• Title/Summary/Keyword: Spectral Imaging

Search Result 388, Processing Time 0.032 seconds

Investigation of Ground Remote Sensing Technique Using CCD Camera (CCD 카메라를 이용한 지상원격탐사 기술 개발)

  • Kim, Eung Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2D
    • /
    • pp.325-333
    • /
    • 2006
  • Recently, in the case of observing the global environment, satellite remote sensing technology has been important. It's because satellite remote sensing is valuable for assessing relatively large areas. But now, small scale remote sensing techniques are needed which can be applicable to the detail investigation of plant tree areas which afforest land after the large scale construction of roads, dams and airports. In this study, we tried to develop and propose a lower altitude sensing technique which can be used in ground remote sensing by using a CCD camera. As a result of this investigation the following can be concluded: We recognized the transference characteristics of filters which were used in comparative tests about the four ground remote sensing devices. We also found that the near-IR camera could be used for an imaging spectral radiometer in the extraction of the vegetation index. Furthermore, we found that the vegetation index has varied hour by hour during the day of the experiment. Finally, we brought about an increase phase of the NDVI in a forest fire, which caused considerable damage, by developing new ground remote sensing technology.

Effect of Red-edge Band to Estimate Leaf Area Index in Close Canopy Forest (울폐산림의 엽면적지수 추정을 위한 적색경계 밴드의 효과)

  • Lee, Hwa-Seon;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_1
    • /
    • pp.571-585
    • /
    • 2017
  • The number of spaceborne optical sensors including red-edge band has been increasing since red-edge band is known to be effective to enhance the information content on biophysical characteristics of vegetation. Considering that the Agriculture and Forestry Satellite is planning to carry an imaging sensor having red-edge band, we tried to analyze the current status and potential of red-edge band. As a case study, we analyzed the effect of using red-edge band and tried to find the optimum band width and wavelength region of the red-edge band to estimate leaf area index (LAI) of very dense tree canopy. Field spectral measurements were conducted from April to October over two tree species (white oak and pitch pine) having high LAI. Using the spectral measurement data, total 355 red-edge bands reflectance were simulated by varying five band width (10 nm, 20 nm, 30 nm, 40 nm, 50 nm) and 71 central wavelength. Two red-edge based spectral indices(NDRE, CIRE) were derived using the simulated red-edge band and compared with the LAI of two tree species. Both NDRE and CIRE showed higher correlation coefficients with the LAI than NDVI. This would be an alternative to overcome the limitation of the NDVI saturation problem that NDVI has not been effective to estimate LAI over very dense canopy situation. There was no significant difference among five band widths of red-edge band in relation to LAI. The highest correlation coefficients were obtained at the red-edge band of center wavelength near the 720 nm for the white oak and 710 nm for the pitch pine. To select the optimum band width and wavelength region of the red-edge band, further studies are necessary to examine the relationship with other biophysical variables, such as chlorophyll, nitrogen, water content, and biomass.

The Development of Theoretical Model for Relaxation Mechanism of Sup erparamagnetic Nano Particles (초상자성 나노 입자의 자기이완 특성에 관한 이론적 연구)

  • 장용민;황문정
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.39-46
    • /
    • 2003
  • Purpose : To develop a theoretical model for magnetic relaxation behavior of the superparamagnetic nano-particle agent, which demonstrates multi-functionality such as liver- and lymp node-specificity. Based on the developed model, the computer simulation was performed to clarify the relationship between relaxation time and the applied magnetic field strength. Materials and Methods : The ultrasmall superparamagnetic iron oxide (USPIO) was encapsulated with biocompatiable polymer, to develop a relaxation model based on outsphere mechanism, which was resulting from diffusion and/or electron spin fluctuation. In addition, Brillouin function was introduced to describe the full magnetization by considering the fact that the low-field approximation, which was adapted in paramagnetic case, is no longer valid. The developed model describes therefore the T1 and T2 relaxation behavior of superparamagnetic iron oxide both in low-field and in high-field. Based on our model, the computer simulation was performed to test the relaxation behavior of superparamagnetic contrast agent over various magnetic fields using MathCad (MathCad, U.S.A.), a symbolic computation software. Results : For T1 and T2 magnetic relaxation characteristics of ultrasmall superparamagnetic iron oxide, the theoretical model showed that at low field (<1.0 Mhz), $\tau_{S1}(\tau_{S2}$, in case of T2), which is a correlation time in spectral density function, plays a major role. This suggests that realignment of nano-magnetic particles is most important at low magnetic field. On the other hand, at high field, $\tau$, which is another correlation time in spectral density function, plays a major role. Since $\tau$ is closely related to particle size, this suggests that the difference in R1 and R2 over particle sizes, at high field, is resulting not from the realignment of particles but from the particle size itself. Within normal body temperature region, the temperature dependence of T1 and T2 relaxation time showed that there is no change in T1 and T2 relaxation times at high field. Especially, T1 showed less temperature dependence compared to T2. Conclusion : We developed a theoretical model of r magnetic relaxation behavior of ultrasmall superparamagnetic iron oxide (USPIO), which was reported to show clinical multi-functionality by utilizing physical properties of nano-magnetic particle. In addition, based on the developed model, the computer simulation was performed to investigate the relationship between relaxation time of USPIO and the applied magnetic field strength.

