• Title/Summary/Keyword: Spherical object prehension

Search Result 5, Processing Time 0.022 seconds

Development of Finger-force Measuring System with Six-axis Force/moment Sensor for Measuring a Spherical-object Grasping Force (6 축 힘/모멘트센서를 이용한 구물체 잡기 손가락 힘측정장치 개발)

  • Kim, Hyeon-Min;Yoon, Joung-Won;Shin, Hee-Suk;Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.37-45
    • /
    • 2010
  • Stroke patients can't use their hands because of the paralysis of their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by grasping a spherical object. At present, the used object in hospital is only a spherical object, and can't measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the spherical object measuring system which can measure the force of their fingers should be developed. In this paper, the finger-force measuring system with a six-axis force/moment sensor which can measure the spherical-object grasping force is developed. The six-axis force/moment sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP (digital signal processing). Also, the grasping force test of men was performed using the developed finger-force measuring system, it was confirmed that the average force of men was about 120N.

Development of finger-force measuring system with three-axis force sensor for measuring a spherical-object grasping force (3축 힘센서를 이용한 구물체 잡기 손가락 힘측정시스템 개발)

  • Kim, Hyeon-Min;Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.238-245
    • /
    • 2010
  • Stroke patients can't use their hands because of the paralysis of their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by grasping a spherical object. At present, the object used in hospital is only a spherical object, and can't measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the spherical object measuring system which can measure the force of their fingers should be developed. In this paper, the finger-force measuring system with a three-axis force sensor which can measure the spherical-object grasping force is developed. The three-axis force sensor is designed and fabricated, and the force measuring device is designed and manufactured using DSP(digital signal processing). Also, the grasping force test of men is performed using the developed finger-force measuring system, it was confirmed that the average force of men was about 120 N.

A Review of Hand Function (손 기능에 관한 고찰)

  • Lee, Sun-Myung
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.4
    • /
    • pp.155-168
    • /
    • 2002
  • The purpose of study to know hand function in order to prevent disability or handicap. The ability to perform precise refined movements of hand is an important human function. Improvement in object manipulation is common goal of therapist. The ability to manipulate an object in the hand is need for many functional tasks, including writing, handling coins, small objects and ADL skills. Therapists have commonly used hand grip and pinch strengths as baseline measures to evaluate hand function. The patterns of grasps are precision grasp, power grasp, hook grasp, spherical grasp, sylindrical grasp, disc grasp, pinch, three point pinch and tip pinch. And the motion of in-manipulation are finger to palm translation, palm to finger, shift, simple rotation and complex rotation. The hand function are include to evaluate of ROM, sensation, muscle strength of hand. It used to evaluate of decision of effect and suppose of disability and acceptance of vocation. Good evaluation is need to pretreatment and baseline of treatment and help to evaluate of effect on treatment.

  • PDF