• Title/Summary/Keyword: Spherical power

Search Result 306, Processing Time 0.021 seconds

Evaluation of Reliability for Combined Refractive Power of Lenses in an Automatic Phoropter (자동포롭터 내부렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2015
  • Purpose: To evaluate the reliability of refractive power by comparing the marked refractive power in an automatic phoropter and actually measured spherical/cylindrical refractive power. Methods: Actual refractive power of minus spherical lens and cylindrical lens in an automatic phoropter was measured by a manual lensmeter and compared with the accuracy of marked refractive power. Furthermore, combined refractive power and spherical equivalent refractive power of two overlapped lenses were compared and evaluated with the refractive power of trial lens. Results: An error of 0.125 D and more against the marked degree was observed in 70.6% of spherical refractive power of spherical lens which is built in phoropter, and the higher error was shown with increasing refractive power. Single cylindrical refractive power of cylindrical lens is almost equivalent to the marked degree. Combined spherical refractive power was equivalent to spherical refractive power of single lens when spherical lens and cylindrical lens were overlapped in a phoropter. Thus, there was no change in spherical refractive power by lens overlapping. However, there was a great difference, which suggest the effect induced by overlapping between cylindrical refractive power and the marked degree when spherical lens and cylindrical lens were overlapped. Spherical equivalent refractive power measured by using a phoropter was lower than that estimated by trial glasses frame and marked degree. The difference was bigger with higher refractive power. Conclusions: When assessment of visual acuity is made by using an automatic phoropter for high myopes or myopic astigmatism, some difference against the marked degree may be produced and they may be overcorrected which suggests that improvement is required.

The implementation of spherical acoustical holography (구형좌표계에서 음향 홀로그래피의 적용)

  • Kim, Yong-Joe;Cho, Yong-Thung;Bolton, J.Stuart
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.410-415
    • /
    • 2002
  • In this article, spatial filtering procedures with application to spherical acoustical holography are discussed. Planar and cylindrical holography are the most widely used amongst the various nearfield acoustical holography techniques. However, when the geometry of a source is similar to a sphere, spherical holography may yield better results than other types of holography since there are no errors due to truncation of the sound field in the spherical case. Spatial filtering affects the accuracy of spherical acoustical holography critically, especially in the case of backward projection. Thus spatial filtering is essential for successful application of spherical holography. In the present work, various filtering methods were evaluated in simulations made using sound pressure fields of various types and with different levels of random spatial noise. It was found that a procedure based on eliminating spherical harmonic coefficients that contribute insignificantly to the total sound power of the source gave the best results on average of the different procedures considered here. Spherical holography procedures were also verified experimentally. Reliable results were obtained using the power filtering algorithm. Thus it was concluded that spherical holography combined with power filtering may prove to be a useful tool for noise source identification.

  • PDF

Power Consumption for Double-Stage Paddle Impeller in Cylindrical and Spherical Agitated Vessels (원통 및 구형교반조에서의 2단 Paddle 임펠러에 대한 소요동력)

  • Lee, Young-Sei;Choi, Hyun-Kuk;Shida, Hirotaka
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.4
    • /
    • pp.247-253
    • /
    • 2006
  • Power consumption for double-stage paddle impeller in spherical and cylindrical agitated vessel was measured over a wide range of Reynolds number from laminar to turbulent flow regions. The power correlation was obtained which was applied to both spherical and cylindrical vessel, when the apparent diameter of the spherical vessel was equal to the diameter of the cylindrical vessel which had a height equal to its diameter and had the same volume as the spherical vessel. The power consumption for the double-stage impeller was dependent upon the distance of among the impeller in the agitated vessels, as follows: $$f/2={\frac{C_L}{Re_G}}+{\frac{Ct}{2}}({\frac{C_tr}{Re_g}}+Re_g)^{-m}$$

  • PDF

The Implementation of Spherical Acoustical Holography (구형좌표계에서 음향 홀로그래피의 적용)

