• Title/Summary/Keyword: Spectrum Analyzer

Search Result 261, Processing Time 0.027 seconds

Design of Lung Sound Analyzer Using Adaptive Digital Filter and DSP Chip (적응 디지탈 필터와 DSP 칩을 이용한 폐음 분석기 설계)

  • 김규한;조일준
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.151-156
    • /
    • 1989
  • Lung sound analyer which can provide an objective diagnosis of patients with pulmonary and bronchial disorders is designed. For the purpose of power spectrum analysis, adaptive digital filtering technique and TM - S320C25 DSP chip is used. As a results, adaptive lattice Wiener filter could eliminate heart sounds with a few of 10th order and on the distribution of power spectrum each patterns has shown in normal vescicular breathy from 100 Hz to 200 Hz, in crackle sound from 100 Hz to 400 Hz, in wheeze sound from 150 Hz to 600 Hz.

  • PDF

Measurement System of a Distance from Lightning Strokes to Observatory and Spectrum Analysis of Electric Fields Radiated from Lightning Discharges (뇌격거리측정계 및 뇌방전에 의해 발생하는 전장의 스펙트럼 분석)

  • Lee, B.H.;Chang, S.H.;Jeang, K.H.;Jeon, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1656-1658
    • /
    • 1998
  • This paper deals with a measurement system of a distance between lightning strokes and observatory station and spectrum analysis of electric fields radiated from lightning discharges. The distance measurement system, which consists of a loop type magnetic field sensor, a microphone and one chip microprocessor, is connected to a personal computer through RS232 port to acquire and process the data. This system is to use a difference of propagation velocity between an electromagnetic wave and a sonic wave produced by lightning discharge. Also, an electric field waveform and a frequency spectrum were investigated by an electric field measurement system with a hemisphere antenna and a spectrum analyzer with a biconical antenna and a log-periodic antenna, respectively. The results would be used as a basic reference to protect the power systems and electric circuits from lightning overvoltages.

  • PDF

Flourescence characteristics of the Alexandrite Laser (Alexandrite 레이저의 형광특성)

  • 윤태현
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.26-28
    • /
    • 1990
  • Cw arc 램프로 펌핑하는 Alexandrite 레이저의 형광을 optical Spectrum Analyzer를 이용하여 측정하였다. Vibronic 천이에 해당하는 광대역 형광 스펙트럼이 관측되었고, arc 램프 입력에 따른 peak 형광의 세기 및 peak intensity 파장의 입력 power 의존성을 조사하였다. 형광의 세기는 입력 power에 따라 0.16 /kw의 비율로 증가하였고, peak intensity 파장은 입력 power가 5kw 까지는 5 nm/kw 비율로 장파장쪽으로 이동하였다.

  • PDF

A Study on the Stationary Canceler in the Ultrasonic Pulse Doppler System (초음파 펄스 도플러 시스템의 Stationary Conceler에 대한 연구)

  • 김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.47-54
    • /
    • 1985
  • In this paper, clutter in ultrasound pulsed Doppler system is analyzed mathematically. And stationary canceler which reduce the clutter is designed. The operating characteristics of the stationary canceler is investigated in body (in vivo) by audio signal and spectrum analyzer.

  • PDF

Measurement of Electron Density and Electron-neutral Collision Frequency Using Cutoff Probe Based on the Plasma Reactance Measurement

  • Yu, Gwang-Ho;Kim, Dae-Ung;Na, Byeong-Geun;Seo, Byeong-Hun;Yu, Sin-Jae;Kim, Jeong-Hyeong;Seong, Dae-Jin;Sin, Yong-Hyeon;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.184-184
    • /
    • 2012
  • We proposed a new measurement method of cutoff probe using the reactance spectrum of the plasma in cutoff probe system instead of transmission spectrum. The high accurate reactance spectrum of the plasma which is expected in previous circuit simulation of cutoff probe [1] was measured by using the automatic port extension method of the network analyzer. The measured reactance spectrum is good agreement with E/M wave simulation result (CST Microwave Studio). From the analysis of the measured reactance spectrum based on the circuit modeling, not only the electron density but also electron-neutral collision frequency can be simply obtained. The obtained results of electron density and e-n collision frequency were presented and discussed in wide range of experimental conditions, together with comparison result with previous methods (a previous cutoff probe using transmission spectrum and a single langmuir probe).

