• 제목/요약/키워드: Spinal cord dose

검색결과 148건 처리시간 0.023초

표준 전자선 cone의 확장된 SSD에서의 선량평가 및 자체제작한 전자선 cone의 특성 (The Dosimetric evaluation of the standard electron cone for the extended cone for the extended SSD and The Dosimetric characteristics of the custom-made electron cone)

  • 정세영;정희영;김영범;권영호
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.73-78
    • /
    • 1999
  • In general, the patients of the head and neck cancer are treated with 4MV photon beam up to prescribed dose, but spinal cord should be excluded in the treatment field. When its absorbed dose is limited at the tolerance dose. In case of the patients who has the positive posterior neck nodes need a boost electron beam treatment to the prescribed dose. In that case, the anatomical structure of the neck and the physical structure of the standard electron cone interrupt to allow proper access to the disease site. Therefore, we extended treatment SSD for the remove of the those hindrances. In this study, we evaluated the dosimetric variation of the standard electron cone for the extended SSD, from 100cm to 120cm, 5 cm increment, and compare to the custom-made electron cone. As a result, the $\%$ depth dose, the point of maximum dose and the range of maximum were changed within the $2\%$. The penumbra width was increased from 1.0cm to 2.0cm. However, the dosimetric characteristics of the custom-made electron cone was very similar to that of the 100cm SSD standard electron cone and due to its characteristic of physical structure, patients didn't need re-positioning after photon beam treatment, therefore accurate treatment was possible, we conclude that the custom-made electron cone was very useful for the clinical practice.

  • PDF

횡단척수염 환자에서 경막외 스테로이드 투여에 의한 치료 경험 -증례보고- (Experience of Epidural Steroids in Transverse Myelitis -A case report-)

  • 남복희;문호식;김정학;김대성;성춘호
    • The Korean Journal of Pain
    • /
    • 제22권1호
    • /
    • pp.92-95
    • /
    • 2009
  • Transverse myelitis is a focal inflammatory disorder of the spinal cord characterized by motor, sensory, and autonomic dysfunction. A 41-year-old man with transverse myelitis and no pre-existing neurologic disease presented with hypesthesia, numbness, weakness in the both lower extremities, back pain, decreased libido, constipation, and dysuria. A MRI test showed intramedullary high signal intensity between T4 and T8 on a T2-weighted image. After high-dose intravenous methylprednisolone and oral prednisolone therapy, he showed facial swelling and acneiform eruption. Therefore, we injected 40 mg methylprednisolone via an epidural route. A 7-dose serial treatment improved most symptoms. A follow up MRI showed radiological improvement. We report a case of transverse myelitis treated by epidural steroids.

비소세포폐암 III, IV기 환자에 있어서 Shell-Type Pseudo Target을 이용한 세기 조절 방사선치료계획기법의 유용성 평가 (Assessment of the Usefulness of an IMRT Plan Using a Shell-Type Pseudo Target with Patients in Stage III or IV of NSCLC)

