• 제목/요약/키워드: Specimen type

검색결과 1,385건 처리시간 0.039초

원주형 콘크리트 공시체의 캡핑종류별 압축강도 영향 (An Experimental Study on the Effect of Capping Type of Cylindrical Concrete Specimen on Compressive Strength)

  • 이상완;김수만;백승종;김광돈;이평석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.167-172
    • /
    • 2000
  • There are a variety of factors affecting measured compressive strength of hardened concrete. One of them is the end surface condition of concrete specimen. So, many capping methods have been developed for the specimen to meet the end condition requirement of ASTM C 39. A series of experimental strength comparison study was carried out using several representative capping methods, including pad capping method which is one of unbonded elastomeric capping system and was newly adopted in the ASTM standard. A comparison was also focused on their economy, convenience, harmfulness, etc.

  • PDF

압송용 고압 고무관의 최적구조설계 (Optimization of high pressure rubber tube for force pump)

  • 최준영;강태호;김인관;김영수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.604-607
    • /
    • 2000
  • All of rubber tubes for force pump are imported from aboard there for locallization of these tubes is make a great contribution of Korean industry In this study compare with existing product of japan and designed the new one that is for our actual circumstances. Experimental work was performed to two kinds of specimen and compression test is performed for them. As a result specimen type A has a better restoration than other and minimum thickness is must over 12mm.

  • PDF

Stress Corrosion Cracking in the Pre-Cracked Specimens of Type 403 Stainless Steel

  • Kim, Jong Jip
    • Corrosion Science and Technology
    • /
    • 제3권1호
    • /
    • pp.14-19
    • /
    • 2004
  • Crack growth rate and threshold stress intensity factor for stress corrosion cracking(SCC), $K_{ISCC}$ were measured for type 403 stainless steel in 3,5% NaCl solution at room temperature and SCC was monitored by electrochemical noise technique during $K_{ISCC}$ testing. In rising load test, pits were formed at the tip of pre-crack for the pre-cracked compact tension specimen unlike in smooth round specimen in which only unstable pits were observed and hence immune to SCC. Micro-cracks were found to initiate from the pits in the former specimen, and initiation of micro-crack as well as macro-crack was detected by electrochemical noise technique in rising load $K_{ISCC}$ tests. Crack growth rate increased with increasing either displacement rate or stress intensity factor at crack initiation and was higher in rising load $K_{ISCC}$ test compared to constant load $K_{ISCC}$ test at given stress intensities.

고속충돌시험기 개발 및 부재의 충돌특성 실험에 관한 연구 (I) (A Study on the Development of Test Rig for High Speed Frontal Crash and Test of Members ($\textrm{I}$))

  • 강신유;장인배;김헌영;정규진;박경환
    • 한국정밀공학회지
    • /
    • 제17권6호
    • /
    • pp.119-126
    • /
    • 2000
  • In this paper. a simple high-speed crash test rig for members of vehicle was developed for the improvement of crashworthiness of vehicle's side rail. The cart hanging the specimen is accelerated up to 35 mph by the force of freely dropping weight and 1:3 accelerating pulleys. The cart with shock absorbers travels on the rail roads, so it does not transfer any additional vibration to the specimen. To measure the test results, two types of accelerator are considered. the one is a strain gage type and the other is a piezo type. The test rig is rated good to test the specimen like a side rail of vehicle as developing the vehicle's structures in the early design stage.

  • PDF

단면현상에 따른 벽식구조 전단벽의 구조성능 평가 (Structural Performance of Shearwall with Sectional Shape in Wall-type Apartment Buildings)

  • 한상환;오영훈;오창학;이리형
    • 콘크리트학회논문집
    • /
    • 제12권4호
    • /
    • pp.3-14
    • /
    • 2000
  • Structural performance of the walls subjected to lateral load reversals depends on various parameters such as loading history, sectional shape, reinforcement, lateral confinement, aspect ratio, axial compression, etc. Thus, the performance of the shearwall for wall-type apartment should be evaluated properly considering above parameters. This study investigates the effect of sectional shape on the structural performance of the wall. Sectional shape of the specimen is rectangular, barbell and T. Based on this experimental results, all specimens behaved as ductile fashion and failed by concrete crushing of the compression zone. Deformation index of those specimens evaluated better than 3 of ductility ratio, and 1.5% of deformability specified by seismic provision. Moreover, the performance of the rectangular shaped specimen, whose compression zone was confined with U-bar and cross tie, was as good as the barbell shaped specimen. Therefore, if we considered construction practice such as workmanship and detailing, shearwall with rectangular section may be more economical lateral load resisting system.

