• Title/Summary/Keyword: Spectral density

Search Result 824, Processing Time 0.028 seconds

High Efficiency Green Phosphorescent Organic Light Emitting Devices using the Emission Layer of (TCTA/TCTA1/3TAZ2/3/TAZ) : Ir(ppy)3 ((TCTA/TCTA1/3TAZ2/3/TAZ) : Ir(ppy)3 발광층을 이용한 고효율 녹색 인광소자)

  • Jang, Ji-Geun;Shin, Sang-Baie;Shin, Hyun-Kwan;Kim, Won-Ki;Ryu, Sang-Ouk;Chang, Ho-Jung;Gong, Myoung-Seon;Lee, Jun-Yeob
    • Korean Journal of Materials Research
    • /
    • v.18 no.7
    • /
    • pp.347-351
    • /
    • 2008
  • We have fabricated and evaluated newNew high high-efficiency green green-light light-emitting phosphorescent devices with an emission layer of [$TCTA/TCTA_{1/3}TAZ_{2/3}/TAZ$] : $Ir(ppy)_3$ were fabricated and evaluated, and compared the electroluminescence characteristics of these devices were compared with the conventional phosphorescent devices with emission layers of ($TCTA_{1/3}TAZ_{2/3}$) : $Ir(ppy)_3$ and (TCTA/TAZ) : $Ir(ppy)_3$. The current density, luminance, and current efficiency of the a device with an emission layer of ($80{\AA}-TCTA/90^{\circ}{\AA}-TCTA_{1/3}TAZ_{2/3}/130{\AA}-TAZ$) : 10%-$Ir(ppy)_3$ were $95\;mA/cm^2$, $25000\;cd/m^2$, and 27 cd/A at an applied voltage of 10 V, respectively. The maximum current efficiency was 52 cd/A under the a luminance value of $400\;cd/m^2$. The peak wavelength and FWHM (FWHM (full width at half maximum) in the electroluminescence spectral were 513 nm and 65 nm, respectively. The color coordinate was (0.30, 0.62) on the CIE (Commission Internationale de I'Eclairage) chart. Under the a luminance of $15000\;cd/m^2$, the current efficiency of the a device with an emission layer of ($80{\AA}-TCTA/90{\AA}-TCTA_{1/3}TAZ_{2/3}/130{\AA}-TAZ$) : 10%-$Ir(ppy)_3$ was 34 cd/A, which has beenshowed an improvement of improved 1.7 and 1.4 times compared to those of the devices with emission layers of ($300{\AA}-TCTA_{1/3}TAZ_{2/3}$) : 10%-$Ir(ppy)_3$ and ($100{\AA}-TCTA/200{\AA}$-TAZ) : 10%-$Ir(ppy)_3$, respectively.

Drone-based Vegetation Index Analysis Considering Vegetation Vitality (식생 활력도를 고려한 드론 기반의 식생지수 분석)

  • CHO, Sang-Ho;LEE, Geun-Sang;HWANG, Jee-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.2
    • /
    • pp.21-35
    • /
    • 2020
  • Vegetation information is a very important factor used in various fields such as urban planning, landscaping, water resources, and the environment. Vegetation varies according to canopy density or chlorophyll content, but vegetation vitality is not considered when classifying vegetation areas in previous studies. In this study, in order to satisfy various applied studies, a study was conducted to set a threshold value of vegetation index considering vegetation vitality. First, an eBee fixed-wing drone was equipped with a multi-spectral camera to construct optical and near-infrared orthomosaic images. Then, GIS calculation was performed for each orthomosaic image to calculate the NDVI, GNDVI, SAVI, and MSAVI vegetation index. In addition, the vegetation position of the target site was investigated through VRS survey, and the accuracy of each vegetation index was evaluated using vegetation vitality. As a result, the scenario in which the vegetation vitality point was selected as the vegetation area was higher in the classification accuracy of the vegetation index than the scenario in which the vegetation vitality point was slightly insufficient. In addition, the Kappa coefficient for each vegetation index calculated by overlapping with each site survey point was used to select the best threshold value of vegetation index for classifying vegetation by scenario. Therefore, the evaluation of vegetation index accuracy considering the vegetation vitality suggested in this study is expected to provide useful information for decision-making support in various business fields such as city planning in the future.

