• 제목/요약/키워드: Spectral calibration

검색결과 255건 처리시간 0.024초

근적외분광분석법을 이용한 인도메타신의 정량분석 (Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System)

  • 김도형;우영아;김효진
    • 약학회지
    • /
    • 제47권5호
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

Prelaunch Radiometric Performance Analysis of Ocean Scanning Multi-spectral Imager (OSMI)

  • Cho, Young-Min
    • 대한원격탐사학회지
    • /
    • 제16권2호
    • /
    • pp.135-143
    • /
    • 2000
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the Korean Multi-Purpose SATellite (KOMPSAT) to perform global ocean color monitoring for the study of biological oceanography. HOMPSAT was launched 21 December 1999. The radiometric performance of OSMI is analyzed for various gain settings in the viewpoint of the instrument developer for OSMI calibration and application based on its ground performance data measured before launch. The radiometric response linearity and dynamic range are analyzed and the dynamic range is compared with the nominal input radiance for the ocean and the land. The noise equivalent radiance (NER) corresponding to the instrument radiometric noise is compared with the radiometric resolution of signal digitization (1-count equivalent radiance). The best gain setting of OSMI for ocean monitoring is recommended. This analysis is considered to be useful for the OSMI mission and operation planning, the OSMI image data calibration, and users' understanding about OSMI image quality.

Improvement of Calibration Method for a Dual-rotating Compensator Type Spectroscopic Ellipsometer

  • Byeong-Kwan Yang;Jin Seung Kim
    • Current Optics and Photonics
    • /
    • 제7권4호
    • /
    • pp.428-434
    • /
    • 2023
  • The compensators used in spectroscopic ellipsometers are usually assumed to be ideal linear waveplates. In reality, however, they are elliptical waveplates, because they are usually made by bonding two or more linear waveplates of different materials with slight misalignment. This induces systematic error when they are modeled as linear waveplates. We propose an improved calibration method based on an optical model that regards an elliptical waveplate as a combination of a circular waveplate (rotator) and a linear waveplate. The method allows elimination of the systematic error, and the residual error of optic axis measurement is reduced to 0.025 degrees in the spectral range of 450-800 nm.

ACTIVITIES OF CALIBRATION AND VALIDATION FOR THE KOMPSAT-2 MSC DATA

  • Lee Dong-Han;Lee Sun-Gu;Seo Doo-Chun;Song Jeong-Heon;Shih Jae-Min;Kim Yongseung;Lim Hyo-Suk;Paik Hong-Yul
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.620-623
    • /
    • 2005
  • KARI has prepared Calibration and Validation activities for the KOMPSAT-2 (KOrea Multi-Purpose SATellite-2) MSC data that will be launched at the end of this year. Firstly, we divided the Cal/Val activities of it to four parts, Spatial, Spectral, Radiometric and Geometric, and defmed the detailed Cal/Val items from them. Secondly, Cal/Val targets have been defined and manufactured for the role of them. Thirdly, we have made the plan and the procedure for the Cal/Val items, developed the codes for them, studied more detailed method to do them, and trained the Cal/Val activities using the foreign satellite image data by ourselves. KARI has been now setting up the KOMPSAT-2 LEOP plan with the Cal/Val activities, and probably will finish the EOP Cal/Val activities for the KOMPSAT-2 MSC data by the next April or May.

  • PDF

OPTIMISING CALIBRATION TRANSFER TO MEASURE DEGRADABILITY PARAMETERS OF HAYS AND DEHYDRATED FORAGES

  • Andueza, Donato;Munoz, Fernando;Martinez, Adela;De La Roza, Begona
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1268-1268
    • /
    • 2001
  • The availability of in vivo and in sacco degradability values are limited because those methods require work with fistulated animals and are rather complicated, labour intensive and expensive. That is to say, the dynamics and logistics of the methodology result in considerable work, due to limitations on the amount of samples, number of bags that can be placed in an animal and different time intervals to perform kinetic studies. Therefore, a simpler method is necessary to estimate the degradation characteristics of the feed. In this way, near infrared reflectance spectroscopy has been used to predict degradation characteristics of forages. In other hand, the possibility of achieving successful transfer of spectra and equations between instruments is closely related. The objective of this study was to confirm the potential of NIR to optimize work conditions to avoid duplicated efforts in collaborative trials on animal feeds evaluation between research institutions. For this purpose, one set with forty hays and dehydrated forages samples from SERIDA and ten samples with the same characteristics from SIA, were be used to create a spectral database. A calibration was developed using samples from degradation essays made in SERIDA to predict dry matter and crude protein degradability. With the addition of five samples from SIA in original calibration set, the effect of different origin and location was compensated.

