• Title/Summary/Keyword: Spectrum Analyzer

Search Result 260, Processing Time 0.021 seconds

Study on the Non-isothermal Crystallization Behavior of Polypropylene/Corn Starch-MB Blends (폴리프로필렌/옥수수전분 블렌드의 비등온결정화 거동 연구)

  • Kim, Youn-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1125-1129
    • /
    • 2008
  • Polypropylene (PP)/corn starch master batch(starch-MB) blends with different PP compositions of 90, 80, 70, and 60 wt% were prepared by melt compounding at $200^{\circ}C$, using lab scale Brabender mixer. The chemical structures, thermal properties and non-isothermal crystallization behavior of the PP/starch-MB blends were investigated by FT-infrared spectrometry (FT-IR), differential scanning calorimetry (DSC), and thermogravimetric analyzer (TGA). The fabrication of the PP/starch-MB blend was confirmed by the existence of hydroxy group in FT-IR spectrum. There was no district change in melting temperature and melting enthalpy, and TGA curve indicates a decrease in degradation temperature with starch-MB content. The non-isothermal crystallization process was analyzed using by Avrami equation. The Avrami exponents were in the range of 2.71-3.97 for PP and 1.48-1.99 for PP/starch-MB blonds. The activation energies calculated by Kissinger method were 233 kJ/mol for PP, 484 kJ/mol for PP90, 541 kJ/mol for PP80, 553 kJ/mol for PP70, and 422 kJ/mol for PP60.

Development of Wireless Image Transmission System in Subway at 18GHz (18GHz 지하철 무선영상 전송시스템 개발)

  • Jeong, Sang-Guk;An, Tae-Ki;Kim, Back-Hyun;Nam, Myung-Woo;Lee, Young-Seock;Oh, Myung-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2196-2201
    • /
    • 2010
  • The video transmission system using OFDM method at 18GHz frequency band was developed for wireless video transmission from subway to monitoring center when subway running. It is composed of digital modulation board and RF board. And it has a robust characteristics of multipath fading in subway tunnels at 18GHz. To verify the system, we used spectrum analyzer for analysing the output of transmission system and get the results that it has 350MHz frequency, 8MHz bandwidth and -19dBm channel power. Also we tested video receiving using MPEG-2 encoder and got good quality images.

Simple Spectral Calibration Method and Its Application Using an Index Array for Swept Source Optical Coherence Tomography

  • Jung, Un-Sang;Cho, Nam-Hyun;Kim, Su-Hwan;Jeong, Hyo-Sang;Kim, Jee-Hyun;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.386-393
    • /
    • 2011
  • In this study, we report an effective k-domain linearization method with a pre-calibrated indexed look-up table. The method minimizes k-domain nonlinear characteristics of a swept source optical coherence tomography (SS-OCT) system by using two arrays, a sample position shift index and an intensity compensation array. Two arrays are generated from an interference pattern acquired by connecting a Fabry-Perot interferometer (FPI) and an optical spectrum analyzer (OSA) to the system. At real time imaging, the sample position is modified by location movement and intensity compensation with two arrays for linearity of wavenumber. As a result of evaluating point spread functions (PSFs), the signal to noise ratio (SNR) is increased by 9.7 dB. When applied to infrared (IR) sensing card imaging, the SNR is increased by 1.29 dB and the contrast noise ratio (CNR) value is increased by 1.44. The time required for the linearization and intensity compensation is 30 ms for a multi thread method using a central processing unit (CPU) compared to 0.8 ms for compute unified device architecture (CUDA) processing using a graphics processing unit (GPU). We verified that our linearization method is appropriate for applying real time imaging of SS-OCT.

Development of the pulse analyzing system using FBG (FBG를 이용한 맥진 시스템 개발)

  • Jeon, Young-Ju;Lee, Jeon;Ryu, Hyun-Hee;Lee, Jae-Hoon;Lee, Si-Woo;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • This work reports the pulse diagnosis system using FBG sensors which can display pulse signals detected while oriental medical doctors are conducting pulse diagnoses and simultaneously pressing the sensors by three fingers. Each optical fiber has five FBG sensing units fabricated in 2 mm width and 2 mm inter-sensor spacing. Three optical fibers with the FBG units in the parallel line configuration are then placed on each finger-pressing region and thus overall 9 fibers are used for the pulse measurements on the so-called "chon", "gwan", and "ch대k". A fixture holding the optical fiber arrays is able to adjust the height of the FBG sensing units while placing the fibers on the wrist. The pulse signals detected by the FBG sensors from chon, kwan, and chuk have been analyzed using 4 channel spectrum analyzer connected to the optical fibers. The measured pulse signals exhibit variations due to the nonuniform pressure distributions applied. resulting in the differences in the detected pulse signals between fiber lines. However. this work is the first step towards objective and quantitative analyses of the pulse diagnosis in oriental medicine which has traditionally been performed on subjective basis. Future works will be devoted to improving sensor stability, developing the way applying pressure and algorithms reporting the objective classification of the pulse status from systemic measurements using the sensors instead of relying on the clinicians' diagnoses subjectively performed. A successful pulse diagnosis system emerging in the future is expected to contribute to education as well as promoting pulse diagnosis in oriental medicine to the scientific research area.

