• 제목/요약/키워드: Speed regulation strategy

검색결과 19건 처리시간 0.027초

압력제어 방식 금속 벨트 CVT 변속비 제어 전략 (Control Strategy of Ratio Changing System for a Metal V-Belt CVT Adopting Primary Pressure Regulation)

  • 최득환;김현수
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.201-208
    • /
    • 2002
  • In this paper, the control strategy of ratio changing system for a metal belt CVT adopting primary pressure regulation is developed, and the shirting performance of pressure regulating type CVT with the suggested control strategy is investigated. The control strategy suggested in this study is composed of 2 feedback loop, one is speed ratio feedback and the other is primary pressure feedback. The pressure feedback is adopted to ensure prohibiting a belt slip during transient period in a fast downshift mode. Simulation results show that the system with suggested control strategy gives appropriate response time and tracking Performance for upshift and also gives a proper primary pressure which can prohibit the belt slip. In addition, it is fecund that the given system has an acceptable servo property in tracking the target speed ratio and robustness for the disturbance of line pressure.

계통 연계형 풍력 발전 시스템의 LVRT 제어 전략 (LVRT Control Strategy of Grid-connected Wind Power System)

  • 신호준;설승기
    • 전력전자학회논문지
    • /
    • 제16권2호
    • /
    • pp.182-190
    • /
    • 2011
  • 본 논문은 계통 전압 사고 상황에서 계통 연계형 풍력 발전 시스템이 만족시켜줘야 할 LVRT(Low Voltage Ride Through) 제어 전략을 제안한다. LVRT 규정은 계통 전압 사고 시 풍력 발전 시스템이 지켜야 할 부분들을 전압 감소율과 사고 시간에 대해 나타내고 있다. 특히 전압 감소율이 10% 이상일 경우에는 풍력 발전 시스템은 규정된 무효 전류를 전력 계통에 제공하여 계통 전압 확보에 이바지해야 한다. 본 논문에서의 LVRT 규정은 세계적으로 가장 엄격한 규정인, 독일 계통 연계 규정(German Grid Code)을 기준으로 하고 풀 스케일(Full-scale) 가변 속도 전력 변환 시스템을 고려하여 제어 전략을 수립한다. 본 LVRT 제어 전략은 계통 사고 시 LVRT 규정을 모두 만족시킴과 동시에 직류단 전압 제어의 추가적인 알고리즘으로 직류단 전압의 제어를 통하여 전체 풍력 발전 시스템의 전력 균형을 기할 수 있다. 3상 전압 지락 사고의 경우 계통으로의 전력 제어가 불가능하여 계통 측 컨버터가직류단 전압을 제어할 수 없으므로, 전력 제어의 기능을 발전기 측 인버터로 이행 시켜 상황에 따라 유연한 직류단 전압 제어가 가능함을 보였다. 시뮬레이션과 실험을 통해 LVRT 제어 전략의 타당성을 검증하였다.

A Robust Adaptive Control for Permanent Magnet Synchronous Motor Subject to Parameter Uncertainties and Input Saturations

  • Wu, Shaofang;Zhang, Jianwu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.2125-2133
    • /
    • 2018
  • To achieve high performance speed regulation, a robust adaptive speed controller is proposed for the permanent magnet synchronous motor (PMSM) subject to parameter uncertainties and input saturations in this paper. A nonlinear adaptive control is introduced to compensate the PMSM speed tracking errors due to uncertainties, disturbances and control input saturation constraints. By combining the adaptive control and the nonlinear robust control based on the interconnection and damping assignment (IDA) strategy, a new robust adaptive control is designed for speed regulation of PMSM. Stability and robustness of the closed-loop control system involved with the constrained control inputs rather than unconstrained control inputs are validated. Simulations for PMSM control in the presence of uncertainties and saturations nonlinearities show that the proposed approach is effective to regulate speed, and the average tracking error using the proposed approach is at least 32% smaller than the compared methods.

