• 제목/요약/키워드: Spin Test

검색결과 158건 처리시간 0.025초

해양용 로프의 내마모성에 관한 연구 (Study on Abrasion Resistance of Mooring Ropes)

  • 이은주;이창환;김주용
    • 한국염색가공학회지
    • /
    • 제22권4호
    • /
    • pp.373-379
    • /
    • 2010
  • The laboratory inspection and analysis of several types of ropes such as edge tensile test, D/d tensile test and abrasion test were carried out in order to investigate the abrasion degradation by external damage and to obtain the fundamental data for measurement against the abrasion. PET ropes were socketed and evaluated under tensile testing. A yarn-on-yarn abrasion test machine has been developed to study the damage and failure associated with rubbing between fiber surfaces. The abrasion test method consists of sliding a length of interwrapped yarn against itself in a reciprocating fashion, either dry or immersed in liquid. It has also been adapted to measure yarn-on-yarn friction. The influence of spin finish on yarn friction and abrasion was investigated extensively. This study indicates that finish has a major effect not only on yarn performance but also on rope performance under the marine environment.

FORMULATION AND STABILITY TEST OF ANTIAGING CREAM CONTAINING METHANOL FRACTION OIL OF PANGIUM EDULE.REINW. AS A RADICAL SCAVENGER AGENT

  • Djajadisastra, J.;Anwar, E.;Milani, E.
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book II
    • /
    • pp.303-306
    • /
    • 2003
  • Indonesia is a tropical country having a temperature range of 25-35$^{\circ}C$ which can affect the skin and causes damages like aging. This aging process is due, at least, to free radical reactions. For this reason, many attempts had been done to find out creams containing natural antioxidant compound which have a potential of free radical scavenger. Kluwek, a fermented form of foot ball fruit or picung (Pangium edule.Reinw), had been proved to contain antioxidant compound in its methanol fraction oil to which antiaging cream was formulated. Stability evaluation was conducted for cream with Kluwek oil compared to base cream, including organoleptic (colour and odour), pH, viscosity, particle size, centrifugation test and flow characteristics either in room temperature (27$^{\circ}C$) or stress condition (4$^{\circ}C$ and 5$0^{\circ}C$) for 8 weeks continuously, and six times cycling test at 4$^{\circ}C$ and 5$0^{\circ}C$ every 24 hours. The results showed that cream with Kluwek oil and base cream were stable at temperature 27 and 4$^{\circ}C$, cycling test and centrifugation test, but not stable at 5$0^{\circ}C$. Free radical evaluation was done by Electron Spin Resonance and the result showed that cream with Kluwek oil had less free radicals compared to base cream.

  • PDF

플라이휠 에너지 저장 장치용 복합재 로터 개발 (Development of a Composite Rotor for Flywheel Energy Storage System)

  • 김명훈;한훈희;김재혁;김성종;하성규
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.169-172
    • /
    • 2005
  • A flywheel system is an electromechanical energy storage device that stores energy by rotating a rotor. The rotating part, supported by magnetic bearings, consists of the metallic shaft, composite rims of fiber-reinforced materials, and a hub that connects the rotor to the shaft. The delamination in the fiber wound composite rotor often lowered the performance of the flywheel energy storage system. In this work, an advanced hybrid composite rotor with a split hub was designed to both overcome the delamination problem in composite rim and prevent separation between composite rim and metallic shaft within all range of rotational speed. It was analyzed using a three-dimensional finite clement method. In order to demonstrate the predominant perfom1ance of the hybrid composite rotor with a split hub, a high spin test was performed up to 40,000 rpm. Four radial strains and another four circumferential strains were measured using a wireless telemetry system. These measured strains were in excellent agreement with the FE analysis. Most importantly, the radial strains were reduced using the hybrid composite rotor with a split hub, and all of them were compressive. As a conclusion, a compressive pressure on the inner surface of the proposed flywheel rotor was achieved, and it can lower the radial stresses within the composite rotor, enhancing the performance of the flywheel rotor.

  • PDF

100Nm급 산업용 제어모멘트자이로 개발 (Development of 100Nm-class Control Moment Gyroscopes for Industrial Applications)

  • 이선호;김대관;김용복;용기력;최동수;박도환;김일종
    • 한국항공우주학회지
    • /
    • 제43권2호
    • /
    • pp.172-178
    • /
    • 2015
  • 제어 모멘트 자이로(control moment gyroscope, CMG)는 고토크 발생 장치로서 인공위성 뿐만 아니라 항공, 선박, 자동차, 로봇 등의 다양한 산업분야의 자세안정화와 기동 시스템에 적용될 수 있다. 본 논문은 여러 산업분야에서 적용할 수 있는 100Nm급 CMG 개발 전반에 대한 내용을 다룬다. 이를 위해서 CMG 시스템레벨 요구사항 분석, 모터 서브시스템 설계/제작/조립, 시험장치 구성, 성능시험 및 평가에 대한 개발과정과 결과를 제시한다. 스핀모터와 김벌모터를 설계조건에서 구동하여 CMG의 토크출력이 120Nm 이상 생성됨을 성능시험을 통해 확인한다.

