PCR chamber as shown Fig. 2. The microchip is fabricated using a patterned polycarbonate (PC) sheet with 1 mm thickness and a PC film with 130 ${\mu}m$ thickness, which layers are thermally bonded at $138^{\circ}C$ using acetone vapour. Silicatreated microglass beads with 150~212 ${\mu}L$ diameter are introduced into the sample pretreatment chambers and held in place by weir structure for construction of solid-phase extraction system. Fig. 3 shows strobed images of sequential loading of three samples. Three samples were loaded into the reservoir simultaneously (Fig. 3A), then the influenza A H3N2 viral RNA sample was loaded at 5000 RPM for 10 sec (Fig. 3B). Washing buffer was followed at 5000 RPM for 5 min (Fig. 3C), and angular frequency was decreased to 100 RPM for siphon priming of PCR cocktail to the channel as shown in Figure 3D. Finally the PCR cocktail was loaded to the bead chamber at 2000 RPM for 10 sec, and then RPM was increased up to 5000 RPM for 1 min to obtain the as much as PCR cocktail containing the RNA template (Fig. 3E). In this system, the wastes from RNA samples and washing buffer were transported to the waste chamber, which is fully filled to the chamber with precise optimization. Then, the PCR cocktail was able to transport to the PCR chamber. Fig. 3F shows the final image of the sample pretreatment. PCR cocktail containing RNA template is successfully isolated from waste. To detect the influenza A H3N2 virus, the purified RNA with PCR cocktail in the PCR chamber was amplified by using performed the RNA capture on the proposed microdevice. The fluorescence images were described in Figure 4A at the 0, 40 cycles. The fluorescence signal (40 cycle) was drastically increased confirming the influenza A H3N2 virus. The real-time profiles were successfully obtained using the optical fluorescence detector as shown in Figure 4B. The Rotary PCR and off-chip PCR were compared with same amount of influenza A H3N2 virus. The Ct value of Rotary PCR was smaller than the off-chip PCR without contamination. The whole process of the sample pretreatment and RT-PCR could be accomplished in 30 min on the fully integrated Rotary Genetic Analyzer system. We have demonstrated a fully integrated and portable Rotary Genetic Analyzer for detection of the gene expression of influenza A virus, which has 'Sample-in-answer-out' capability including sample pretreatment, rotary amplification, and optical detection. Target gene amplification was real-time monitored using the integrated Rotary Genetic Analyzer system.

  • PDF