  • 이상봉;박기주;박두찬;김만우;김준곤;노성환
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.95-106
    • /
    • 2012
  • 목 적: 비소세포폐암(Non-Small Cell Lung Cancer, NSCLC) III, IV기 환자의 방사선 치료 시 Shell-Type Pseudo Target의 유무에 따른 IMRT 치료계획의 유용성을 알아보고자 한다. 대상 및 방법: NSCLC III, IV기 환자 22명을 대상으로 Shell-Type Pseudo Target이 있을 때와(SPT) Shell-Type Pseudo Target이 없을 때(WSPT) 각각의 세기변조방사선치료(Intensity-Modulated Radiation Therapy, IMRT)계획을 세운 후, 선량-체적 히스토그람(Dose-Volume Histogram, DVH) 분석을 통해 종양 표적 내의 균일성 지수(Homogeneity Index, HI), 종양 표적에 대한 선량조형 지수(Conformity Index, CI), 척수 최대선량(Spinal Cord Maximum Dose), 식도에 대한 $V_{50%}$, 평균 폐 선량(Mean Lung Dose, MLD), 폐에 대한 $V_{40%}$ $V_{30%}$ $V_{20%}$ $V_{10%}$ $V_{5%}$ 등의 선량학적인 비교를 통해서 평가하였다. 결 과: WSPT와 SPT에 따른 각각의 CI 값은 평균 $1.22{\pm}0.04$, $1.16{\pm}0.032$ (.000*), HI 값은 평균 $1.06{\pm}0.015$, $1.07{\pm}0.014$ (.000*)로 나타났으며, CI 값은 SPT의 경우에서 각각의 차이 값에 대한 평균은 $-5.16{\pm}2.54%$의 감소를 보였으며, HI 값은 SPT의 경우에서 평균 $0.81{\pm}0.47%$ 증가된 것으로 나타났다. 식도에 대한 $V_{50%}$에서는 각각 $14.54{\pm}12.01%$ (WSPT), $12.14{\pm}11.09%$ (.000*, SPT)로 SPT에서 차이 값에 대한 평균이 $-26.37{\pm}25.05%$ 감소되었고, 척수 최대선량에서도 평균 선량이 각각 $3,898.44{\pm}1,075.0$ cGy (WSPT), $3,810.8{\pm}1,134.9$ cGy (.004*, SPT)로 SPT의 경우 평균 $-3.36{\pm}5.81%$ 감소되었다. 폐에 대한 $V_{X%}$에서는 $V_{5%}$, $V_{10%}$의 경우 차이 값에 대한 평균이 $-1.62{\pm}2.29%$ (.006*), $-1.98{\pm}5.02%$ (.005*)로 SPT의 경우에서 감소됨을 보여 주었고, 마찬가지로 $V_{20%}$, $V_{30%}$, $V_{40%}$에서도 각각 $-3.51{\pm}3.07%$ (.000*), $-4.84{\pm}6.01%$ (.000*), $-6.16{\pm}8.46%$ (.001*)로 SPT 경우에서 통계학적으로 유의함을 보이면서 감소한 것으로 나타났다. MLD의 평가에서도 SPT의 경우에서 평균 $-2.83{\pm}2.41%$ (.000*)의 감소를 보여주었으며, 이는 평균 169 cGy (Max: 547 cGy, Min: 6.4 cGy)의 처방선량을 SPT 사용 시 올릴 수 있는 결과를 보여주었다. 결 론: NSCLC III, IV기 환자의 방사선 치료 시 SPT를 이용한 IMRT 치료계획이 정상 폐에 들어가는 방사선량을 줄임으로 인해 방사선치료로 유발되는 폐렴의 위험을 감소시킬 수 있을 거라 생각되고, 또한 얼마간의 처방선량 증가로 인한 방사선치료 국소제어실패율을 감소시키는 동시에 치료효과를 증대 시킬 수 있을 것이라 사료된다.

  • PDF

식도암 세기조절방사선치료와 용적세기조절회전치료에 대한 Jaw-Tracking의 유용성 평가 (Effectiveness Assessment on Jaw-Tracking in Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Esophageal Cancer)