  • Cho, Yong-Thug;J. Stuart Bolton;Kim, Yong-Joe
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.344.2-344
    • /
    • 2002
  • In this presentation, a power-based spatial filtering procedure with application to spherical acoustical holography is presented. Planar and cylindrical holography are the most widely used amongst the various nearfield acoustical holography techniques. However, when the geometry of a source is similar to a sphere. spherical holography may yield better results than other types of holography since there are no errors due to truncation of the sound field in the spherical case. (omitted)

  • PDF

Analysis of Refractive Error according to Aging in Young Children in South Korea (한국 어린이의 연령에 따른 굴절이상 분석)

  • Kim, Douk-Hoon;Kim, Dae-Nyoun
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose. to describe the prevalence of refractive error according to aging in young children in South Korea. Methods : From July 2013 to June 2014, five hundred subjects( 250 male subjects, 250 female subjects; aged between 7 and 12 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+2.00$ D, cylinder error ${\geq}0.75$ D and SE difference${\geq}1.00$ D between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 80.41%, astigmatism 44.89%, emmetropia 18.27%, anisometropia 16.92%, and hyperopia 1.32%. The prevalence of myopia increased with age. but hyperopia was decrease. Myopia and astigmatism were much more common in male than females although the difference was not statically significant. Emmetropia and hyperopia were much more common in female than males although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to 0.99 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between 9 year and 10 year of female in the spherical equivalent power(p>0.05). In all another group of age, there was not a statistical significance as aging in spherical equivalent power(p>0.5). However, there was a statistical significance between male and female as age in the spherical equivalent power(P>0.01). Conclusions: Myopia was the most common refractive error in Korea young children, while hyperopia was decreased after 7 years. There was a statistical significance as age between male and female at spherical equivalent power(P> 0.01). these results suggested that the analysis of the refractive error as age at young children can give the useful diagnosis data for the correction of visual function.

Analysis of a 3-Degree-of-Freedom Spherical Actuator using VCM Principle (보이스 코일 모터 방식을 이용한 3 자유도 구형모터의 분석)

  • Chu, Junghyun;Niguchi, Noboru;Hirata, Katsuhiro
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.207-215
    • /
    • 2017
  • The superior performance of the spherical actuator is establishing a new trend in the industry. Spherical actuators can perform multiple degrees-of-freedom (DOF) motions by using only one actuator. Therefore, a multi-DOF device using the spherical actuator can reduce weight and simplify the structure. This paper proposes a new spherical actuator that uses the operational principle of a rotational voice coil motor. The effectiveness of the actuator is verified through 3-D finite element method.

Analysis of Refractive Status between Urban and Rural Region in 13-year-old Children (도시와 농촌의 13세 어린이에 대한 굴절상태 분석)

  • Kim, Douk-Hoon;Kim, Jung-Sook
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.1
    • /
    • pp.808-815
    • /
    • 2017
  • Purpose. To analyze the refractive status between urban and rural regions, of children in Korea, in the age group of 13. Methods. From October 2016 to January 2017, forty subjects( 20 male subjects, 20 female subjects; 13 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+1.00D$, cylinder error ${\geq}0.75D$ and SE difference${\geq}1.00D$ between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 76.25%, astigmatism 35%, emmetropia 16.25%, anisometropia 8.75%, and hyperopia 5%. The prevalence of myopia and astigmatism were much more common in urban than rural region although the difference was not statically significant. Emmetropia and astigmatism were much more common in rural region than urban although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to -4.00 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between OD and OS of rural region in the spherical equivalent power(p<.000). Also, There was a statistical significance between OD and OS of urban region in the spherical equivalent power(p<.004). Therefore, there was a significant statistical similarity between urban and rural regions on the OD and OS in the spherical equivalent power. On the other hand, There was a significant statistical similarity between urban and rural regions of the OD and OS in the astigmatism power(p<0.000). However, in the rural and urban regions there was not statistical significance in the OD and OS concerning the spherical equivalent power and astigmatism power (p>0.1). Conclusions. Myopia was the most common refractive error in Korea young children. while hyperopia was few. There was not a statistical significance as age between rural and urban at spherical equivalent power( P> 0.01). These results suggested that the analysis of the refractive status at young children can give the useful diagnosis data for the correction of visual acuity.

