• Title/Summary/Keyword: Spectrum Analyzing

Search Result 309, Processing Time 0.029 seconds

Induced Activity and Space Dose Distribution from Medical Linear Accelerator (의료용(醫療用) 선형가속기(線型加速器)에 의한 산난공간(散亂空間) 선량분포(線量分布)와 유도방사능(誘導放射能))

  • Chu, Sung-Sil;Park, Chang-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 1986
  • It is important to measure and protect from the radiation space dose and induced activity at the high energy medical linear accelerator facilities. These are to consider the additional risk to patients undergoing treatment, machine operators and staff members. Measurements of the space dose distribution and induced radioactivity at the 18 MeV medical linear accelerator facility in the Yonsei Cancer Center. 1. Exposure space dose for 300 rads monitor doses of 18 MeV electron are measured as 50 mR at 1 meter from patients. 2. Exposure space dose for 300 rads monitor doses of 10 MV X-ray are detected as 350 mR at 1 meter from phantom. 3. Induced radioactivity by photonuclear reaction was measured as 0.65 mR/hr from collimater after 30 Gy(3,000 rads) irradiated. 4. Analyzing the decay curves and energy spectrum of induced radioactivity, detected a few materials to be activated by photoneutron reaction, $^{65}Cu({\gamma}{\cdot}n)\;^{64}Cu,\;^{186}W({\gamma}{\cdot}n)\;^{185}W,\;^{181}Ta({\gamma}{\cdot}n)\;^{180}Ta,\;^{199}Au({\gamma}{\cdot}n)\;^{198}Au$.

  • PDF

ANALYSIS OF OPTICAL TRANSMISSION CHARATERISTICS BY VISIBLE LIGHT INTO SHADE GHIDES (가시광선영역에서 shade guide에 따른 광투과도 특성 연구)

  • Choi, Keun-Bae;Park, Charn-Woon;Song, Chang-Yong;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.147-159
    • /
    • 2000
  • The purpose of this study was the evaluation of spectral transmission of the commercial three shade guides and the relationship of hue, value, and chroma according to the transmission rate. The spectral transmittance of three shade guides - Vita Lumin Shade Guide, Vintage and Unibond Shade Guide, and Vitapan 3D-Master Shade Guide - were measured. For direct transmission measurements, each shade tabs were placed at the entrance port of the 1mm diameter intergrating sphere. The intensity of the light source passing through the shade tabs to the right angle was continuously recorded for wavelength from 400 to 700 nm. A transmission spectrum and digital data were obtained for each measurement and they were evaluated using Microcal Origin program. The obtained results of this study were as follows : 1. In Vita Lumin Shade Guide, sum of the transmission rate of the shade tabs at the wavelength 400-700nm was decreased in agreement with the arrangement order at each A, B, C, D group, except D4 shade tab. However, there were no relationships between the transmission rate of the shade tabs and the value-oriented. 2. In Vintage and Unibond Shade Guide, sum of the total transmission rate of the shade tabs was decreased in agreement with the arrangement order at each A, B, C, B group. When all shade tabs arranged in value-oriented, transmission rate was accord with the order, except D4 shade tab. 3. When shade tabs of the Vitapan 3D-Master Shade Guide have the same value and hue, sum of their total transmission rate decreased in accordance with the chroma-oriented. When the shade tabs have the same value and chroma, there were no differences from the order of the transmission rate to the various hue type. However, in the 'R' tabs of reddish hue type, the transmission rate increased at the long wavelength range area. In conclusion, we need the quantitative analyzing instruments in transmission determination. Vitapan 3D-Master Shade Guide covers the tooth color space taking into account the parameters of the systematic value, chroma, hue oriented, and the transmission rate relatively accorded with that sequence.

  • PDF

Performance and Jitter Effects Analysis of Single Bit Electro-Optical Sigma-Delta Modulators (단일 비트 전자-광학 시그마-델타 변조기의 성능 및 지터 효과 분석)

  • Nam, Chang-Ho;Ra, Sung-Woong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.706-715
    • /
    • 2012
  • Electro-optical sigma-delta modulators are the core module of digital receiver to digitize wideband radio-frequency signals directly at an antenna. Electro-optical sigma-delta modulators use a pulsed laser to oversample an input radio-frequency signals at two Mach-Zehnder Interferometer(MZI) and shape the quantization noise using a fiber-lattice accumulator. Decimation filtering is applied to the quantizer output to construct the input signal with high resolution. The jitter affects greatly on reconstructing the original input signal of modulator. This paper analyzes the performance of first order single bit electro-optical sigma-delta modulator in the time domain and the frequency domain. The performance of modulator is analyzed by using asynchronous spectral averaging of the reconstructed signal's spectrum in the frequency domain. The reference value of time jitter is presented by analyzing the performance of jitter effects. This kind of jitter value can be used as a reference value on the design of modulators.

