• Title/Summary/Keyword: Spin-echo image

Search Result 96, Processing Time 0.074 seconds

Development of TEM Coil for Animal Experiments at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.78-78
    • /
    • 2002
  • Purpose: The purpose of this study is to describe a distributed circuit approach to high frequency volume coil design illustrated with specific coils built accordingly and results obtained from animal studies at 3.0 tesla. Method: All experiments were conducted on 3T MRI system (Medinus Co., Ltd. Korea). The tuned TEM resonator measures 15cm outer diameter. by 10cm inside diameter by 30cm in length. The inside diameter and length were determined by animals body or head size (eg. rats or small dogs, etc.) while the outer diameter was chosen for compactness with some sacrifice of the optimal coil Q predicted for a larger cavity. A spin echo sequence with a TR/TE/flip angle=500/12.4ms/$75^{\circ}$was used to check image qualities with phantom. The breed of rat which used for animal images was Sprague-dawley(SD) and was anesthetic using ketamin hydrochloride 75mg/kg.

  • PDF

Development of Birdcage Resonator for Various Absorption Regions at 3T (3T MRI에서 흡수영역의 변화에 따른 Birdcage Resonator의 개발)

  • 이정우;최보영;윤성익;이형구;서태석;허순녕
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.54-58
    • /
    • 2004
  • The aim of this study was to develop special birdcage resonators for small objects including the human wrist, hand and small animals, using 3T MRI/MRS. Before substantial development, different types of parameters were arranged, based on theoretical analysis, through lumped element transmission line theory. The primary analysis was peformed with a network analyzer (HP 4195A) and the final experimental analysis was carried out with 3T MRI (Medinus, Korea). The manufactured birdcage resonator is typically composed of 12-element structures to which a low-pass filter is fundamentally applied. The diameter and length of each element of the birdcage resonator were as follows: (1) diameter 12 cm, length of element 22 cm, (2) diameter 15 cm, length of element 22 cm, and (2) diameter 17 cm, length of element 25 cm. Copper tape with a width of 1 cm was used for the coils. MRI acquisition parameters were TR=500 ms, TE=17 ms, and Ave=2 for T1-WT images, and TR=4,000 ms, TE=96 ms, and Ave=2 for T2-WT images. The ratio of the samples diameter to the birdcage resonators diameter was approximately 55%, 63% and 70%, respectively, for the three elements. This study determined that the best image quality and S/N ratio were obtained when the ratio of the object's diameter was approximately 50∼80%. A general theoretical analysis of the birdcage coil differs in many respects from the experimental results which were influenced by many factors that were not considering when the general theoretical analysis of the birdcage coil was peformed. The induced resistance may be considered as part of the resistive loss if the quantitative value can be determined using a radiation resistance approach.

  • PDF

Evaluation of Articular Cartilage using 3D FFE-PROSET Technique in 3.0 T Knee MR Imaging : Comparison with 2D TSE - SPIR Technique (3.0T 무릎자기공명영상에서 3차원 FFE-PROSET 기법을 이용한 관절연골평가 : 2차원 TSE-SPIR 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.599-606
    • /
    • 2013
  • The purpose of this study is to know a clinical usefulness for delineation of articular cartilage compared with 2D TSE-SPIR and 3D FFE-PROSET technique. From January 2013 to september 2013, a total of 30 normal volunteers(12 men and 18 women aged between 35 and 55 years; mean 49.48 years) were studied on a philips 3.0T MRI scanner. As a quantitative analysis, SNRs and CNRs were evaluated by using two methods for delineation of articular cartilage. As a qualitative analysis, image quality was evaluated by special radiological technologist of MRI for image delineation on a three grade. As a results, SNRs and CNRs for articular cartilage were significantly greater for the 3D FFE-PROSET(SNRs: 8.40, 114.02, 9.53, CNRs: 104.49, 139.49) technique compared to 2D TSE-SPIR(SNRs: 4.41, 71.63, 7.34, CNRs: 64.30, 58.41) technique, image quality also was higher for evaluation of 3D FFE-PROSET(2.40) technique(p=0.0021). In conclusion, this study showed that a 3D FFE-PROSET MRI has improved SNRs and CNRs for evaluating of the articular cartilage, these conclusions in the future will be provided useful information in diagnosis of articular cartilage.