ERS Feature Extraction using STFT and PSO for Customized BCI System (맞춤형 BCI시스템을 위한 STFT와 PSO를 이용한 ERS특징 추출)

  • Kim, Yong-Hoon;Kim, Jun-Yeup;Park, Seung-Min;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.429-434
    • /
    • 2012
  • This paper presents a technology for manipulating external devices by Brain Computer Interface (BCI) system. Recently, BCI based rehabilitation and assistance system for disabled people, such as patient of Spinal Cord Injury (SCI), general paralysis, and so on, is attracting tremendous interest. Especially, electroencephalogram (EEG) signal is used to organize the BCI system by analyzing the signals, such as evoked potential. The general findings of neurophysiology support an availability of the EEG-based BCI system. We concentrate on the event-related synchronization of motor imagery EEG signal, which have an affinity with an intention for moving control of external device. To analyze the brain activity, short-time Fourier transform and particle swarm optimization are used to optimal feature selection from the preprocessed EEG signals. In our experiment, we can verify that the power spectral density correspond to range mu-rhythm(${\mu}8$~12Hz) have maximum amplitude among the raw signals and most of particles are concentrated in the corresponding region. Result shows accuracy of subject left hand 40% and right hand 38%.

Fabrication and Characterization of High Efficiency CBP:Ir(ppy)_3$-PhOLEDs (고효율 $CBP:Ir(ppy)_3$-PhOLEDs의 제작과 특성 연구)

  • Jang, Ji-Geun;Shin, Sang-Baie;Shin, Hyun-Kwan;Ahn, Jong-Myoung;Chang, Ho-Jung;Ryu, Sang-Ouk
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.2
    • /
    • pp.1-6
    • /
    • 2008
  • New devices with the structure of ITO/2-TNATA/NPB/TCTA/CBP:$7%Ir(ppy)_3$/BCP/SFC-137/LiF/Al were designed and fabricated to develop high efficiency green phosphorescent organic light emitting diodes and their electroluminescence properties were evaluated. Among the devices with different thicknesses of CBP in a range of $150{\AA}{\sim}350{\AA}$, the best luminance was obtained in the device with $300{\AA}$-thick CBP host. Nearly saturated current efficiencies indicates that the maximum efficiency value can be obtained with CBP thicknesses of $300{\AA}{\sim}350{\AA}$. The current density, luminance, and current efficiency of the PhOLED(phosphorescent organic light emitting diode) with $CBP(300{\AA}):7%Ir(ppy)_3-emissive$ layer at an applied voltage of 10V were $40mA/cm^2,\;10000cd/m^2$, and 25 cd/A, respectively. The maximum current efficiency was 40.5cd/A under the luminance of $160cd/m^2$. The peak wavelength and FWHM(full width at half maximum) in the electroluminescence spectral were 512nm and 60nm, respectively. The color coordinate was (0.28, 0.63) on the CIE (Commission Internationale de I'Eclairage) chart.

  • PDF

A DCF Throughput Analysis of the Ideal and Fading Channel in the Wireless LAN (무선 LAN에서 이상 및 페이딩 채널 환경의 DCF 처리율 비교 분석)

  • Lee, Yong-Sik;Lee, Ha-Cheol;Lee, Byung-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.7
    • /
    • pp.741-753
    • /
    • 2008
  • This paper explores the throughput performance of CSMA/CA-based DCF protocol over both ideal channels and fading channels with payload size at the MAC layer in the 802.11a wireless LAN. In the ideal channel, there are no errors and at the transmission cycle there is one and only one active station which always has a packet to send and other stations can only accept packets and provide acknowledgements. In the fading channel, bit errors appear in the channel randomly and the number of stations is assumed to be fixed. And each station always has packets for transmission. In other words, we operate in saturation conditions. Up to now conventional research work about DCF throughput analysis of IEEE 802.11 a wireless LAN has been done over the ideal channel, but this paper is done over the Rayleigh/Ricean fading channel. So, the ratio of received average energy per bit-to-noise power spectral density $E_b/N_o$ is set to 25 dB and the ratio of direct-to-diffuse signal power in each sub-channel $\xi$ is set to 6 for combined Rayleigh/Ricean fading channel. In conclusion, it is shown that the saturation throughput is always less than the maximum throughput at all the payload size and the higher the transmission rate be, the higher the decreasing rate of saturation throughput compared to the maximum throughput be.