  • 오현택;유순미;전수동;김민수;송흥권;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.33-41
    • /
    • 2019
  • 목 적: 식도암 방사선치료 시 세기조절방사선치료(Intensity Modulated Radiation Therapy, IMRT) 및 용적세기조절회전치료(Volumetric Modulated Arc Therapy, VMAT)에서 Jaw-Tracking 기법 유 무에 따라 저선량 영역에 대한 주변 정상장기의 용적선량을 분석하여 그 유용성을 평가하고자 한다. 대상 및 방법: 본 원에서 사용하고 있는 선형가속기 VitalBeamTM(Varian Medical System, U.S.A)으로 식도암 방사선치료를 받은 27명을 대상으로 하였으며, 치료계획은 Eclipse(Ver. 13.6 Varian, U.S.A)를 이용하여 Jaw-Tracking(JT)을 사용한 치료계획과 Non Jaw-Tracking(NJT) 치료계획을 수립하였으며, 치료계획용적(Planning Target Volume, PTV)에 빗장위림프절(Supraclavicular Lymph Nodes, SCL)이 포함되어 있는 T자형 PTV를 가진 환자를 대상으로 하였다. 조사범위에 대한 영향을 확인하기 위해 복강(Celiac) 포함 여부로 비교군을 나누었다. 수립된 치료계획의 비교를 위해 손상위험장기는 양측 폐, 심장, 척수를 비교하였으며 Conformity Index(CI), Homogeneity Index(HI)를 비교하였다. 임상적용 검증을 위해 전자포탈영상장치(Electronic Portal Imaging Device, EPID)를 이용하여 Portal Dosimetry를 실시하였고, 선량 영역의 임계치(Threshold)를 10 %, 5 %, 0 %로 매개변수로 설정하여 감마분석을 실시하였다. 결 과: 모든 치료계획은 3 mm / 3 %, 감마통과율 95 % 기준에 대해 Threshold 10 %의 경우 95 % 이상으로 JT, NJT 모두 통과하였으며, IMRT는 Threshold가 5 %, 0 %로 줄어들수록 JT보다 NJT의 값이 1 % 이상 줄어 들었다. IMRT에서 양측 폐의 $V_5$$V_{10}$은 JT에서 Celiac을 포함하지 않을 때 최대 14.7 %, 평균 8.5 %, 5.3 % 만큼 감소했고, $D_{mean}$$72.3{\pm}51cGy$ 감소하였으며, Celiac을 포함할 때 JT에서 선량감소가 증가하였다. 심장의 $D_{mean}$$68.9{\pm}38.5cGy$, 척수의 $D_{max}$$39.7{\pm]30.1cGy$만큼 감소하였다. VMAT은 JT기법 사용 시 폐에서 $V_5$ 평균 2.5 % 감소하였고, 심장 및 척수에서 소량 감소하였으며, Celiac 포함 시 JT의 선량감소가 증가하였다. 결 론: 식도암 치료계획에서 IMRT가 JT 사용 시 양측 폐의 $V_5$, $V_{10}$에서 유의미한 감소가 나타났고, 저 선량영역에서 조사범위가 클수록 선량감소가 크게 나타났다. 따라서 식도암 방사선치료에는 IMRT가 VMAT보다 JT 적용 시 더 효과적이며, 저 선량영역에서의 MLC 누설 및 투과선량으로부터 정상장기를 보호할 수 있다.

척추뼈전이암 환자의 체부정위방사선치료계획 비교: 동시통합추가치료법 대 RTOG 0631 프로토콜 (Comparison of Dose Distribution in Spine Radiosurgery Plans: Simultaneously Integrated Boost and RTOG 0631 Protocol)

