• Title/Summary/Keyword: Spectral calibration

Search Result 254, Processing Time 0.029 seconds

VIMAP: AN INTERACTIVE PROGRAM PROVIDING RADIO SPECTRAL INDEX MAPS OF ACTIVE GALACTIC NUCLEI

  • Kim, Jae-Young;Trippe, Sascha
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.5
    • /
    • pp.195-199
    • /
    • 2014
  • We present a GUI-based interactive Python program, VIMAP, which generates radio spectral index maps of active galactic nuclei (AGN) from Very Long Baseline Interferometry (VLBI) maps obtained at different frequencies. VIMAP is a handy tool for the spectral analysis of synchrotron emission from AGN jets, specifically of spectral index distributions, turn-over frequencies, and core-shifts. In general, the required accurate image alignment is difficult to achieve because of a loss of absolute spatial coordinate information during VLBI data reduction (self-calibration) and/or intrinsic variations of source structure as function of frequency. These issues are overcome by VIMAP which in turn is based on the two-dimensional cross-correlation algorithm of Croke & Gabuzda (2008). In this paper, we briefly review the problem of aligning VLBI AGN maps, describe the workflow of VIMAP, and present an analysis of archival VLBI maps of the active nucleus 3C 120.

Radiometric Cross Calibration of KOMPSAT-3 and Lnadsat-8 for Time-Series Harmonization (KOMPSAT-3와 Landsat-8의 시계열 융합활용을 위한 교차검보정)

  • Ahn, Ho-yong;Na, Sang-il;Park, Chan-won;Hong, Suk-young;So, Kyu-ho;Lee, Kyung-do
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_2
    • /
    • pp.1523-1535
    • /
    • 2020
  • In order to produce crop information using remote sensing, we use classification and growth monitoring based on crop phenology. Therefore, time-series satellite images with a short period are required. However, there are limitations to acquiring time-series satellite data, so it is necessary to use fusion with other earth observation satellites. Before fusion of various satellite image data, it is necessary to overcome the inherent difference in radiometric characteristics of satellites. This study performed Korea Multi-Purpose Satellite-3 (KOMPSAT-3) cross calibration with Landsat-8 as the first step for fusion. Top of Atmosphere (TOA) Reflectance was compared by applying Spectral Band Adjustment Factor (SBAF) to each satellite using hyperspectral sensor band aggregation. As a result of cross calibration, KOMPSAT-3 and Landsat-8 satellites showed a difference in reflectance of less than 4% in Blue, Green, and Red bands, and 6% in NIR bands. KOMPSAT-3, without on-board calibrator, idicate lower radiometric stability compared to ladnsat-8. In the future, efforts are needed to produce normalized reflectance data through BRDF (Bidirectional reflectance distribution function) correction and SBAF application for spectral characteristics of agricultural land.

ERROR PROPAGATION ANALYSIS FOR IN-ORBIT GOCI RADIOMETRIC CALIBRATION

  • Kang, Gm-Sil;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.92-95
    • /
    • 2008
  • The Geostationary Ocean Color Imager (GOCI) is under development to provide a monitoring of ocean-color around the Korean Peninsula from geostationary platforms. It is planned to be loaded on Communication, Ocean, and Meteorological Satellite (COMS) of Korea. The GOCI has been designed to provide multi-spectral data to detect, monitor, quantify, and predict short term changes of coastal ocean environment for marine science research and application purpose. The target area of GOCI observation covers sea area around the Korean Peninsula. Based on the nonlinear radiometric model, the GOCI calibration method has been derived. The radiometric model of GOCI has been validated through radiometric ground test. From this ground test result, GOCI radiometric model has been changed from second order to third order. In this paper, the radiometric test performed to evaluate the radiometric nonlinearity is described and the GOCI radiometric error propagation is analyzed. The GOCI radiometric calibration is based on onboard calibration devices; solar diffuser, DAMD (Diffuser Aging Monitoring Device). The radiometric model error due to the dark current nonlinearity is considered as a systematic error. Also the offset correction error due to gain/offset instability is considered. The radiometric accuracy depends mainly on the ground characterization accuracies of solar diffuser and DAMD.

  • PDF

Design of the IGRINS Calibration System

  • Oh, Hee-Young;Kim, Kang-Min;Lee, Sung-Ho;Jang, Bi-Ho;Lee, Sang-On;Pak, Soo-Jong;Yuk, In-Soo;Chun, Moo-Young;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.155.2-155.2
    • /
    • 2011
  • We present development of the calibration system for IGRINS (the Immersion GRating Infrared Spectrograph). We mainly use Th-Ar and U hollow cathode lamp as the spectral calibration source and telluric features can be used additionally. For the flat source, we selected a 3000K tungsten halogen lamp with 2 inch integrating sphere. From Light Tools simulation, the result flat image through calibration optics satisfied <1% flatness error requirement. We also present mechanical design of calibration box that will be attached on the IGRINS dewar. Three moving stages are designed to perform switching mechanism between all of the observing modes - target observation, flat, precision RV measurement, and spectro-polarimetric observation.

