• 제목/요약/키워드: Spin inversion

검색결과 42건 처리시간 0.03초

Synthesis and Shuttling Behavior of Rotaxanes Consisting of Crown Ether Wheel and Disulfide Dumbbell with Two Ammonium Centers

  • Furusho, Yoshio;Sanno, Ryoko;Oku, Tomoya;Takata, Toshikazu
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권11호
    • /
    • pp.1641-1644
    • /
    • 2004
  • Several [2]- and [3]rotaxanes bearing some functional groups on their wheel components and spacers with different lengths between two ammonium centers on their dumbbell components were prepared in good yields from dibenzo-24-crown-8-ether derivatives and dumbbell-shaped bis(sec-ammonium salt)s having a centrally located disulfide linkage, by utilizing the reversible thiol-disulfide interchange reaction. The shuttling behaviors of the [2]rotaxanes were investigated by $^1H$ NMR by use of the spin polarization transfer-selective inversion recovery technique. It was found that the change in spacer length in the axle resulted in a drastic change in shuttling rate of the [2]rotaxanes, although the introduction of the functional groups to the wheels did not affect the shuttling behavior at all.

Study on Direct Dipolar Effect of Neighboring Protons in Proton Coupled $^{13}C$ Relaxation Experiment

  • 남궁현;이임표;이조웅
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권11호
    • /
    • pp.1077-1084
    • /
    • 2000
  • The dipolar effect of neighboring protons that are not directly bonded to the carbon of interest on coupled carbon-13 relaxation in a simple organic molecule has been studied by comparing the relaxation behaviors of labeled carbon-13 in $Br13CH_2COOH$ with those in $BrCH_213COOH.$ Various pulse sequences, such as coupled inversion recovery pulse sequence, J-negative and J-positive pulse sequence, and nonselective and selective proton ${\pi}pulse$ sequence, were employed to perform the required coupled spin relaxation experiments. To gain information on various spectral densities, including that of dipolar-CSA cross correlation, the experiments were performed on two different spectrometers, operating, respectively, at 50.31 and 125.51MHz for 13C. The magnitude of CH dipolar spectral densities for $BrCH_213COOH$ was found to be about 8% of those for $Br13CH_2COOH$, which means the effect due to the protons not directly bonded to the carbon of interest is small but not completely negligible.

두 개내 초급성 출혈 : EPI와 다른 MR 영상 기법의 비교 (Hyperacute Intracerebral Hemorrhage : Comparison of EPI and Other MR Sequence)

  • 김정희;김옥화;서정호;박용성
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권2호
    • /
    • pp.167-172
    • /
    • 1999
  • 목적 : Echo planar image (EPn와 다론 MR 영상기법에서 2시간 이내의 초급성 출혈의 발견율의 차이를 비교해 보고자 한다. 대상 및 방법 : 인위적으로 뇌출혈을 유발시킨 백서 10마리를 대상으로 EP1, 급속 스핀에코 (FSE) T2 강조영상, Fluid attenuated inversion recovery (FLAIR) 영상, 스펀에코 (SE) Tl 강조영상과 Tl 강조 Gradient echo (GE) 영상을 이용하여, 뇌출혈을 일으킨 2시간 후에 MR 촬영을 하였다. 추가적으로 3마리는 출혈 30분 후에, 6마리는 1시간 후에 각각 EPI와 FSE T2 강조영상을 얻었다. 얻어진 영상에 대한 주관적인 시각적 평가를 하기위하여 세명의 방사선과 의사가 출혈 병변이 어느 MR 영상 기법에서 제일 잘 보이는지를 평가하였다. 정량적인 평가 로는 병변-정상 뇌설질의 대조잡음비(contrast-to-noise ratio, CNR)를 측정하였다. 통계처리는 Wilcoxon-Ranks test를 이용하였다. 결과 : 시각적 평가에서 출혈 병변이 높은 신호강도로 나타난 EP1, FLAIR, FSE T2 영상 중 EPI 영상이 특히 높은 신호강도로 나타나 제일 쉽게 병변이 구별되었다. 정량적인 평가에서 출혈 병 변-정상 뇌설질의 CNR은 EPI와 FLAIR 영상에서 다른 세 영상기법에 비해 통계적으로 유의하게 우월하였다 (p<0.01). 그러나 EPI와 FLAIR 영상간의 CNR은 동계적으로 유의한 차이가 없었다 (p>0.10). 추가적으로 출혈 30분과 1l시간 후 촬영한 모두에서 EPI영상과 FSE T2 강조 영상은 정상에 비해 높은 신호강도를 보여 병변의 구별이 가능하였다. 결론 : 백서에서 유발시킨 초급성기 뇌출혈의 여러 기법의 MR 영상 중 EPI 영상이 영상획득 시간이 가장 빠르면서 시각적 평가와 정량적 평가에서 출혈의 발견율이 가장 높아 출혈의 선속한 진단에 유용할 것으로 생각된다.

