Investigation of Perfusion-weighted Signal Changes on a Pulsed Arterial Spin Labeling Magnetic Resonance Imaging Technique: Dependence on the Labeling Gap, Delay Time, Labeling Thickness, and Slice Scan Order (동맥스핀표지 뇌 관류 자기공명영상에서 라벨링 간격 및 지연시간, 표지 두께, 절편 획득 순서의 변화에 따른 관류 신호변화 연구)

  • Byun, Jae-Hoo;Park, Myung-Hwan;Kang, Ji-Yeon;Lee, Jin-Wan;Lee, Kang-Won;Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.108-118
    • /
    • 2013
  • Currently, an arterial spin labeling (ASL) magnetic resonance imaging (MRI) technique does not routinely used in clinical studies to measure perfusion in brain because optimization of imaging protocol is required to obtain optimal perfusion signals. Therefore, the objective of this study was to investigate changes of perfusion-weighed signal intensities with varying several parameters on a pulsed arterial spin labeling MRI technique obtained from a 3T MRI system. We especially evaluated alternations of ASL-MRI signal intensities on special brain areas, including in brain tissues and lobes. The signal targeting with alternating radiofrequency (STAR) pulsed ASL method was scanned on five normal subjects (mean age: 36 years, range: 29~41 years) on a 3T MRI system. Four parameters were evaluated with varying: 1) the labeling gap, 2) the labeling delay time, 3) the labeling thickness, and 4) the slice scan order. Signal intensities were obtained from the perfusion-weighted imaging on the gray and white matters and brain lobes of the frontal, parietal, temporal, and occipital areas. The results of this study were summarized: 1) Perfusion-weighted signal intensities were decreased with increasing the labeling gap in the bilateral gray matter areas and were least affected on the parietal lobe, but most affected on the occipital lobe. 2) Perfusion-weighted signal intensities were decreased with increasing the labeling delay time until 400 ms, but increased up to 1,000 ms in the bilateral gray matter areas. 3) Perfusion-weighted signal intensities were increased with increasing the labeling thickness until 120 mm in both the gray and white matter. 4) Perfusion-weighted signal intensities were higher descending scans than asending scans in both the gray and white matter. We investigated changes of perfusion-weighted signal intensities with varying several parameters in the STAR ASL method. It should require having protocol optimization processing before applying in patients. It has limitations to apply the ASL method in the white matter on a 3T MRI system.

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

3D Printed Flexible Cathode Based on Cu-EDTA that Prepared by Molecular Precursor Method and Microwave Processing for Electrochemical Machining

  • Yan, Binggong;Song, Xuan;Tian, Zhao;Huang, Xiaodi;Jiang, Kaiyong
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.180-186
    • /
    • 2020
  • In this work, a metal-ligand solution (Cu-EDTA) was prepared based on the molecular precursor method and the solution was spin-coated onto 3D printed flexible photosensitive resin sheets. After being processed by microwave, a laser with a wavelength of 355 nm was utilized to scan the spin-coated sheets and then the sheets were immersed in an electroless copper plating solution to deposit copper wires. With the help of microwave processing, the adhesion between copper wires and substrate was improved which should result from the increase of roughness, decrease of contact angle and the consistent orientation of coated film according to the results of 3D profilometer and SEM. XPS results showed that copper seeds formed after laser scanning. Using the 3D printed flexible sheets as cathode and galvanized iron as anode, electrochemical machining was conducted.

Estimation of Insolation over the Oceans around Korean Peninsula Using Satellite Data

  • Park, Kyung-Won;Kim, Young-seup;Sang, Chung-Hyo
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.227-230
    • /
    • 1999
  • Surface solar radiation over the sea is estimated using Visible and Infrared Spin Scan Radiometer data onbord Geostationary Meteorological Satellite(GMS) 5 for January, 1997 to December 1997 in clear and cloudy conditions. The hourly insolation is estimated with a spatial resolution of 5$\times$ 5 km grid. The island pyranometer belonging to the Japan Meteorological Agency is used for validation of the estimated insolation. It is shown that the estimated hourly insolation has RMSE(root mean square) error of 104 W/$m^2$. The variability of the hourly solar radiation was investigated on 3 areas over seas around Korean Peninsula. The solar radiation of East Sea is similar to Yellow Sea. The maximum value of solar radiation is on June of year. The maximum value in south sea is on August because weather is poor by low pressure and front in June

