• Title/Summary/Keyword: Spectacle lenses

Search Result 27, Processing Time 0.024 seconds

A Comparative Study of Ophthalmic Spectacle Lenses Standards (시력보정용 안경렌즈의 규격에 관한 비교 고찰)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.397-415
    • /
    • 2004
  • This study surveyed differences among KS, ISO, JIS and ANSI ophthalmic spectacle lenses standards. These standards applied to several lenses that were in common currency and we checked over problems and improvements in KS. KS corresponded to ISO, for the most part, and ANSI, partly. But terms, definitions, progressive power lenses standards, UV transmittance and base curves clauses did not exist in KS. There was no differences between nominal data and actual data in important clauses estimation-minimum requirements on refractive power, tolerances on the size of lenses, material and surface quality. But tolerances of thickness, base curves, UV and visible transmittance values were not existing, there were differences among several ophthalmic spectacle lenses in the test of these clauses. These requirements will be needed for better and more comfortable vision.

  • PDF

Front Radius of Spherical Spectacle Lens in the Cosmetic and the Optical Corsiderations (구면 안경렌즈의 미용적 측면에서의 곡률반경과 광학적 고찰)

  • Jung, Boo-Young;Joo, Kyung-Bok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.405-410
    • /
    • 2005
  • In this paper, the front radiuses of curvature of spherical spectacle lenses in the cosmetic and optical point of view are investigated and are calculated using Zinken-Sommer condition. The optical power of all spherical spectacle lens shows good quality at the test using autometic lensmeter. However the front radiuses of curvature of spherical spectacle lenses are quite different depending on the lens companies. The front radius of curvature of those lenses is larger than that calculated using Zinken-Sommer condition. We know that the front radius of curvature of commercial spectacle lens is emphasized more cosmetic aspect than optical point of view.

  • PDF

The Research on the Optical Reliability of Spectacle Lens in Korea (국내 안경렌즈 광학적 요소 신뢰성 조사)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.43-48
    • /
    • 2008
  • Purpose: This study is to evaluate reliability of geometrical optics properties of spectacle lenses by using ISO and the medical instrument standard of KFDA, which are being sold in Korea. Methods: We used samples of three hundred and ninety eight spectacle lenses of eight company in total. Refractive indices of each samples which were used in experiment were classified into three groups of medium index (1.55~1.56), high index (1.60~1.61) and extra high index (1.67). Results: Conformity of refractive power was 81.61% in total spectacle lenses. The results showed that thickness conformity 90%, appearance conformity 85.18%, size conformity 96.23% and optical center point conformity 99.50% in total. Conclusions: We found that they deviated from the permitting value in many spectacle lenses on refractive power. The results of errors on prism power, surface inspection and optical center point showed small values in total products. In experiment of lens size and thickness, the bulk of indication rates and conformities of samples deviated from the permitting errors.

  • PDF

Convergence study of comparison of blue light blocking rate between colored lenses of various colors and dental tips (다양한 색상의 착색렌즈와 치과용 팁의 청광차단율 비교의 융합적 연구)

  • Lee, Sook-Jeong
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.7
    • /
    • pp.61-67
    • /
    • 2021
  • The purpose of this study was to investigate the colors of spectacle lenses that would be effective in blocking blue light among various colors so that the damage caused by blue light could be conveniently reduced even in daily life and when filling with dental light-curing resin. Each color dye of orange, brown, gray, yellow, red, and rosa was dissolved in an individual container of a spectacle lens tinting machine, and 6 uncolored spectacle lenses were immersed in a temperature of 90℃ for 1 hour to color. As a result of comparing the blue light transmittance of the colored spectacle lens and the tip for the photopolymerizer, the blue light transmittance of the orange colored lens was 0.82%, and the blue light blocking effssect was the best. Brown and gray tinted lenses had excellent blue light blocking rate, but it was difficult to recognize objects through the lens due to the high tinted concentration, and yellow tinted lenses were found to be effective when the tint was similar to the tip. The blue tinted lens had a blue light transmittance of 15.10%, which was lower than other tinted lenses. The results of the experimental study are expected to be helpful in recognizing the blue light transmittance by spectacle tinted lenses of various colors and making efforts to select the appropriate blue light blocking lens color and block harmful blue light stimuli.

Comparison of Contrast Sensitivity Between Soft Contact Lens Wearers and Spectacle Wearers (콘택트렌즈와 안경 착용자의 대비감도 비교)

  • Kim, Jai-Min;Lee, Min-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • The aim of the present study was to compare the contrast sensitivity of soft contact lens wearers, spectacle wearers or emmetropia. Seventy myopic eyes and thirty emmetropic eyes aged 19 to 26 years were collected. The myopic group included 48 eyes corrected with spectacle lenses and 22 eyes of them corrected with contact lenses, too: all had corrected vision acuity of 20/20 or better. Spatial contrast sensitivity was measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView  Functional Vision Analysis software at photopic or mesoopic condition. There was no significant difference in contrast sensitivity between spectacle lenses and emmetropes. Myopes corrected with soft contact lenses showed statistical sensitivity losses at 1.5, 12 cycle/degree spatial frequencies. In conclusion, our findings suggest that loss of contrast sensitivity in soft contact lens wearers might be interpreted as evidence for corneal disruption before corneal pathological events occur in contact lens wearers. Contrast sensitivity testing appears to be a useful method for evaluating soft contact lenses.