  • PDF

근적외선 분광기술을 이용한 휴대용 감귤 당도 선과기 성능특성에 관한 연구 (A Study on the Performance Characteristics of Portable Analyzer for Determination of Sugar Content in Citrus Unshiu using Near Infrared Spectroscopy)

  • 윤성운;마상동;김명윤;김재열
    • 한국공작기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to develop to portable near infrared analyzer measuring the sugar content of the fruits on a tree before harvesting ones. The portable near infrared system consists of a tungsten lamp, a coaxial optical fiber bundle and a multi-channel detector, which has 256 pixels and a concave transmission grating. Reflectance NIR spectra of orange were recorded by using a coaxial optical fiber bundle. The spectra were collected over the spectral range $400{\sim}1100nm$. Partial least squares regression(PLSR) was applied for a calibration and validation for determination of sugar contents. The multiple correlation coefficient was 0.99 and standard errors of calibration(SEC) was 0.069 brix. The calibration model predicted the sugar content for validation set with standard errors of prediction(SEP) of 0.092 brix. The sugar content in fruits was successfully quantified using the portable near infrared analyzer.

Updating calibration of CIV-based single-epoch black hole mass estimators

  • Park, Daeseong;Barth, Aaron J.;Woo, Jong-Hak;Malkan, Matthew A.;Treu, Tommaso;Bennert, Vardha N.;Pancoast, Anna
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.61.1-61.1
    • /
    • 2016
  • Black hole (BH) mass is a fundamental quantity to understand BH growth, galaxy evolution, and connection between them. Thus, obtaining accurate and precise BH mass estimates over cosmic time is of paramount importance. The rest-frame UV CIV ${\lambda}1549$ broad emission line is commonly used for BH mass estimates in high-redshift AGNs (i.e., $2{\leq}z{\leq}5$) when single-epoch (SE) optical spectra are available. Achieving correct and accurate calibration for CIV-based SE BH mass estimators against the most reliable reverberation-mapping based BH mass estimates is thus practically important and still useful. By performing multi-component spectral decomposition analysis to obtained high-quality HST UV spectra for the updated sample of local reverberation-mapped AGNs including new HST STIS observations, CIV emission line widths and continuum luminosities are consistently measured. Using a Bayesian hierarchical model with MCMC sampling based on Hamiltonian Monte Carlo algorithm (Stan NUTS), we provide the most consistent and accurate calibration of CIV-based BH mass estimators for the three line width characterizations, i.e., full width at half maximum (FWHM), line dispersion (${\sigma}_{line}$), and mean absolute deviation (MAD), in the extended BH mass dynamic range of log $M_{BH}/M_{\odot}=6.5-9.1$.

  • PDF

Studies on 5 Protein Fractions Prediction of Forage Legume Mixture by NIRS

  • Lee, Hyo-Won;Jang, Sungkwon;Lee, Hyo-Jin;Park, Hyung-Soo
    • 한국초지조사료학회지
    • /
    • 제34권3호
    • /
    • pp.214-218
    • /
    • 2014
  • This study was conducted to assess the feasibility of near-infrared reflectance spectroscopy (NIRS) as a rapid and reliable method for the estimation of crude protein (CP) fractions in forage legume mixtures (sudangrass and pea mixture, and kidney bean and potato mixture). A total of 178 samples were collected and their spectral reflectance obtained in the range of 400~2,500 nm. Of these, 50 samples were selected for calibration and validation, and 35 samples were used for calibration of the data set, and the modified partial least square regression (MPLSR) analysis was performed. The correlation coefficient ($r^2$) and the standard error of cross-validation (SECV) of the calibration models in the CP fractions, A, B1, B2, B3, and C, were 0.94 (1.05), 0.92 (0.74), 0.96 (0.95), 0.91 (0.42), and 0.83 (0.38), respectively. Fifteen samples were used for equation validation, and the $r^2$ and the standard error of prediction (SEP) were 0.87 (1.45), 0.91 (0.49), 0.94 (1.13), 0.36 (0.96), and 0.74 (0.67), respectively. This study showed that NIRS could be an effective tool for the rapid and precise estimation of CP fractions in forage legume mixtures.

