• 제목/요약/키워드: Spin inversion

검색결과 42건 처리시간 0.026초

Spin and shape analysis for the Mars-crossing asteroid 2078 Nanking

  • Choi, Jung-Yong;Kim, Myung-Jin;Choi, Young-Jun;Yoon, Tae Seog
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.85.2-86
    • /
    • 2015
  • The YORP effect is non-gravitational force that changes the spin-status of asteroid. So far this effect has been directly detected only from the Near-Earth asteroids (Taylor et al. 2007; Lowry et al. 2007, 2014; Breiter et al. 2011; Durech et al. 2008, 2012). Pravec at el. 2008 found the evidences for changing spin rate of small asteroids (3 - 15 km) by the YORP effect in the Main-Belt and Mars-crossing asteroids. The Mars-crossing asteroids (1.3 < q < 1.66 AU) are objects that cross orbit of the Mars. The Mars-crossing asteroids are regarded as one of the main sources for the Near-Earth asteroids. We expect that rotation of Mars-crossing asteroids would be influenced by the YORP effect. We try to search observational evidence of the YORP effect for the Mars-crossing asteroid. Our target 2078 Nanking is a population of the Mars-crossing asteroid. First light-curve of 2078 Nanking was obtained from Mohamed et al. 1994, and Warner et al. 2015 recently published new observational data. We observed this asteroid on 26th Nov. 2014 and 17th Jan. 2015 using SOAO (Sobaeksan Optical Astronomy Observatory) 0.61 m telescope with 4K CCD. Using light-curve inversion method (Kaasalainen & Torppa 2001; Kaasalainen et al. 2001), we try to determine the pole orientation and shape model of this asteroid based on the combination of our light-curve and literature photometric data. Knowing spin parameters, such as rotational period and spin axis, are essential for studying the YORP effect. In this presentation, we provide some preliminary results of our recent study: light-curve and processing of shape modeling of 2078 Nanking. We plan to find observational clue for the YORP effect on the Mars-crossing asteroids.

  • PDF

3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구 (A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study)

  • 이석준;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.253-259
    • /
    • 2015
  • 본 연구에서는 가돌리늄 조영제를 다양한 몰농도로 희석하여 T1 효과를 나타내는 펄스 시퀀스 중 고속스핀에코와 에코타임이 극도로 짧은 ultra short time echo에서 최대 신호 강도 분포를 나타내는 조영제 희석 몰농도를 3.0T에서 각각 알아보고자 하였다. T1 조영제인 gadoxetic acid 와 완충용액으로는 증류수, 2% agarose gel을 이용하여 다양한 몰농도로 조영제 팬텀을 제작하였다. 팬텀 제작의 정확성을 측정하기 위해 T1 이완시간 측정의 표준방식인 2D inversion recovery spine-echo 펄스시퀀스를 이용하였으며 팬텀의 중간 부의 한 개의 관상면 영상을 획득하여 T1 이완 시간을 계산하였다. 스핀에코에서는 1-2 mmol/L 조영제 몰농도에서 가장 높은 신호를 나타냈으며, ultra short time echo에서는 7 mmol/L에서 가장 큰 신호를 나타냈다. ultra short time echo 펄스 시퀀스를 이용한 조영증강 효과를 보기 위해서는 고속스핀에코 기법 보다 2-3배의 조영제 농도가 목적 장기에 유지하여야 하며 이와 관련된 조영제량 및 투여 방법의 연구가 이루어져야 한다.

흑혈류영상 획득 시 신호소실을 활용한 고속스핀에코기법의 유용성 (Effectiveness of a fast spin echo technique using the signal void in acquisition of black blood images)

  • 최관우;김윤신;손순룡;이희주;민정환;이종석;유병규
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4313-4319
    • /
    • 2013
  • 본 연구는 흑혈류영상 획득에서 고속스핀에코기법의 신호소실 현상을 이용하여 검사시간을 최소화시켜 환자의 불편을 줄이고 진단적 가치를 유지하고자 하였다. 연구방법은 흑혈류영상을 획득한 환자 32명을 대상으로, 기존의 이중역전회복기법과 새로운 기법인 고속스핀에코기법을 각각 적용한 후, 기법에 따른 혈류의 신호소거 차이를 알아보기 위해 T1, T2 강조영상에서 내경동맥 내강의 SNR과 CNR을 비교 평가하였다. 연구결과, SNR은 고속스핀에코기법이 이중역전회복기법 보다 T1, T2 강조영상에서 11.49%(4.73), 13.66%(6.03) 낮았으며, CNR은 고속스핀에코기법이 T1 강조영상에서 8.69%(15.04) 높았고, T2 강조영상에서 7.55% (13.17) 낮았으나, 통계적 수준에서 두 기법간의 SNR과 CNR의 차이는 유의하지 않았다. 그러므로 흑혈류영상 획득 시 고속스핀에코기법을 이용한다면 진단적 가치는 유지하면서 검사시간을 최소화하여 환자의 불편을 줄일 수 있다고 판단된다.