  • PDF

THE INHIBITORY EFFECT OF STREPTOCOCCAL CELL WALL EXTRACTS ON STIMULATION OF LYMPHOCYTES (연쇄구균의 세포벽 단백질 추출물이 림프구 활성의 억제에 미치는 영향)

  • Sang, Hyoung-Sook;Jeong, Hee-Il;Oh, Se-Hong;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.275-288
    • /
    • 1995
  • The inhibitory effect of cell wall extracts of streptococci, have been investigated to know host-parasite relationship or pathogenesis of abscess formation. Streptococci isolated from the infected root canals were sonicated to get cell wall extracts which have been known as one of the factors of pyogenesis. Lymphocytes separated by density gradient were stimulated with phytohemagglutinin and exposed to cell wall extracts of Streptococcus sanguis, S. mitis, S. uberis, S. mutans (ATCC 10449), and S. faecalis (ATCC 19433). [$^3H$]-thymidine uptake of lymphocytes was analyzed with scintillation counter and lactate dehyrogenase (LD) activity was measured with autochemistry analyzer. S. faeealis had the strongest inhibitory effect. beginning at $100\;{\mu}g/ml$ concentration of sonic extracts. S. sanguis and S. mitis had inhibitory effect at $300\;{\mu}g/ml$, while S. uberis and S. mutans showed no inhibitory, effect on DNA syntheis even at $300\;{\mu}g/ml$. Each streptococci showed different inhibitory effect on the DNA synthesis of lymphocytes, which finding indicated wide spectrum of susceptibility of lymphocytes according to streptococcus spp. There were no significant difference of LD activities between control and each streptococcal extracts. Streptococcal sonic extracts did not affect the morphological findings or number of colonies activated lymphocytes. These finding suggested the inhibitory effect of sonic extract of streptococci to lymphocytes could be detected by DNA synthesis inhibition, not by cellular membrane damage.

  • PDF

A Differences in Preference and Evaluation on the Image of Make-up (Part I) -Focused on Perceiver's Genders- (화장색 이미지평가와 선호도 차이 (제1보) -지각자의 성별을 중심으로-)

  • Lee Yon-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.4 s.152
    • /
    • pp.567-581
    • /
    • 2006
  • The purpose of this research is to provide the basic data for the development of make-up color application system, based of Korean's skin tone and the preference in make-up color to enhance the effectiveness of the education of beauty in universities. The research was conducted by the previous studies, the analyses of sale's rate of hue-cosmetics, the analytic experiment of color of cosmetics by using Spectrum Color Analyzer and other experimental researches. This research, based on the results of three preliminary researches, shows the result of evaluation from perceivers which has been come out from the experiment of having one model in her twenties being changed with twenty-two different conditions of make-up. Here follows the result of the research. Firstly, there was difference on perceiving images in terms of the gender of perceivers and especially male-group tend to have clearly perceived the gap between elegance-greyish purple, orange-natural, red-classic on monochrome make-up and contrast make-up. Secondly, in terms of lip-colors, salmon pink and pink was regarded positively to both female and male subjects and to male subjects, greyish purple was thought to be better on darker skin-tone and to female subjects, better on lighter skin-tone. Thirdly, on image make-up, romantic gives intelligent image regardless of skin-tone and gender, especially gives more positive looks to male subjects. Natural and classic elements were perceived more positively on darker skin-tone and had bigger perceiving gap in female subjects. Fourthly, in preference rate, male subjects normally preferred the look with make-up than female subjects did and salmon pink and pink lip color was preferred on the darker skin-tone.

