• Title/Summary/Keyword: Spectrum Data

Search Result 2,074, Processing Time 0.03 seconds

Accuracy Verification of Theoretical Models for Estimating Microwave Reflection from Rough Sea Surfaces (거친 바다표면의 마이크로파 반사 계산을 위한 이론적 모델 정확도 검증)

  • Park, Sinmyong;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.10
    • /
    • pp.788-793
    • /
    • 2017
  • This paper presents the verification of accuracies of theoretical models for calculating the microwave reflections from rough sea surfaces. First of all, the Pierson-Moskowitz ocean spectrum was used to generate the rough sea surfaces. Then the relationship between the significant wave heights, root-mean-square(RMS) heights and wind speed was derived by estimating the significant wave heights and RMS heights of the generated sea surfaces according to various wind speeds, and compared the derived relationship with other measurement data sets. The reflection coefficients of the sea surfaces were calculated by using a numerical method(the moment method). Then, the numerical results were compared with Ament model, PO(Physical Optics) model, GO(Geometrical Optics) model and B-M(Brown-Miller) model for various roughness conditions(wind speed) and incidence angles. It was found that the Ament model is not accurate except for a very low roughness conditions($kh_{rms}$<0.4, k is wavenumber and $h_{rms}$ is RMS height). It was also found that at incidence angles lower than $70^{\circ}$, the PO and the GO models agree well with the numerical results, while the B-M model agrees well with the numerical analysis results at incidence angles higher than $80^{\circ}$ for very rough sea surfaces with $kh_{rms}$>10.

Radiation Shielding Analysis on The Spent Fuel Storage Facility for the Extended Fuel Cycle (장주기(長週期) 핵연료(核燃料) 저장시설(貯藏施設)에서의 방사선차폐해석(放射線遮蔽解析))

  • Lee, Tae-Young;Ha, Chung-Woo;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.90-96
    • /
    • 1984
  • Estimated dose rates in spent fuel pool storage with the extended fuel cycle core management were reviewed and compared with design limit after calculation with the aid of DLC-23/CASK(22 n, 18 g) nuclear data and ANISN code. Radioactivity and gamma spectrum within spent fuel assemblies were calculated with ORIGEN code by extended fuel cycle model. In the calculation of dose rate, the fuel pool geometry was assumed to be infinite slab. Also, composition materials and radiation source within assemblies which are being stored in pool storage were assumed to be uniformly distributed throughout all the assemblies. As a result of culculation of dose rate from stored assemblies and waterborne radionuclides in pool water, the calculated dose rates appear to be lower than design basis limit under normal condition as well as abnormal condition.

  • PDF

Reinterpretation of the protein identification process for proteomics data

  • Kwon, Kyung-Hoon;Lee, Sang-Kwang;Cho, Kun;Park, Gun-Wook;Kang, Byeong-Soo;Park, Young-Mok
    • Interdisciplinary Bio Central
    • /
    • v.1 no.3
    • /
    • pp.9.1-9.6
    • /
    • 2009
  • Introduction: In the mass spectrometry-based proteomics, biological samples are analyzed to identify proteins by mass spectrometer and database search. Database search is the process to select the best matches to the experimental mass spectra among the amino acid sequence database and we identify the protein as the matched sequence. The match score is defined to find the matches from the database and declare the highest scored hit as the most probable protein. According to the score definition, search result varies. In this study, the difference among search results of different search engines or different databases was investigated, in order to suggest a better way to identify more proteins with higher reliability. Materials and Methods: The protein extract of human mesenchymal stem cell was separated by several bands by one-dimensional electrophorysis. One-dimensional gel was excised one by one, digested by trypsin and analyzed by a mass spectrometer, FT LTQ. The tandem mass (MS/MS) spectra of peptide ions were applied to the database search of X!Tandem, Mascot and Sequest search engines with IPI human database and SwissProt database. The search result was filtered by several threshold probability values of the Trans-Proteomic Pipeline (TPP) of the Institute for Systems Biology. The analysis of the output which was generated from TPP was performed. Results and Discussion: For each MS/MS spectrum, the peptide sequences which were identified from different conditions such as search engines, threshold probability, and sequence database were compared. The main difference of peptide identification at high threshold probability was caused by not the difference of sequence database but the difference of the score. As the threshold probability decreases, the missed peptides appeared. Conversely, in the extremely high threshold level, we missed many true assignments. Conclusion and Prospects: The different identification result of the search engines was mainly caused by the different scoring algorithms. Usually in proteomics high-scored peptides are selected and low-scored peptides are discarded. Many of them are true negatives. By integrating the search results from different parameter and different search engines, the protein identification process can be improved.

