• Title/Summary/Keyword: Spectral range

Search Result 949, Processing Time 0.026 seconds

NEW INSIGHT ON BROWN DWARF ATMOSPHERES REVEALED BY AKARI

  • Sorahana, S.;Yamamura, I.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.183-184
    • /
    • 2012
  • We present the latest results from the Mission Program NIRLT, the NIR spectroscopic observations of brown dwarfs using the IRC on board AKARI. The near-infrared spectra in the wavelength range between 2.5 and $5.0{\mu}m$ is especially important to study the brown dwarf atmospheres because of the presence of non-blended bands of major molecules, including $CH_4$ at $3.3{\mu}m$, $CO_2$ at $4.2{\mu}m$, CO at $4.6{\mu}m$ and $H_2O$ around $2.7{\mu}m$. Our observations were carried out in the grism-mode resulting in a spectral resolution of ~ 120. In total, 27 sources were observed and 18 good spectra were obtained. We investigate the behavior of three molecular absorption bands, CO, $CH_4$ and $CO_2$, in brown dwarf spectra relative to their spectral types. We find that the $CH_4$ band appears in the spectra of dwarfs later than L5 and CO band is seen in the spectra of all spectral types. $CO_2$ is detected in the spectra of late-L and T type dwarfs.

Binary Power Amplifier with 2-Bit Sigma-Delta Modulation Method for EER Transmitter

  • Lim, Ji-Youn;Cheon, Sang-Hoon;Kim, Kyeong-Hak;Hong, Song-Cheol;Kim, Dong-Wook
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.377-382
    • /
    • 2008
  • A novel power amplifier for a polar transmitter is proposed to achieve better spectral performance for a wideband envelope signal. In the proposed scheme, 2-bit sigma-delta (${\Sigma}{\Delta}$) modulation of the envelope signal is introduced, and the power amplifier configuration is modified in a binary form to accommodate the 2-bit digitized envelope signals. The 2-bit ${\Sigma}{\Delta}$ modulator lowers the noise of the envelope signal by fine quantization and thus enhances the spectral property of the RF signal. The Ptolemy simulation results of the proposed structure show that the spectral noise is reduced by 10 dB in a full transmit band of the EDGE system. The dynamic range is also enhanced. Since the performance is improved without increasing the over-sampling ratio, this technique is best suited for wireless communication with high data rates.

  • PDF

HYPERSPECTRAL IMAGING SPECTROMETER WITH A NOVEL ZOOMING FUNCTION

  • Choi Jin;Kim Tae Hyung;Kong Hong Jin;Lee Jong-Ung
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.213-216
    • /
    • 2005
  • A novel hyperspectral imaging spectrometer controlling spatial and spectral resolution individually has been proposed. This imaging spectrometer uses a zoom lens as a telescope and a focusing element. It can change the spatial resolution fixing the spectral resolution or the spectral resolution fixing the spatial resolution. Here, we report the concept of the hyperspectral imaging spectrometer with the novel zooming function and the optical design of a zoom lens as the focusing element. By using lens module and third-order aberration theory, we have presented the initial design of four-group zoom lens with external entrance pupil. And the optimized zoom lens with a focal length of 50 to 150 mm is obtained from the initial design by the optical design software. As a result, the designed zoom lens shows satisfactory performances in wavelength range of 450 to 900 nm as a focusing element in an imaging spectrometer. Furthermore, the collimator lens of the imaging spectrometer is designed through the third-order aberration correction by using an iterative process.

