• Title/Summary/Keyword: Specimen shape

Search Result 713, Processing Time 0.029 seconds

A Study on the Evaluation of Fracture Resistance Characteristics of Large Pipe by using the Curved CT Specimen (대형배관의 Curved CT 시편을 이용한 파괴저항특성평가에 관한 연구)

  • Kim, Ik Hyun;Shin, In Hwan;Park, Kweon Tae;Hong, Suk Woo;Park, Seon Soon;Yoon, Seon Hyun;Koo, Jae Mean;Seok, Chang Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.7
    • /
    • pp.623-626
    • /
    • 2014
  • The LBB (Leak Before Break) concept is based on evaluating the fracture toughness. NUREG 1061, Vol.3 announced that the specimen for evaluating fracture resistance needs to have same thickness or thicker than pipe. Therefore, it is difficult to collect specimen from pipe which has same thickness as a pipe. So, ASTM standard suggested the use of standard specimen with 1 inch thickness. However, it has been known that an application of LBB by test results of standard specimen is conservative compare with that by real pipe. In this study, to supplement such conservatism, the evaluation of fracture resistance characteristics was performed with curved CT specimen, which has same thickness and curvature as a pipe. In addition, fracture resistance characteristics of curved CT specimen were compared with those of CT specimen. For this, shape factor F, hpl and g were obtained from FEM analysis using the limit load method.

A study on microstructure, corrosion characteries and hardness of pure Ti according to cooling methods (생체용 순수 Ti 주조체의 냉각방법에 따른 주조조직과 부식특성 및 경도에 관한 연구)

  • Kim, Jae-Doo
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.65-73
    • /
    • 2001
  • The purpose of this study was to investigate the microstucture and hardness, corrosion of pure Ti alloy, which is widely used as partial denture frame work these days, depending on the cooling method, followed by casting. The first group was bench cooling at room temperature($18^{\circ}C$), the second group was slowly cooled in the furnace from $700^{\circ}C$ to room temperature, and third. rapidly cooled in $0^{\circ}C$ water. The microstructure of each specimen observed by means of photomicrograph taken by electron microscope, in add to the physical characteristics of each specimen were obtained using the rockwell Hardnest Number. the characteristics of corrosion. The results were obtained as follows: 1. From Potentiodynamic plot. we conclude furnace-cooled specimen had the best stabiltity of passive film and that air-cooled specimen showed similar characteristics. The density of electric current of quenched specimen was the highest, which formed kind of unstable passive film. 2. Specimen cooled at room temperature (air cooling) had the highest value of hardness of 81.26HRB, specimen cooled at ice-water, $0^{\circ}C$, had the value of 78.42HRB, and specimen furnace-cooled at $700^{\circ}C$ had lowest value of 77.1HRB. 3. Quenching treated micro-structure formed martensite structure by and large. In case of air cooling, we could see $\alpha$-structure widmanstatten formed overall. In furnace cooling, widmanstatten structure and various shape $\alpha$-structures forming colony with direction were detected.

  • PDF

Effects of Specimen Size and Testing Velocity on Puncture Properties of Short-fiber Reinforced Chloroprene Rubber (시편 크기 및 시험속도가 단섬유 강화 클로로프렌 고무의 관통 특성에 미치는 영향)

  • Ryu, Sang-Ryeoul;Lee, Dong-Joo
    • Composites Research
    • /
    • v.20 no.6
    • /
    • pp.28-33
    • /
    • 2007
  • The puncture properties of short-fiber reinforced rubber were investigated as functions of fiber aspect ratio(AR: length of fiber/diameter of fiber), fiber content, specimen size and testing velocity. The puncture stresses of the matrix and short-fiber reinforced rubber decreased with specimen size, and increased with testing velocity at same specimen size. As the fiber AR increased the puncture stress at given fiber content also increased. The problem of the specimen shape was investigated by the comparison of the tensile strength with puncture stress. The forces acting in the membrane wall of the matrix and the short-fiber reinforced rubber showed a similar data regardless of specimen size. And those increased with testing velocity at same specimen size. As the fiber AR increased the force acting in the wall at given fiber content also increased. Overall, it was found that the specimen size, testing velocity had an important effects on the puncture properties.

A Study on the Variations of Impact Strength of Plastics for Various Thicknesses and Notch Formation (두께와 노치생성방법에 따른 플라스틱 수지의 충격강도 변화에 관한 연구)

  • Kim, Hyun;Lee, Dae-Seop;Lim, Jae-Soo;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.36 no.1
    • /
    • pp.59-64
    • /
    • 2012
  • The impact strength of material is considered the most important design factor for small and light products. Impact strength is a unique material property, thus the impact strength should not depend upon the geometry of specimen. However it varies according to specimen thickness, notching method, and notch shape. In this study, the variations of impact strength have been investigated according to thickness, notch shape, and notching method of specimen. Engineering plastics such as PC, ABS and POM have been used in this study. Experimental results showed impact strength increased as thickness decreasesd. PC showed the highest increment of impact strength when the thickness was thin. Fractured section of PC showed brittle fracture behavior when the specimen was thick. However it showed ductile fracture behavior when it was thin. The impact strength of in-mold notched specimen showed higher than that of milling notched specimen. PC showed the highest notch sensitivity among the materials used in this experiment.

