• Title/Summary/Keyword: Spectrum Quantification

Search Result 58, Processing Time 0.022 seconds

Measurement of Spectrum Quantification Using Spectrum Use Factor (스펙트럼 사용계수를 이용한 스펙트럼 정량화 측정)

  • Shin Yong-Seop;Hong Ic-Pyo;Kim Young-Soo;Park Han-Kyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.81-88
    • /
    • 2006
  • In this paper, spectrum use factor as the ratio between used spectrum bandwidth by the existing system and total spectrum resources at specific locations was derived and calculated. Spectrum use factor was also presented as a function of antenna patterns and transmitter power of existing systems. Real spectrum use factor was calculated for fixed radio station as a validity of this paper. With the results of this paper, we can use the spectrum more efficiently because the white space of spectrum space is replaced by the quantificated spectrum space.

Modification of the fast fourier transform-based method by signal mirroring for accuracy quantification of thermal-hydraulic system code

  • Ha, Tae Wook;Jeong, Jae Jun;Choi, Ki Yong
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.1100-1108
    • /
    • 2017
  • A thermal-hydraulic system code is an essential tool for the design and safety analysis of a nuclear power plant, and its accuracy quantification is very important for the code assessment and applications. The fast Fourier transform-based method (FFTBM) by signal mirroring (FFTBM-SM) has been used to quantify the accuracy of a system code by using a comparison of the experimental data and the calculated results. The method is an improved version of the FFTBM, and it is known that the FFTBM-SM judges the code accuracy in a more consistent and unbiased way. However, in some applications, unrealistic results have been obtained. In this study, it was found that accuracy quantification by FFTBM-SM is dependent on the frequency spectrum of the fast Fourier transform of experimental and error signals. The primary objective of this study is to reduce the frequency dependency of FFTBM-SM evaluation. For this, it was proposed to reduce the cut off frequency, which was introduced to cut off spurious contributions, in FFTBM-SM. A method to determine an appropriate cut off frequency was also proposed. The FFTBM-SM with the modified cut off frequency showed a significant improvement of the accuracy quantification.

Development of an uncertainty quantification approach with reduced computational cost for seismic fragility assessment of cable-stayed bridges

  • Akhoondzade-Noghabi, Vahid;Bargi, Khosrow
    • Earthquakes and Structures
    • /
    • v.23 no.4
    • /
    • pp.385-401
    • /
    • 2022
  • Uncertainty quantification is the most important challenge in seismic fragility assessment of structures. The precision increment of the quantification method leads to reliable results but at the same time increases the computational costs and the latter will be so undesirable in cases such as reliability-based design optimization which includes numerous probabilistic seismic analyses. Accordingly, the authors' effort has been put on the development and validation of an approach that has reduced computational cost in seismic fragility assessment. In this regard, it is necessary to apply the appropriate methods for consideration of two categories of uncertainties consisting of uncertainties related to the ground motions and structural characteristics, separately. Also, cable-stayed bridges have been specifically selected because as a result of their complexity and the according time-consuming seismic analyses, reducing the computations corresponding to their fragility analyses is worthy of studying. To achieve this, the fragility assessment of three case studies is performed based on existing and proposed approaches, and a comparative study on the efficiency in the estimation of seismic responses. For this purpose, statistical validation is conducted on the seismic demand and fragility resulting from the mentioned approaches, and through a comprehensive interpretation, sufficient arguments for the acceptable errors of the proposed approach are presented. Finally, this study concludes that the combination of the Capacity Spectrum Method (CSM) and Uniform Design Sampling (UDS) in advanced proposed forms can provide adequate accuracy in seismic fragility estimation at a significantly reduced computational cost.

The Quantification and Validation of Loxoprofen using Near-infrared(NIR) Spectrum Method (근적외부스펙트럼 측정법을 이용한 록소프로펜의 정량화 및 밸리데이션)

  • Choi, Sung-Up
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.396-401
    • /
    • 2014
  • In this study, we used NIR spectrum method instead of conventional HPLC method to shorten the analysis and manufacturing time of the loxoprofen products. Loxoprofen mixtures with other pharmaceutical additives were prepared and evaluated by the NIR spectrometer and the HPLC system. Validation of both methods was performed for specificity, accuracy and precision. NIR spectrometer method was validated and revealed proper results for the in-process quality control in the pharmaceutical field. In conclusion, NIR spectrometry can be replaced by HPLC method.

