• Title/Summary/Keyword: Speed Deviation

검색결과 467건 처리시간 0.027초

수동필터를 이용한 고속전철 이선현상에 의한 전원외란 저감 (Reduction of Power Disturbance by Contact Loss Phenomenon of a High Speed Electric Train Using Passive Filters)

  • 장진영;진강환;강정남;박동규;김윤호
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.206-211
    • /
    • 2010
  • Since high-speed train is a dynamic load in which electric power is externally supplied, contact loss between the catenary and pantograph occurs. This phenomena including vibrations generates frequently irregular arcs, which, in turn causes EMI. Thus it is very important to develop the approach to reduce arc phenomenon by contact loss, as speed of electric railway vehicle increases. In case of an electric railway vehicle using electrical power, compared with diesel rolling stock, Power Line Disturbance(PLD) such as harmonics, transient voltage and current, Electromagnetic Interference(EMI), and dummy signal injection etc usually occur. In this study, the dynamic characteristics of a contact wire and a pantograph suppling electrical power to high-speed train are investigated with an electrical response point. To implement power line disturbance induced by contact loss phenomenon for high speed train operation, a hardware simulator which considers contact loss between contact wire and pantograph as well as contact wire deviation is developed. It is confirmed by the experiments that contact loss effect is largely dependent on voltage conditions when the contact loss occurs. Also, a passive filter is designed to reduce power disturbance and the designed system is verified by experiment.

Wind Attribute Time Series Modeling & Forecasting in IRAN

  • Ghorbani, Fahimeh;Raissi, Sadigh;Rafei, Meysam
    • 동아시아경상학회지
    • /
    • 제3권3호
    • /
    • pp.14-26
    • /
    • 2015
  • A wind speed forecast is a crucial and sophisticated task in a wind farm for planning turbines and corresponds to an estimate of the expected production of one or more wind turbines in the near future. By production is often meant available power for wind farm considered (with units KW or MW depending on both the wind speed and direction. Such forecasts can also be expressed in terms of energy, by integrating power production over each time interval. In this study, we technically focused on mathematical modeling of wind speed and direction forecast based on locally data set gathered from Aghdasiyeh station in Tehran. The methodology is set on using most common techniques derived from literature review. Hence we applied the most sophisticated forecasting methods to embed seasonality, trend, and irregular pattern for wind speed as an angular variables. Through this research, we carried out the most common techniques such as the Box and Jenkins family, VARMA, the component method, the Weibull function and the Fourier series. Finally, the best fit for each forecasting method validated statistically based on white noise properties and the final comparisons using residual standard errors and mean absolute deviation from real data.

부산 해안지역의 고농도 오존 발생 특성에 관한 연구 (Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea)

  • 전병일
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

부산 동삼동 지역의 지표오존농도 특성 연구 (A Study on the Characteristics of Surface Ozone Concentration at Dongsamdong, Pusan)

  • 전병일
    • 환경영향평가
    • /
    • 제8권2호
    • /
    • pp.21-29
    • /
    • 1999
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone and meteorological data of 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was highest in Spring(35.4ppb) and lowest in Winter(22.2ppb). Relative standard deviation indicating clearness of observation site was 0.42 that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong showed maximum at 15~16LST and minimum 07~08LST that typical pattern of ozone concentration. In ozone episode period(May 18~23, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface.

  • PDF

적외선 조사된 토양에 대한 열전달 모델 (Heat Transfer Model for Soil Irradiated by Infrared)

  • 강화석;이귀현;강위수;오재헌
    • Journal of Biosystems Engineering
    • /
    • 제21권4호
    • /
    • pp.449-455
    • /
    • 1996
  • The temperature distributions at various soil depths were predicted by heat transfer model during and after infrared irradiation on sand loam or loam soil. At each soil depth, predicted and measured temperature distributions were compared with using the mean relative percentage deviation and standard error. The mean relative percentage deviation was less than 10% between predicted and measured temperature distributions at each soil depth. Thus, it was concluded that the temperature distribution at each soil depth could be predicted satisfactorily by heat transfer model. Also, it is expected that these predicted temperature distributions can be used as basic information for determining the working speed of weeder and the size when the real weeder is constructed.