  • 박수연;오동렬;박희철;김진성;김종식;신은혁;김혜영;정상훈;한영이
    • 한국의학물리학회지:의학물리
    • /
    • 제25권3호
    • /
    • pp.176-184
    • /
    • 2014
  • 척추뼈전이암 환자를 대상으로 본원의 동시통합추가치료법(SIB)과 RTOG 0631 프로토콜에 따른 체부정위방사선치료계획을 세우고, 선량분포를 비교하였다. 간암 원발인 척추 뼈 전이암 환자 5명을 대상으로 전산화단층촬영 영상과 자기공명영상(T1, T2)를 바탕으로 영상융합을 시행하였다. 본원에서 시행하는 SIB방법은 영상에서 보이는 종양을 GTV로 설정하고, GTV를 포함한 전체 척추체부(entire vertebral body, VB)를 CTV1로 정의하였고 GTV에 18 Gy CTV1에 10 Gy를 1회 처방하였다. RTOG 0631 프로토콜 방법은 GTV의 침윤 정도에 따라 주변부의 추근, 좌우 횡돌기 및 극돌기 등을 선택적으로 포함하여 CTV2로 정의하였고 18 Gy 1회 처방하여 체부정위방사선치료계획을 시행하였다. 선량체적화 결과값을 선량-체적 히스토그램을 통해 분석한 결과, 두 방법 모두 표적에 대하여 처방 선량을 만족하였으며, 척수 및 정상 장기에 대하여는 SIB방법이 RTOG 0631프로토콜보다는 낮은 값을 보였다. 또한, 전체 VB의 조사선량분포를 정량화한 결과, RTOG 0631프로토콜에서도 SIB방법과 동일한 처방선량 허용치 85%이상을 포함하는 것으로 나타났다. 하지만 정상 장기에 대한 선량은 RTOG 0631 프로토콜에 따른 치료 방법이 높은 편이었다. 주변부 장기의 부작용이 우려되는 임상적 상황의 경우 조사 체적이 적은 SIB방법이 좋은 선택이 될 수 있을 것이다. 결론적으로 SIB방법이나 RTOG 0631 프로토콜에 따른 표적체적 설정을 통한 체부정위방사선치료계획 모두 유사한 결과를 보였으며, 향후 다양한 연구를 통해 종양제어확률 및 부작용 확률의 차이를 분석해야 할 것이다.

포르말린 및 열성 자극 유발 통증에 대한 척수강 Melatonin의 항침해 효과 (Antinociceptive Effects of Intrathecal Melatonin on Formalin- and Thermal-induced Pain in Rats)

  • 정성태;진원종;배홍범;김석재;최정일;강명우;정창영;윤명하
    • The Korean Journal of Pain
    • /
    • 제19권2호
    • /
    • pp.137-141
    • /
    • 2006
  • Background: It has been known that melatonin is involved in the modulation of nociceptive transmission. However, the effect of melatonin administered spinally has not been examined. Therefore, we examined the effect of melatonin on the formalin-induced or thermal-induced nociception at the spinal level. Methods: Intrathecal catheter was inserted into the subarachnoid space of male Sprague-Dawley rats. Pain was assessed by formalin test (induced by injection of $50{\mu}l$ of a 5% formalin solution to the hindpaw) or Hot-Box test (induced by radiant heat application to the hindpaw). The effect of intrathecal melatonin was examined on flinching behavior in the formalin test or withdrawal response in Hot-Box test. Results: Intrathecal melatonin produced a limited, but dose-dependent reduction of the flinching response during phase 1 and 2 in the formalin test. In addition, melatonin delivered at evening also decreased the flinching response in both phases of the formalin test. Melatonin restrictively increased the withdrawal latency in Hot-Box test. Conclusions: These results suggest that melatonin is active against the formalin- and thermal-induced nocicpetion at the spinal level, but the effect is limited.

Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study

  • Mani, Karthick Raj;Upadhayay, Sagar;Das, K.J. Maria
    • Radiation Oncology Journal
    • /
    • 제35권1호
    • /
    • pp.90-100
    • /
    • 2017
  • Purpose: To Study the dosimetric advantage of the Jaw tracking technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for Head and Neck Cancers. Materials and Methods: We retrospectively selected 10 previously treated head and neck cancer patients stage (T1/T2, N1, M0) in this study. All the patients were planned for IMRT and VMAT with simultaneous integrated boost technique. IMRT and VMAT plans were performed with jaw tracking (JT) and with static jaw (SJ) technique by keeping the same constraints and priorities for a particular patient. Target conformity, dose to the critical structures and low dose volumes were recorded and analyzed for IMRT and VMAT plans with and without JT for all the patients. Results: The conformity index average of all patients followed by standard deviation (${\bar{x}}{\pm}{\sigma}_{\bar{x}}$) of the JT-IMRT, SJ-IMRT, JT-VMAT, and SJ-VMAT were $1.72{\pm}0.56$, $1.67{\pm}0.57$, $1.83{\pm}0.65$, and $1.85{\pm}0.64$, and homogeneity index were $0.059{\pm}0.05$, $0.064{\pm}0.05$, $0.064{\pm}0.04$, and $0.064{\pm}0.05$. JT-IMRT shows significant mean reduction in right parotid and left parotid shows of 7.64% (p < 0.001) and 7.45% (p < 0.001) compare to SJ-IMRT. JT-IMRT plans also shows considerable dose reduction to thyroid, inferior constrictors, spinal cord and brainstem compared to the SJ-IMRT plans. Conclusion: Significant dose reductions were observed for critical structure in the JT-IMRT compared to SJ-IMRT technique. In JT-VMAT plans dose reduction to the critical structure were not significant compared to the SJ-IMRT due to relatively lesser monitor units.