뇌피질 질환에서 뇌백질 신호 억제를 위한 중간시간 반전회복 영상 기법 (Medkum TAu Inversion Recover(MTIR) Sequence for White Matter Suppression in Brain Cortical Lesions)

  • 정경호;이정민;김종수
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권1호
    • /
    • pp.60-65
    • /
    • 1999
  • 목적 : 뇌백질 신호억제를 위한 중간시간 반전회복(Medium Tau Inversion Recovery, MTIR)영상에서 뇌회질과 뇌배질의 대조도를 다른 기법의 MR영상과 비교해 보고 뇌피질에 이상이 있는 환자에서 MTIR영상의 유용성을 평가하고자 하였다. 대상 및 방법 : 2명의 정상 지원자와 뇌피질 이형성증을 포함한 뇌피질 질환이 있는 21명을 대상으로 뇌회질과 뇌백질의 신호의 차이를 관심영역에서 대조도 백분율과 대조도 잡음비로 츠정하여 MTIR영상과 여러 가지 다른 MR영상을 비교하였다. 또한 시각적으로 병변이 뚜렷함, 새로운 병변의 발견여부를 시각적으로 비교 평가하였다. 결과 : MTIR영상은 다른 MR영상에 비해 대조도 백분율, 대조도 잡음비가 높아 뇌회질과 뇌백질의 신호의 차이가 가장 뚜렷하였다. 신경이주이상을 포함한 21명의 뇌피질 환자에서는 MTIR영상에서 다른 영상보다 병변이 뚜려사고 병변의 묘사(delineation)을 증가 시켰으나 새로운 병변은 발견하지 못해다. 결론 : MTIR영상은 뇌회질과 뇌백질의 대조도를 증가시키는 영상 기법이며 뇌피질을 침범한 질환을 특히 뇌피질 이형성증의 병변을 매우 잘 나타냈다. 기존의 T1강조영상 또는 3D-MPRAG에서 뇌피질-백질의 구별이 어려운 경우에는 보완적으로 이용가치가 있는 영상기법으로 생각된다.

  • PDF

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

3T 자기공명영상 장비에서 신생아 뇌의 T1 강조 영상: 스핀에코, 고속 역전회복, 자기화 삼차원 경사에코기법의 비교 (T1-weighted MR Imaging of the Neonatal Brain at 3.0 Tesla: Comparison of Spin Echo, Fast Inversion Recovery, and Magnetization-prepared Three Dimensional Gradient Echo Techniques)

  • 정지영;유소영;장경미;어홍;이정희;김지혜
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.87-94
    • /
    • 2007
  • 목적: 3T 장비의 신생아 뇌자기공명영상에서 T1 강조 고속 역전회복기법 (fast inversion recovery, FIR)과 자기화 삼차원 경사에코기법, (magnetization-prepared three dimensional gradient echo sequence, 3D GRE)을 스핀에코기법 (SE)과 비교하여 유용성을 알아보는 데 있다. 대상 및 방법: 20명의 신생아에서 T1 강조 SE, FIR, 그리고 3D GRE의 신호소음비 (SNR)와 대조소음비 (CNR)를 측정하고 시각적으로 회백질-백질 구별, 수초화 인식, 인공음영 발생을 점수화하여 비교하였다. 각 영상기법의 CNR 비교에는 Wilcoxon signed ranked test를 사용하였다. 결과: 세가지 영상기법 중 3D GRE가 가장 우수한 SNR을 보였고 CNR은 FIR과 3D GRE 모두 SE보다 우수하였으며 FIR보다 3D GRE가 더 우수하였다. 회백질-백질의 구분과 수초화 유무 역시 스핀에코보다 FIR과 3D GRE에서 더 잘 보였다. 그러나 3D GRE는 움직임에 의한 인공음영이 많았고 FIR에서 혈류에 의한 혈관의 고신호강도가 자주 발견되었다. 결론: 3T 장비에서 신생아 뇌영상을 얻을 때 FIR과 3D GRE 기법은 SE보다 좋은 T1 강조영상을 제공할 것으로 기대된다.