  • PDF

The retrieval of Surface Solar Insolation using SMAC code with GMS-5 satellite data

  • Yeom, Jong-Min;Han, Kyung-Soo;Kim, Young-Seup
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.458-461
    • /
    • 2005
  • Surface Solar Insolation is important for vegetation productivity, hydrology, crop growth, etc. However, ground base measurement stations installed pyranometer are often sparsely distributed, especially over oceans. In this study, Surface Solar Insolation is estimated using the visible and infrared spin scan radiometer(VISSR) data on board Geostationary Meteorological Satellite (GMS)-S covering from March 2001 to December 2001 in clear and cloudy conditions. To retrieve atmospheric factor, such as, optical depth, the amount of ozone, H20, and aerosol, SMAC (Simplified Method for Atmospheric Correction) code, is adopted. The hourly Surface Solar Insolation is estimated with a spatial resolution of $5km\;\times\;5km$ grid. The daily Surface Solar Insolation is derived from the available hourly Surface solar irradiance, independently for every pixel. The pyranometer by the Korea Meteorological Agency (KMA) is used to validate the estimated Surface Solar Insolation with a spatial resolution of $3\;\times\;3Pixels.$

  • PDF

악성뇌종양 주변부위의 역동자기공명영상의 시간신호강도곡선 양상과 예후와의 관계

  • 최순섭;김기욱;허기영;이영일
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.21-21
    • /
    • 2003
  • 목적: 악성뇌종양 주변부위의 역동자기공명영상에서의 시간신호강도곡선 양상으로 종양의 성장 양상이나 예후를 판단할 수 있는지를 알고자 한다. 대상 및 방법: Anaplastic oligodendroglioma 3예, Anaplastic astrocytoma 1예, Glioblastoma multiforme 1예, Malignant ependymoma 2예, Medulloblastorna 1예로서, 총 8예의 종양절제전, 혹은 후의 잔류 종양을 대상으로 하였다. Routine MRI에 추가하여 종양부위에서 Turbo spin echo T1 강조 역동자기공명영상을 하였으며, Gd-DTPA 0.1 mmol/kg를 급속 주사 한 후, TR/TE, 350/15, slice thickness 6 mm, slice number 3, NEX 2회, scan time은 15 초로 하여 5 분 동안 20회 영상을 얻었다. 가시적으로 조영증강이 없는 종양의 주변부위나 수술경계부위에 관심영역을 그려서 시간신호강도곡선을 얻었으며, 첫 회 조영제 통과시의 peak 이후에 신호가 감소하는 경우를 Normal pattern으로, peak 이후에 신호가 계속 유지되거나 증가하는 경우를 Tumor pattern으로 하였으며, Normal pattern과 Tumor pattern을 보인 예들을 구분하여 종양의 재성장 상태와 환자의 생존 기간을 비교 관찰하였다.

  • PDF

Magnetic Coupling in Oxoverdazyl-Benzene-Oxoverdazyl Diradical Systems: A DFT Study

  • Park, Young Geun;Ko, Kyoung Chul
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.25-35
    • /
    • 2013
  • The intramolecular magnetic coupling constant (J) values of diradical-based magnet models (S1-S5) were studied using unrestricted density functional theory. The model systems were designed with series of oxoverdazyl radicals (o-Ver(N) and o-Ver(C)) linked through a benzene coupler. They were divided according to either connectivity of the radical (C or N) or geometrical topology (meta- and para-) of benzene coupler. Reasonable relationship was found between spin density distribution and sign of J value. With our results we determined ferromagnetic (positive J value) and antiferromagnetic (negative J value) interactions. J values were also calculated along the twisting movement by the scan of dihedral angles between the radical and the coupler. An overall trend was found as absolute value of J decreased over increasing torsion angles.