식스 스텝 운전을 이용한 선박용 DC 전력 시스템의 직류단 전압 제어 (DC Bus Voltage Regulation With Six-Step Operation in Maritime DC Power System)

  • 윤종훈;손영광;설승기
    • 전력전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.263-270
    • /
    • 2021
  • Active AC/DC converters with PWM operation are utilized to regulate rectified DC bus voltage of a permanent magnet synchronous generator in the maritime DC power system. A DC bus voltage regulation strategy that exploits the six-step operation is proposed in this study. Compared with that of the PWM operation, switching loss of the converter can be significantly reduced under the six-step operation. Moreover, conduction loss can also be reduced due to the high modulation index and reduced flux-weakening current of the six-step operation. A controller is used for the proposed DC bus voltage regulation strategy to verify its validity with the simulation and experimental setup. The simulation and the experimental test results showed that the converter loss reduces to a maximum of 70% and 19%, respectively.

An Fuzzy-based Risk Reasoning Driving Strategy on VANET

  • 이병관;정이나;정은희
    • 인터넷정보학회논문지
    • /
    • 제16권6호
    • /
    • pp.57-67
    • /
    • 2015
  • This paper proposes an Fuzzy-based Risk Reasoning Driving Strategy on VANET. Its first reasoning phase consists of a WC_risk reasoning that reasons the risk by using limited road factors such as current weather, density, accident, and construction, a DR_risk reasoning that reasons the risk by combining the driving resistance with the weight value suitable for the environment of highways and national roads, a DS_risk reasoning that judges the collision risk by using the travel direction, speed. and distance of vehicles and pedestrians, and a Total_risk reasoning that computes a final risk by using the three above-mentioned reasoning. Its second speed reduction proposal phase decides the reduction ratio according to the result of Total_risk and the reduction ratio by comparing the regulation speed of road to current vehicle's speed. Its third risk notification phase works in case current driving speed exceeds regulation speed or in case the Total_risk is higher than AV(Average Value). The Risk Notification Phase informs rear vehicles or pedestrians around of a risk according to drivers's response. If drivers use a brake according to the proposed speed reduction, the precedent vehicles transfers Risk Notification Messages to rear vehicles. If they don't use a brake, a current driving vehicle transfers a Risk Message to pedestrians. Therefore, this paper not only prevents collision accident beforehand by reasoning the risk happening to pedestrians and vehicles but also decreases the loss of various resources by reducing traffic jam.

Adaptive Sliding Mode Traffic Flow Control using a Deadzoned Parameter Adaptation Law for Ramp Metering and Speed Regulation

  • Jin, Xin;Eom, Myunghwan;Chwa, Dongkyoung
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.2031-2042
    • /
    • 2017
  • In this paper, a novel traffic flow control method based-on ramp metering and speed regulation using an adaptive sliding mode control (ASMC) method along with a deadzoned parameter adaptation law is proposed at a stochastic macroscopic level traffic environment, where the influence of the density and speed disturbances is accounted for in the traffic dynamic equations. The goal of this paper is to design a local traffic flow controller using both ramp metering and speed regulation based on ASMC, in order to achieve the desired density and speed for the maintenance of the maximum mainline throughput against disturbances in practice. The proposed method is advantageous in that it can improve the traffic flow performance compared to the traditional methods using only ramp metering, even in the presence of ramp storage limitation and disturbances. Moreover, a prior knowledge of disturbance magnitude is not required in the process of designing the controller unlike the conventional sliding mode controller. A stability analysis is presented to show that the traffic system under the proposed traffic flow control method is guaranteed to be uniformly bounded and its ultimate bound can be adjusted to be sufficiently small in terms of deadzone. The validity of the proposed method is demonstrated under different traffic situations (i.e., different initial traffic status), in the sense that the proposed control method is capable of stabilizing traffic flow better than the previously well-known Asservissement Lineaire d'Entree Autoroutiere (ALINEA) strategy and also feedback linearization control (FLC) method.