  • PDF

Comparison of Contrast-Enhanced T2 FLAIR and 3D T1 Black-Blood Fast Spin-Echo for Detection of Leptomeningeal Metastases

  • Park, Yae Won;Ahn, Sung Jun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.86-93
    • /
    • 2018
  • Purpose: Imaging plays a significant role in diagnosing leptomeningeal metastases. However, the most appropriate sequence for the detection of leptomeningeal metastases has yet to be determined. This study compares the efficacies of contrast-enhanced T2 fluid attenuated inversion recovery (FLAIR) and contrast-enhanced 3D T1 black-blood fast spin echo (FSE) imaging for the detection of leptomeningeal metastases. Materials and Methods: Tube phantoms containing varying concentrations of gadobutrol solution were scanned using T2 FLAIR and 3D T1 black-blood FSE. Additionally, 30 patients with leptomeningeal metastases were retrospectively evaluated to compare conspicuous lesions and the extent of leptomeningeal metastases detected by T2 FLAIR and 3D T1 black-blood FSE. Results: The signal intensities of low-concentration gadobutrol solutions (< 0.5 mmol/L) on T2 FLAIR images were higher than in 3D T1 black-blood FSE. The T2 FLAIR sequences exhibited significantly greater visual conspicuity scores than the 3D T1 black-blood sequence in leptomeningeal metastases of the pial membrane of cistern (P = 0.014). T2 FLAIR images exhibited a greater or equal extent (96.7%) of leptomeningeal metastases than 3D T1 black-blood FSE images. Conclusion: Because of its high sensitivity even at low gadolinium concentrations, contrast-enhanced T2 FLAIR images delineated leptomeningeal metastases in a wider territory than 3D T1 black-blood FSE.

지지체 투과저항과 코팅층의 두께가 PDMS 복합막의 에틸렌/질소의 투과성능에 미치는 영향 (Effect of Support Resistance & Coating Thickness on Ethylene/Nitrogen Separation of PDMS Composite Membranes)

  • 김정훈;최승학;박인준;이수복;강득주
    • 멤브레인
    • /
    • 제14권1호
    • /
    • pp.57-65
    • /
    • 2004
  • PDMS (polydimethylsiloxane) 복합막을 통한 기체분리 공정에서 다공성 지지체의 투과저항과 PDMS 코팅두께가 에틸렌/질소의 분리성능(투과도, 선택도)에 미치는 영향에 관하여 조사하였다. 이를 위해 Pinnau 등이 제시한 복합막 투과저항 모델이론식〔1〕이 사용되었다. 지지체의 투과도 또는 투과저항은 PES (polyethersulfone)/NMP(N-methyl-2-pyrrolidone) 고분자 용액의 농도를 변화시키면서 조절하였다. 복합막은 PES 지지체 위에 n-hexane에 녹인 2액형 PDMS 용액을 spin coater를 사용해 코팅하여 제조하였다. 선택층의 코팅 두께는 spin coater의 회전속도를 통해 조절하였다. 투과기체 분리특성은 단일기체 투과도 측정 장치를 통해 조사하였으며, 지지체 및 복합막의 단면구조 및 코팅두께는 SEM (scanning electron microscope)을 통하여 확인하였다 얻어진 실험결과는 복합막의 투과저항모델의 이론식과 매우 잘 일치함을 확인 할 수 있었다. 에틸렌/질소의 분리에 있어 PDMS 막 고유의 선택도를 얻기 위해서는 지지체의 투과저항과 코팅층의 최적화가 중요함을 확인하였다.

Solid-state NMR Studies of Miscibility and Morphology in Blends of Bisphenol-A type Polycarbonate and Poly (ester-ether) Elastomer

  • Kim, Yongae
    • 한국자기공명학회논문지
    • /
    • 제5권1호
    • /
    • pp.19-28
    • /
    • 2001
  • Miscibility and morphology in blends of bisphenol-A type polycarbonate and poly (ester-ether) elastomer with different compositions are studied by solid-state NMR spectroscopy. $^{13}$ C Solid-state NMR of CP/MAS/TOSS/DD, CP/MAS/DD, inversion recovery CP/MAS/DD, and 2D rotor driven spin diffusion techniques are used to identify the miscibility, morphology, and transesterification in blends. The blends of PC /BT elastomer with 15% to 42% of soft segment seem to be single phase miscible mixing and those of PC/PBT and PC/PBT elastomer with 62% of soft segment are cocontinuous two phase immiscible mixing. No significant transesterification reactions are observed in blends with different compositions.

  • PDF