• Title/Summary/Keyword: Spectral volume method

Search Result 33, Processing Time 0.027 seconds

Numerical Simulation on Laminar Flow past a Rotating Circular Cylinder (회전하는 원형 실린더 주위 층류유동장의 수치 시뮬레이션)

  • Park, Jong-Chun;Moon, Jin-Kook;Yoon, Hyun-Sik;Lee, Byung-Hyuk;Chun, Ho-Hwan;Suh, Sung-Bu
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.1-10
    • /
    • 2005
  • The effect of rotation on the unsteady laminar flaw past a circular cylinder is numerically investigated in the present study. The numerical solutions for the 2D Navier-Stokes equation obtained, using two different numerical methods. One is an accurate spectral method and the other is a finite volume method(FVM). First, the flaw around a stationary circular cylinder is investigated to understand the basic phenomenon of flaw separation and bluff body wake. Next, the flow characteristics of the laminar flow, past a rotating circular cylinder, are investigated, using a FVM developed in this study. By the effect of rotation, it is seen that values of lift increase, while the values of mean drag decrease. Further, the criteria of angular velocity, at which the Karman vorteces disappear, is also determined.

Spatial Distribution Mapping of Cyanobacteria in Daecheong Reservoir Using the Satellite Imagery (위성영상을 이용한 대청호 남조류의 공간 분포 맵핑)

  • Back, Shin Cheol;Park, Jin Ki;Park, Jong Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.2
    • /
    • pp.53-63
    • /
    • 2016
  • Monitoring of cyanobacteria bloom in reservoir systems is important for water managers responsible of water supply system. Cyanobacteria affect the taste and smell of water and pose considerable filtration problems at water use places. Harmful cyanobacteria bloom in reservoir have significant economic impacts. We develop a new method for estimating the cyanobacteria bloom using Landsat TM and ETM+ data. Developed model was calibrated and cross-validated with existing in situ measurements from Daecheong Reservoir's Water Quality Monitoring Program and Algae Alarm System. Measurements data of three stations taken from 2004 to 2012 were matched with radiometrically converted reflectance data from the Landsat TM and ETM+ sensor. Stepwise multiple linear regression was used to select wavelengths in the Landsat TM and ETM+ bands 1, 2 and 4 that were most significant for predicting cyanobacteria cell number and bio-volume. Based on statistical analysis, the linear models were that included visible band ratios slightly outperformed single band models. The final monitoring models captured the extents of cyanobacteria blooms throughout the 2004-2012 study period. The results serve as an added broad area monitoring tool for water resource managers and present new insight into the initiation and propagation of cyanobacteria blooms in Daecheong reservoir.

Simulation of 27Al MQMAS NMR Spectra of Mordenites Using Point Charge Model with First Layer Only and Multiple Layers of Atoms

  • Chae, Seen-Ae;Han, Oc-Hee;Lee, Sang-Yeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.11
    • /
    • pp.2069-2074
    • /
    • 2007
  • The 27Al multiple quantum magic angle spinning (MQMAS) nuclear magnetic resonance (NMR) spectra of mordenite zeolites were simulated using the point charge model (PCM). The spectra simulated by the PCM considering nearest neighbor atoms only (PCM-n) or including atoms up to the 3rd layer (PCM-m) were not different from those generated by the Hartree-Fock (HF) molecular orbital calculation method. In contrast to the HF and density functional theory methods, the PCM method is simple and convenient to use and does not require sophisticated and expensive computer programs along with specialists to run them. Thus, our results indicate that the spectral simulation of the 27Al MQMAS NMR spectra obtained with the PCM-n is useful, despite its simplicity, especially for porous samples like zeolites with large unit cells and a high volume density of pores. However, it should be pointed out that this conclusion might apply only for the atomic sites with small quadrupole coupling constants.

