• Title/Summary/Keyword: Spent air

Search Result 136, Processing Time 0.029 seconds

Effects of Brewer's spent grain (BSG) on larval growth of mealworms, Tenebrio molitor (Coleoptera: Tenebrionidae)

  • Kim, Sun Young;Kim, Hong Geun;Lee, Kyeong Yong;Yoon, Hyung Joo;Kim, Nam Jung
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.32 no.1
    • /
    • pp.41-48
    • /
    • 2016
  • Mealworms, Tenebrio molitor (Coleoptera: Tenebrionidae), are widely used as food sourcefor animal rearing as well as human diet. Conventionally, mealworms raised on wheat bran. In this study, we investigated the effects of brewer's spent grain (BSG) on the growth of mealworm larvae to reduce the rearing cost. We prepared five different diets with various BSG content, 0, 10, 30, 50, and 70% of heated air dried BSG with wheat bran. We compared survivorship, larval weight, developmental duration, pupation rate, and pupal weight of five different groups of T. molitor raised on these five diets. The larval survivorships were almost similar with the control group except a group with 70% of BSG. For the larval weight, groups with 30% and 50% of BSG gained more weight than that with control treatment, 0% of BSG. For the developmental period, the groups with 30% of BSG took less time compared to the control group. In all treatment groups, more than 90% of pupation rate were observed. Especially, the group with 30% of BSG showed highest pupation rate among the five groups. Wheat bran with 30~50% of BSG was the optimal diet for successive insect rearing among the five diet treatments. Based on this study, we concluded that adding BSG to wheat bran helps to improve the quality of T. molitor and to reduce the rearing period.

Use of the Spent Bleaching Earth from Palm Oil Industry in Non Fired Wall Tiles

  • Wangrakdiskul, Ubolrat;Khonkaew, Pimolwan;Wongchareonsin, Thanya
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.15-24
    • /
    • 2015
  • Currently, abundant wastes from the palm oil refining process have been generated which are hard to handle. Spent Bleaching Earth (SBE) is the solid waste from this process and leads the cost of elimination to the company. This study aims to utilize the SBE as the alternative material in the non-fired wall tiles. The main raw materials used in non-fired wall tiles consist of laterite soil, fluvial sand, and Portland cement. The experimental formulas have been conducted and divided into 3 groups by varying the percentage of the SBE in main raw materials. The specimens of material mixture have been produced by uniaxial pressing at 100 bars, dimensions in $50{\times}100{\times}8mm$. These specimens are sprayed with water and cured in the air for 7 days. After that, bending strength and water absorption test of these specimens has been performed. It can be concluded that the best formula with the percentage of laterite soil, fluvial sand, Portland cement, and SBE are 60.94%, 13.125%, 22.5%, and 3.435%, respectively. Its bending strength and %water absorption are 0.68 MPa and 5.64%. Material costs of specimen are approximately $0.00276 USD/100g. Furthermore, the comparison of curing period between 7 days and 30 days has been performed. The 30 days of curing period can improve the bending strength of the specimen, but there is no effect on water absorption.

NATURAL CONVECTION HEAT TRANSFER CHARACTERISTICS IN A CANISTER WITH HORIZONTAL INSTALLATION OF DUAL PURPOSE CASK FOR SPENT NUCLEAR FUEL

  • Lee, Dong-Gyu;Park, Jea-Ho;Lee, Yong-Hoon;Baeg, Chang-Yeal;Kim, Hyung-Jin
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.969-978
    • /
    • 2013
  • A full-sized model for the horizontally oriented metal cask containing 21 spent fuel assemblies has been considered to evaluate the internal natural convection behavior within a dry shield canister (DSC) filled with helium as a working fluid. A variety of two-dimensional CFD numerical investigations using a turbulent model have been performed to evaluate the heat transfer characteristics and the velocity distribution of natural convection inside the canister. The present numerical solutions for a range of Rayleigh number values ($3{\times}10^6{\sim}3{\times}10^7$) and a working fluid of air are further validated by comparing with the experimental data from previous work, and they agreed well with the experimental results. The predicted temperature field has indicated that the peak temperature is located in the second basket from the top along the vertical center line by effects of the natural convection. As the Rayleigh number increases, the convective heat transfer is dominant and the heat transfer due to the local circulation becomes stronger. The heat transfer characteristics show that the Nusselt numbers corresponding to $1.5{\times}10^6$ < Ra < $1.0{\times}10^7$ are proportional to 0.5 power of the Rayleigh number, while the Nusselt numbers for $1.0{\times}10^7$ < Ra < $8.0{\times}10^7$ are proportional to 0.27 power of the Rayleigh number. These results agreed well with the trends of the experimental data for Ra > $1.0{\times}10^7$.