Refractive Error in 7-9 Year-old Korea Children (7세부터 9세 사이의 한국인 어린이의 굴절 이상)

  • Kim, Douk-Hoon;Alberto, Mercedita O.
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.3
    • /
    • pp.203-208
    • /
    • 2014
  • Purpose. To analysis the refractive error in 7-9 year-old Korea children. Methods. From July 2013 to June 2014, two hundred eighty two subjects were performed in refraction test using the Auto-Refractometry. Results. The refractive error by spherical equivalent among all subjects was myopia 47.58%, emmetropia 42.35%, astigmatism 32.33%, and hyperopia 8.76%. Myopia was more common in female than males although the difference was not statically significant. The axis of astigmatism was with the rule in 65%, against the rule in 31.5%, and oblique in 3.5% There was a statistical significance between 7 year and 9 year of male in the spherical equivalent power(p=0.010). Also there was a statistical significance between 7 years and 9 years of female in the spherical equivalent power(p=0.036). However, there was not a statistical significance between male and female in spherical equivalent power(p>0.5). Conclusions. In this study, myopia was the most common refractive error. On the other hand, The prevalence of the axis of astigmatism was the with- the- rule. The spherical equivalent of refractive error was similar results between male and female. However The refractive error was different style with aging. these data suggested that the analysis of the refractive error at young children can provide the information of useful diagnosis for the correction of visual acuity.

An Inner-spherical Continuously Variable Transmission for Electric Bicycles

  • Park, Moon-Woo;Lee, Hyoung-Woo;Park, No-Gill
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.7-11
    • /
    • 2008
  • A new continuously variable transmission (CVT) for electric bicycles was developed using a traction drive mechanism with inner and outer spherical rotors. This electric bicycle CVT permits three propulsion modes: human-power only, motor-power only, or a combination of motor power and human power. In addition, the electric bicycle CVT has high power efficiency, large torque capacity, improved drivability, and good packageability. A prototype was manufactured based on a conceptual design, a performance analysis, and a detailed design. This prototype has a rated power of 250 W and input motor speed of 20 rad/s for an overall speed ratio in the range 0.3-1.2. A bench test was conducted to measure the power transmission performance of the prototype.

Study on the Analysis of Corneal Variation by Refractive Error (굴절이상에 의한 각막 변화도 분석에 관한 연구)

  • Lee, Hae-Jung;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.485-490
    • /
    • 2014
  • The purpose of this Study investigated corneal power, corneal astigmatism and corneal axis according to spherical equivalent of refractive error. We measured spherical equivalent, corneal power and corneal astigmatism in 100 subjects from January 2014 to July 2014. Measured spherical equivalent of refractive error were $-3.01{\pm}3.79D$, corneal power of $43.79{\pm}1.60D$ and corneal astigmatism of $-1.17{\pm}0.79D$ respectively. Prevalence of spherical equivalent of refractive error were as follows : myopes (61%), emmetropes (22%), hyperopes(17%). Corneal astigmatism of refractive error greater than +0.75D was 63% and prevalence of corneal astigmatism were as follows : with-the-rlue astigmatism (84.13%), against-the-rule astigmatism(9.52%) respectively. Corneal power by spherical equivalent increased from hyperopia to myopia. Between spherical equivalent of refractive error and the mean corneal power was significant correlation(r=-0.25, p=0.01). A correlation were found between corneal power and spherical equivalent of refractive error in adults. They have the highest distribution of prevalence myopia among the refractive error. When the refractive error was increased, we found that corneal power was steeper. It is recognized that this can be refractive error factor and correct visual function is considered.