Central Auditory Processing Tests as Diagnostic Tools for the Early Identification of Elderly Individuals with Mild Cognitive Impairment

  • Jalaei, Bahram;Valadbeigi, Ayub;Panahi, Rasool;Nahrani, Morteza Hamidi;Arefi, Hossein Namvar;Zia, Maryam;Ranjbar, Nastaran
    • Journal of Audiology & Otology
    • /
    • 제23권2호
    • /
    • pp.83-88
    • /
    • 2019
  • Background and Objectives: Mild cognitive impairment (MCI) is a disorder that usually occurs in the elderly, leading to dementia in some progressive cases. The purpose of this study is to examine the utility of central auditory processing tests as early diagnostic tools for identifying the elderly with MCI. Subjects and Methods: This study was conducted on 20 elderly patients with MCI and 20 healthy matched peers. The speech perception ability in a quiet environment and in the presence of background noise and also temporal resolution were assessed by using Speech Perception in Noise (SPIN) and Gap in Noise (GIN) tests, respectively. Results: The results indicated that the ability to understand speech in a quiet environment did not differ significantly between the two groups. However, SPIN at the three signal-to-noise ratios and the temporal resolution scores were significantly different between the two groups (p<0.001). Conclusions: Individuals with MCI appear to have poorer speech comprehension in noise and a lower temporal resolution than those of the same age, but without cognitive defects. Considering the utility of these tests in identifying cognitive problems, we propose that since the GIN test seems to be less influenced by intervening factors, this test can therefore, be a useful tool for the early screening of elderly people with cognitive problems.

Central Auditory Processing Tests as Diagnostic Tools for the Early Identification of Elderly Individuals with Mild Cognitive Impairment

  • Jalaei, Bahram;Valadbeigi, Ayub;Panahi, Rasool;Nahrani, Morteza Hamidi;Arefi, Hossein Namvar;Zia, Maryam;Ranjbar, Nastaran
    • 대한청각학회지
    • /
    • 제23권2호
    • /
    • pp.83-88
    • /
    • 2019
  • Background and Objectives: Mild cognitive impairment (MCI) is a disorder that usually occurs in the elderly, leading to dementia in some progressive cases. The purpose of this study is to examine the utility of central auditory processing tests as early diagnostic tools for identifying the elderly with MCI. Subjects and Methods: This study was conducted on 20 elderly patients with MCI and 20 healthy matched peers. The speech perception ability in a quiet environment and in the presence of background noise and also temporal resolution were assessed by using Speech Perception in Noise (SPIN) and Gap in Noise (GIN) tests, respectively. Results: The results indicated that the ability to understand speech in a quiet environment did not differ significantly between the two groups. However, SPIN at the three signal-to-noise ratios and the temporal resolution scores were significantly different between the two groups (p<0.001). Conclusions: Individuals with MCI appear to have poorer speech comprehension in noise and a lower temporal resolution than those of the same age, but without cognitive defects. Considering the utility of these tests in identifying cognitive problems, we propose that since the GIN test seems to be less influenced by intervening factors, this test can therefore, be a useful tool for the early screening of elderly people with cognitive problems.

3T에서 뇌 운동피질의 기능적 자기공명영상 연구 : Gradient-Echo와 Spin-Echo EPI의 비교 (Functional MR Imaging of Cerebral Motor Cortex on 3 Tesla MR Imaging : Comparison between Gradient and Spin-Echo EPI Techniques)

  • 구은회;장혜원;정환
    • 대한디지털의료영상학회논문지
    • /
    • 제9권2호
    • /
    • pp.31-38
    • /
    • 2007
  • To evaluate the accuracy and extent in the localization of cerebral motor coutex activation using a gradient- echo echo planar imaging(GE-EPI) compared to spin-echo echo planar iimaging(SE-EPI) on 3T MR imaging. Functional MR imaging of cerebral motor cortex activation was examined in GE-EPI and SE-EPI in five healthy male volunteers. A right finger movement was accomplished with a paradigm of 6 task and rest, periods and the cross-correlation was used for a statistical mapping algorithm. We evaluated any sorts of differenced of the time seried and the signal intensity changes between the rest and task periods obtained with two technoques. The qualitative analysis was distributed with activation sites of large veins and small veins by using two techniques and was found that both the techniques were clinically uesful for delineating large veins and small veins in fMRL Signal intensity charge of the rest and activation periods provided simmilar activations in both methods(GE-EPI : 0.93$\pm$0.11, SE-EPI : 0.80$\pm$.015) but the signal intensity in GE-EPI(133.95$\pm$15.76) was larger than in SE-EPI(74.5$\pm$18.90). The average SNRs of EPI raw data were higher at SMA in SE-EPI(48.54$\pm$12.37) than GE-EPI(41.4$\pm$12.54) and at M1 in SE-EPI(43.24$\pm$11.77) than GE-EPI(38.27$\pm$6.53). The localization of activation voxels of the GE-EPI showed a larger vein but the SE-EPI generally showed small vein. Then the analysis results of the two techniques were used for a statistacal paired student t-test. SE-EPI was found clinically useful for localizing the cerebral moter cortex cativation on 3.0T, but showed a little different activation patterns comparad to GE-EPI. In conclusion, SE-EPI may be feasible and can detect true cortical activation from capillaries and GE-EPI can obtain the large veins in the motor cortex activation on 3T MR imaging.