Molybdenum release from high burnup spent nuclear fuel at alkaline and hyperalkaline pH

  • Sonia Garcia-Gomez;Javier Gimenez;Ignasi Casas;Jordi Llorca;Joan De Pablo;Albert Martinez-Torrents;Frederic Clarens;Jakub Kokinda;Luis Iglesias;Daniel Serrano-Purroy
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.34-41
    • /
    • 2024
  • This work presents experimental data and modelling of the release of Mo from high-burnup spent nuclear fuel (63 MWd/kgU) at two different pH values, 8.4 and 13.2 in air. The release of Mo from SF to the solution is around two orders of magnitude higher at pH = 13.2 than at pH = 8.4. The high Mo release at high pH would indicate that Mo would not be congruently released with uranium and would have an important contribution to the Instant Release Fraction, with a value of 5.3%. Parallel experiments with pure non irradiated Mo(s) and XPS determinations indicated that the faster dissolution at pH = 13.2 could be the consequence of the higher releases from metallic Mo in the fuel through a surface complexation mechanism promoted by the OH- and the oxidation of the metal to Mo(VI) via the formation of intermediate Mo(IV) and Mo(V) species.

Air Pollutant Emission Characteristics of a Light Duty Diesel Vehicle Affected by Road Infrastructure Improvement and Traffic flow Changes (도로 기반시설 개선과 교통흐름 변화에 따른 소형 경유자동차의 대기오염물질 배출특성)

  • keel, Jihoon;Lee, Taewoo;Lee, Sangeun;Jung, Sungwoon;Yun, Boseop;Kim, Jeongsoo;Choi, Kwangho
    • Journal of ILASS-Korea
    • /
    • v.21 no.4
    • /
    • pp.214-222
    • /
    • 2016
  • Changes in road infrastructure affect driving patterns and pollutant emission characteristics. we analyzed the changes in driving patterns and pollutant emission characteristics of the driving route via measured driving patterns at year 2009 and 2016. Since 2009, there has been an increase in population and traffic demand, including residential areas and industrial facilities. Traffic conditions were improved such as the opening of the highway Inter-Change to Seoul and the construction of underground driveway. As a result, the average vehicle speed increased. More detail comparisons have made on the changes of the underground driveway section and the crossroad section, which are expected to have significant changes in the transportation infrastructure. The vehicle speed distribution of the underground driveway changed from low speed to high speed, and the increase of the time spent at the high speed and high load caused the increase of NOx emissions. The vehicle speed also increased at the crossroad section, and the consequence NOx and $CO_2$ emissions decreased. It is mainly because the decreased time spent at idle, which results from the proper traffic demand management at this area.

Effect of Arrays of Impinging Jets with Crossflow on Heat/Mass Transfer (배열충돌제트에서 횡방향유동성분에 따른 열/물질전달 특성 고찰)

  • Yoon, Pil-Hyun;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.195-203
    • /
    • 2000
  • The local heat/mass transfer coefficients for arrays of impinging circular air jets on a plane surface are determined by means of the naphthalene sublimation method. Fluid from the spent jets is constrained to flow out of the system in one direction. Therefore, the spent fluid makes a crossflow in the confined space. The present study investigates effects of jet-orifice-plate to impingement-surface spacing and jet Reynolds number. The spanwise- and overall-averaged heat/mass transfer coefficients are obtained by numerical integrating the local heat transfer coefficients. The local maximum heat/mass transfer coefficients move further in the downstream direction due to the increase of crossflow velocity. At the mid-way between adjacent jets, the heat/mass transfer coefficients have a small peak owing to the collision of the adjacent wall jets and are affected strongly by the crossflow. The effect of the crossflow occurs strongly at the small orifice-to-impingement surface distance.