2024 Al 합금의 ECAP 공정에 따른 미세조직 변화와 강도특성 (Microstructures and Mechanical Behavior of 2024 Al Alloys Deformed by Equal Channel Angular Pressing)

  • 김선화;최용락
    • 한국재료학회지
    • /
    • 제16권1호
    • /
    • pp.68-74
    • /
    • 2006
  • 2024 Al alloys were severely deformed by equal channel angular pressing(ECAP) to obtain an ultrafine grain structure. The more deformation amount increased, the more grain size decreased. Most of the grain structure were changed from elongated to equiaxed shape with increasing pass number. The morphology of S' phases was also changed from rod-type to spherical type. The grain size of 6 passed specimen was 100 to 200 nm, and the size of S' phases was about 10 nm in the microstructure. XRD measurements have revealed that the texture formed by plastic deformation disappeared in the 6 passed specimen. SP test results described that the start of crack propagation occurred at the transition zone between plastic bending and membrane stretching because of small elongation. The maximum strength of ECA pressed specimen increased 1.9 GPa to 2.9 GPa with increasing pass number.

조직변화(組織變化)가 피로현상(疲勞現象)에 미치는 영향(影響) (The Effect of Structure on the Fatigue of Low Carbon Steel)

  • 강창수;서창민
    • 대한조선학회지
    • /
    • 제9권2호
    • /
    • pp.33-42
    • /
    • 1972
  • This paper was studied on the behavior, crack formation and propagation of slip bands on low carbon steel which was heat-treated in three conditions in order to change metallic structure. The specimens were tested by rotating bending fatigue testing machine and also observed the variations of grains by microscope. From the test results it was clear that fatigue endurance limit and life of low carbon steel were more increased in contrast with the case that the grain size of specimen was more decreased. Slip bands developed at oil-quenched specimen and furnace-cooled specimen. Formed cracks in the first one or two grains below the surface were approximately "planar" type, there after they followed "wavy" type. It was also found that cracks at 30% higher stress than fatigue limit were usually developed inter-granular, and cracks at 12% higher stress than fatigue limit were propagated meandering path, partly trans- and partly inter-grandular.

  • PDF

AE을 이용한 강의 피로균열전파 거동에 관한 연구 (A Study on Fatigue Crack Growth Behavior of Steel Using AE)

  • 정규연;김선진;김영식;오명석;김영대
    • 동력기계공학회지
    • /
    • 제5권2호
    • /
    • pp.50-56
    • /
    • 2001
  • In this study, the effect of specimen thickness and stress ratio on fatigue crack growth in S45C steel was investigated. Acoustic emission was monitored during the fatigue crack growth test. Both crack closure and AE technique were used in assessing fatigue crack growth behavior. Constant amplitude loading tests were performed on CT type specimen with three different thicknesses and stress ratios. Crack closure was investigated to explain the influence of specimen thickness and stress ratio on the fatigue crack growth in the second growth region. The crack closure effect was decreased with specimen thickness and stress ratio.

  • PDF

Effect of Specimen Thickness on the Statistical Properties of Fatigue Crack Growth Resistance in BS4360 Steel

  • Kim, Seon-Jin;Itagaki, Hiroshi;Ishizuka, Tetsuo
    • Journal of Mechanical Science and Technology
    • /
    • 제14권10호
    • /
    • pp.1041-1050
    • /
    • 2000
  • In this paper the effect of specimen thickness on fatigue crack growth with the spatial distribution of material properties is presented. Basically, the material resistance to fatigue crack growth is treated as a spatial stochastic process, which varies randomly on the crack surface. The theoretical autocorrelation functions of fatigue crack growth resistance with specimen thickness are discussed for several correlation lengths. Constant ${\Delta}K$ fatigue crack growth tests were also performed on CT type specimens with three different thicknesses of BS 4360 steel. Applying the proposed stochastic model and statistical analysis procedure, the experimental data were analyzed for different specimen thicknesses for determining the autocorrelation functions and probability distributions of the fatigue crack growth resistance.

  • PDF

동전위 분극저항 측정에서의 불확도 (Uncertainty in Potentiodynamic Polarization Resistance Measurement)

  • 김종집
    • Corrosion Science and Technology
    • /
    • 제8권5호
    • /
    • pp.193-196
    • /
    • 2009
  • For the estimation of uncertainty in potentiodynamic polarization resistance measurement, the type A uncertainty was measured using type 316 stainless steel in an acidified NaCl solution. Sensitivity coefficients were determined for measurand such as scan rate of potential, temperature of solution, concentration of NaCl, concentration of HCl, surface roughness of specimen and flow rate of purging gas. Sensitivity coefficients were large for the measurand such as the scan rate of potential, temperature of solution and roughness of specimen. However, the sensitivity coefficients were not the major factors influencing the combined standard uncertainty of polarization resistance due to the low values of uncertainty in measurements of the measurands. A major influencing factor was the concentration of NaCl. The value of type A uncertainty was 1.1 times the value of type B uncertainty, and the combined standard uncertainty was 10.5 % of the average value of polarization resistance.