A Study on the Dynamic Response of Steel Highway Bridges Using 3-D Vehicle Model (3차원(次元) 차량(車輛)모델을 사용(使用)한 강도로교(鋼道路橋)의 동적응답(動的應答) 관(關)한 연구(硏究))

  • Chung, Tae Ju;Park, Young Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.5
    • /
    • pp.1055-1067
    • /
    • 1994
  • This paper is presented to perform linear dynamic analysis of bridges due to vehicle moving on bridges. The road surface roughness and bridge/vehicle interaction are also considered. The bridge and vehicle are modeled as 3-D bridge and vehicle model, respectively. The road surface roughness of the roadway and bridge decks are generated from power spectral density(PSD) function for good road. The PSD function proposed by C.J. Dodds and J.D. Robson is used to describe the road surface roughness for good road condition. The vehicles are modeled as two nonlinear vehicle model with 7-D.O.F of truck and 12-D.O.F of tractor-trailer and the equations of motion of the vehicles are derived using Lagrange's equation. The main girder and concrete deck are modeled as beam and shell element, respectively and rigid link is used between main girder and concrete deck. The equations of motion of the vehicles are solved by Newmark ${\beta}$ method and the equations of the motion of the bridges are solved by mode-superposition procedures. The validity of the proposed procedure is demonstrated by comparing the results with the experimental data reported by the AASHO Road Test. The comparison shows that the agreement between experiment and theory is quite satisfactory.

  • PDF

Application of Residual Statics to Land Seismic Data: traveltime decomposition vs stack-power maximization (육상 탄성파자료에 대한 나머지 정적보정의 효과: 주행시간 분해기법과 겹쌓기제곱 최대화기법)

  • Sa, Jinhyeon;Woo, Juhwan;Rhee, Chulwoo;Kim, Jisoo
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.11-19
    • /
    • 2016
  • Two representative residual static methods of traveltime decomposition and stack-power maximization are discussed in terms of application to land seismic data. For the model data with synthetic shot/receiver statics (time shift) applied and random noises added, continuities of reflection event are much improved by stack-power maximization method, resulting the derived time-shifts approximately equal to the synthetic statics. Optimal parameters (maximum allowable shift, correlation window, iteration number) for residual statics are effectively chosen with diagnostic displays of CSP (common shot point) stack and CRP (common receiver point) stack as well as CMP gather. In addition to removal of long-wavelength time shift by refraction statics, prior to residual statics, processing steps of f-k filter, predictive deconvolution and time variant spectral whitening are employed to attenuate noises and thereby to minimize the error during the correlation process. The reflectors including horizontal layer of reservoir are more clearly shown in the variable-density section through repicking the velocities after residual statics and inverse NMO correction.

Characteristic Radial Pulse Properties of Elderly Females according to Sasang Constitution-based Health Level (고령자 여성의 체질건강수준에 따른 맥파 특성 연구)

  • Kim, Jae Uk;Bae, Jang Han;Ku, Bon Cho;Jeon, Young Ju;Kim, Keun Ho;Kim, Jong Yeol;Kim, Young Min
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.6
    • /
    • pp.970-975
    • /
    • 2012
  • In Sasang constitutional medicine, doctors diagnose and treat patients according to their Sasang consitutition (SC) type. In this work, by a clinical test with a radial pulse tonometer, we investigated radial pulse properties which were significant in distinguishing unhealthy subjects from healthy subjects for each SC type. We measured radial pulse properties on left and right Gwan locations with a pulse tonometer for 299 elderly female subjects of age of 50 years old or above. We used a newly developed SCAT system to determine subjects' SC types. Subjects' health levels of either healthy or unhealthy were determined independently by two Korean medical doctors. To investigate the statistical differences, we used either of Student's t-test or Mann-Whitney U test depending on the normality of distribution of test statistic. For TE type, unhealthy subjects were characterized with significant increases in heart rate, systolic to diastolic period, pulse depth, while they showed significant decreases in width of pulse in normal direction, pulse area in diastolic period, and high harmonic components (6th, 7th) of power spectral density. For SE type, unhealthy subjects were characterized with significant increases in pulse pressure and pulse depth, while no significant differences were found for SY type. We investigated the characteristic differences in radial pulse properties due to change in health levels on each SC type for elderly females. Pulse variables which were significantly different between healthy subjects and unhealthy subjects were found to vary between SC types. For TE type subjects, many variables were found significant at the left Gwan location, which is in support of the theory of hyperactive liver functioning for TE type. Irrespective of the constitution, the related changes in the pulse properties due to worsened health level were in support of elevated blood flow amount in compensation with weakened blood circulatory function.

