• Title/Summary/Keyword: Spectacle Lens

Search Result 43, Processing Time 0.02 seconds

The Change of the Near Eye Position according to the Spectacle and Contact Lens Wearing (안경과 콘택트렌즈 착용에 따른 근거리안위의 변화)

  • Han, Sun-Hee;Kim, Bong-Hwan;Kim, Hak-Jun;Park, Jun-Sung;Park, Hae-Been;Kim, Mi-Jeong;Park, Ju-Hyeong;Kim, Jin-Sol;Lee, Kyeong-Hoon;Kim, Jong-Hwan;Ha, Na-Ri
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.4
    • /
    • pp.435-443
    • /
    • 2015
  • Purpose. This study was to investigate comparison of the near eye position according to the spectacle and contact lens wearing. Methods. We measured the AC/A ratio and near horizontal phoria using modified Thorington method in each case spectacle and contact lens wearing of equivalent spherical power after measuring the full corrected diopter for 20 subjects (men 5, woman 15, $21.15{\pm}1.35$ years) without specific ocular diseases, ocular surgery experience and vision anomalies. Results. It was shown high correlation between spectacle and contact lens wearing as AC/A ratio is a correlation coefficient 0.99 (p=0.00), near horizontal phoria is a correlation coefficient 0.95 (p=0.00). And contact lens wearing increased as AC/A ratio by $0.32{\pm}1.35$ ${\Delta}/D$ (p=0.31) and near horizontal phoria by $-0.17{\pm}2.18$ ${\Delta}$ (p=0.73) than spectacle wearing but there was no statistically significant difference. As the higher myopic grade AC/A ratio increased and then was shown decreased tendency in -6.00 D < $SED{\leq}-4.00$ D group (p>0.05) and as the higher myopic grade near exophoria increased but there was no statistically significant difference (p>0.05). Conclusions. We should consider that the subjects who had the lower AC/A ratio or higher near exophoria in -6.00 D < $SED{\leq}-4.00$ D group were necessary to measure AC/A ratio and near horizontal phoria when they were wearing contact lens because contact lens wearing tended to increase the near exophoria than spectacle wearing.

Comparison of Accommodative Response among Emmetropes, Spectacle and Contact Lens Wearer (정시, 안경 및 콘택트렌즈 착용자의 조절반응량 비교)

  • Lee, Kyu-Byung;Park, Jeehyun;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.403-410
    • /
    • 2012
  • Purpose: The purposes of this study are to investigate accommodative response among emmetropes, spectacle wearer and contact lens wearer, and correlation between refractive error and accommodative respons for each group. Methods: The 72 subjects(144 eyes) who do not have any ocular diseases were participate in this study. Subjects were categorized into emmetropes, spectacle wearer and contact lens wearer by refractive error using closed-field auto-refractometer. We measured dominant eye, naked/habitual visual acuity and refractive error of monocular/binocular vision of refractive error for far/near distance with open-field auto-refractometer and calculated accommodative lag. Results: There were no significant difference of accommodative lag between right and left eye dominant and non-dominant eye, monocular and binocular vision, and spectacle lens wearer and contact lens wearer, However the accommodative lag of binocular vision was severe than monocular vision at near. The lag of myopia was larger than emmetropes, and male was larger than female. Significant correlation was found between refractive error and accommodative lag in total subjects and the same result was found in emmetropes and contact lens wearer. However there were no significant correlation in the spectacle wearer. Conclusions: There were significant difference between emmetrops and myopes in terms of accommodative lag, however accommodative lag of spectacle wearer was not different with contact lens wearer in myopes. There were also significant correlation between refractive error and accommodative lag in emmetropes and contact lens wearer, but the accommodative lag of spectacle wearer was not significantly correlated with refractive error.

Fabrication of spectacle lens cutting materials (렌즈 절삭공구 재료의 제조)

  • Lee, Young-II
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.111-114
    • /
    • 2001
  • This paper presents the influence of the additive composition on flexural strength and hardness of SiC-TiC composites materials for spectacle lens cutting materials. The materials were hot-pressed at $1800^{\circ}C$ and subsequently annealed at $1910^{\circ}C$ for 3h. The heating rate was $15^{\circ}C/min$ and the cooling rate about $25^{\circ}C/min$ in from the sintering temperature to $1300^{\circ}C$. The growth of particles of spectacle lens cutting materials was analysed by SEM and crystalline phases were discussed by x-ray diffractometry. Typical fracture toughness and hardness of materials for spectacle lens cutting were $6.1MPa{\cdot}m^{1/2}$ and 14.9 GPa, respectively.