흰쥐의 술 후 통증 모델에서 T형 칼슘 통로 차단제인 Ethosuximide와 Mibefradil의 항통각과민 효과 (Antihyperalgesic Effects of Ethosuximide and Mibefradil, T-type Voltage Activated Calcium Channel Blockers, in a Rat Model of Postoperative Pain)

  • 신혜란;차영덕;한정욱;윤정원;김부성;송장호
    • The Korean Journal of Pain
    • /
    • 제20권2호
    • /
    • pp.92-99
    • /
    • 2007
  • Background: A correlation between a T-type voltage activated calcium channel (VACC) and pain mechanism has not yet been established. The purpose of this study is to find out the effect of ethosuximide and mibefradil, representative selective T-type VACC blockers on postoperative pain using an incisional pain model of rats. Methods: After performing a plantar incision, rats were stabilized on plastic mesh for 2 hours. Then, the rats were injected with ethosuximide or mibefradil, intraperitoneally and intrathecally. The level of withdrawal threshold to the von Frey filament near the incision site was determined and the dose response curves were obtained. Results: After an intraperitoneal ethosuximide or mibefradil injection, the dose-response curve showed a dose-dependent increase of the threshold in a withdrawal reaction. After an intrathecal injection of ethosuximide, the threshold of a withdrawal reaction to mechanical stimulation increased and the increase was dose-dependent. After an intrathecal injection of mibefradil, no change occurred in either the threshold of a withdrawal reaction to mechanical stimulation or a dose-response curve. Conclusions: The T-type VACC blockers in a rat model of postoperative pain showed the antihyperalgesic effect. This effect might be due to blockade of T-type VACC, which was distributed in the peripheral nociceptors or at the supraspinal level. Further studies of the effect of T-type VACC on a pain transmission mechanism at the spinal cord level would be needed.

폐암 환자의 정위적방사선 치료 시 이중 에너지를 이용한 치료 방법의 유용성 평가 (Evaluation of useful treatment which uses dual-energy when curing lung-cancer patient with stereotactic body radiation therapy)