Detection of Rapid Atrial Arrhythmias in SQUID Magnetocardiography (스퀴드 심자도 장치를 이용한 심방성 부정맥의 측정)

  • Kim Kiwoong;Kwon Hyukchan;Kim Ki-Dam;Lee Yong-Ho;Kim Jin-Mok;Kim In-Seon;Lim Hyun-Kyoon;Park Yong-Ki;Kim Doo-Sang;Lim Seung-Pyung
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.28-35
    • /
    • 2005
  • We propose a method to measure atrial arrhythmias (AA) such as atrial fibrillation (Afb) and atrial flutter (Afl) with a SQUID magnetocardiograph (MCG) system. To detect AA is one of challenging topics in MCG. As the AA generally have irregular rhythm and atrio-ventricular conduction, the MCG signal cannot be improved by QRS averaging; therefore a SQUID MCG system having a high SNR is required to measure informative atrial excitation with a single scan. In the case of Afb, diminished f waves are much smaller than normal P waves because the sources are usually located on the posterior wall of the heart. In this study, we utilize an MCG system measuring tangential field components, which is known to be more sensitive to a deeper current source. The average noise spectral density of the whole system in a magnetic shielded room was $10\;fT/{\surd}Hz(a)\;1\;Hz\;and\;5\;fT/{\surd}Hz\;(a)\;100\;Hz$. We measured the MCG signals of patients with chronic Afb and Afl. Before the AA measurement, the comparison between the measurements in supine and prone positions for P waves has been conducted and the experiment gave a result that the supine position is more suitable to measure the atrial excitation. Therefore, the AA was measured in subject's supine position. Clinical potential of AA measurement in MCG is to find an aspect of a reentry circuit and to localize the abnormal stimulation noninvasively. To give useful information about the abnormal excitation, we have developed a method, separative synthetic aperture magnetometry (sSAM). The basic idea of sSAM is to visualize current source distribution corresponding to the atrial excitation, which are separated from the ventricular excitation and the Gaussian sensor noises. By using sSAM, we localized the source of an Afl successfully.

  • PDF

Strong Carrier Localization and Diminished Quantum-confined Stark Effect in Ultra-thin High-Indium-content InGaN Quantum Wells with Violet Light Emission

  • Ko, Suk-Min;Kwack, Ho-Sang;Park, Chunghyun;Yoo, Yang-Seok;Yoon, Euijoon;Cho, Yong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.293-293
    • /
    • 2014
  • Over last decade InGaN alloy structures have become the one of the most promising materials among the numerous compound semiconductors for high efficiency light sources because of their direct band-gap and a wide spectral region (ultraviolet to infrared). The primary cause for the high quantum efficiency of the InGaN alloy in spite of high threading dislocation density caused by lattice misfit between GaN and sapphire substrate and severe built-in electric field of a few MV/cm due to the spontaneous and piezoelectric polarizations is generally known as the strong exciton localization trapped by lattice-parameter-scale In-N clusters in the random InGaN alloy. Nonetheless, violet-emitting (390 nm) conventional low-In-content InGaN/GaN multi-quantum wells (MQWs) show the degradation in internal quantum efficiency compared to blue-emitting (450 nm) MQWs owing higher In-content due to the less localization of carrier and the smaller band offset. We expected that an improvement of internal quantum efficiency in the violet region can be achieved by replacing the conventional low-In-content InGaN/GaN MQWs with ultra-thin, high-In-content (UTHI) InGaN/GaN MQWs because of better localization of carriers and smaller quantum-confined Stark effect (QCSE). We successfully obtain the UTHI InGaN/GaN MQWs grown via employing the GI technique by using the metal-organic chemical vapor deposition. In this work, 1 the optical and structural properties of the violet-light-emitting UTHI InGaN/GaN MQWs grown by employing the GI technique in comparison with conventional low-In-content InGaN/GaN MQWs were investigated. Stronger localization of carriers and smaller QCSE were observed in UTHI MQWs as a result of enlarged potential fluctuation and thinner QW thickness compared to those in conventional low-In-content MQWs. We hope that these strong carrier localization and reduced QCSE can turn the UTHI InGaN/GaN MQWs into an attractive candidate for high efficient violet emitter. Detailed structural and optical characteristics of UTHI InGaN/GaN MQWs compared to the conventional InGaN/GaN MQWs will be given.

  • PDF