  • PDF

Convergence study of comparison of blue light blocking rate between colored lenses of various colors and dental tips (다양한 색상의 착색렌즈와 치과용 팁의 청광차단율 비교의 융합적 연구)

  • Lee, Sook-Jeong
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.7
    • /
    • pp.61-67
    • /
    • 2021
  • The purpose of this study was to investigate the colors of spectacle lenses that would be effective in blocking blue light among various colors so that the damage caused by blue light could be conveniently reduced even in daily life and when filling with dental light-curing resin. Each color dye of orange, brown, gray, yellow, red, and rosa was dissolved in an individual container of a spectacle lens tinting machine, and 6 uncolored spectacle lenses were immersed in a temperature of 90℃ for 1 hour to color. As a result of comparing the blue light transmittance of the colored spectacle lens and the tip for the photopolymerizer, the blue light transmittance of the orange colored lens was 0.82%, and the blue light blocking effssect was the best. Brown and gray tinted lenses had excellent blue light blocking rate, but it was difficult to recognize objects through the lens due to the high tinted concentration, and yellow tinted lenses were found to be effective when the tint was similar to the tip. The blue tinted lens had a blue light transmittance of 15.10%, which was lower than other tinted lenses. The results of the experimental study are expected to be helpful in recognizing the blue light transmittance by spectacle tinted lenses of various colors and making efforts to select the appropriate blue light blocking lens color and block harmful blue light stimuli.

Comparison of Contrast Sensitivity Between Soft Contact Lens Wearers and Spectacle Wearers (콘택트렌즈와 안경 착용자의 대비감도 비교)

  • Kim, Jai-Min;Lee, Min-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • The aim of the present study was to compare the contrast sensitivity of soft contact lens wearers, spectacle wearers or emmetropia. Seventy myopic eyes and thirty emmetropic eyes aged 19 to 26 years were collected. The myopic group included 48 eyes corrected with spectacle lenses and 22 eyes of them corrected with contact lenses, too: all had corrected vision acuity of 20/20 or better. Spatial contrast sensitivity was measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView  Functional Vision Analysis software at photopic or mesoopic condition. There was no significant difference in contrast sensitivity between spectacle lenses and emmetropes. Myopes corrected with soft contact lenses showed statistical sensitivity losses at 1.5, 12 cycle/degree spatial frequencies. In conclusion, our findings suggest that loss of contrast sensitivity in soft contact lens wearers might be interpreted as evidence for corneal disruption before corneal pathological events occur in contact lens wearers. Contrast sensitivity testing appears to be a useful method for evaluating soft contact lenses.

  • PDF

Effects of Stray Light in Blue-light Blocking Lens on the Quality of Image (청색광 차단렌즈에서 미광이 상의 질에 미치는 영향)

  • Yuk, Ju Sung;Yang, Seok-Jun;Kim, Yong Gwon;Choi, Eun Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.612-618
    • /
    • 2016
  • The aim of this study is to investigate the effects of stray light originating from the blue-light blocking lens on the quality of the image. After designing the ideal spectacle lens, anti-reflection spectacle lens without internal reflection, anti-reflection spectacle lens with internal reflection, and blue-light blocking lens with internal reflection, the light intensity distribution and stray light distribution were derived. The designed spectacle lenses are meniscus lenses with a refractive power of 0.00 D, refractive index of 1.56, and a radius of 155.15 mm. The peaks of reflectance of the 4 types of blue-light blocking lenses are in the range between 430 nm and 440 nm, and their reflectances are 5%, 10%, 15%, and 20%, respectively. According to the analysis results, as the reflectance of the blue-light blocking lens increases, the light intensity in the center of the lens decreases and the intensity of the stray light in the center-periphery and periphery of the lens increases. This trend appeared to intensify with increasing reflectance of the blue-light blocking lenses. Because the increase in the reflectance of the blue-light blocking lens degrades the quality of the image by increasing the intensity of the stray light in the center-periphery and periphery of the lens, its reflectance needs to be adjusted by varying the blue-light blocking ratio and the luminous transmittance, in order to diminish the level of visual discomfort.