The Effect of Specimen Size on Liquid Segregation in Deformation Behavior of Mushy State Material (고액공존재료의 변형거동에서 재료의 크기가 액상편석에 미치는 영향)

  • 윤성원;서판기;강충길
    • Transactions of Materials Processing
    • /
    • v.12 no.2
    • /
    • pp.94-101
    • /
    • 2003
  • For the optimal net shape forging of S semi-solid materials (SSM), it is important to predict the deformation behavior and defects of materials. Among these defects, liquid segregation is detrimental to produce products with good mechanical properties. Moreover, to apply a numerical method to thixoforging, it is very important to prevent a liquid segregation during forming process. The liquid segregation phenomena in deformation behavior of semi-solid material with variation of test specimen size were studied. The SSM compression tests were performed by dynamic material test system with a furnace. Stress-strain curves and microstructures of SSM were investigated, and Porosities were analyzed to evaluate the effects of experiment parameters on liquid segregation.

The Weld Defects Expression Method by the Concept of Segment Splitting Method and Mean Distance (분할법과 평균거리 개념에 의한 용접 결함 표현 방법)

  • Lee, Jeong-Ick;Koh, Byung-Kab
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.37-43
    • /
    • 2007
  • In this paper, laser vision sensor is used to detect some defects any $co_{2}$ welded specimen in hardware. But, as the best expression of defects of welded specimen, the concept of segment splitting method and mean distance are introduced in software. The developed GUI software is used for deriding whether any welded specimen makes as proper shape or detects in real time. The criteria are based upon ISO 5817 as limits of imperfections in metallic fusion welds.

The Microstructure For Removing of Beadmark of Hardfacing Wrapping Roll (육성용접된 Wrapping Roll의 비드마크제거를 위한 미세조직)

  • 유국종;백응률
    • Proceedings of the KWS Conference
    • /
    • 2000.10a
    • /
    • pp.216-218
    • /
    • 2000
  • In case of hardfaced wrapping roll, beadmark shape appear at wrapping roll surface due to irregular wear between weld bead. Irregular wear of this is caused by difference of hardness between weld bead. This study aims at investigating which matrix is good for removing of beadmark at wrapping roll surface. So, we make specimen with martensitic matrix and austenitic matrix. The hardfacing alloys were deposited 4 times on a SS41 steel plate using self-shielding flux cored arc welding method. Difference of hardness between weld bead of specimen with matrix of martensite was higher than specimen with matrix of austenite both as-welded and after heat treatment. Therefore, austenitic matrix is better than martensitic matrix for removing of beadmark of wrapping roll surface.

  • PDF

Generalization and its Verification of Concrete Compressive Strength Prediction Equation (콘크리트 압축강도 예측식의 일반화 및 이들 식의 검증)

  • Choi, Joong-Cheol;Yi, Seong-Tae;Yang, Eun-Ik;Kim, Dong-Yong;Son, Suk-Ho;Mun, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.537-540
    • /
    • 2006
  • In previous study, the effect of specimen sizes and shapes on the compressive strength of concrete specimens was experimentally investigated based on fracture mechanics. In this study, the relationship between the cube compressive strength and the cylinder strength for representative specimen sizes was investigated by linear regression analyses. And, by reanalyzing the compressive strength prediction equations with specimen size and shape obtained in previous studies, the compressive strength prediction equations were generalized. In addition, its verification was investigated by comparing with the results obtained from other researchers.

  • PDF

Image Noise Reduction Using Structural Mode Shaping for Scanning Electron Microscopy

  • Hamochi, Mitsuru;Wakui, Shinji
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.28-33
    • /
    • 2008
  • In a scanning electron microscope (SEM), outside acoustic noise causes image noise that distorts observations of the specimen being examined. A SEM that is less sensitive to acoustic noise is highly desirable. This paper investigates the image noise problem by addressing the mode shapes of the base plate and the transmission path of the acoustic noise and vibration. By arranging the position of the rib, a new SEM base plate was developed that had twisting as the 1st and 2nd modes. In those two twisting modes, vibration nodes existed near the center of the base plate where the specimen chamber is placed. Less vibration was transmitted to the chamber and to the specimen by the twisting modes compared to bending ones, which are the 2nd and 3rd modes for a rectangular plain base plate. An SEM with the developed base plate installed exhibited a significant reduction of image noise when exposed to acoustic noises below 250 Hz.

Microstructures and Mechanical Behavior of 2024 Al Alloys Deformed by Equal Channel Angular Pressing (2024 Al 합금의 ECAP 공정에 따른 미세조직 변화와 강도특성)

  • Kim, Seon-Hwa;Choi, Yong-Lak
    • Korean Journal of Materials Research
    • /
    • v.16 no.1
    • /
    • pp.68-74
    • /
    • 2006
  • 2024 Al alloys were severely deformed by equal channel angular pressing(ECAP) to obtain an ultrafine grain structure. The more deformation amount increased, the more grain size decreased. Most of the grain structure were changed from elongated to equiaxed shape with increasing pass number. The morphology of S' phases was also changed from rod-type to spherical type. The grain size of 6 passed specimen was 100 to 200 nm, and the size of S' phases was about 10 nm in the microstructure. XRD measurements have revealed that the texture formed by plastic deformation disappeared in the 6 passed specimen. SP test results described that the start of crack propagation occurred at the transition zone between plastic bending and membrane stretching because of small elongation. The maximum strength of ECA pressed specimen increased 1.9 GPa to 2.9 GPa with increasing pass number.