Implementation of a Fluxgate Sensor using Ferrite Ring Core (페라이트 링 코어를 사용한 fluxgate 센서의 구현)

  • Park, Yong-Woo;Kim, Ki-Uk;Kim, Nam-Ho;Ryu, Ji-Goo
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.427-433
    • /
    • 1999
  • In this paper, we have presented an one-axis fluxgate magnetic sensor with ferrite core, excitation, and pick-up coil. This magnetometer is consist of a sensing element, driving circuits for excitation coil and signal processing for detecting second harmonic frequency component which is proportional to the DC magnetic to be measured. The sensor core is excited by a square waveform of voltage through 82 turns of the excitation coil. The second harmonic output of pick-up coil(150 turns) is measured by a FFT spectrum analyzer. This result is compared to output of PSD(phase sensitive detector) unit for detecting a second harmonic component. The measured sensitivity is about 50 V/T at driving frequency of 2 kHz. The nonlinearity of fluxgate magnetic sensor is calculated about 2.0%.

  • PDF

Fabrication and Characterization of a Fiber-Optic Alpha/Beta Detector for Nuclear Medicine Application (핵의학 적용을 위한 광섬유 기반의 알파/베타 검출기의 제작 및 특성분석)

  • Hong, Seung-Han;Yoo, Wook-Jae;Shin, Sang-Hun;Seo, Jeong-Ki;Han, Ki-Tek;Jeon, Da-Yeong;Cho, Seung-Hyun;Lee, Bong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.367-373
    • /
    • 2012
  • We fabricated a fiber-optic alpha/beta detector, which is composed of a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer, to obtain the energy spectra of radioactive isotopes. As inorganic scintillators of a sensing probe, a ZnS(Ag) film was coupled with a $CaF_2$(Eu) crystal for alpha and beta spectroscopy. In this study, $^{210}Po$ and $^{90}Sr$ were used as alpha and beta sources, respectively, and we measured the radiation energy spectra using a fiber-optic alpha/beta detector to identify alpha and beta emitting radionuclides for nuclear medicine application. Also, the variations of energy spectrum were obtained according to the length of plastic optical fiber.

Assessment of Relapsing Urolithiasis from K43 with Erosive Gastritis (미란성 위염 환자 K43에서 재발성 요로 결석에 관한 연구)

  • 김재웅
    • The Korean Journal of Food And Nutrition
    • /
    • v.10 no.1
    • /
    • pp.44-52
    • /
    • 1997
  • Nephrolithiasis is the most common disorder of the urinary tract in hospitalized patients, more frequently increased in 30~50 years of age, more common in males than in females, prior right stone to left side, and than upper ureteral stone is found in cultural country, while lower ureteral stone is increased in uncultural country. Stone components are classified as calcium oxalate, calcium phosphate, magnesium ammonium phosphate, uric acid, cystine, and their mixed stone, respectively. According to the pathophysiology of urinary stones, supersaturation/crystalization of inorganic salt concentration in urine, organic matrix, inhibitor deficiency, and epitaxy theory could be based on the stone formation. Not only hypercalciuria, hyperparathyroidism, hyperoxaluria, hyperuricosuria, and cystinuria, but also renal tubular acidosis, hypervitaminosis D, and peptic ulcer, are significantly associated with nephrolithiasis. In this study upper ureteral stone component were analyzed with chemical analysis, infrared spectrum, and image analyzer from K43 patient wit erosive gastritis. As the results, mixed stone of calcium oxalate dihydrate and calcium phosphate apatite was identified, the values of clinical test in blood and urine maintained normal revels. The relapsing urinary stone from K43 have no correlation between factors for stone formation reported early, also have no evidence for risk from erosive gastritis.

  • PDF

A Design on High Frequency CMOS VCO for UWB Applications (UWB 응용을 위한 고주파 CMOS VCO 설계 및 제작)

  • Park, Bong-Hyuk;Lee, Seung-Sik;Choi, Sang-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.213-218
    • /
    • 2007
  • In this paper, we propose the design and fabrication on high frequency CMOS VCO for DS-UWB(Direct-Sequence Ultra-WideBand) applications using 0.18 ${\mu}m$ process. The complementary cross-coupled LC oscillator architecture which is composed of PMOS, NMOS symmetrically, is designed for improving the phase noise characteristic. The resistor is used instead of current source that reduce the 1/f noise of current source. The high-speed buffer is needed for measuring the output characteristic of VCO using spectrum analyzer, therefore the high-speed inverter buffer is designed with VCO. A fabricated core VCO size is $340{\mu}m{\times}535{\mu}m$. The VCO is tunable between 7.09 and 7.52 GHz and has a phase noise lower than -107 dBc/Hz at 1-MHz offset over entire tuning range. The measured harmonic suppression is 32 dB. The VCO core circuit draws 2.0 mA from a 1.8 V supply.