  • PDF

Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis

  • Se Woo Kim;Jeong Min Lee;Sungeun Park;Ijin Joo;Jeong Hee Yoon;Won Chang;Haeryoung Kim
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.180-188
    • /
    • 2022
  • Objective: To validate the performance of 3T spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) for staging hepatic fibrosis in a large population, using surgical specimens as the reference standard. Materials and Methods: This retrospective study initially included 310 adults (155 undergoing hepatic resection and 155 undergoing donor hepatectomy) with histopathologic results from surgical liver specimens. They underwent 3T SE-EPI MRE ≤ 3 months prior to surgery. Demographic findings, underlying liver disease, and hepatic fibrosis pathologic stage according to METAVIR were recorded. Liver stiffness (LS) was measured by two radiologists, and inter-reader reproducibility was evaluated using the intraclass correlation coefficient (ICC). The mean LS of each fibrosis stage (F0-F4) was calculated in total and for each etiologic subgroup. Comparisons among subgroups were performed using the Kruskal-Wallis test and Conover post-hoc test. The cutoff values for fibrosis staging were estimated using receiver operating characteristic (ROC) curve analysis. Results: Inter-reader reproducibility was excellent (ICC, 0.98; 95% confidence interval, 0.97-0.99). The mean LS values were 1.91, 2.41, 3.24, and 5.41 kPa in F0-F1 (n = 171), F2 (n = 26), F3 (n = 38), and F4 (n = 72), respectively. The discriminating cutoff values for diagnosing ≥ F2, ≥ F3, and F4 were 2.18, 2.71, and 3.15 kPa, respectively, with the ROC curve areas of 0.97-0.98 (sensitivity 91.2%-95.9%, specificity 90.7%-99.0%). The mean LS was significantly higher in patients with cirrhosis (F4) of nonviral causes, such as primary biliary cirrhosis (9.56 kPa) and alcoholic liver disease (7.17 kPa) than in those with hepatitis B or C cirrhosis (4.28 and 4.92 kPa, respectively). There were no statistically significant differences in LS among the different etiologic subgroups in the F0-F3 stages. Conclusion: The 3T SE-EPI MRE demonstrated high interobserver reproducibility, and our criteria for staging hepatic fibrosis showed high diagnostic performance. LS was significantly higher in patients with non-viral cirrhosis than in those with viral cirrhosis.

솔레노이드 코일을 이용한 전자 마이크로 펌프의 제작 및 시험 (Fabrication and Test of an Electromagnetic Micropump using Solenoid Coil)

  • 김기훈;김순영;정옥찬;양상식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권5호
    • /
    • pp.315-320
    • /
    • 2000
  • This paper presents the fabrication and test of a micropump with an electromagnetic actuator and a pair of aluminum flap valves. The actuator consists of a solenoid coil, a permanent magnet and an actuator diaphragm. The actuator diaphragm is fabricated by the spin coating of silicone rubber. The valve are passive ones and are fabricated by micromachining. The deflection of the fabricated actuator diaphragm is measured with a laser vibrometer. The deflection of the actuator diaphragm is proportional to the input current. The measured deflection of the fabricated diaphragm is $400 \mum$,/TEX> when the input is 118 mApp, and the cut-off frequency is 50 Hz. The maximum flow rate of the fabricated micropump with the electromagnetic actuator is about 5$0 \muell/min$ at 5 Hz when the input current and the duty ratio of the square was are 118 mApp and 50%, respectively.

  • PDF

Fabrication and Drive Test of a Peristaltic Thermopnumatic PDMS Micropump

  • Jeong Ok Chan;Park Sin Wook;Yang Sang Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.649-654
    • /
    • 2005
  • This paper presents fabrication and drive test of a peristaltic PDMS micropump actuated by the thermopneumatic force. The micropump consists of the three peristaltic-type actuator chambers with microheaters on the glass substrate and a microchannel connecting the chambers and the inlet/outlet port. The micropump is fabricated by the spin-coating process, the two-step curing process, the JSR (negative PR) molding process, and etc. The diameter and the thickness of the actuator diaphragm are 2.5 mm and $30{\mu}m$, respectively. The meniscus motion in the capillary tube is observed with a video camera and the flow rate of the micro pump is calculated through the frame analysis of the recorded video data. The maximum flow rate of the micropump is about $0.36\;{\mu}L/sec$ at 2 Hz for the zero hydraulic pressure difference when the 3-phase input voltage is 20 V.