커먼레일 디젤기관에서 분사전략에 따른 성능 및 배출가스에 관한 연구 (A Study on Characteristics of Performance and Emission by CRDI Engine's Injection Strategy)

  • 엄동섭;고동균;나완용;이성욱
    • 한국분무공학회지
    • /
    • 제16권3호
    • /
    • pp.134-139
    • /
    • 2011
  • Recent research has focused on engine combustion technology as well as application of after-treatment in order to comply with emission regulation. However, it is much more efficient way to control emissions from engine itself and furthermore research on engine control will provide the direction of after-treatment technology in future. Furthermore, emission standard regulation for passenger diesel vehicles has been stringent compared to others and nano-particles will be included in EURO6 regulation in Europe and similar emission standard will be introduced in Korea. A 3.0 liter high speed diesel engine equipped with by CRDI system of 160MPa injection pressure, and an intake/exhaust system of V type 6 cylinder turbo-intercooler was applied. The injection duration and injection quantity, pilot injection types which are related to CRDI and air/fuel ratio control applied by EVGT were changed simultaneously. Standard experiment procedure constituted dilution apparatus and CPC system to collect nano-particles and these test results were compared with regulated materials of CO, HC, NOx and investigated their relations and characteristics of nano-particles.

직렬형 플러그인 하이브리드 전기 버스의 엔진 구동 전략에 따른 시뮬레이션 기반 연비 분석 (Analysis of Fuel Economy for Series Plug-in Hybrid Electric Bus according to Engine Operation Strategy Based on Simulation)

  • 김진성;이치범;박영일
    • 한국자동차공학회논문집
    • /
    • 제22권5호
    • /
    • pp.102-107
    • /
    • 2014
  • Because of high oil prices and emission gas problems, many governments tighten regulation of fuel economy and emission gas. For Passenger car, there are many researches for plug-in hybrid electric vehicles and they are being manufactured. On the other hand, there are few researches for plug-in hybrid electric bus that is heavy commercial vehicle. In this study, analysis of fuel economy for series plug-in hybrid electric bus according to engine operation strategy based on simulation is conducted. Forward simulator is developed using Autonomie. Engine operation strategies consist on constant engine operation strategy and engine on/off operation strategy. Considering the engine operation strategy, results of vehicle speed, engine operating points and fuel economy are obtained and analyzed. As a result, engine on/off operation strategy has more advantage than constant engine operation strategy in terms of fuel economy.

제어용 직류전동기의 정속도최적제어에 대한 해석적 연구 (An Analytical Study of the Optimal Constant Speed Regulation of a D.C Control Motor)

  • 장세훈;이양범
    • 전기의세계
    • /
    • 제26권6호
    • /
    • pp.48-54
    • /
    • 1977
  • The object of this work is to study the optimal control strategy of constant speed characteristics for a D.C control motor under influence of disturbance. In the course of the analysis, the linearization and time invariance schemes on motor dynamics are presumed throughout under certain prescribed conditions and the performance measure for optimality is assumed to be quadratic in state and the control effort, with the initial and final time specified. When the motor speed is deviated from a stationary operating point by any external disturbance, the optimal continuous feedback control law is investigated by the application of the calculus of variation and realizability of the required control meachanism is suggested. Finally, the comparative study of the speed reasponses of the motor, with and without the optimal control effort is also presented to confirm the obtained results.

  • PDF

Control and Implementation of Dual-Stator-Winding Induction Generator for Variable Frequency AC-Generating System

  • Bu, Feifei;Hu, Yuwen;Huang, Wenxin;Shi, Kai
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.798-805
    • /
    • 2013
  • This paper presents the control and implementation of the dual-stator-winding induction generator for variable frequency AC (VFAC) generating system. This generator has two sets of stator windings embedded into the stator slots. The power winding produces the VFAC power to feed the loads, and the control winding is connected to the static excitation controller to control the generator for output voltage regulation with speed and load variations. On the basis of the idea of power balance, an instantaneous slip frequency control (ISFC) strategy using the information of both the output voltage and the output power is used in this system. A series of experiments is carried out on a 15 kW prototype for verification. Results show that the system has good static and dynamic performance in a wide speed range, which demonstrates that the ISFC strategy is suitable for this system.