  • 장형준;이영규;김영재;박영규
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.87-99
    • /
    • 2016
  • 목 적 : 종양의 위치에 따라 단일에너지를 이용한 치료계획과 이중에너지를 사용하는 치료계획을 정위적방사선 치료에 적용하여 실제 종양에 부여되는 선량의 변화와 종양과 인접한 부분에 위치하는 정상조직의 선량을 비교하여 임상적 유용성을 평가하고자 한다. 대상 및 방법 : 총 10명의 환자 CT 영상을 획득한 후 각각 단일에너지, 이중 에너지에 대한 체적변조회전치료 기법에 대한 치료 계획을 수립하였다. 종양 측 변화 요인을 분석하기 위하여 조형계수(CI)와 균질성 지수(HI), 최대 선량을 각각 계산했으며, 정상 조직에 대한 선량 분포를 비교하기 위하여 $V_{10}$$V_5$, 종양에 가장 근접한 첫 번째 ~ 네 번째 갈비뼈($1^{st}{\sim}4^{th}$ Rib), 척수(Spinal Cord), 식도(Esophagus)와 기관(Trachea)를 선정하였다. 또한 계획한 선량 분포가 실제 전달되는 정확성을 확인하기 위하여 2차원 이온전리함 배열을 이용하여 선량 측정을 시행하였다. 결 과 : 종양 측 인자의 경우 조형계수와 균질성 지수는 두 에너지를 사용했을 경우가 1에 가까운 값을 나타냈다. 최대 선량의 경우 앞쪽 흉벽은 약 2%, 등쪽 종양의 경우는 동등한 값을 나타냈다. 정상 조직의 경우 앞쪽 흉벽 종양은 인접한 갈비뼈에서 두 에너지를 동시에 사용한 경우 각각 4%, 5% 감소하였고, 기관지의 경우 11%, 17% 감소하였다. 폐의 선량 분포의 경우 $V_{10}$의 경우 1.5%, $V_5$의 경우 1%로 감소함을 나타냈다. 뒤쪽 흉벽의 경우 종양에 인접한 갈비뼈는 두 에너지를 이용한 경우에서 각각 6%, 1%, 4%, 12% 감소하였고, 폐의 선량 분포에서는 $V_{10}$ 3%, $V_5$ 3.1% 감소됨을 나타내었다. 선량 측정의 경우 모든 에너지에서 감마지표 3mm/3%의 결과에 부합하였다. 결 론 : 단일 에너지를 이용한 치료 계획 보다 두 에너지를 동시에 사용하는 경우가 표재성 종양에 대해 보다 유용하게 적용될 수 있을 것으로 사료된다.

  • PDF

관절염 모델에서 가미청열사습탕(加味淸熱瀉濕湯)의 진통 및 소염 효과에 관한 연구 (Anti-nociceptive and Anti-inflammatory Effects of Gami-cheongyulsaseub-tang in Arthritic Model)

  • 김일현;이하일;이세원;권영미;송용선
    • 한방재활의학과학회지
    • /
    • 제25권1호
    • /
    • pp.27-44
    • /
    • 2015
  • Objectives This study was carried out to find the effects of Gami-cheongyulsaseub-tang (hereinafter referred to GCST) on the inhibition of zymosan-induced pain in rats and collagen II-induced arthritis (CIA) in DBA/1J mouse. Methods As an acute inflammatory pain model, peripheral inflammation was induced by intraplantar injection of zymosan into the right hind paw in rats and then the hyperalgesia and pain regulating factors in spinal cord were analyzed. As a chronic inflammation model, the mixture of collagen II and complete Freund's adjuvant was treated into mice to establish rheumatoid arthritis and then body weight, thickness of hind paw, pathological change of spleen, immunological rheumatoid factor (IgG1, IgG2a, IgG2b, IgM and anti-collagen II), pro-inflammatory cytokines, and bone injury were analyzed. Results In the acute inflammatory pain model, GCST significantly inhibited the thermal and mechanical hyperalgesia and the pain regulating factors, including Fos, CD11b, PKA and PKC, in the spinal cord with a dose-dependent manner. In the chronic rheumatoid arthritis model, GCST administration decreased arthritic index and paw edema as compared with CIA control group. In particular, GCST reduced significantly the serum levels of total IgG2a, IgG2b, IgM, and specific anti-collagen II, but not total IgG1. GCST also resulted in the attenuation of bone injury and spleen enlargement/adhesion in CIA mice. Moreover, the secretion of pro-inflammatory cytokines TNF-${\alpha}$ and IL-$1{\beta}$ in CIA mice was significantly reduced by GCST in a dose-dependent manner. Conclusions Comparison of the results in this study showed that GCST had anti-nociceptive and immunomodulatory effects. These data imply that GCST can be used as an effective drug for not only rheumatoid arthritic pain but also other auto-immune diseases.