Design and Implementation of a Prediction System for Cardiovascular Diseases using PPG (PPG를 이용한 심혈관 질환 예측 시스템의 설계 및 구현)

  • Song, Je-Min;Jin, Gye-Hwan;Seo, Sung-Bo;Park, Jeong-Seok;Lee, Sang-Bock;Ryu, Keun-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.19-25
    • /
    • 2011
  • Photoplethysmogram(PPG) is the method to obtain the biomedical signal using the linear relationships between the blood volume for changing the cardiac contraction and relaxation and the amount of light for absorbing the hemoglobin in the blood. In this paper, we proposed the analyzed results which show the heart rate variability and the distribution of heart rate for before and after using PPG. Moreover, this paper designed and implemented the system based on personal computer to predict cardiovascular disease in advance using the analyzed results for the autonomic balance from taking the spectral analysis of heart rate and the state of the blood vessel for analyzing APG(acceleration plethysmogram).

Prediction of Precipitated Wax Amounts Using FTIR Spectroscopy (FTIR을 이용한 왁스 침전의 정량적 예측)

  • Oh, Kyeongseok
    • Korean Chemical Engineering Research
    • /
    • v.51 no.3
    • /
    • pp.376-381
    • /
    • 2013
  • High molecular weight paraffinic waxes dissolved in oil phases can be precipitated when the surrounding temperature becomes lower than the wax appearance temperature (WAT). While the various methods of WAT determination have been developed, the determination of precipitated wax amount has not been comparably popular at temperatures below the WAT. It is important to predict how much solid wax content precipitates in temperature variance. The study develops the previous method which uses integrated areas determined at a wavenumber range of 735~715 $cm^{-1}$. This method uses two different wavenumber ranges, 735~715 $cm^{-1}$ and 1,402~1,324 $cm^{-1}$. The study shows how the method provides reliable data in the variety of applications regardless of FTIR spectral instability often occurred, such as volume reduction during cooling procedure and existence of emulsified water in oil phase.

Development of a Storage Level and Capacity Monitoring and Forecasting Techniques in Yongdam Dam Basin Using High Resolution Satellite Image (고해상도 위성자료를 이용한 용담댐 유역 저수위/저수량 모니터링 및 예측 기술 개발)

  • Yoon, Sunkwon;Lee, Seongkyu;Park, Kyungwon;Jang, Sangmin;Rhee, Jinyung
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.1041-1053
    • /
    • 2018
  • In this study, a real-time storage level and capacity monitoring and forecasting system for Yongdam Dam watershed was developed using high resolution satellite image. The drought indices such as Standardized Precipitation Index (SPI) from satellite data were used for storage level monitoring in case of drought. Moreover, to predict storage volume we used a statistical method based on Principle Component Analysis (PCA) of Singular Spectrum Analysis (SSA). According to this study, correlation coefficient between storage level and SPI (3) was highly calculated with CC=0.78, and the monitoring and predictability of storage level was diagnosed using the drought index calculated from satellite data. As a result of analysis of principal component analysis by SSA, correlation between SPI (3) and each Reconstructed Components (RCs) data were highly correlated with CC=0.87 to 0.99. And also, the correlations of RC data with Normalized Water Surface Level (N-W.S.L.) were confirmed that has highly correlated with CC=0.83 to 0.97. In terms of high resolution satellite image we developed a water detection algorithm by applying an exponential method to monitor the change of storage level by using Multi-Spectral Instrument (MSI) sensor of Sentinel-2 satellite. The materials of satellite image for water surface area detection in Yongdam dam watershed was considered from 2016 to 2018, respectively. Based on this, we proposed the possibility of real-time drought monitoring system using high resolution water surface area detection by Sentinel-2 satellite image. The results of this study can be applied to estimate of the reservoir volume calculated from various satellite observations, which can be used for monitoring and estimating hydrological droughts in an unmeasured area.