현장관측용 분광 광도계의 상대 검교정 시스템 개발 (Development of relative radiometric calibration system for in-situ measurement spectroradiometers)

  • 오은송;안기범;강혁모;조성익;박영제
    • 대한원격탐사학회지
    • /
    • 제30권4호
    • /
    • pp.455-464
    • /
    • 2014
  • 천리안해양관측위성(Geostationary Ocean Color Imager, GOCI)이 2010년 6월에 발사된 이후, 영상 자료의 보정과 검증을 위한 여러 차례의 현장 관측이 한반도 주변에서 수행되었다. 한국해양과학기술원 해양위성센터(Korea Ocean Satellite Center, KOSC)에서는 Analytical Spectral Devices (ASD)사의 분광 광도계 FieldSpec3나 TriOS사의 분광 광도계 RAMSES와 같은 현장관측장비의 특성 변화를 확인하기 위하여 미국국립표준기술원(National Institute of Standards and Technology, NIST)의 표준화 절차를 거친 광원과 표준 분광 광도계를 이용하여 각각의 현장 관측 마다 기기의 성능을 측정하였다. 본 논문에서는 해양위성센터에 구축된 광학 실험실과 현장관측 분광 광도계의 상대적 복사 검교정 방법에 대해서 소개하고 있다. 광학 실험실은 98% 이상의 광원 균질성을 지니는 20인치 적분구(USS-2000S, LabSphere)와 360 nm 부터 1100 nm 까지 1.6 nm 파장 간격으로 측정이 가능한 표준 분광 광도계(MCPD9800, Photal), 그리고 ${\pm}0.1mm$의 편평도를 가지는 광학테이블($3600{\times}1500{\times}800mm^3$)을 기본으로 구성되어 있다. 실험실 내부는 정확한 검교정 실험을 위하여 일정한 온습도를 유지하고 있으며, 동일한 광원에 동일한 위치에서 표준과 현장관측용 분광 광도계를 동시에 측정하는 방법을 기본으로 한다. 해양위성센터가 보유하고 있는 ASD 를 측정한 결과, 현장관측용 분광광도계의 결과가 푸른 가시광 영역에서 미세한 차이가 측정 시 마다 나타나는 것을 확인하였고, 더불어 1년간의 상대 검교정 실험에 따르면 평균적으로 4.41% 정도의 파장별 광특성이 변화하는 것을 확인하였다. 이러한 결과는 측정 정확도를 유지하고, GOCI 자료의 신뢰도를 확보하기 위하여 지속적인 검교정 실험을 수행해야 하는 이유를 보여주고 있다.

Application of Near Infrared Spectroscopy for Nondestructive Evaluation of Nitrogen Content in Ginseng

  • Lin, Gou-lin;Sohn, Mi-Ryeong;Kim, Eun-Ok;Kwon, Young-Kil;Cho, Rae-Kwang
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1528-1528
    • /
    • 2001
  • Ginseng cultivated in different country or growing condition has generally different components such as saponin and protein, and it relates to efficacy and action. Protein content assumes by nitrogen content in ginseng radix. Nitrogen content could be determined by chemical analysis such as kjeldahl or extraction methods. However, these methods require long analysis time and result environmental pollution and sample damage. In this work we investigated possibility of non-destructive determination of nitrogen content in ginseng radix using near-infrared spectroscopy. Ginseng radix, root of Panax ginseng C. A. Meyer, was studied. Total 120 samples were used in this study and it was consisted of 6 sample sets, 4, 5 and 6-year-old Korea ginseng and 7, 8 and 9-year-old China ginseng, respectively. Each sample set has 20 sample. Nigrogen content was measured by electronic analysis. NIR reflectance spectra were collected over the 1100 to 2500 nm spectral region with a InfraAlyzer 500C (Bran+Luebbe, Germany) equipped with a halogen lapmp and PbS detector and data were collected every 2 nm data point intervals. The calibration models were carried out by multiple linear regression (MLR) and partial least squares (PLS) analysis using IDAS and SESAME software. Result of electronic analysis, Korean ginseng were different mean value in nitrogen content of China ginseng. Ginseng tend to generally decrease the nitrogen content according as cultivation year is over 6 years. The MLR calibration model with 8 wavelengths using IDAS software accurately predicted nitrogen contents with correlation coefficient (R) and standard error of prediction of 0.985 and 0.855%, respectively. In case of SESAME software, the MLR calibration with 9 wavelength was selected the best calibration, R and SEP were 0.972 and 0.596%, respectively. The PLSR calibration model result in 0.969 of R and 0.630 of RMSEP. This study shows the NIR spectroscopy could be applied to determine the nitrogen content in ginseng radix with high accuracy.

  • PDF