  • PDF

High Resolution 3D Magnetic Resonance Fingerprinting with Hybrid Radial-Interleaved EPI Acquisition for Knee Cartilage T1, T2 Mapping

  • Han, Dongyeob;Hong, Taehwa;Lee, Yonghan;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.3
    • /
    • pp.141-155
    • /
    • 2021
  • Purpose: To develop a 3D magnetic resonance fingerprinting (MRF) method for application in high resolution knee cartilage PD, T1, T2 mapping. Materials and Methods: A novel 3D acquisition trajectory with golden-angle rotating radial in kxy direction and interleaved echo planar imaging (EPI) acquisition in the kz direction was implemented in the MRF framework. A centric order was applied to the interleaved EPI acquisition to reduce Nyquist ghosting artifact due to field inhomogeneity. For the reconstruction, singular value decomposition (SVD) compression method was used to accelerate reconstruction time and conjugate gradient sensitivity-encoding (CG-SENSE) was performed to overcome low SNR of the high resolution data. Phantom experiments were performed to verify the proposed method. In vivo experiments were performed on 6 healthy volunteers and 2 early osteoarthritis (OA) patients. Results: In the phantom experiments, the T1 and T2 values of the proposed method were in good agreement with the spin-echo references. The results from the in vivo scans showed high quality proton density (PD), T1, T2 map with EPI echo train length (NETL = 4), acceleration factor in through plane (Rz = 5), and number of radial spokes (Nspk = 4). In patients, high T2 values (50-60 ms) were seen in all transverse, sagittal, and coronal views and the damaged cartilage regions were in agreement with the hyper-intensity regions shown on conventional turbo spin-echo (TSE) images. Conclusion: The proposed 3D MRF method can acquire high resolution (0.5 mm3) quantitative maps in practical scan time (~ 7 min and 10 sec) with full coverage of the knee (FOV: 160 × 160 × 120 mm3).

Research on the Implementation of Infrared Threat Surrogate for DIRCM Performance Analysis (지향성 적외선 방해장치 성능분석을 위한 위협체모사기 구축에 관한 연구)

  • Chun, Seung-Woo;Kim, Joy;Cho, Soo-Hyung;Kim, Jae-Hyup;Yu, Hyun-Geun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.3
    • /
    • pp.97-106
    • /
    • 2015
  • In this paper, the development of infrared threat surrogate system is described and it can be used to verify the performance of DIRCM system. In this research, threat surrogates are manufactured using same F# and reflective optics used in 1st- and 2nd-Gen. real seeker so that the threat surrogate system can be used to develop code-based jamming techniques. Also the threat surrogate system can analyze the saturation jamming effect for image seeker using FPA detector. The result shows that 1st- and 2nd-generation threat surrogates have relatively precise tracking performance and jamming effect.

Principles and Technical Aspects of Perfusion Magnetic Resonance Imaging (관류 자기공명영상의 원리 및 기술)

  • Jahng, Geon-Ho;Kim, Ho-Sung;Kim, Sun-Mi;Ryu, Chang-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.91-101
    • /
    • 2011
  • Perfusion magnetic resonance imaging (pMRI) is a special technique for evaluation of blood flow. Exogenous pMRI methods which are dynamic susceptibility contrast (DSC) and dynamic contrast-enhanced (DCE) use an intravenous bolus injection of paramagnetic contrast agent. In contrast, an endogenous pMRM method which is arterial spin labeling (ASL) use diffusible blood in body. In order to scan pMRI in human, technical optimizations are very important according to disease conditions. For examples, DSC is popularly used in patients with acute stroke due to its short scan time, while DSC or DCE provides the various perfusion indices for patients with tumor. ASL is useful for children, women who are expected to be pregnant, and in patients with kidney diseases which are problematic in nephrogenic systemic fibrosis (NSF). Perfusion MRI does not require any injection of radioisotopes. We expect that demand for perfusion MRI will be higher in evaluating drug efficacy and other treatment effects.