Effects of Flight Conditions on IR Signature from Aircraft Exhaust Plume (비행조건에 따른 항공기 배기플룸의 IR 신호 특성)

  • Go, Gun-Yung;Kim, Man-Young;Baek, Seung-Wook
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.5
    • /
    • pp.58-66
    • /
    • 2012
  • The IR signature and radiative base heating from an aircraft plume have been important factors for aircraft survivability in modern battle fields. In order to enhance the aircraft survivability and reduce the base heating, infrared signatures emitted from an aircraft exhaust plume should be determined. In this work, therefore, IR signatures and radiative base heating characteristics are examined in the plume exhausted from the aircraft with operating at altitude of 5 km in M=0.9 and 1.6, respectively. As a result, it is found that the particular wavelength IR signature has high spectral characteristics because of $H_2O$ and $CO_2$ gases in the plume, and the radiative heat flux coming into the base plane increases with higher Mach number and shorter distance.

Effects of Flight Conditions on IR Signature from Aircraft Exhaust Plume (비행조건에 따른 항공기 배기플룸의 IR 신호 특성)

  • Go, Gun-Yung;Kim, Man-Young;Baek, Seung-Wook
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.282-289
    • /
    • 2012
  • The IR Signature and radiative base heating from an aircraft plume have been important factors for aircraft survivability in modern battle fields. In order to enhance the aircraft survivability and reduce the base heating, infrared signatures emitted from an aircraft exhaust plume should be determined. In this work, therefore, IR signatures and radiative base heating characteristics are examined in the plume exhausted from the aircraft with operating at altitude of 5km in M=0.9 and 1.6, respectively. As a result, it is found that the particular wavelength IR signature has high spectral characteristics because of $H_2O$ and $CO_2$ gases in the plume, and the radiative heat flux coming into the base plane increases with higher Mach number and shorter distance.

  • PDF

The Solvent Effect on the Chemical Changes in Binary Mixture : i.e. THF-H2O System (Ⅰ) (이성분 혼합용매에서 화학변화에 미치는 용매의 영향 : THF-$H_2O$ (제1보). 용매화된 전자의 흡수스펙트럼)

  • Yu-Chul Park;Sang Oh;P. Krebs;U. Schindewolf
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.371-379
    • /
    • 1980
  • The spectral properties of the solvated electrons in tetrahydrofuran(THF)-water binary system have been investigated. In this study, the solvated electrons have been produced by applying nsec Q-switch Nd(YAG) laser photolysis technique. The experimental method photolysis were schematically described. The solvent and the temperature effects on the absorption spectrum of solvated electrons have also been studied. The observation of the spectrum with increasing THF content and temperatue showed a trend that the former shifted to longer wavelength and the other showed broadening effect. The half-life of solvated electrons were also increased with THF content. The absorption maxima of the mixtures were always observed in the middle of that of pure water and THF. The correlation between the volume and the absorption energy of solvated electrons were discussed from the results.

  • PDF

Packaging Design of EPS Cooling Box by Theoretical Heat Flow and Random Vibration Analysis (이론적 열유동 및 랜덤 진동 해석을 적용한 EPS 보냉용기의 포장설계)

  • Kim, Su-Hyun;Park Sang-Hoon;Lee, Min-A;Jung, Hyun-Mo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.27 no.3
    • /
    • pp.175-180
    • /
    • 2021
  • Although it has recently been regulated for use as an eco-friendly policy in Korea, the use of EPS (Expanded Polystyrene) cooling boxes, which are used as cold chain delivery insulation boxes for fresh agricultural and livestock products, is also increasing rapidly as e-commerce logistics such as delivery have increased rapidly due to COVID-19. Studies were conducted to optimize the EPS cooling container through internal air heat flow of CFD (Computational Fluid Dynamics) analysis and FEM (Finite Element Method) random vibration analysis using domestic PSD (Power Spectral Density) profile of the EPS cooling box to which the refrigerant is applied in this study. In the analysis of the internal air heat flow by the refrigerant in the EPS cooling box, the application of vertical protrusions inside was excellent in volume heat flow and internal air temperature distribution. In addition, as a result of random vibration analysis, the internal vertical protrusion gives the rigid effect of the cooling box, so that displacement and stress generation due to vibration during transport are smaller than that of a general cooling container without protrusion. By utilizing the resonance point (frequency) of the EPS cooling box derived by the Model analysis of ANSYS Software, it can be applied to the insulation and cushion packaging design of the EPS product line, which is widely used as insulation and cushion materials.