ANALYSIS ON FLOW FIELDS IN AIRFLOW PATH OF CONCRETE DRY STORAGE CASK USING FLUENT CODE (FLUENT를 활용한 콘크리트 건식 저장용기 공기유로 내부 유동장 해석)

  • Kang, G.U.;Kim, H.J.;Cho, C.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.47-53
    • /
    • 2016
  • This study investigated natural convection flow behavior in airflow path designed in concrete dry storage cask to remove the decay heat from spent nuclear fuels. Using FLUENT 16.1 code, thermal analysis for natural convection was carried out for three dimensional, 1/4 symmetry model under the normal condition that inlet ducts are 100% open. The maximum temperatures on other components except the fuel regions were satisfied with allowable values suggested in nuclear regulation-1536. From velocity and temperature distributions along the flow direction, the flow behavior in horizontal duct of air inlet and outlet duct, annular flow-path and bent pipe was delineated in detail. Theses results will be used as the theoretical background for the composing of airflow path for the designing of passive heat removal system by understanding the flow phenomena in airflow path.

Containment Evaluation of the KN-12 Transport Cask

  • Chung, Sung-Hwan;Choi, Byung-Il;Lee, Heung-Young;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.291-298
    • /
    • 2003
  • The KN-12 transport cask has been designed to transport 12 PWR spent nuclear fuel assemblies and to comply with the regulatory requirements for a Type B(U) package. The containment boundary of the cask is defined by a cask body, a cask lid, lid bolts with nuts, O-ring seals and a bolted closure lid. The containment vessel for the cask consists of a forged thick-walled carbon steel cylindrical body with an integrally-welded carbon steel bottom and is closed by a lid made of stainless steel, which is fastened to the cask body by lid bolts with nuts and sealed by double elastomer O-rings. In the cask lid an opening is closed by a plug with an O-ring seal and covered by the bolted closure lid sealed with an O-ring. The cask must maintain a radioactivity release rate of not more than the regulatory limit for normal transport conditions and for hypothetical accident conditions, as required by the related regulations. The containment requirements of the cask are satisfied by maintaining a maximum air reference leak rate of $2.7{\times}10^{-4}ref.cm^3s^{-1}$ or a helium leak rate of $3.3{\times}10^{-4}cm^3s^{-1}$ for normal transport conditions and for hypothetical accident conditions.

SPATIAL DISTRIBUTION OF FAECES BY CATTLE IN A DAYTIME GRAZING SYSTEM

  • Hirata, M.;Higashiyama, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.5
    • /
    • pp.603-610
    • /
    • 1996
  • Spatial distribution of faeces by Japanese Black heifers and steers was investigated. The animals grazed a bahiagrass (Paspalum notatum $Fl\ddot{u}gge$) pasture in the daytime from 9 a.m. to 4 p.m., and spent the rest of the day in a barn. The pasture consisted of three paddocks, an alley and a resting area, and the paddocks were grazed rotationally. The number of defecations and the faecal weight excreted in the pasture were greater than those expected from the proportion of time that the animals spent in the pasture. These values were correspondingly smaller in the barn. The distribution of faeces to the paddock, alley and resting area of the pasture was usually not proportional to the area of the respective places. The number of defeations and the faecal weight were usually distributed less densely in the paddock than in the resting area. The degree of aggregation of defecation in the paddock, alley and resting area varied with the meteorological factors such as the air temperature, solar radiation and rainfall during the grazing, and the intake of hay supplement of the previous day.

RADIATION MONITORING SYSTEM FOR ADVANCED SPENT FUEL CONDITIONING PROCESS FACITLITY

  • Kook Dong-Hak;Choung Won-Myung;Lee Eun-Pyo;You Gil-Sung;Cho Il-Je;Kwon Kie-Chan;Lee Won-Kyoung;Ku Jeoung-Hoe
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.149-155
    • /
    • 2005
  • The $ACP^1$ is under development for effective management of spent fuel by converting $UO_2$ into U-metal. For demonstration of this process, $\alpha-\gamma$ type new hotcell was built in the $IMEF^2$ basement. To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hotcell and service area at back of it. This system consists of 7 parts; Area Monitor for $\gamma$-ray, Room Air Monitor for particulate and iodine in both area, Hotcell Monitor for hotcell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration.

  • PDF