Dual Component Analysis for In Vivo T2* Decay of Hyperpolarized 13C Metabolites

  • Joe, Eunhae;Lee, Joonsung;Lee, Hansol;Yang, Seungwook;Choi, Young-Suk;Wang, Eunkyung;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Purpose: To investigate the exchange and redistribution of hyperpolarized $^{13}C$ metabolites between different pools by temporally analyzing the relative fraction of dual $T_2{^*}$ components of hyperpolarized $^{13}C$ metabolites. Materials and Methods: A dual exponential decay analysis of $T_2{^*}$ is performed for [1-$^{13}C$] pyruvate and [1-$^{13}C$] lactate using nonspatially resolved dynamic $^{13}C$ MR spectroscopy from mice brains with tumors (n = 3) and without (n = 4) tumors. The values of shorter and longer $T_2{^*}$ components are explored when fitted from averaged spectrum and temporal variations of their fractions. Results: The $T_2{^*}$ values were not significantly different between the tumor and control groups, but the fraction of longer $T_2{^*}$ [1-$^{13}C$] lactate components was more than 10% in the tumor group over that of the controls (P < 0.1). The fraction of shorter $T_2{^*}$ components of [1-$^{13}C$] pyruvate showed an increasing tendency while that of the [1-$^{13}C$] lactate was decreasing over time. The slopes of the changing fraction were steeper for the tumor group than the controls, especially for lactate (P < 0.01). In both pyruvate and lactate, the fraction of the shorter $T_2{^*}$ component was always greater than the longer $T_2{^*}$ component over time. Conclusion: The exchange and redistribution of pyruvate and lactate between different pools was investigated by dual component analysis of the free induction decay signal from hyperpolarized $^{13}C$ experiments. Tumor and control groups showed differences in their fractions rather than the values of longer and shorter $T_2{^*}$ components. Fraction changing dynamics may provide an aspect for extravasation and membrane transport of pyruvate and lactate, and will be useful to determine the appropriate time window for acquisition of hyperpolarized $^{13}C$ images.

Fluorescence Detection for Protoporphyrin IX Induced from 5-ALA and ALA-methyl ester in Incubated Liver Cancer Cells (간암 세포주에서 5-ALA 및 ALA-methyl ester에 의해 유도된 Protoporphyrin IX의 형광 검출)

  • Kim, Myung-Hwa;Kim, Jung-Mi;Kim, Hyun-Jeong;Lee, In-Seon;Kim, Kyung-Chan;Lee, Chang-Seop
    • KSBB Journal
    • /
    • v.22 no.3
    • /
    • pp.168-173
    • /
    • 2007
  • To clarify the usefulness of fluorescent diagnosis for cancer, we investigated the optimal method of administrating 5-aminolevulinic acid (5-ALA), 5-aminolevulinic acid methyl ester (ALA-methyl ester) by analyzing fluorescence signal of Protoporphyrin IX (PpIX) in the cultured normal and cancer cells. 5-ALA and ALA-methyl ester was injected as a photosensitizer to the cancer liver cells (HepG2) and normal liver cells (Chang). Chang and HepG2 cells were incubated with various concentrations of 5-ALA and ALA-methyl ester (0-800 ${\mu}g/mL$). The accumulation of PpIX induced by 5-ALA and ALA-methyl ester was in HepG2 and Chang. The cell viability was measured by MTT assay. Fluorescence of PpIX in HepG2 cell was excited at a wavelength ($\lambda$ = 410 nm) and showed an emission spectrum at 603.2 nm, 660.8 nm and 603.2 nm, 661.4 nm which could be related to the PpIX generation induced by the applied 5-ALA and ALA-methyl ester, respectively. The experimental results showed that fluorescence signal of PpIX was proportional to the concentration of 5-ALA and ALA-methyl ester in tumor cells, but measured with low concentration in normal cells. Another results showed that the PpIX formation rate induced by ALA-methyl ester is higher than that of 5-ALA.

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

Confirming Animal Glue in Dancheong Sample by Pyrolysis/GC/MS (열분해/GC/MS에 의한 재현 단청 시편에서 아교의 확인)

  • Park, Jong Seo;Kim, Mi Jeong;Kim, Soon Kwan
    • Journal of Conservation Science
    • /
    • v.32 no.1
    • /
    • pp.21-32
    • /
    • 2016
  • Animal glue is a traditional material used extensively as adhesive and binder in mother-of-pearl, wooden structure, traditional painting, etc. Analysis of animal glue is usually performed with IR(infrared spectroscopy) based on the IR absorption of functional group. But, it has a limitation in confirming animal glue when a sample consists of several materials because of overlapping of the absorption band. Py/GC/MS(pyrolysis/gas chromatography/mass spectrometry) is a useful tool in analyzing the constituent of polymeric materials like animal glue by identifying their pyrolysate with very small amount of sample. In this study, confirmation of animal glue in a Dancheong sample was tried with this method. Characteristic pyrolytic compounds of animal glue and tung oil used in Dancheong were identified. Dancheong sample painted with Noerok as a coloring material, animal glue and tung oil was prepared and it was possible to find characteristic peaks of animal glue after thermal degradation and artificial weathering experiment. From this, we found that animal glue can be detected using py/GC/MS in cultural heritage samples consisting of several materials and in different condition. IR was also tried to analyze Dancheong sample and the results were compared with those of py/GC/MS for the detection of animal glue.

