• 제목/요약/키워드: Spectroscopy

검색결과 10,571건 처리시간 0.046초

수종 광중합 복합 레진의 중합 깊이와 광조사 시간에 따른 중합률에 관한 연구 (A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE DEPTH OF CURE AND LIGHT CURING TIME)

  • 김경현;권오승;김현기;백규철;엄정문;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.35-60
    • /
    • 1997
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc, depend on the degree of conversion of the resin components. The clinical behavior of restorative resins varies brand to brand. Part of this variation is associated with the filler and differences in the polymer matrix. The polymer matrix of resins may differ because the involved monomers are dissimilar and because of variation in the catalyst system. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the depth of cure and light curing time. 7mm diameter cylindrical aluminum molds were filled with each of five different hybrid light curing composite resins(Z-100, Charisma, Herculite XRV, Prisma TPH, Veridonfil) on the thin resin films. The molds were 1mm, 2mm, 3mm, 4mm, and 5mm in depth to produce resin films of various heights. Each sample was given 20sec, 40sec, and 60sec illumination with a light source. The degree of conversion of carbon double bonds to single bonds in the resin films was examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows; 1. There was difference in the degree of conversion among five light curing composite resins according to the depth of cure for 20sec, 40sec, and 60sec illumination with light source with statistical significance(P<0.05). 2. Five light curing composite resins show lower degree of conversion at surface of the resin than depth of 1mm. 3. The degree of conversion of five light curing composite resins was siginificantly reduced from the maximum for the resin film when the light passed through as little as 1mm of each composite. 4. The degree of conversion of five light curing composite resins decrease significantly at the depth of 4mm, and polymerization was not occured at the depth of 5mm except for Prisma TPH. 5. The degree of conversion of five light curing composite resins was increased with increased light curing time, and there was no significant differences in the degree of conversion above 4mm in Z-100, 3mm in Charisma, and at depth of 5mm in Herculite XRV and Veridonfil(P>0.05).

  • PDF

근적외분광분석기를 이용한 검정콩 안토시아닌의 함량 분석 (Development of Prediction Model by NIRS for Anthocyanin Contents in Black Colored Soybean)

  • 김용호;안형균;이은섭;김희동
    • 한국작물학회지
    • /
    • 제53권1호
    • /
    • pp.15-20
    • /
    • 2008
  • 검정콩 종피에 함유된 안토시아닌의 색소별 함량을 비파괴적으로 신속하게 분석하기 위하여 NIRS(근적외선 분광분석기)를 이용한 모델을 개발하였다. 재료는 검정콩 유전자원 300 계통을 사용하였으며, HPLC에서 분석된 종피의 안토시아닌 함량치를 NIRS 스펙트럼에 적용시킨 후 검량식을 작성하였다. NIRS의 검량식을 몇 가지 방법에 의하여 비교 분석한 결과 1차미분된 스펙트럼을 MPLS(Modified Partial Least Squares)를 이용한 회귀식에 이용하는 것이 가장 적합하였다. HPLC를 이용한 유전자원들의 성분 함량과 NIRS에서 도출된 검량식과의 상관계수는 C3G, D3G 및 Pt3G가 각각 0.952, 0.936과 0.833을 나타내었다. 이들 검량식은 validation file에서도 C3G와 D3G는 0.897, 0.849의 높은 상관을 보였으며, 이는 NIRS를 이용하여 검정콩의 안토시아닌 함량을 신속하게 분석할 수 있음을 나타내는 것으로 판단되었다.