  • PDF

Quantitative Analysis of T1 Weighted Images due to Change in TI by Using the Inversion Recovery in 3.0T Brain MRI Examination

  • Han, Jung-Seok;Dong, Kyung-Rae;Chung, Woon-Kwan;Cho, Jae-Hwan;Shin, Jae-Woo;Kim, Young-Jae
    • Journal of Magnetics
    • /
    • 제17권2호
    • /
    • pp.158-162
    • /
    • 2012
  • Although 3.0T magnetic resonance imaging (MRI) has the advantages of a higher signal to noise ratio (SNR) and contrast than 1.5T MRI, there are limitations on the contrast between white and grey matter because of the long T1 recovery time when T1 images are obtained using the Spin Echo Technique. To overcome this, T1 weighted images are obtained occasionally using the inversion recovery (IR) technique, which employs a relatively long TR. The aim of this study was to determine the optimal TI in a brain examination when a T1 weighted image is obtained using the IR technique. Eight participants (male: 7, female: 1, average age: $34{\pm}14.11$) with a normal diagnosis were targeted from February 18, 2012 to February 27, 2012, and the contrast between white and grey matter as well as the contrast to noise ratio (CNRs) in each participant were measured. The CNRs of white matter and grey matter were highest at TI = 600, 650, 750, 900, 1050 and 1100 ms when the TR was 1100, 1400, 1700, 2000, 2300 and 2600 ms, respectively. Therefore, as the TIs were $44.425{\pm}0.877%$ of the TRs in the TR range of 1400-2300 ms, the optimal T1 weighted images that describe the contrast between white and grey matter can be obtained if the TIs are compensated for with $44.425{\pm}0.877%$ of the TRs in the time of setting TIs.

3T 고속스핀에코 T2강조영상에서 지방소거 반전회복기법의 유용성 연구 - SPAIR와 STIR와의 비교 - (Comparative Study on Usefulness of SPAIR and STIR Fast SE T2-weighted 3T Magnetic Resonance Imaging)

  • 이후민;윤준;여영복
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권1호
    • /
    • pp.45-50
    • /
    • 2010
  • 본 연구는 T2고속스핀에코 3.0T 자기공명영상에서 지방조직 소거기법인 SPAIR와 STIR기법의 임상적 유용성에 관한 비교연구를 시행하였다. SPAIR와 STIR 프로토콜을 사용하여 뇌의 축방향 영상(20개), 요추의 시상단면영상(20개), 고관절의 관상단면영상(17개), 무릎관절의 축방향 영상(25개)을 획득하였다. 검사부위별로 지방억제기법의 지방소거능력과 화질을 파악하기위해 지방조직의 신호강도와 불균일성을 측정하였다. 지방조직에서 불균일치는 측정된 지방 신호의 평균치(mean)에 대한 표준편차(SD)로서 그 산출은 SD/mean으로 계산하였다. 수집된 자료는 SPSS(Statistical Package for the Social Science) WIN 13.0 프로그램을 이용하여 분석한 결과 다음과 같은 결론을 얻었다. 첫째, 뇌 검사는 SPAIR가 STIR보다 지방억제능력과 화질면에서 우수한 결과를 나타냈으며, 둘째, 요추, 고관절, 무릎관절 검사는 지방의 신호억제능력은 STIR가 우수하고, 화질면에서는 SPAIR가 우수한 결과를 나타냈다.