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

A Molecular Dynamics Simulation Study of Hydroxyls in Dioctahedral Phyllosilicates (분자동역학 시뮬레이션을 이용한 이팔면체 점토광물 수산기 연구)

  • Son, Sangbo;Kwon, Kideok D.
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.209-220
    • /
    • 2016
  • Clay minerals are a major player to determine geochemical cycles of trace metals and carbon in the critical zone which covers the atmosphere down to groundwater aquifers. Molecular dynamics (MD) simulations can examine the Earth materials at an atomic level and, therefore, provide detailed fundamental-level insights related to physicochemical properties of clay minerals. In the current study, we have applied classical MD simulations with clayFF force field to dioctahedral clay minerals (i.e., gibbsite, kaolinite, and pyrophyllite) to analyze and compare structural parameters (lattice parameter, atomic pair distance) with experiments. We further calculated vibrational power spectra for the hydroxyls of the minerals by using the MD simulations results. The MD simulations predicted lattice parameters and interatomic distances respectively deviated less than 0.1~3.7% and 5% from the experimental results. The stretching vibrational wavenumber of the hydroxyl groups were calculated $200-300cm^{-1}$ higher than experiment. However, the trends in the frequencies among different surface hydroxyl groups of each mineral was consistent with experimental results. The angle formed by the surface hydroxyl group with the (001) plane and hydrogen bond distances of the surface hydroxyls were consistent with experimental result trends. The inner hydroxyls, however, showed results somewhat deviated from reported data in the literature. These results indicate that molecular dynamics simulations with clayFF can be a useful method in elucidating the roles of surface hydroxyl groups in the adsorption of metal ions to clay minerals.

Liquid-Liquid Equilibria of Poly(4-vinylphenol)(PVPh)/Ethyl Acetate and PVPh/Butyl Acetate Solutions (Poly(4-vinylphenol)(PVPh)/Ethyl Acetate 및 PVPh/Butyl Acetate 용액계의 액-액 상평형)

  • Kim, Mi Kyung;Kim, Ki-Chang
    • Korean Chemical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.704-714
    • /
    • 2005
  • Phase separations of Poly(4-vinylphenol)(PVPh)/Ethyl Acetate and PVPh/Butyl Acetate solutions were measured using the thermal optical analysis (TOA) method. The experimental phase separation data were correlated with liquid-liquid equilibria relations based on PC-SAFT equation of state. The phase separations of these system showed the behaviors of LCST (lower critical solution temperature)-type. The measured cloud temperatures were lowered with increasing in molecular weights of polymer(PVPh), and cloud temperatures of PVPh/Ethyl Acetate solutions shifted to lower temperature regions, compared to the PVPh/Butyl Acetate solutions. Extents of cross-association between solvent molecule and polymer in the PVPh/Ethyl Acetate solutions were measured using the FT-IR spectrum analysis method, and cross-association parameters of PC-SAFT model were estimated from experimental extents of cross-association. By using the estimated cross-association parameters between PVPh and solvent molecule, binodal and spinodal curves of liquid-liquid equilibria in PVPh/Ethyl Acetate and PVPh/Butyl Acetate solutions were calculated from PC-SAFT equation of state. The calculated binodal curves of these system were shown to be well agreeable with the experimental cloud temperature curves.

On the Statistical Characteristics of Freak Wave Occurrence (Freak Wave 발생의 통계적 특성에 대하여)

  • Kim, Do-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.2
    • /
    • pp.138-145
    • /
    • 2011
  • In this paper time series wave data are simulated by the Monte Calo method using random numbers to generate random phases of the wave signal. The simulated wave signasl are used to study the characteristics of freak waves. Various sea states are represented by combinations of the significant wave height $H_s$ defined in the spectrum method and the significant wave steepness $S_s$. For a fixed value of $S_s$, the probability of the occurrence of the freak wave is decreased as $H_s$ increases. For a fixed value of $H_s$ the probability of the occurrence of the freak wave increases as $S_s$ increases. The average value of the maximum wave height increase as $S_s$ increases, but the average height of freak wave remains the same and the value approaches two times of $H_s$. For the fixed value of $S_s$, average kurtosis of wave elevation increases as $H_s$ increases, but for a fixed $H_s$, the average kurtosis decreases as $S_s$ increases. The average of abnormality index(AI) is around 2.11 irregardless of $H_s$ and $S_s$. The maximum value of AI lies between 2.5 - 3.0. Therefore it is conjectured that AI maximum due to linear focusing is 3.0.

THE NONDESTRUCTIVE MEASUREMENT OF THE SOLUBLE SOLID AND ACID CONTENTS OF INTACT PEACH USING VIS/NIR TRANSMITTANCE SPECTRA