Mechanical properties of materials for spectacle lens cutting(I) (안경렌즈 절삭용 재료의 기계적 특성(I))

  • Lee, Young-Il;Kim, Jin-Koo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.55-59
    • /
    • 2000
  • In this study, materials for spectacle lens cutting were fabricated by hot-pressing and annealing SiC powders with $Al_2O_3$ and $Y_2O_3$. A microstructure that consisted of uniformly distributed, large SiC grains and elongated SiC grains was developed by using ${\alpha}$-SiC powders. The microstructure was observed by scanning electron microscope(SEM). By hot-pressing and subsequent annealing, elongated ${\beta}$-SiC grains were grown via ${\beta}{\rightarrow}{\alpha}$ phase. This is caused the crack deflection as toughening mechanism. Typical hardness and fracture toughness of materials for spectacle lens cutting were 13.3 GPa and $4.8MPa{\cdot}m^{1/2}$, respectively.

  • PDF

Evaluation of Vision-Specific Quality of Life between Spectacles and Contact Lens Wearers (안경과 콘택트렌즈착용자의 삶의 질 평가)

  • Kang, Sue Ah;Kim, Jung Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.111-115
    • /
    • 2007
  • Purpose: The aim of this study was to assess vision-related quality of life and modes of refractive error correction. We administered NEI-VFQ (National Eye Institute Visual Function Questionnaire) to 137 subjects in two modes of refractive error correction: spectacles and contact lens wearers. The NEL-VFQ was developed to assess vision-related quality of life with respect to 1) visual symptoms 2) social function as well as difficulty with tasks and symptoms 3) economic issues and health concerns 4) psychological well-being. The NEL-VFQ was translated from English into Korean. Methods: All data were analyzed using SAS 8.0. Student's T-test was conducted to determine significant differences in each of the subscale (${\alpha}=0.05$). Result: The Peripheral Vision subscale score ($mean{\pm}SD$) was $52.2{\pm}32.7$ for the spectacle wearers, $88.6{\pm}18.1$ for contact lens wearers; the spectacle wearers' Peripheral Vision score was significantly lower than contact lens wearers (p=0.0001). There were also significant differences between two groups detected in Color Vision (p=0.001), General Vision (p=0.01) and Health Perception (p=0.01). Conclusion: Contact lens wearers and spectacle wearers were mostly high vision-related quality of life except General Vision and Health Perception. Especially, contact lens wearers were higher vision-related quality of life than spectacle wearers. Further studies on developing of good quality of contact lens will be needed to improve quality of life in ametropia.

  • PDF

Study on the Labeling Items and Reliability of Spectacle Lens (안경렌즈의 표시사항 및 신뢰성에 관한 연구)

  • Ye, Ki-Hun;Kim, Tae-Hun;Kwon, Young-Seok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.323-327
    • /
    • 2006
  • For this study we research investigated the current situation of packing on the labeling items of domestic spectacle lens and reliability of spectacle lens. We use sample which is three hundred and ninety six spectacle lenses of eight company total. Refractive index of each sample in experiment is 1.55~1.56, 1.60~1.61 and 1.67. The percentage of labeling of A company and B company indicated the percentage of labeling of 80%, but The percentage of labeling of two companies indicated only 52.1% and 56.9% seperately. The most companies indicated comparatively a low marking ratio about packing on the labeling items. The results of difference the value of power which is recorded with the value of power which is measurement showed only small value.

  • PDF

For Improvement in Quality of a Lens for Sight Revision (시력 보정용 렌즈의 품질 개선방향)

  • Joung, Maeng-Sig;Kim, Hong-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.167-179
    • /
    • 1998
  • Todays in the field of lens makers, the technology machinery equipment and investment is shrunken by many factors. But much more decisive investment is wanted to strengthen competitiveness. Most of all, the technology of management and quality examination is important in the confidence of lens. So external and internal examination must be accomplished scientifically not by macrography but by the microscope and the computer. As the hardness examination of glass in the automobile, that of spectacle lens must not be harmful to the human body. All the raw material of spectacle lens is being imported for the lack of technology. To overcome these circumstances. We must establish the research institute that can develop the technology and must train a technical expert.

  • PDF