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

Correlation between Magnetic Resonance Image Signal Changes and Electromyographic Findings after Sciatic Nerve Transection in the Rat (백서의 좌골신경 절단 후 비복근의 자기공명영상 신호강도 변화와 근전도 소견의 관계)

  • Lee, Joo Hwan;Lee, Jang Chul;Kim, Dong Won;Park, Ki Young;Lee, Sung Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.101-107
    • /
    • 2000
  • Objectives : The evaluation of peripheral nerve injuries has traditionally relied on a clinical history, physical examination, and electrodiagnostic studies. The purpose of the present study was to examine serial magnetic resonance image(MRI) changes following acute muscle denervation under experimental conditions and to identify potential advantages and disadvantages of this use of MRI. Methods : An experimental transection of right sciatic nerve on Spargue-Dawley rats was performed. MRI was performed with T1-weighted spin-echo and STIR sequences. The imaging findings were compared with EMG in order to determine its sensitivity relative to this standard procedure. A simultaneous histopathological study provided information about the morphological basis of the imaging findings. Signal intensities were expressed as a ratio of abnormal to normal. Results : The signal intensity ratio of muscles with the STIR sequence was increased significantly at 2 weeks after sciatic nerve transection(p<0.05), although definite signal change was seen as early as 4 days postdenervation in one. EMG revealed significant denervation potential from 3 days after nerve transection. Diffuse cell atrophy was revealed hostologically at 2 weeks after transection, which was at the same time of significant signal change in MRI. Conclusion : MRI signal changes in denervated muscles secondary to nerve injury correlate with the degree of muscle atrophy on histologic examination. In addition to EMG, MRI can document the course of muscle atrophy and mesenchymal abnormalities in denervation. These results indicate that MRI can play a complementary role in the evaluation of patients with denervation.

  • PDF

Orthodontic appliances and MR image artefacts: An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners

  • Sonesson, Mikael;Al-Qabandi, Fahad;Mansson, Sven;Abdulraheem, Salem;Bondemark, Lars;Hellen-Halme, Kristina
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.63-71
    • /
    • 2021
  • Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.

Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array (선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Kim, H.J.;Suh, J.J.;Kim, S.H.;Lee, C.H.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

The Relationship between Image Parameters and SAR for Each Sequence of MRI (MRI 검사의 시퀀스 별 영상 변수와 SAR의 관계)

  • Seong-Ho Kim;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1133-1138
    • /
    • 2023
  • This study analyzed the relationship between image parameters and specific absorption rate (SAR) in various sequence environments to optimize SAR. For this purpose, image parameters were adjusted for T2, T1, STIR, T1 FLAIR, and T2 FLAIR sequences in a 3.0T MRI, and the whole body (WB) SAR and head SAR calculated by the device were measured. Then, the SAR was evaluated by adjusting the number of images and the flip angle (FA) of the refocusing RF. As a result, SAR increased as the number of image increased in all sequences. T1 and T1 FLAIR had correlation coefficients (r) of 0.876, 0.876 (WB SAR, head SAR), 0.867, 0.867 (WB SAR, head SAR), respectively, and STIR had the highest correlation with 0.898 and 0.899 (WB SAR, head SAR). showed (p<0.05). When applied by increasing the refocusing FA, WB SAR and head SAR increased overall in all sequences. The T1 and T2 sequences showed high correlation with correlation coefficients (r) of 0.897, 0.898 (WB SAR, head SAR) and 0.914, 0.915 (WB SAR, head SAR), respectively, while the sequences to which the inversion recovery technique was applied had relatively low FA, showed less sensitivity to increase. Therefore, in a sequence with a relatively low TR, minimizing the number of image and applying the fast spin echo to reduce the refocusing FA in a sequence with a high duty cycle are effective in reducing SAR.

Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2 (뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-$T_2$ and $T_2$ sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-$T_2$ and $T_2$ was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-$T_2$, $T_2$ and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-$T_2$ and $T_2$. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by $15dB_A$ and $10dB_A$ on $T_2$ and Q-$T_2$ test. Also, the average value of heartbeat rate was lower in Q-$T_2$ for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-$T_2$. According to the qualitative analysis, the overall quality image of 59 case $T_2$ and Q-$T_2$ was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-$T_2$ is a promising technique for acoustic noise reduction and improved patient comfort.

Evaluation of Effect of Decrease in Metallic Artifacts using the Synthetic MR Technique (Synthetic MR 기법을 이용한 금속 인공물 감소 효과 평가)

  • Soon-Yong, Kwon;Nam-Yong, Ahn;Jeong-Eun, Oh;Seong-Ho, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.835-842
    • /
    • 2022
  • This study is aimed to evaluate the effects of a synthetic MR technique in reducing metal artifacts. In the experiment, the in-plane and through-plane images were acquired by applying a synthetic MR technique and a high-speed spin echo technique to a phantom manufactured with screw for spinal surgery. The area of the metal artifact was compared. The metal artifacts were measured by dividing the signal-loss and the signal pile-up areas, and the area of the final artifact was calculated through the sum of the two. As a result, the metal artifacts were relatively reduced when the synthetic MR techniques were applied to both in-plane and through-plane. Comparing by sequence, the in-plane T1 images decreased by 23.45%, T2 images by 20.85%, PD images by 19.67%, and FLAIR images by 22.12%. Also, in the case of the through-plane, the T1 image decreased by 62.95%, the T2 image decreased by 73.93%, the PD image decreased by 74.68%, and the FLAIR image decreased by 66.43%. The cause of this result is that when the synthetic MR technique is applied, the distortion is due to the signal pile-up and does not occur and the size of the entire metal artifact is reduced. Therefore, synthetic MR technique can very effectively reduce metal artifacts, which can help to increase the diagnostic value of images.