  • PDF

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

Assessment of UV Blocking Performance for Development of Converged Technologies of Vision Correcting Spectacle Lenses (시력교정용 안경렌즈의 융복합적 기술개발을 위한 UV차단 성능 평가)

  • Kim, Heung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.93-98
    • /
    • 2018
  • This study was wanted to confirm ability for UV blocking according to its material. The lenses materials were Acryl, CR-39, NK-55, and MR-8. It was grouped: Group A consisting of anti-scratch hard coated lenses and anti-refractive multi coated lenses, Group B added UV blocking coating on the group A, and Group C consisting of only UV blocking lenses. The results measured UV transmittance, On the UV-A wavelength, Group A showed the UV transmittance of 7.726%, 0.043%, 0.007%, and 0.007% respectively. Group B showed 0.038%, 0.037%, 0.007%, and 0.007%, respectively. The UV-blocking performance of CR-39 has been greatly improved. Group C has shown the best UV blocking function; only 0.005% and 0.004% of UV transmittances.(1.60 and 1.67 index of refraction respectively). For the low power of lenses and sunglasses, the CR-39 lens is the most used. Therefore, to UV blocking from the lens, new materials or UV absorbers or UV coating technology and development of Converged Technologies are required.

Effects of Stray Light in Blue-light Blocking Lens on the Quality of Image (청색광 차단렌즈에서 미광이 상의 질에 미치는 영향)

  • Yuk, Ju Sung;Yang, Seok-Jun;Kim, Yong Gwon;Choi, Eun Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.612-618
    • /
    • 2016
  • The aim of this study is to investigate the effects of stray light originating from the blue-light blocking lens on the quality of the image. After designing the ideal spectacle lens, anti-reflection spectacle lens without internal reflection, anti-reflection spectacle lens with internal reflection, and blue-light blocking lens with internal reflection, the light intensity distribution and stray light distribution were derived. The designed spectacle lenses are meniscus lenses with a refractive power of 0.00 D, refractive index of 1.56, and a radius of 155.15 mm. The peaks of reflectance of the 4 types of blue-light blocking lenses are in the range between 430 nm and 440 nm, and their reflectances are 5%, 10%, 15%, and 20%, respectively. According to the analysis results, as the reflectance of the blue-light blocking lens increases, the light intensity in the center of the lens decreases and the intensity of the stray light in the center-periphery and periphery of the lens increases. This trend appeared to intensify with increasing reflectance of the blue-light blocking lenses. Because the increase in the reflectance of the blue-light blocking lens degrades the quality of the image by increasing the intensity of the stray light in the center-periphery and periphery of the lens, its reflectance needs to be adjusted by varying the blue-light blocking ratio and the luminous transmittance, in order to diminish the level of visual discomfort.

The Performance Analysis and Design of Selling Spectacle Lenses in Domestic Market (국내 시판 안경렌즈의 성능 분석 및 설계)

  • Kim, Se-Jin;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.355-360
    • /
    • 2010
  • Purpose: Analysis performance for spectacle lens which sales in domestic market and optimization design a spectacle lens which is corrected aberration. Methods: Measured center thickness, radius and aspherical surface coefficient for spherical and aspherical lenses which were ${\pm}$5.00D. Refractive index for every lens was 1.6 and they came from 4 different companies. I used 3 types of equipment to measure lenses. ID-F150 (Mitutoyo) : Center Thickness, FOCOVISION (SR-2, Automation Robotics) : Radius, PGI 1240S (Taylor Hobson) : Aspherical surface coefficient. Designed a lens which had 27 mm of distance from lens rear surface to center of eye, 4 mm of pupil diameter and small aberration on center vision $30^{\circ}C$. To shorten axial distance compared with the measured lens rise merits for cosmetic. Lens Design tool was CODE V (Optical Research Associates). Results: -5.00D aspherical lens had somewhat high astigmatism and distortion compared with the spherical lens. But it had a merit for cosmetic because of short axial height and decrease edge thickness. Improved a performance of distortion and ascertain merits for cosmetic due to short axial height and decrease edge thickness same as (-) lens in case of +5.00 aspherical lens. Though an optimization process front surface aspherical lens had a good performance for astigmatism and distortion and the merit for beauty compared with measured spherical lens. Conclusions: Design trend for domestic aspherical lens is decrease axial height and thickness to increase a merit for cosmetic not but increase performance of aberration. From design theory for optimization design front surface aspherical spectacle lens which has improved performance of aberration and merit for cosmetic at the same time compared with the measured lens. Expect an improved performance from design back aspherical lens compared with front aspherical lens.

Presbyopic Spectacle and Monovision for Reading Performance Before Adaptation (노안안경과 모노비젼 콘택트렌즈 착용 후 적응 전 읽기 능력 평가)

  • Chu, Byoung Sun;Hwang, Jeong Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 2010
  • Purpose: Eye movements and fixation ability are an important procedure to obtain external information and essential means of clear vision. The purpose of this study was to determine the reading performance such as reading time and number of fixations when random text was viewed at varying distances. Methods: Twenty two presbyopes were participated. All subjects were screened for their suitability to participate in the study by clinical examination, and none of the participants had previously worn contact lenses and no previous experience of wearing any types of presbyopic vision correction except single vision. The reading time and number of fixations were recorded using eye tracker while each subjects was waring four vision corrections which included single vision for distance (SV), bifocal spectacle lenses (BIF), progressive addition lenses (PAL), and monovision (MV). The reading material was presented at distance and near distance. Results: Reading time and number of fixations for near stimulus were significantly different among vision correction used in this study (p<0.001). In particular, wearing SV required longer reading time and produced longer fixation duration for near text. However, reading distance text was similarity performed across vision corrections tested and there was no statistical difference found for either reading time and number of fixations. Conclusions: Wearing presbyopic vision correction is advantageous for reading task of near stimuli, but not having near correction such as wearing SV could result in longer reading time and higher number of fixation due to lacks of accommodative ability for near task. For the future studies, it would be interesting to examine the performance of reading both at adapted and unadapted stages as examining only unadapted wearers was limitation of this study.