Effective Feature Vector for Isolated-Word Recognizer using Vocal Cord Signal (성대신호 기반의 명령어인식기를 위한 특징벡터 연구)

  • Jung, Young-Giu;Han, Mun-Sung;Lee, Sang-Jo
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.3
    • /
    • pp.226-234
    • /
    • 2007
  • In this paper, we develop a speech recognition system using a throat microphone. The use of this kind of microphone minimizes the impact of environmental noise. However, because of the absence of high frequencies and the partially loss of formant frequencies, previous systems developed with those devices have shown a lower recognition rate than systems which use standard microphone signals. This problem has led to researchers using throat microphone signals as supplementary data sources supporting standard microphone signals. In this paper, we present a high performance ASR system which we developed using only a throat microphone by taking advantage of Korean Phonological Feature Theory and a detailed throat signal analysis. Analyzing the spectrum and the result of FFT of the throat microphone signal, we find that the conventional MFCC feature vector that uses a critical pass filter does not characterize the throat microphone signals well. We also describe the conditions of the feature extraction algorithm which make it best suited for throat microphone signal analysis. The conditions involve (1) a sensitive band-pass filter and (2) use of feature vector which is suitable for voice/non-voice classification. We experimentally show that the ZCPA algorithm designed to meet these conditions improves the recognizer's performance by approximately 16%. And we find that an additional noise-canceling algorithm such as RAST A results in 2% more performance improvement.

Psychology analyzing system using spectrum component density ratio of EEG based on BCI-TAT (EEG 대역별 스펙트럼 활성 비를 활용한 BCI-TAT 기반 심리 분석 시스템)

  • Shin, Jeon-Hoon;Jin, Sang-Hyeon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.112-124
    • /
    • 2010
  • Studies that can find resolutions to problems of subjective psychiatric analysis must be performed and indeed they are in the process. However there still lies many problems in researches of mentality examination, which should be the foundation of finding potential resolutions. One of the biggest problems in the conventional system is that there are many different opinions by psychiatrists depending on their educations and experiences. There is no objective standard on the subjects and there is no effective psychiatric analysis method. Also, the characteristic of such examinations is that it cannot be applied to disabilities, foreigners and infants alyce the examination is ch examinconversation. The objective of this atudy is to standardize TAT(Thematic Apperception Test)analysiBallken index method so that subjective data from the examination can be excluded and the examination thus maklysithe examination objectified. Furthermore, objective result and patients' brain wave pattern is read with BCI(Brain Computer Interface) ch exaTherenvironment to Alsare it to brain wave characteristics vectors to reate brain-wave characteristics vector DB. Therefore, such DB can be utilize durlysithe examination and diagnosis to reate objective examination method and standardized diagnosis system. Thus, mentality examination can be performed only with brain-wave scans with BCI based TAT system.

Optical Properties of Opal Glass on the Various Contents of Chemical Composition

  • Nguyen, Tuan Dung;N., Bramhe Sachin;Kim, Ji Ho;Kim, Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2013
  • Opal glass samples having different chemical compositions were synthesized and transparent glass was obtained after melting. The effects of $TiO_2$, $BaF_2$, and $CeO_2$ content on the color of the opal glass were studied by observing images of the opal samples and analyzing the results via ultraviolet visible spectroscopy and color spectrometry. The aesthetic properties of the opal glass were determined by studying the transmittance of visible light in the 400 nm to 700 nm range. The basic chemical composition of opal glass was $SiO_2$ 52.9 wt%, $Al_2O_3$ 12.35 wt%, $Na_2CO_3$ 15.08 wt%, $K_2CO_3$ 10.35 wt%, $Ca_3(PO)_4$ 4.41 wt%, $MgCO_3$ 1.844 wt%, $LiCO_3$ 2.184 wt%, and $TiO_2$ 0.882 wt%. The glass samples were prepared by varying the weight percentage of $TiO_2$, $BaF_2$, and $CeO_2$. The transmittance of visible light was decreased from 95 % to 75 % in the glass samples in which $TiO_2$ content was increased from 0 to 3.882 wt%. In the blue spectrum region, as the content of $TiO_2$ increased, the reflectance value was observed to become higher. This implies that $TiO_2$ content induces more crystal formation and has an important effect on the optical properties of the glass. The opalescence of opal samples that contained $CeO_2$ or $BaF_2$ is stronger than that in the samples containing $TiO_2$. Opal glass samples comprising $TiO_2$ had tetragonal lattice structures; samples including $CeO_2$ as an additive had cubic lattice structures (FCC, $CeO_2$).