청정분산제의 적외선 분광스펙트럼 비교를 통한 자동차용 휘발유 제조사의 판별 (Determination of Gasoline Brands by the Comparison of Infrared Spectra of Polymeric Dispersants)

  • 김명희;장영식;정충섭;이현기
    • 분석과학
    • /
    • 제11권6호
    • /
    • pp.469-473
    • /
    • 1998
  • 자동차용 휘발유 제조사의 확인 또는 판별은 석유류의 정상적인 유통관리 및 오염사고시 오염원의 추적을 위해 필요하다. 일반적으로 휘발유의 화학적 조성은 가스크로마토그래피(GC)로 분석이 가능하며, 제품별로 얻어진 크로마토그램의 차이로부터 각 제품을 구분할 수 있으나 제조기준의 세분화로 휘발유의 조성이 유사해져 GC분석에 의한 판별이 더욱 어렵게 되었다. 본 연구에서는 보다 신속하고 정확하게 휘발유 제품을 판별하기 위하여, 분산제의 적외선 분광스펙트라를 비교하여 제조사(A, B, C, D, E사로 구분)를 구분하는 방법을 도식화하였다. IR spectra는 휘발유를 검시험기(gum tester)로 증발시키고, 잔여물을 n-pentane으로 녹여 ATR(Attenuated Total Reflectance) cell로 옮기고 다시 용매를 증발시킨 후에 얻었다. 'A', 'B', 및 'C'정유사에서 사용하는 첨가제들은 에테르(ether)의 C-O 신축진동에 의한 넓고 강한 피크가 $1,096cm^{-1}$에서 나타나 'D'와 'E'정유사의 첨가제들과 뚜렷하게 구별이 가능하였고, 또 다른 특징적인 피크들로써 각 정유사 제품의 구분이 모두 가능하였다.

  • PDF

디오스민 캡슐의 HPLC 분석법의 개발 (Development of high performance liquid chromatography assay method of diosmin capsules)

  • 심대현;신동한;쯔엉쿡끼;마이수안란;강종성;우미희;나동희;전인구;김경호
    • 분석과학
    • /
    • 제29권6호
    • /
    • pp.277-282
    • /
    • 2016
  • 영국약전(BP 2013), 미국약전(USP 39) 그리고 대한민국약전 (KP XI)에 디오스민 원료의 정량법으로 HPLC법이 수재되어 있다. 그러나 위의 외국약전들에는 디오스민 제제의 정량법이 수재되어 있지 않으며 대한민국약전 (KP XI)에는 디오스민 캡슐의 정량법으로 HPLC법보다 덜 특이적인 자외가시부흡 광도측정법이 수재되어 있다. 이 실험에서는 최근의 추세에 따라 원료의 정량법과 같고 특이성이 좋은 HPLC 분석법으로 디오스민 캡슐의 정량법을 개발하였고 이를 검증하였다. HPLC분석법의 검증을 위해 직선성, 정밀성, 정확성, 시스템 적합성, 실험실내 정밀성과 완건성 실험을 실행하였다. 직선성은 결정계수($r^2$)가 0.999 이상으로 우수하였다. 일내 정밀도는 상대표준편차 0.15~0.29%, 일간 정밀도는 1.05~1.74%로, 회수율은 101.2~103.2%로 나타났다. 시스템적합성에서는 머무름시간 상대표준편차(RSD %) 0.37 %, 피크면적 상대표준편차(RSD%) 0.06%, 이론단수 평균값 3591.293 그리고 비대칭계수 평균값 1.35을 나타내었다. 개발한 시험법을 이용하여 시중 유통 중인 디오스민 캡슐 중 디오스민의 함량측정에 응용하였다. 개발된 시험법은 대한민국약전의 개정에 기여할 것이다.

