• Title/Summary/Keyword: Spine Stability

Search Result 136, Processing Time 0.026 seconds

Biomechanical Analysis of a Combined Interspinous Spacer with a Posterior Lumbar Fusion with Pedicle Screws (척추경나사못을 이용한 유합술과 동반 시술된 극돌기간 삽입기구의 생체역학적 연구)

  • Kim, Y.H.;Park, E.Y.;Lee, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.276-282
    • /
    • 2015
  • Recently, during the multi-level fusion with pedicle screws, interspinous spacer are sometimes substituted for the most superior level of the fusion in an attempt to reduce the number of fusion level and likelihood of degeneration process at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the interspinous spacer combined with posterior lumbar fusion with a previously-validated 3-dimensional FE model of the intact lumbar spine (L1-S1). The post-operative models were made by modifying the intact model to simulate the implantation of interspinous spacer and pedicle screws at the L3-4 and L4-5. Four different configurations of the post-op model were considered: (1) a normal spinal model; (2) Type 1, one-level fusion using posterior pedicle screws at the L4-5; (3) Type 2, two-level (L3-5) fusion; (4) Type 3, Type 1 plus Coflex$^{TM}$ at the L3-4. hybrid protocol (intact: 10 Nm) with a compressive follower load of 400N were used to flex, extend, axially rotate and laterally bend the FE model. As compared to the intact model, Type 2 showed the greatest increase in Range of motion (ROM) at the adjacent level (L2-3), followed Type 3, and Type 1 depending on the loading type. At L3-4, ROM of Type 2 was reduced by 34~56% regardless of loading mode, as compared to decrease of 55% in Type 3 only in extension. In case of normal bone strength model (Type 3_Normal), PVMS at the process and the pedicle remained less than 20% of their yield strengths regardless of loading, except in extension (about 35%). However, for the osteoporotic model (Type 3_Osteoporotic), it reached up to 56% in extension indicating increased susceptibility to fracture. This study suggested that substitution of the superior level fusion with the interspinous spacer in multi-level fusion may be able to offer similar biomechanical outcome and stability while reducing likelihood of adjacent level degeneration.

Usability Testing of Digital Pressure Bio-feedback for Spinal Rehabilitation Exercise (척추재활운동을 위한 디지털 압력바이오피드백 장치의 사용성 평가)

  • Kim, Tea-Ho;Oh, Do-Bong;Kim, Da-Yeon
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.119-126
    • /
    • 2017
  • In the clinical setting, the pressure bio-feedback device is used for the spinal rehabilitation of patients with back pain, but it has several disadvantages. The purpose of this study was to develop a digitalized pressure biofeedback system that provides precise exercise method and posture in real time during the spinal rehabilitation exercise by sensing and monitoring body movements and balance of users and providing biofeedback to users. After that, the usability testing for a digitalized pressure biofeedback system will be conducted to identify problems such as safety, performance, operability, and satisfaction, and suggest improvement directions. A total of 33 subjects were participated in the usability testing. The experts group and the users group evaluated the developed digitalized pressure biofeedback system on a scale of 5 points after using the equipment. In the user group, safety was 3.59, operability was 4.38, satisfaction was 4.49. In the expert group, safety was 2.86, operability was 3.91, and performance was 4.28. Based on the usability evaluation, if the problems of stability of the cradle for tablet PC, air injection, screen display, etc. are solved, it becomes a exercise device capable of accurately exercising and evaluating the function of the spine by checking its own motion state while the spinal stabilization exercise.

Comparative Analysis of Biomechanical Behaviors on Lumbar with Titanium and Carbon Fiber Reinforced PEEK Connecting Rods for Fusion Surgery (티타늄과 탄소 섬유 강화 PEEK로 구성된 요추 유합술용 연결봉의 의공학적 영향에 대한 비교 분석)

  • Seo, Hye-Sung;Kang, Hae-Seong;Chun, Houng-Jae
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.186-191
    • /
    • 2021
  • The lumbar spinal fusion is a treatment performed to restore the stability of the degenerated lumbar. In this study, the intervertebral discs between two or more segments are removed and a bone graft is inserted to harden the segments. The pedicle screw system is inserted to vertebral bodies to fix two or more segments so that they can be firmly fused. In this study, a total of 7 patient-specific lumbar finite element models were created and pedicle screw systems were installed. The connecting rods made of titanium and CFR-PEEK was inserted to the generated models. Finite element analysis was conducted for four representative spine behaviors and statistical analysis was performed to investigate the biomechanical effects by the material properties of connecting rods. The intradiscal pressure of adjacent segments and the range of motion of the joints of each segment were investigated. In the subjects who used CFR-PEEK instead of Ti for connecting rods, the intradiscal pressure of adjacent segments tend to decrease and the range of motion of each segment tend to increase. However, no statistically significant difference in tendency was observed under all loading conditions.

A Study on Effects of the Fall Prevention in the Rehabilitation Pilates Exercise (노인의 재활 필라테스 운동이 낙상 예방 효과에 대한 고찰)

  • Ji-Sun Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.290-300
    • /
    • 2023
  • This study was understood the risk mechanism of falls in the elderly and reviewed previous research data to see if the principle of Pilates rehabilitation exercise could have a positive effect on balance ability and postural stabilization in the elderly, and the purpose of this study is to present literature-based data on the fall prevention effect of rehabilitation Pilates exercise. First, the rehabilitation Pilates exercise makes it available for strengthening the center of the body to stabilize the spine and pelvis and stimulates the nerve root, thereby having an effect on the balance and the joint stabilization. Second, a proprioceptive sensory impairment and a musculoskeletal degenerative disease due to aging increase the loss of balance ability and the instability in posture maintenance, thereby coming to raise the risk of a fall damage caused by the difficulty in performing motor functions and by the gait disturbance. Third, the rehabilitation Pilates exercise leads to improving the core muscle strength in older adults, resulting in being capable of expecting the betterment in the balance and the reaction time motor function. And there is a positive impact on the improvement in body imbalance and on the stability in movement involved in the fall prevention, resulting in being able to suggest the possibility of likely contributing to a reduction in a fall risk rate. In conclusion, the rehabilitation Pilates as the elderly exercise program showed effects on the improvement in the body's muscular strength, on the upgrade in a sense of balance, and on the stabilization of core. Thus, it was considered to diminish the risk factors for a fall damage caused by musculoskeletal degeneration and to be capable of preventing a serious disorder of activity due to a chronic senile disease.