  • PDF

Simultaneous Determination of Polycyclic Aromatic Hydrocarbons by Near Infrared Spectroscopy using a Partial Least Squares Regression

  • Nam, Jae-Jak;Lee, Sang-Hak;Park, Ju-Eun
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1276-1276
    • /
    • 2001
  • Polycyclic aromatic hydrocarbons(PAHs) are widely distributed in the environment and are often implicated as potential carcinogens. The chromatographic methods of detection and quantitative determination of PAHs in environmental samples are costly, time consuming, and do not account for all kinds of PAHs. This work describes a quantitative spectroscopic method for the analysis of mixtures of eight PAHs using multivariate calibration models for Fourier transform near infrared(FT-NIR) spectral data. The NIR spectra of mixtures of PAHs (anthracene, pyrene, 1,2-benzanthracene, perylene, chrysene, benzo(a)pyrene, 1-methylanthracene and benzo(ghi)perylene) were measured in the wavelength range from 1100 nm to 2500 nm. The spectral data were processed using a partial least squares regression. We have studied the spectral characteristics of NIR spectra of mixtures of PAHs. It was possible to determine each PAM used in this study at the environmental level(mg L-1) in the laboratory samples. Further development may lead to the rapid determination of more PAHs in typical environmental samples.

  • PDF

SOI CMOS image sensor with pinned photodiode on handle wafer (SOI 핸들 웨이퍼에 고정된 광다이오드를 가진 SOI CMOS 이미지 센서)

  • Cho, Yong-Soo;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.341-346
    • /
    • 2006
  • We have fabricated SOI CMOS active pixel image sensor with the pinned photodiode on handle wafer in order to reduce dark currents and improve spectral response. The structure of the active pixel image sensor is 4 transistors APS which consists of a reset and source follower transistor on seed wafer, and is comprised of the photodiode, transfer gate, and floating diffusion on handle wafer. The source of dark current caused by the interface traps located on the surface of a photodiode is able to be eliminated, as we apply the pinned photodiode. The source of dark currents between shallow trench isolation and the depletion region of a photodiode can be also eliminated by the planner process of the hybrid bulk/SOI structure. The photodiode could be optimized for better spectral response because the process of a photodiode on handle wafer is independent of that of transistors on seed wafer. The dark current was about 6 pA at 3.3 V of floating diffusion voltage in the case of transfer gate TX = 0 V and TX=3.3 V, respectively. The spectral response of the pinned photodiode was observed flat in the wavelength range from green to red.

Effect of Grinding on Color and Chemical Composition of Pork Sausages by Near Infrared Spectrophotometric Analyses

  • Kang, J.O.;Park, J.Y.;Choy, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.6
    • /
    • pp.858-861
    • /
    • 2001
  • Near Infrared spectroscopy was applied to the samples of processed pork to see the effect of grinding on chemical components analyses. Data from conventional chemical analyses of moisture, fat, protein, NaCl were put into calibration model by NIR of reflectance mode. The other properties observed were pH and color parameters ($L^*,\;a^*,\;b^*$). Spectral ranges of 400~2500 nm and 400~1100 nm were compared for color parameters. Spectral ranges of 400~2500 nm and 1100~2500 nm were compared for chemical components and pH. Different spectral ranges caused little changes in the coefficients of determination or standard errors. $R^{2,}s$ of calibration models for color parameters were in the range of 0.97 to 1.00. $R^{2,}s$ of calibration models of intact sausages for moisture, protein, fat, NaCl and pH were 0.98, 0.89, 0.95, 0.73 and 0.77, respectively using spectra at 1100~2500 nm. $R^{2,}s$ of calibration models of ground sausages for moisture, protein, fat, NaCl and pH were 0.97, 0.91, 0.97, 0.42 and 0.56, respectively using spectra at 1100~2500 nm.