  • PDF

Baseline Survey Seismic Attribute Analysis for CO2 Monitoring on the Aquistore CCS Project, Canada (캐나다 아퀴스토어 CCS 프로젝트의 이산화탄소 모니터링을 위한 Baseline 탄성파 속성분석)

  • Cheong, Snons;Kim, Byoung-Yeop;Bae, Jaeyu
    • Economic and Environmental Geology
    • /
    • v.46 no.6
    • /
    • pp.485-494
    • /
    • 2013
  • $CO_2$ Monitoring, Mitigation and Verification (MMV) is the essential part in the Carbon Capture and Storage (CCS) project in order to assure the storage permanence economically and environmentally. In large-scale CCS projects in the world, the seismic time-lapse survey is a key technology for monitoring the behavior of injected $CO_2$. In this study, we developed a basic process procedure for 3-D seismic baseline data from the Aquistore project, Estevan, Canada. Major target formations of Aquistore CCS project are the Winnipeg and the Deadwood sandstone formations located between 1,800 and 1,900 ms in traveltime. The analysis of trace energy and similarity attributes of seismic data followed by spectral decomposition are carried out for the characterization of $CO_2$ injection zone. High trace energies are concentrated in the northern part of the survey area at 1,800 ms and in the southern part at 1,850 ms in traveltime. The sandstone dominant regions are well recognized with high reflectivity by the trace energy analysis. Similarity attributes show two structural discontinuities trending the NW-SE direction at the target depth. Spectral decomposition of 5, 20 and 40 Hz frequency contents discriminated the successive E-W depositional events at the center of the research area. Additional noise rejection and stratigraphic interpretation on the baseline data followed by applying appropriate imaging technique will be helpful to investigate the differences between baseline data and multi-vintage monitor data.

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

Radiologic Findings of Cervical Mass Type Cervical Pregnancy (자궁경부 종괴형 자궁경부임신의 영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.43-51
    • /
    • 2005
  • Background: To examine the ultrasonographic and magnetic resonance (MRI) imaging findings of a cervical mass type cervical pregnancy. Materials and Methods: The ultrasonographic and MRI findings of 5 patients pathologically confirmed as having a cervical pregnancy were analyzed retrospectively. On ultrasonography, the size and echo pattern of the uterine cervix, the shape and echo pattern of the lesion, the degree and the pattern of blood flow on the color Doppler study and the spectral Doppler pattern were analyzed. The shape, signal intensity, and degree and pattern of enhancement of the lesion were evaluated on MRI. Results: The uterine cervix was enlarged and the size of the lesion was 6.1 to 7.1 (average, 6.5) cm. The endocervical canal was irregularly dilated and showed heterogeneous echogenicity in all 5 cases. Four of the 5 lesions were heterogeneously hyper- or mixed echoic and remaining one was relatively homogeneous echogenic. Doppler ultrasonography revealed an increased vascularity of the peritrophoblastic flow pattern. In all 4 cases where MRI performed, the lesion was irregular in shape and the margin was not sharply demarcated. The T2-weighed image showed that the lesions were mixed signal intensity. Three of the 4 lesions contained high signal intensity nodular portions and a low signal intensity rim was observed along the margin of the nodular portions. The T1-weighted image revealed multiple signal voids along the periphery of the lesions and high signal intensity portions as a result of hemorrhage were noted. The dynamic enhanced study showed that the high signal intensity portions on the T2-weighted image were strongly enhanced similar to the vessels on the early phase and the contrast enhancement gradually decreased with time. Conclusion: A cervical mass type cervical pregnancy can be correctly diagnosed using the patient's clinical symptom, the elevation in the serum ${\beta}$-HCG level, and characteristic ultrasonographic and MRI findings.