  • Hwang, I.G.;Noh, S.H.;Lee, H.Y.;Yang, S.B.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.210-218
    • /
    • 2000
  • Since the SSC(soluble solid contents) and titratable acidity of fruit are highly concerned to the taste, the need for measuring them by non-destructive technology such as NIR(Visual and Near-infrared) spectroscopy is increasing. Specially, in order to grade the quality of each fruit with a sorter at sorting and packing facilities, technologies for online measurement satisfying the tolerance in terms of accuracy and speed should be developed. Many researches have been done to develop devices to measure the internal qualities of fruit such as SSC, titratable acidity, firmness, etc. with the VIS(Visual)/NIR(Near Infrared) reflectance spectra. The distributions of the SSC, titratable acidity, firmness, etc. are different with respect to the position and depth of fruit, and generally the VIS/NIR light can interact with fruit in a few millimeters of pathlength, and it is very difficult to measure the qualities of inner flesh of fruit. Therefore, to measure the average concentrations of each quality factor such as SSC and titratable acidity with the reflectance-type NIR devices, the spectra of fruit at several positions should be measured. Recently, the interest about the transmittance-type VIS/NIR devices is increasing. NIR light can penetrate through the fruit about 1/10-1/1,000,000 %. Therefore, very intensive light source and very sensitive sensor should be adopted to measure the transmitted light spectra of intact fruit. The ultimate purpose of this study was to develop a device to measure the transmitted light spectra of intact fruit such as apple, pear, peach, etc. With the transmittance-type VIS/NIR device, the feasibility of measurement of the SSC and titratable acidity in intact fruit cultivated in Korea was tested. The results are summarized as follows; A simple measurement device which can measure the transmitted light spectra of intact fruit was constructed with sample holder, two 500W-tungsten halogen lamps, a real-time spectrometer having a very sensitive CCD array sensor and optical fiber probe. With the device, it was possible to measure the transmitted light spectra of intact fruit such as apple, pear and peach. Main factors affecting the intensity of transmitted light spectra were the size of sample, the radiation intensity of light source and the integration time of the detector. Sample holder should be designed so that direct light leakage to the probe could be protected. Preprocessing method to the raw spectrum data significantly influenced the performance of the nondestructive measurement of SSC and titratable acidity of intact fruit. Representative results of PLS models in predicting the SSC of peach were SEP of 0.558 Brix% and R2 of 0.819, and those in predicting titratable acidity were SEP of 0.056% and R2 of 0.655.

  • PDF

The study of nondestructive evaluation method of paper records materials by NIR spectroscopy (근적외선 분광분석을 이용한 종이기록물의 비파괴 특성평가 연구)

  • Han, Yoon-Hee;Shin, Yong-Min;Park, Soung-Be;Nam, Sung-Un;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.304-311
    • /
    • 2010
  • Near Infrared Spectroscopy (NIRs) has been applied for rapid and nondestructive paper measurement by replacing the current destructive method to the property of paper. Current standard methods for the property of paper were pH, moisture, breaking length, and folding endurance, which data were compared with spectrum of FT-NIR spectrometer. Various paper products such as copy, envelope, white, newspaper, as well as old paper produced around 1960~1980 were used as the sample. The correlation ($R^2$) and standard error of prediction (SEP) results for breaking length, folding endurance, moisture and pH are $R^2$=0.914, SEP=0.508, $R^2$=0.926, SEP=0.281, $R^2$=0.941, SEP=0.931, pH $R^2$=0.949, SEP= -0.0631, respectively. This result show that NIRs can be applied to practical application for nondestructive analysis of paper records materials.

Analysis of Solar Irradiance Measurement From a Multi-Filter Radiometer At Kwangju, South Korea.

  • Ogunjobi, K.O.;Kim, Y.J.;He, Z.;Ryu, S.Y.
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.335-335
    • /
    • 2001
  • Direct-normal, total horizontal and diffuse horizontal irradiance data obtained from a multi-filter rotating shadowband radiometer over seven different wavelength bands (416nm, 151nm, 616nm, 675nm, 870nm and 940nm and the entire spectrum) has been analyzed at Kwangju, South Korea from June 1998 December 2000. The maximum hourly global radiation flux ranged from 0.44 MJ/$m^2$ to 2.68 MJ/$m^2$ at around 11:00-12:00 Hr local time while the maximum hourly diffuse radiation flux ranged from about 0.96 MJ/$m^2$ to 1.37 MJ/$m^2$. The maximum hourly direct irradiance ranged from 1.42 MJ/$m^2$ to 2.92 MJ/$m^2$ from June1998-2000. During the period under consideration, the average monthly global radiation recorded were 13.09 MJ/$m^2$/day, 10.58MJ/$m^2$/day and 9.78MJ/$m^2$/day for years 1998, 1999 and 2000 respectively, while the diffuse irradiance were 6.54 MJ/$m^2$/day, 5.33 MJ/$m^2$/day and 5.14 MJ/$m^2$/day for f998, 1999 and 2000 respectively. The direct irradiance values at the site were 11.63 MJ/$m^2$/day, 8.24MJ/$m^2$/day and 7.75 MJ/$m^2$/day for 1998, f999 and 2000 respectively. It was observed that each of the years has its own unique meteorological parameters that affect the quality and quantity of radiation received for each month. The annual average daily fractions of the diffuse to the global radiation (KD) were 0.51, 0.61 and 0.59 for years 1998, 1999 and 2000 respectively. Analysis indicated that the average daily KD ranged from 0.13 to a maximum value of 0.99 in May for irradiance measured at the broadband channel while the maximum and minimum KD value of 0.91 and 0.23 was recorded at wavelength band 870nm and 940nm in January and September respectively. The lowest average daily clearness index (Kt) value recorded was 0.03 in May (Spring) and the annual average daily clearness indexes are 0.45, 0.34 and 0.35 for years 1998, f999 and 2000 respectively. The frequency of clear days annually at Kwangju is 67.95%, 29.57% and 40.72% for years 1998, 1999 and 2000 respectively.

  • PDF