Evaluation of Clinical Availability for Shoulder Forced Traction Method to Minimize the Beam Hardening Artifact in Cervical-spine Computed Tomography (CT) (경추부 전산화단층촬영에서 선속 경화 인공물을 최소화하기 위한 견부 강제 견인법에 대한 임상적 유용성 평가)

  • Kim, Moonjeung;Cho, Wonjin;Kang, Suyeon;Lee, Wonseok;Park, Jinwoo;Yu, Yunsik;Im, Inchul;Lee, Jaeseung;Kim, Hyeonjin;Kwak, Byungjoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • In study suggested clinical availability to shoulder forced traction method in term of quality of image, the patient's convenience and stability, according to whether to use of shoulder forced traction bend using computed tomography(CT) that X-ray calibration and various mathematic calibration algorithm application can be applied by AEC. To achieve this, 79 patients is complaining of cervical pain oriented that shoulder forced traction bend use the before and after acquires lateral projection scout image and transverse image. transverse image of a fixed size in concern field of pixel and figure the average HU value compare that quantitative analysis. Artifact and pixel and resolution to qualitative clinical estimation image analysis. the patient feel inconvenience degree that self-diagnosis survey that estimate. As a result, lateral projection scout image if you used shoulder forced traction bend for the depicted has been an increase in the number of a cervical vertebrae. transverse image concern field shoulder forced traction bend use the before and after for pixel and the average HU-value changes was judged to be almost irrelevant. Artifact and resolution and contrast, in qualitative analysis of the results relating the observer to the unusual result. So, the patients of 82.27% complained discomfort that use of shoulder forced traction bend in self-diagnosis survey. No merit of medical image by using of bend from result was analyzed quality of image to quantitative and qualitative method judged. Nowadays, CT is supplied possible revision of quality of radiation by reduction of slice and automatic exposure controller, etc and application of preconditioning filter process due to various mathematic revision algorithm. So, image noise by beam hardening artifact should not be a problem. shoulder forced traction bend of use no longer judged clinically availability because have not influence of image quality and give discomfort, have extra dangerousness.

Posterior Lumbar Interbody Fusion Using Posterolateral Placement of A Single Cylindrical Threaded Cage and Two Regular Cages : A Biomechanical Study (단일 나사형 Cage를 이용한 후방 요추체간 융합술과 두개의 나사형 Cage를 이용한 PLIF의 생체 역학적 비교)

  • Park, Choon Keun;Hwang, Jang Hoe;Ji, Chul;Kwun, Sung Oh;Sung, Jae Hoon;Choi, Seung Jin;Lee, Sang Won;Kim, Moon Kyu;Park, Sung Chan;Cho, Kyeung Suok;Park, Chun Kun;Yuan, Hansen;Kang, Joon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.7
    • /
    • pp.883-890
    • /
    • 2001
  • Objectives : An in vitro biomechanical study of posterior lumbar interbody fusion(PLIF) with threaded cage using two different approaches was performed on eighteen functional spinal units of bovine lumbar spines. The purpose of this study was to compare the segmental stiffnesses among PLIF with one long posterolateral cage, PLIF with one long posterolateral cage and simultaneous facet joint fixation, and PLIF with two posterior cages. Methods : Eighteen bovine lumbar functional spinal units were divided into three groups. All specimens were tested intact and with cage insertion. Group 1(n=12) had a long threaded cage($15{\times}36mm$) inserted posterolaterally and oriented counter anterolaterally on the left side by posterior approach with left unilateral facetectomy. Group 2(n=6) had two regular length cages($15{\times}24mm$) inserted posteriorly with bilateral facetectomy. Six specimens from group 1 were then retested after unilateral facet joint screw fixation in neutral(group 3). Likewise, the other six specimens from group 1 were retested after fixation with a facet joint screw in an extended position(group 4). Nondestructive tests were performed in pure compression, flexion, extension, lateral bending, and torsion. Results : PLIF with a single cage, group 1, had a significantly higher stiffnesses than PLIF with two cages, group 2, in left and right torsion(p<0.05). Group 1 showed higher stiffness values than group 2 in pure compression, flexion, left and right bending but were not significantly different. Group 3 showed a significant increase in stiffness in comparison to group 1 for pure compression, extension, left bending and right torsion(p<0.05). For group 4, the stiffness significantly increased in comparison to group 1 for extension, flexion and right torsion(p<0.05). Although there was no significant difference between groups 3 and 4, group 4 had increased stiffness in extension, flexion, right bending and torsion. Conclusion : Posterior lumbar interbody fusion with a single long threaded cage inserted posterolaterally with unilateral facetectomy enables sufficient decompression while maintaining a majority of the posterior elements. In combination with a facet joint screw fixation, adequate postoperative stability can be achieved. We suggest that posterolateral insertion of a long threaded cage is biomechanically an ideal alternative to PLIF.

  • PDF