  • PDF

Evaluation of Articular Cartilage using 3D FFE-PROSET Technique in 3.0 T Knee MR Imaging : Comparison with 2D TSE - SPIR Technique (3.0T 무릎자기공명영상에서 3차원 FFE-PROSET 기법을 이용한 관절연골평가 : 2차원 TSE-SPIR 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.599-606
    • /
    • 2013
  • The purpose of this study is to know a clinical usefulness for delineation of articular cartilage compared with 2D TSE-SPIR and 3D FFE-PROSET technique. From January 2013 to september 2013, a total of 30 normal volunteers(12 men and 18 women aged between 35 and 55 years; mean 49.48 years) were studied on a philips 3.0T MRI scanner. As a quantitative analysis, SNRs and CNRs were evaluated by using two methods for delineation of articular cartilage. As a qualitative analysis, image quality was evaluated by special radiological technologist of MRI for image delineation on a three grade. As a results, SNRs and CNRs for articular cartilage were significantly greater for the 3D FFE-PROSET(SNRs: 8.40, 114.02, 9.53, CNRs: 104.49, 139.49) technique compared to 2D TSE-SPIR(SNRs: 4.41, 71.63, 7.34, CNRs: 64.30, 58.41) technique, image quality also was higher for evaluation of 3D FFE-PROSET(2.40) technique(p=0.0021). In conclusion, this study showed that a 3D FFE-PROSET MRI has improved SNRs and CNRs for evaluating of the articular cartilage, these conclusions in the future will be provided useful information in diagnosis of articular cartilage.

Numerical Design of Double Quantum Coherence Filter for the Detection of Myo-Inositol In vivo (인체 내 myo-Inositol 검출을 위한 수치해석적 이중양자 필터 디자인)

  • Lee, Yun-Jung;Jung, Jin-Young;Noh, Hyung-Joon;Yu, Ung-Sik;Kim, Hyeon-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.117-126
    • /
    • 2009
  • Purpose : A numerical method of designing a multiple quantum filter (MQF) is presented for the optimum detection of myo-inositol (mI), an important brain metabolite, by using in vivo proton nuclear magnetic resonance spectroscopy ($^1$-HMRS). Materials and Methods : Starting from the characterization of the metabolite, the filter design includes the optimization of the sequence parameters such as the two echo times (TEs), the mixing time (TM), and the flip angle and offset frequency of the 3rd $90^{\circ}$ pulse which converts multiple quantum coherences (MQCs) back into single quantum coherences (SQCs). The optimized filter was then tested both in phantom and in human brains. Results : The results demonstrate that the proposed MQF can improve the signal-to-background ratio of the target metabolite by a factor of more than three by effectively suppressing the signal from the background metabolites. Conclusion : By incorporating a numerical method into the design of MQFs in $^1$-HMRS the spectral integrity of a target metabolite, in particular, with a complicated spin system can be substantially enhanced.

  • PDF

Usefulness of the PRESS Technique using 3.0T Magnetic Resonance Spectroscopy for Evaluation of Non-Alcoholic Fatty Liver Disease Patients (비알콜성 지방간환자 평가를 위한 3.0T 고자기장 자기공명분광법을 이용한 PRESS 기법의 유용성)

  • Goo, Eun-Hoe
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5931-5936
    • /
    • 2012
  • This study was to evaluate the clinical usefulness of the PRESS technique based on the correlation between PRESS technique and biopsy results by applying 3.0T high magnetic field MRS technique for evaluation of non-alcoholic fatty liver disease patients. This experiment were carried out using a 3.0T magnetic resonance imaging equipment. The part data of each spectrum is taken by peak area integration. The part data of resonance peak was used to calculate relative ratio. MR spectral peak in patients with non-alcoholic fatty liver disease is from 0.9 to 1.6 ppm. According to MRS method study result, Patients with NAFLD were obtained with 94% sensitivity and 80% specificity(p=0.000). When compared to normal based on MRS and Biopsy results was valid correlation(r=0.79, p=0.04). Results for NAFLD(r=0.89, p=0.002) also showed a correlation. Therefore, PRESS technique to evaluate patients with non-alcoholic fatty liver disease, the distribution difference between normal liver and fatty liver part is significantly distinguished. Biopsy and MRS fatty liver peak ratio(%) proves high lipid over grade(r = 0.7).

OVI EMISSION LINE DETECTION LIMIT OF FAR-ULTAVIOLET IMAGING SPECTROGRAPH (과학위성 1호 탑재체 원자외선 분광기의 OVI 방출선 검출 한계)

  • 선광일;유광선;육인수;박장현;남욱원;한원용;선종호;민경옥
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.77-86
    • /
    • 2000
  • There have been a few attempts to measure diffuse line emission between 900 $\AA$ and 1200 $\AA$, and only in a limited number of sight lines has it been detected. The main contributions to the equilibrium radiative cooling curve between $10^{4.5}K\;to\;10^6K$ are from the doublet of Ovi ${lambda}{lambda}1032;and;{lambda}{lambda}1038$ in the FUV spectral region. There are several bright airglow lines which could interfere with attempts to observe the OVI lines. The nearest lines HI 1025 $\AA$, OI 1027 $\AA$ have a combined intensity of about $10^{5.5}$ photons/s/$cm^2$/sr. In the present study, the detectability simulation of OVI doublet is performed using a Monte-Carlo technique and chi-square statistics. The analysis results are compared with the previous observations and with the predictions of several interstellar medium models, and are used to limit manufacturing and alignment errors of FIMS optical system.

  • PDF