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Simultaneous Determination of Dictamine, Obacunone and Fraxinellone in Dictamnus dasycarpus cortex by HPLC-DAD (HPLC-DAD를 이용한 백선피의 Dictamine, Obacunone, Fraxinellone의 동시분석법 확립)

  • Song, Ji-Yeon;Lee, Min-A;Yoon, Jeong-Seon;Kim, Dea-Hyun;Kim, Seung-Hyun;Kim, Young-Choong;Sung, Sang-Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.323-327
    • /
    • 2010
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of dictamine, obacunone and fraxinellone was established for the quality control of traditional herb Dictamnus dasycarpus cortex. Separation and quantification were successfully achieved with a Shiseido C18 column ($5\;{\mu}m$, 4.6 mm I.D. ${\times}$ 250 mm) by gradient elution of a mixture of methanol and water at a flow rate of 1.0 ml/min. The diode-array UV/Vis detector (DAD) was used for the detection and the wavelength for quantification was set at 236 nm. The presence of dictamine, obacunone and fraxinellone in this extract was ascertained by retention time, spiking with each authentic standard and UV spectrum. All three compounds showed good linearity ($r^2$ > 0.999) in relatively wide concentration ranges. The R.S.D. recovery of each compound was 101.0~103.7% with R.S.D. values less than 1.0%. This method was successfully applied to the determination of contents of dictamine, obacunone and fraxitnellone in three commercial products of D. dasycarpus cortex. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial products.

Simultaneous Determination of Baicalin and Glycyrrhizin in Eul-Ja-Tang by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Park, Jung-Hyun;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-JIn;Kim, Young-Choong;Sung, Sang-Hyun
    • Natural Product Sciences
    • /
    • v.14 no.3
    • /
    • pp.147-151
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, baicalin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Eul-Ja-Tang (EJT). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, 4.6 mm I.D. ${\times}$ 150 mm) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/VIS detector (DAD) was used for the detection and the wavelength for quantification was set at 250 nm. The presence of baicalin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. Both baicalin and glycyrrhizin showed good linearity ($r^2$ > 0.999) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 5% and the limits of detection (LOD) were about 30 ng. The mean recovery of each compound was 99.5 - 101.2% with R.S.D. values less than 4.0%. This method was successfully applied to the determination of contents of baicalin and glycyrrhizin in three commercial products of EJT, which resulted in the difference in the contents of these compounds. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial EJT products.

Simultaneous Determination of Paeoniflorin and Glycyrrhizin in Sayuk-san by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Jeon, Min-Ji;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-Jin;Sung, Sang-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.23-27
    • /
    • 2009
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, paeoniflorin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Sayuk-san (SYS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}150mm$) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of paeoniflorin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. All two compounds showed good linearity ($r^2$>0.996) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.3% and the limits of detection (LOD) were less than 55.7 ng. The mean recovery of each compound was $102.3{\sim}111.1%$ with R.S.D. values less than 4.6%. This method was successfully applied to the determination of contents of paeoniflorin and glycyrrhizin in three commercial products of SYS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial SYS products.

Development of Analysis and Visualization Tool for Java Source Code Changes using Reverse Engineering Technique (역공학을 이용한 자바 소스 코드의 변화량 분석 및 시각화 도구 개발)

  • Kwon, Jin-Wook;Choi, Yun-Ja;Lee, Woo-Jin
    • The KIPS Transactions:PartD
    • /
    • v.19D no.1
    • /
    • pp.39-48
    • /
    • 2012
  • In order to quickly understand which changes of source codes have been made and to perform effective maintenance of a system, it is important to visualize the changed parts. Although there are many works for analyzing software changes, there are few works for visualizing both of the change types and change quantifications for Java based systems. In this paper, we propose a change analysis technique based on class diagram and provide a change visualization technique by using change quantification information. In order to check the structural changes in source codes, source codes are transformed to class diagrams by reverse engineering methods. On the class diagrams, the changes are analyzed and quantified by numbers. Based on the change quantification, the changes are visualized on the class diagram by color spectrum. By using visualization techniques, maintainers can easily recognize the code changes to reduce the cost and time of maintenance.

Effect of Neutron Energy Spectra on the Formation of the Displacement Cascade in ${\alpha}-Iron$

  • Kwon Junhyun;Seo Chul Gyo;Kwon Sang Chul;Hong Jun-Hwa
    • Nuclear Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.497-505
    • /
    • 2003
  • This paper describes a computational approach to the quantification of primary damage under irradiation and demonstrates the effect of neutron energy spectra on the formation of the displacement cascade. The development of displacement cascades in ${\alpha}-Iron$ has been simulated using the MOLDY code - a molecular dynamics code for simulating radiation damage. The primary knock-on atom energy, key input to the MOLDY code, was determined from the SPECTER code calculation on two neutron spectra. The two neutron spectra include; (i) neutron spectrum in the instrumented irradiation capsule of the high-flux advanced neutron application reactor (HANARO), and (ii) neutron spectrum at the inner surface of the reactor pressure vessel steel for the Younggwang nuclear power plant No.5 (YG 5). Minor differences in the normalized neutron spectra between the two spectra produce similar values of PKA energy, which are 4.7 keV for HANARO and 5.3 keV for YG 5. This similarity implies that primary damage to the components of the commercial nuclear reactors should be well simulated by irradiation in the HANARO. Moreover, the application of the MD calculations corroborates this statement by comparing cascades simulation results.