Benefit of Using Early Contrast-Enhanced 2D T2-Weighted Fluid-Attenuated Inversion Recovery Image to Detect Leptomeningeal Metastasis in Lung-Cancer Staging

  • Kim, Han Joon;Lee, Jungbin;Lee, A Leum;Lee, Jae-Wook;Kim, Chan-Kyu;Kim, Jung Youn;Park, Sung-Tae;Chang, Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제26권1호
    • /
    • pp.32-42
    • /
    • 2022
  • Purpose: To evaluate the clinical benefit of 2D contrast-enhanced T2 fluid-attenuated inversion recovery (CE-T2 FLAIR) image for detecting leptomeningeal metastasis (LM) in the brain metastasis work-up for lung cancer. Materials and Methods: From June 2017 to July 2019, we collected all consecutive patients with lung cancer who underwent brain magnetic resonance image (MRI), including contrast-enhanced 3D fast spin echo T1 black-blood image (CE-T1WI) and CE-T2 FLAIR; we recruited clinico-radiologically suspected LM cases. Two independent readers analyzed the images for LM in three sessions: CE-T1WI, CE-T2 FLAIR, and their combination. Results: We recruited 526 patients with suspected lung cancer who underwent brain MRI; of these, we excluded 77 (insufficient image protocol, unclear pathology, different contrast media, poor image quality). Of the 449 patients, 34 were clinico-radiologically suspected to have LM; among them, 23 were diagnosed with true LM. The calculated detection performance of CE-T1WI, CE-T2 FLAIR, and combined analysis obtained from the 34 suspected LM were highest in the combined analysis (AUC: 0.80, 0.82, and 0.89, respectively). The inter-observer agreement was also the highest in the combined analysis (0.68, 0.72, and 0.86, respectively). In quantitative analyses, CNR of CE-T2 FLAIR was significantly higher than that of CE-T1WI (Wilcoxon signed rank test, P < 0.05). Conclusion: Adding CE-T2 FLAIR might provide better detection for LM in the brain-metastasis screening for lung cancer.

A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

  • Kajan, Zahra Dalili;Khademi, Jalil;Alizadeh, Ahmad;Hemmaty, Yasamin Babaei;Roushan, Zahra Atrkar
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.159-168
    • /
    • 2015
  • Purpose: This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. Material and Methods: A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo $T_1$-weighted images, fast spin-echo $T_2$-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Results: Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. Conclusion: With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

Spin and 3D shape model of Mars-crossing asteroid (2078) Nanking

  • Kim, Dong-Heun;Choi, Jung-Yong;Kim, Myung-Jin;Lee, Hee-Jae;Moon, Hong-Kyu;Choi, Yong-Jun;Kim, Yonggi
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.80.1-80.1
    • /
    • 2019
  • Photometric investigations of asteroids allow us to determine their rotation states and shape models (Apostolovska et al. 2014). Our main target, asteroid (2078) Nanking's perihelion distance (q) is 1.480 AU, which belongs to the Mars-crossing asteroid (1.3 < q < 1.66 AU). Mars-crossing asteroids are objects that cross the orbit of Mars and regarded as one of the primary sources of near-Earth asteroids due to the unstable nature of their orbits. We present the analysis of the spin parameters and 3D shape model of (2078) Nanking. We conducted Cousins_R-band time-series photometry of this asteroid from November 26, 2014 to January 17, 2015 at the Sobaeksan Optical Astronomy Observatory (SOAO) and for 25 nights from March to April 2016 using the Korea Microlensing Telescope Network (KMTNet) to reconstruct its physical model with our dense photometric datasets. Using the lightcurve inversion method (Kaasalainen & Torppa 2001; Kaasalainen et al. 2001), we determine the pole orientation and shape model of this object based on our lightcurves along with the archival data obtained from the literatures. We derived rotational period of 6.461 h, the preliminary ecliptic longitude (${\lambda}_p$) and latitude (${\beta}_p$) of its pole as ${\lambda}_p{\sim}8^{\circ}$ and ${\beta}_p{\sim}-52^{\circ}$ which indicates a retrograde rotation of the body. From the apparent W UMa-shaped lightcurve and its location in the rotation frequency-amplitude plot of Sheppard and Jewitt (2004), we suspect the contact binary nature of the body (Choi 2016).