Performance Evaluation of Hazardous Substances using Measurement Vehicle of Field Mode through Emergency Response of Chemical Incidents

  • Lee, Yeon-Hee;Hwang, Seung-Ryul;Kim, Jae-Young;Kim, Kyun;Kwak, Ji Hyun;Kim, Min Sun;Park, Joong Don;Jeon, Junho;Kim, Ki Joon;Lee, Jin Hwan
    • 한국환경농학회지
    • /
    • 제34권4호
    • /
    • pp.294-302
    • /
    • 2015
  • BACKGROUND: Chemical accidents have increased owing to chemical usage, human error and technical failures during the last decades. Many countries have organized supervisory authorities in charge of enforcing related rules and regulations to prevent chemical accidents. A very important part in chemical accidents has been coping with comprehensive first aid tool. Therefore, the present research has provided information with the initial applications concern to the rapid analysis of hazardous material using instruments in vehicle of field mode after chemical accidents. METHODS AND RESULTS: Mobile measurement vehicle was manufactured to obtain information regarding field assessments of chemical accidents. This vehicle was equipped with four instruments including gas chromatography with mass spectrometry (GC/MS), Fourier Transform Infrared Spectroscopy (FT-IR), Ion Chromatography (IC), and UV/Vis spectrometer (UV) to analyses of accident preparedness substances, volatile compounds, and organic gases. Moreover, this work was the first examined the evaluation of applicability for analysis instruments using 20 chemicals in various accident preparedness substances (GC/MS; 6 chemicals, FT-IR; 2 chemicals, IC; 11 chemicals, and UV; 1 chemical) and their calibration curves were obtained with high linearity ( r 2 > 0.991). Our results were observed the advantage of the high chromatographic peak capacity, fast analysis, and good sensitivity as well as resolution. CONCLUSION: When chemical accidents are occurred, the posted measurement vehicle may be utilized as tool an effective for qualitative and quantitative information in the scene of an accident owing to the rapid analysis of hazardous material.

신기술 이용 식중독균 신속검출법 개발 동향 분석 (Trends in Rapid Detection Methods for Food-borne pathogenic Microorganisms by Using New Technologies)

  • 김현주;김용수;정명섭;오덕환;전향숙;하상도
    • 한국식품위생안전성학회지
    • /
    • 제25권4호
    • /
    • pp.376-387
    • /
    • 2010
  • 식품으로부터 식중독세균을 검출하는 대부분의 전통적인 방법들은 분리하고자 하는 미생물에 적합한 선택배지에 의존할 수밖에 없다. 이러한 선택배지들은 높은 경제성에도 불구하고 오래 걸려 때를 놓치게 되는 소요 시간이 항상 걸림돌로 작용하고 있으며, 하나의 선택배지로 한의 균만을 선택적으로 분리해 내는 등의 단점이 있다. 이러한 단점을 최소화하기 위하여 IMS 등 면역학적 또는 분자생물학적 기법들을 접목시키고 있고, 증균에서 분리와 확인을 동시에 할 수 있는 package 형태의 제품들이 시판되고 있다. 또한 이러한 제품 중 일부는 국제표준기구로부터 인증을 받았고 대부분 chromogenic 기질을 함유한 선택배지들이 포함되어 있을 만큼 신뢰도가 높다고 할 수 있다. 그러나 선택배지 자체만은 이들 단점을 해결할 수 없어 항체를 활용한 신속, 간편하고 환경친화적인 ELISA법, 검출장비가 불필요하여 가장 신속, 간편하게 현장에서 사용하도록 기술을 향상시킨 paper-strip kit나 ELISA 분석 시 직면하는 시료의 matrix effect를 최소화할 수 있다는 장점을 지닌 형광면역분석법(fluoroimmunoassay)등 새로운 기술이 용도에 맞게 다양하게 개발되고 있다. 또한 동시진단 능력이 우수한 현장 진단형 시스템이 개발될 경우, 향후 신 시장 창출, 바이오칩 기술발전, 식중독균을 포함한 위해 미생물의 동시진단 및 역학조사 등에 지대한 기여를 할 것으로 판단된다. 식품에서 식품위해미생물 검출에 있어서 가장 이상적인 방법은 검출 과정이 간단하고 경제적이며 정확하여야 한다는 것이다. 또한 정량적 결과 산출이 가능하여야 하고, 자동화된 방법으로 전환이 가능하여야 산업에 적용될 수 있다는 것인데, 이러한 이상적인 검출방법은 현재까지 존재하지 않는다. 다만, 여러 방법들이 각각의 장점을 갖고 있을 뿐이다. 즉, 현실적 대안은 현재까지 개발된 각각의 방법을 목적과 대상에 따라 시의적절하게 병용 사용하여야 한다는 것이다.