  • PDF

자기동조 적응제어를 이용한 여자제어기 설계에 관한 연구 (A Study on the Design of Excitation Controller using Self Tuning Adaptive Control)

  • 유현호;이상근;김준현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.375-378
    • /
    • 1991
  • This paper presents a design method of synchronous generator excitation controller using self-tuning PID algorithm. Controller parameter is determined by using adaptive control theory in order to maintain optimal operation of generator under the various operating conditions. To determine the optimal parameter of controller. minimum variance algorithm using the recursive leastsquare(RLS) indentification method is adopted and the difference between the speed deviation with weighted factor and voltage deviation is used as the input signal of adaptive controller, which provides good damping and conversion characteristics. The results tested on a single machine infinite bus system verify that the proposed controller has better dynamic performances than conventional controller.

  • PDF

시스템 안정도 향상을 위하여 SVC를 포함한 전력계통의 최적 GA-PI 제어기 설계 (A Design of Optimal GA-PI Controller of Power System with SVC to Improve System Stability)

  • 정형환;허동렬;이종민;주석민
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권2호
    • /
    • pp.63-71
    • /
    • 2000
  • This paper deals with a systematic approach to GA-PI controller design for static VAR compensator(SVC) using genetic algorithm(GA) to improve system stability. Genetic algorithms(GAs) are search algorithms based on the mechanics of natural selection and natural genetics. To verify the validity of the proposed method, investigated damping ratio of the eigenvalues of the electro-mechanical modes system with and without SVC. Also, we considered dynamic response of terminal speed deviation and terminal voltage deviation by applying a power fluctuation at heavy load, normal load and light to verify the robustness of the proposed. Thus, we proved usefulness of GA-PI controller design to improve the stability of single machine-bus with SVC system.

  • PDF

개선된 극점이동 적응제어 알고리즘을 이용한 전력계통 안정화장치의 다기계통 적용 (Application to a Multimachine Power System of Power System Stabilizer using Revised Pole Shift Adaptive Control Algorithm)

  • 이상근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.486-493
    • /
    • 2000
  • This paper presents an application to a multimachine power system of power system stabilizer using revised pole shift adaptive algorithm. Controller parameters are determined by using adaptive control theory in order to maintain optimal operation of generator under the various operating conditions. To determine the optimal parameters of controller and overcome the problem of pole placement algorithm, this paper presents pole shift algorithm revised pole shift factor. Also, the difference between the speed deviation with weighted factor and voltage deviation is used as the input signal of adaptive controller, which provides good damping characteristics. The results tested on a multimachine power system verify that the proposed controller has better dynamic and transient performance than conventional controller.

  • PDF

DEVELOPMENT OF ANODIC STRIPPING VOLTAMMETRY FOR THE DETERMINATION OF PALLADIUM IN HIGH LEVEL NUCLEAR WASTE

  • Bhardwaj, T.K.;Sharma, H.S.;Jain, P.C.;Aggarwal, S.K.
    • Nuclear Engineering and Technology
    • /
    • 제44권8호
    • /
    • pp.939-944
    • /
    • 2012
  • Deposition potential, deposition time, square wave frequency, rotation speed of the rotating disc electrode, and palladium concentration were studied on a Glassy Carbon Electrode (GCE) in 0.01M HCl for the determination of palladium in High Level Nuclear Waste (HLNW) by anodic stripping voltammetry. Experimental conditions were optimized for the determination of palladium at two different, $10^{-8}$ and $10^{-7}M$, levels. Error and standard deviation of this method were under 1% for all palladium standard solutions. The developed technique was successfully applied as a subsidiary method for the determination of palladium in simulated high level nuclear waste with very good precision and high accuracy (under 1 % error and standard deviation).

지속적으로 향상되는 공정에서 기하 조정 관리한계를 사용한 $\overline{X}$ 관리도 ([ $\overline{X}$ ] Chart with Geometrically Adjusted Control Limits under Continually Improving Processes)

  • 유미정;박창순
    • 품질경영학회지
    • /
    • 제34권4호
    • /
    • pp.125-132
    • /
    • 2006
  • An adjusted control limit of the $\overline{X}$ chart is proposed for monitoring the continually improving processes. The continual improvement of the process implies the decrease of the process variance, which is represented by a logistic curve. The process standard deviation is estimated by the exponentially weighted moving average of the sample standard deviations from the past to the current times. The control limits are adjusted by the estimated standard deviation at every sampling time. The performance of the adjusted control limit is compared with that of the standard control limits for various cases of the decreasing speed and size of the variance. The results show that the $\overline{X}$ chart with the adjusted control limits provides better performances for monitoring the small and moderate shifts in continually improving processes.