  • PDF

High Crystalline Epitaxial Bi2Se3 Film on Metal and Semiconductor Substrates

  • 전정흠;장원준;윤종건;강세종
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.302-302
    • /
    • 2011
  • The binary chalcogenide semiconductor Bi2Se3 is at the center of intensive research on a new state of matter known as topological insulators. It has Dirac point in their band structures with robust surface states that are protected against external perturbations by strong spin-orbit coupling with broken inversion symmetry. Such unique band configurations were confirmed by recent angle-resolved photoelectron emission spectroscopy experiments with an unwanted n-type doping effect, showing a Fermi level shift of about 0.3 eV caused by atomic defects such as Se vacancies. Since the number of defects can be reduced using the molecular beam epitaxy (MBE) method. We have prepared the Bi2Se3 film on noble metal Au(111) and semiconductor Si(111) substrates by MBE method. To characterize the film, we have introduced several surface sensitive techniques including x-ray photoemission electron spectroscopy (XPS) and micro Raman spectroscopy. Also, crystallinity of the film has been confirmed by x-ray diffraction (XRD). Using home-built scanning tunneling microscope, we observed the atomic structure of quintuple layered Bi2Se3 film on Au(111).

  • PDF

3.0T MRI에서 온도변화가 T1 및 T2 이완시간에 미치는 영향 (Effect of Temperature on T1 and T2 Relaxation Time in 3.0T MRI)

  • 김호현;권순용;임우택;강충환;김경수;김순배;백문영
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.63-68
    • /
    • 2013
  • Purpose : The relaxation times of tissue in MRI depend on strength of magnetic field, morphology of nuclear, viscosity, size of molecules and temperature. This study intended to analyze quantitatively that materials' temperatures have effects on T1 and T2 relaxation times without changing of other conditions. Materials and Methods : The equipment was used MAGNETOM SKYRA of 3.0T(SIEMENS, Erlagen, Germany), 32 channel spine coil and Gd-DTPA water concentration phantom. To find out T1 relaxation time, Inversion Recovery Spin Echo sequences were used at 50, 400, 1100, 2500 ms of TI. To find out T2 relaxation time, Multi Echo Spin Echo sequences were used at 30, 60, 90, 120, 150, 180, 210, 240, 270 ms of TE. This experiment was scanned with 5 steps from 25 to $45^{\circ}C$. next, using MRmap(Messroghli, BMC Medical Imaging, 2012) T1 and T2 relaxation times were mapped. on the Piview STAR v5.0(Infinitt, Seoul, Korea) 5 steps were measured as the same ROI, and then mean values were calculated. Correlation between the temperatures and relaxation times were analyzed by SPSS(version 17.0, Chicago, IL, USA). Results : According to increase of temperatures, T1 relaxation times were $214.39{\pm}0.25$, $236.02{\pm}0.87$, $267.47{\pm}0.48$, $299.44{\pm}0.64$, $330.19{\pm}1.72$ ms. T2 relaxation times were $180.17{\pm}0.27$, $197.17{\pm}0.44$, $217.92{\pm}0.39$, $239.89{\pm}0.53$, $257.40{\pm}1.77$ ms. With the correlation analysis, the correlation coefficients of T1 and T2 relaxation times were statistically significant at 0.998 and 0.999 (p< 0.05). Conclusion : T1 and T2 relaxation times are increased as temperature of tissue goes up. In conclusion, we suggest to recognize errors of relaxation time caused local temperature's differences, and consider external factors as well in the quantitative analysis of relaxation time or clinical tests.

  • PDF