Centrifugal Partition Chromatography에 의한 황백으로부터 Berberine의 분리 및 정제 (Isolation and Purification of Berberine in Cortex Phellodendri by Centrifugal Partition Chromatography)

  • 김중배;방병호
    • 한국식품영양학회지
    • /
    • 제27권3호
    • /
    • pp.532-537
    • /
    • 2014
  • 황백(Cortex Phellodendri: CP)은 황벽나무(Phellodendron amurense)의 건조된 수피로부터 얻어진다. 이 수피는 한국의 전통 한약제로서 설사, 황달, 무릎과 발의 통증, 요도관 및 피부 감염증에 폭넓게 사용되어 왔다. 이들 기능성 성분의 분리 및 정제는 박층 크로마토크래피, 컬럼 액체 크로마토크래피 및 HPLC와 같은 여러 분석법들이 동양의 약초연구에 이용되어 왔다. 본 연구는 CP로부터 berberine을 분리하기 위해 향류분배 크로마토크래피법(CPC)으로 효과적으로 수행하였다. 두 용매의 CPC 최적조성은 n-butanol: acetic acid: water(4:1:5 v/v/v)이었다. 이동상의 유속은 1,000 rpm 회전력에서 상승법으로 분당 3 mL 속도로 전개시켰다. CPC에서 분리된 분획분은 prep-HPLC로 정제하였다. $^1H$-NMR 스펙트럼은 4.10과 4.20 ppm에서 $3H(-OCH_3)$, 6.10 ppm에서 2H의 ($-OCH_2O-$) proton signal의 공명이 관찰되었다. 2개의 방향족 proton은 이중결합 패턴을 보였다. H-11과 H-12 doublet은 각각 7.98과 8.11에서 나타났다. $^{13}C$-NMR 스펙트럼에서는 C2와 C3의 methylenedioxy group($-OCH_2O-$), C9과 C10에 methoxy group($-OCH_3$)이 4개의 치환된 형태로 보였다. 분리 정제된 berberine의 화학구조는 $^1H$, $^{13}C$-NMR, ESI-MS 데이터 분석으로 확인하였다.

니켈 코팅된 탄소나노튜브/산화아연 나노복합소재의 제조와 항균 및 기계적 특성 분석 (Preparation of Nickel Coated-carbon Nanotube/Zinc Oxide Nanocomposites and Their Antimicrobial and Mechanical Properties)

  • 김현혜;한웅;안계혁;김병주
    • 공업화학
    • /
    • 제27권5호
    • /
    • pp.502-507
    • /
    • 2016
  • 본 연구에서는 탄소나노튜브, 니켈 및 산화아연의 항균특성 활용을 목적으로 새로운 항균 나노 복합 재료를 개발하였다. 니켈 코팅된 탄소나노튜브의 제조 및 그들의 동시발생 집중 및 비활성 세균에 대한 항균소재의 잠재적 응용성을 평가하였다. 제조된 니켈 도금 탄소나노튜브의 형상 및 니켈 도금은 전계 방출 주사전자현미경(FE-SEM) 및 X선 에너지 분산 분광기(EDS)를 사용하여 분석하였다. 나노복합소재의 항균 특성을 확인할 수 있는 타깃 세균은 황색포도상구균과 대장균으로 지정하였다. 니켈 도금된 탄소나노튜브와 산 처리된 탄소나노튜브로 각각 강화된 나노복합소재의 황색포도상구균 및 대장균에 대한 항균특성을 비교하였을 때, 니켈 도금된 탄소나노튜브/산화아연으로 강화된 나노복합소재의 항균 특성이 더 우수한 결과를 보이는 것을 확인할 수 있었다. 이러한 결과에 따라서, 탄소나노튜브 표면에 도금된 니켈이 복합소재 내에서 세균의 살균 작용에 중요한 역할을 하는 것으로 판단할 수 있다. 또한, 첨가된 산화아연은 나노복합소재의 항균특성 향상을 목적으로 제안되었다.