THE EXTRACTION OF THE THERMAL RADIATION ASSOCIATED WITH GREENHOUSE GASES FROM AIRS MEASUREMENTS

  • Kwon, Eun-Han;Kim, Yong-Seung;Lee, Sun-Gu
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.301-304
    • /
    • 2006
  • For the purpose of investigating the contributions of various gases to climate change, the thermal radiation associated with greenhouse gases are extracted from AIRS (Atmospheric Infrared Sounder) infrared radiances over the tropical pacific region. AIRS instrument which was launched on the EOS-Aqua satellite in May 2002 covers the spectral range from 650 cm-1 to 2700 cm-1 with a spectral resolution of between 0.4 cm-1 and 1 cm-1. In order to extract the thermal radiation absorbed by individual gases, the interfering background radiances at the top of the atmosphere are simulated using the radiative transfer code MODTRAN (MODerate spectral resolution atmospheric TRANsmittance). The simulations incorporated the temperature and water vapor profiles taken from NCEP (National Centers for Environmental Prediction) reanalyses. The differences between the simulated background radiance and AIRS-measured radiance result in the absorption of upward longwave radiation by atmospheric gases (i.e. greenhouse effect). The extracted absorption bands of individual gases will allow us to quantify the radiative forcing of individual greenhouse gases and thus those data will be useful for climate change studies and for the validation of radiative transfer codes used in general circulation models.

  • PDF

The sparse vector autoregressive model for PM10 in Korea (희박 벡터자기상관회귀 모형을 이용한 한국의 미세먼지 분석)

  • Lee, Wonseok;Baek, Changryong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.4
    • /
    • pp.807-817
    • /
    • 2014
  • This paper considers multivariate time series modelling of PM10 data in Korea collected from 2008 to 2011. We consider both temporal and spatial dependencies of PM10 by applying the sparse vector autoregressive (sVAR) modelling proposed by Davis et al. (2013). It utilizes the partial spectral coherence to measure cross correlation between different regions, in turn provides the sparsity in the model while balancing the parsimony of model and the goodness of fit. It is also shown that sVAR performs better than usual vector autoregressive model (VAR) in forecasting.

Aerosol Optical Thickness of the Yellow Sand from Direct Solar Radiation at Anmyon Island during the Spring of 1998 (안면도에서1998년 봄철에 관측된 황사의 광학적 특징)

  • Shin, Do-Shick;Kim, San;Kim, Jeong-Sik;Cha, Ju-Wan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.739-746
    • /
    • 1999
  • The spectral aerosol optical thickness of vertical air columns were measured by a ground-based multi-channel sunphotometer at the BAPMoN station(36$^{\circ}$31'N, 126$^{\circ}$19'E) in Anmyon Island, Korea, from 1 March 1998 to 31 May 1998. We used the data of three yellow sand and two clear sky days in order to analyze the temporal variations in aerosol optical thickness at the station. The basic aerosol optical thickness generally represented smaller than 0.3 in a clear sky and the range 0.5 to 1.1 in yellow sand. Especially the aerosol optical thickness represented larger than 0.9 in a heavy yellow sand. It was found that the aerosol optical thickness of yellow sand was highly increased in comparison with the case of a clear sky andparticles larger than 0.5$mu extrm{m}$ were also increased in the spectral distribution of aerosol volume during yellow sand. Consequently the spectral variations in tropospheric aerosol caused by yellow sand were determined by the number concentration of particles larger than 0.5${\mu}{\textrm}{m}$ and the magnitude of yellow sand.

  • PDF

Determination of Water Content in Ethanol by Miniaturized Near-Infrared (NIR) System

  • Cho, Soo-Hwa;Chung, Hoe-Il;Woo, Young-Ah;Kim, Hyo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.115-118
    • /
    • 2005
  • The miniaturized NIR (Near-infrared) spectrometer has been utilized for the determination of water content (1-19% range) in ethanol that is the most popular organic solvent in pharmaceutical industries. It has many potential capabilities that can replace the conventional analyzers especially for the on-line measurement since it is compact, versatile and cost-effective. By using two dimensional (2D) correlation spectroscopy, it was preliminarily investigated to find any unforeseen spectral distortion among the spectra collected from the miniaturized spectrometer. The 2D study revealed that the spectral variation clearly followed the variation of water concentration without any spectral distortion or abnormality. PLS (Partial Least Squares) was employed to build the calibration model and the resulting prediction performance was acceptable and stable over several days. Even though the miniaturized NIR system was evaluated to fairly simple chemical matrix, the overall study demonstrates the sufficient feasibility for diverse practical and industrial applications.