  • PDF

CALIBRATION OF VECTOR MAGNETOGRAMS BY SOLAR FLARE TELESCOPE OF BOAO

  • MOON YONG-JAE;PARK YOUNG DEUK;YUN HONG SIK
    • Journal of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.65-73
    • /
    • 1999
  • In this study we present a new improved nonlinear calibration method for vector magnetograms made by the Solar Flare Telescope of BOAO. To identify Fe I 6302.5 line, we have scanned monochromatic images of the line integrated over filter passband, changing the location of the central transmission wavelength of a Lyot filter. Then we obtained a filter-convolved line profile, which is in good agreement with spectral atlas data provided by the Sacramento Peak Solar Observatory. The line profile has been used to derive calibration coefficients of longitudinal and transverse fields, employing the conventional line slope method under the weak field approximation. Our improved nonlinear calibration method has also been used to calculate theoretical Stokes polarization signals with various angles of inclination of magnetic fields. For its numerical test, we have compared input magnetic fields with the calibrated ones, which have been derived from the new improved non-linear method and the conventional method respectively. The numerical test shows that the calibrated fields obtained from the improved method are consistent with the input fields, but not with those from the conventional method. Finally, we applied our new improved method to a dipole model which characterizes a typical field configuration of a single, round sunspot. It is noted that the conventional method remarkably underestimates the transverse field component near the inner penumbra.

  • PDF

Radiometric Calibration Method of the GOCI (Geostationary Ocean Color Imager)

  • Kang, Gumsil;Myung, Hwan-Chun;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.60-63
    • /
    • 2006
  • Geostationary Ocean Color Imager (GOCI) is under development to provide a monitoring of oceancolor around the Korean Peninsula from geostationary platforms. It is planned to be loaded on Communication, Ocean, and Meteorological Satellite (COMS) of Korea. In this paper radiometric calibration concept of the GOCI is introduced. The GOCI radiometric response is modeled as a nonlinear system in order to reflect a nonlinear characteristic of detector. In this paper estimation approaches for radiometric parameters of GOCI model are discussed. For the GOCI, the offset signal depends on each spectral channel because dark current offset signal is a function of integration time which is different from channel to channel. The offset parameter can be estimated by using offset signal measurements for two integration time setting is described.

  • PDF

Hybrid Linear Analysis Based on the Net Analyte Signal in Spectral Response with Orthogonal Signal Correction

  • Park, Kwang-Su;Jun, Chi-Hyuck
    • Near Infrared Analysis
    • /
    • v.1 no.2
    • /
    • pp.1-8
    • /
    • 2000
  • Using the net analyte signal, hybrid linear analysis was proposed to predict chemical concentration. In this paper, we select a sample from training set and apply orthogonal signal correction to obtain an improved pseudo unit spectrum for hybrid least analysis. using the mean spectrum of a calibration training set, we first show the calibration by hybrid least analysis is effective to the prediction of not only chemical concentrations but also physical property variables. Then, a pseudo unit spectrum from a training set is also tested with and without orthogonal signal correction. We use two data sets, one including five chemical concentrations and the other including ten physical property variables, to compare the performance of partial least squares and modified hybrid least analysis calibration methods. The results show that the hybrid least analysis with a selected training spectrum instead of well-measured pure spectrum still gives good performances, which is a little better than partial least squares.

Rapid Analysis of Melamine Content in Powdered and Liquid Milk Using Fourier Transform Infrared Spectroscopy

  • Wang, Jun;Jun, Soo-Jin;Li, Qing X.
    • Food Science and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.1199-1203
    • /
    • 2009
  • Melamine is a chemical intermediate to manufacture amino resins and plastics, which cannot be used as food additive since it can cause kidney stones. A qualitative determination method of melamine residue in powdered and liquid milk was developed using Fourier transform infrared (FTIR) spectroscopic technique. The calibration sets consisted of 21 standard melamine solutions, in which 1% trichloroacetic acid aqueous solution and acetonitrile (3:1, v/v) were used as solvent. The model was validated using 10 standard melamine solutions which were unused to build up the calibration set. Infrared (IR) absorbance peaks specific to almost all chemical groups in melamine molecule were shown in the spectral range between 1,100 and 1,800/cm. Combined partial least squares (PLS)-$2^{nd}$ derivative calibration model coupled with mean centering (MC) mathematical enhancement showed the highest correlation coefficients ($R^2$>0.99). In brief, the FTIR technique can be used for quantitative analysis of melamine in milk samples.

Radiometric Characteristics of KOMPSAT EOC Data Assessed by Simulating the Sensor Received Radiance

  • Kim, Jeong-Hyun;Lee, Kyu-Sung;Kim, Du-Ra
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.5
    • /
    • pp.281-289
    • /
    • 2002
  • Although EOC data have been frequently used in several applications since the launch of the KOMPSAT-1 satellite in 1999, its radiometric characteristics are not clear due to the inherent limitations of the on-board calibration system. The radiometric characteristics of remotely sensed imagery can be measured by the sensitivity of radiant flux coming from various surface features on the earth. The objective of this study is to analyze the radiometric characteristics of EOC data by simulating the sensor- received radiance. Initially, spectral reflectance values of reference targets were measured on the ground by using a portable spectre-radiometer at the EOC spectrum. A radiative transfer model, LOWTRAN, then simulated the sensor-received radiance values of the same reference target. By correlating the digital number (DN) extracted from the EOC image to the corresponding radiance values simulated from LOWTRAN, we could find the radiometric calibration coefficients for EOC image. The radiometric gain coefficients of EOC are very similar to those of other panchromatic optical sensors.

SOME NOTES ON PHOTOMETRIC OBSERVATIONS: PHOTOELECTRIC PHOTOMETRIC OBSERVATIONS (I)

  • Lee, See-Woo
    • Journal of The Korean Astronomical Society
    • /
    • v.10 no.1
    • /
    • pp.31-38
    • /
    • 1977
  • To reduce the instrumental and calibration errors in the photoelectric photometry as much as possible it is necessary to select the optimum photocell voltage and energy attenaution and to observe as many standard stars as possible over the wide range of color, spectral type and air mass.

  • PDF