열분해잔사유로부터 불균일계 불소화공정에 의해 제조된 메조페이스 피치의 특성 (The Characteristics of Mesophase Pitch Prepared by Heterogeneous Fluorination Process from Pyrolysis Fuel Oil)

  • 김도영;김지현;이형익;이영석
    • 공업화학
    • /
    • 제27권5호
    • /
    • pp.537-542
    • /
    • 2016
  • 본 연구에서는 불균일계 불소화 개질 공정을 이용하여 열분해잔사유(PFO)로부터 메조페이스 피치를 제조하였다. 이 공정은 다양한 온도의 직접 불소화 공정과 $390^{\circ}C$의 열처리 공정을 통하여 진행하였다. 제조된 피치는 연화점, 원소분석, 푸리에 변환 적외선 분광 분석, 고분해능 X-ray 회절 분석 그리고 편광 현미경 분석을 실시하였다. 제조된 피치의 탄소 함량은 직접 불소화 공정의 반응 온도 증가에 따라 함께 상승하였으며, 그 산소, 질소 그리고 황 성분은 완전하게 제거되었다. 불소화 온도가 증가함에 따라서, 메조페이스 소구체의 생성, 성장, 합체, 정렬이 관찰되었다. 탄소 육각망면의 층간간격이 감소하였고 결정자 크기가 증가하였다. 또한, 지방족 화합물의 축 중합으로 인한 방향족 화합물의 함량 증가가 관찰되었다. 이러한 결과는 반응 온도의 증가에 따라 증가된 불소 라디칼의 반응성에 기인한다. 불소화 반응은 열분해잔사유가 라디칼 반응에 의한 중합반응의 촉진으로, 방향족 화합물의 생성을 돕는 것으로 판단된다.

(C10H8N2H)2Cr2O7를 이용한 치환 벤질 알코올류의 산화반응과 반응속도에 관한 연구 (A Study for Kinetics and Oxidation Reaction of Substituted Benzyl Alcohols Using (C10H8N2H)2Cr2O7)

  • 박영조;김영식;김수종
    • 공업화학
    • /
    • 제28권5호
    • /
    • pp.597-600
    • /
    • 2017
  • 4,4'-비피리딘과 크롬(VI) 산화물을 반응시켜 $(C_{10}H_8N_2H)_2Cr_2O_7$을 합성하였다. 적외선분광광도법(FT-IR)과 원소분석으로 구조를 확인하였다. 여러 가지 용매 하에서 $(C_{10}H_8N_2H)_2Cr_2O_7$을 이용하여 벤질알코올의 산화반응을 측정한 결과, 용매의 유전상수 값이 증가함에 따라 반응수율이 증가했다. 그 순서는 DMF (N,N'-디메틸포름아미드) > 아세톤 > 클로로포름 > 시클로헥센이었다. $H_2SO_4$ 촉매를 이용한 DMF 용매 하에서, $(C_{10}-H_8N_2H)_2Cr_2O_7$은 벤질알코올(H)과 그의 유도체들($p-OCH_3$, $m-CH_3$, $m-OCH_3$, m-Cl, $m-NO_2$)을 효과적으로 산화시켰다. 전자받개 그룹들은 반응속도가 감소한 반면에 전자주개 치환체들은 반응속도를 증가시켰고, Hammett 반응상수(${\rho}$) 값은 -0.70 (308 K)이었다. 본 실험에서 알코올의 산화반응 과정은 속도결정단계에서 수소화 전이가 일어났다.