  • PDF

Analysis of Voice Parameters on Different Phonatory Tasks using Multi-Channel Phonatory Function Analyzer in Healthy Adults (다채널 음성분석장치를 이용한 정상 성인에서의 발성 방식에 따른 음성변수 분석)

  • 성명훈;이상준;김광현;노종렬;권택균;이강진;박광석;최종민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Background and Objectives : The complex physiologic structure of the larynx can vibrate in three or more different ways that yield acuostically and perceptually distinct vocal quality. The purpose of this study is to examine the normal range of voice parameters in Multi-Channel Phonatory Function Analyzer and investigate the difference of voice parameters according to the phonatory patterns. Materials and Methods : Forty normal adult speakers (20 men and 20 women) with age ranging from third to forth decades pronounce low, comfortable, and high tone /a/ ; comfortable tone /${\ae}$/, /i/, /o/, and /u/ : fry, falsetto. Voice was analyzed by Newly developed multi-channel phonatory function analyzer. Results : The normal range of voice parameters in this system was similar to the existing data. Fry shows high jitter and falsetto low SQ. Fry and falsetto show low OQ in men but no difference in women. Jitter, OQ and SQ were different between men and women in modal register, whereas there was no gender difference in fry and falsetto. In frequency magnitude spectrum and EGG, modal register, fry and falsetto have distinguishing pattern. Conclusions : Modal register, fry and falsetto are distinguishable in voice parameters and show different vibratory patterns.

  • PDF

Establishment of the Electromagnetic Shielding Effectiveness Measurement System (전자파차폐효과 측정시스템의 구현)

  • 정연춘;강태원;정낙삼
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.3
    • /
    • pp.45-53
    • /
    • 1993
  • The shielding effectiveness of materials is determined by measuring the ratio of the incident electromagnetic power to that which passes through the material under test. The measurement system is constructed using several test fixtures, tracking generator, spectrum analyzer, step attenuator, RF switches, and amplifiers, etc.. The automation of measurements is completed using a personal computer. Especially, incident power, reflected power, and transmitted power are measured with only one spectrum analyzer using a dual directional coupler and RF switches. Therefore the system is to be used in design of shielding materials, as well as shielding effectiveness measurements. This system has dynamic range of more than 120 dB in the frequency range of 10 MHz to 1 GHz, and it can be used to measure shielding effectiveness of composite materials.

  • PDF

Performance Evaluation on the Reinforcing Material of Plastic Composites for the Electromagnetic Shielding (전자차폐(電磁遮蔽)를 위한 플라스틱 복합재료용(複合材料用) 강화재(强化材)의 성능평가(性能評價))

  • Kim, Dong-Jin;Murakami, Ri-ichi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.6 s.165
    • /
    • pp.1048-1054
    • /
    • 1999
  • It is important to study the shielding effectiveness(SE) of reinforcing material of plastic composite materials against the electromagnetic(EM) waves. In this paper, SE of the shielding material of EM waves was investigated with actual experiments. The materials used in this study were made up of film, fiber and powder of conductive materials - Cu, Al, CF etc. Also, The resin film was used as matrix. The experiment was carried out by using a shielding evaluator(Shielding box) TR17302 with an ADVANTEST spectrum analyzer, model R3361C. It was found from the experimental results that copper, aluminum and carbon fiber were good candidates as a shielding material against the EM waves with increasing the SE as the composite was laminated. The characteristics of the SE against the EM waves depended on a mode of preparation of specimen. The effects of interval of wires on the SE were studied when the orientation and the space of Cu wires were changed. The SE strongly depended on the. orientation and the space of the Cu wire. SE decreased as the space of the Cu wires was increasing.

A Study on the Electromagnetic Shielding of Conductive Powder (도전성(導電性) 분체(粉體)의 전자차폐(電磁遮蔽)에 관한 연구(硏究))

  • Kim, Dong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.244-249
    • /
    • 2004
  • In this paper, shielding effectiveness(SE) of the shielding paint of electromagnetic(EM) waves was investigated with actual experiments. The shielding paint used in this study were made of powder of conductive materials - Ag, Cu, Al, Sn, Ni. Cr, Graphite and Charcoal etc. with a solubility in oil and water. Also, the paper was used as a base sheet. The experiment was carried out by using a shielding evaluator(Shielding box) TR17302 with an ADVANTEST spectrum analyzer, model R3361C. It was found from the experimental results that silver, copper, nickel were good candidates as a shielding material against the EM waves with increasing the SE as the composite was laminated. The characteristics of the SE against the EM waves depended on a mode of preparation of specimen. The effects of density of particles on the SE were studied about the EM shielding paint. The SE strongly depended on the electric resistance by density of painting particles. SE increased as the density of particles was increasing.

  • PDF