• Title/Summary/Keyword: Specimen processing

Search Result 470, Processing Time 0.022 seconds

A Study on the Measurement of Crack Length of Pipe Specimen Using Image Processing (이미지 프로세싱을 이용한 실배관 시험편의 균열 길이 측정에 관한 연구)

  • Kang, Min-Sung;Koo, Jae-Mean;Seok, Chang-Sung;Huh, Yong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.7-11
    • /
    • 2010
  • Difficulties associated with full-scale pipe tests are rather obvious. That is, it is not only difficult to perform them but also very expensive and it requires lots of experience. And the process of the fracture test for the pipe specimen is very difficult and complicated. Because the pipe specimen, the test jig and the test equipment are very large and heavy, it requires lots of costs and times. In this study, to easily perform the fracture toughness test for a pipe specimen, load line displacement data was obtained using the image processing method.

Application of Image Processing on the Laser Welded Defects Estimation (레이저 용접물 결함 평가에 대한 화상처리의 이용)

  • Lee, Jeong-Ick;Koh, Byung-Kab
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.4
    • /
    • pp.22-28
    • /
    • 2007
  • The welded defects are usually called user's unsatisfaction for appearance and functional usage. For checking these defects effectively without time loss, setup of weldability estimation system is an important for detecting whole specimen quality. In this study, after catching a rawdata on welded specimen profiles and treating vision processing with these data, the qualitative defects are estimated from getting these information by laser vision camera at first. At the same time, the weldability estimation for whole specimen is produced. For user friendly, the weldability estimation results are shown each profiles, final reports and visual graphics method. So, user can easily determined weldability. By applying these system to welding fabrication, these technologies are contribution to on-line setup of weldability estimation system.

Fabrication of Mechanical Fatigue Flawed Specimen with Notch Processing (노치가공법에 의한 기계적 피로결함 시험편 제조)

  • Hong, Jae-Geun;Park, Ban-Uk
    • 연구논문집
    • /
    • s.32
    • /
    • pp.55-64
    • /
    • 2002
  • Performance demonstration with real flawed specimens has been strongly required for nondestructive evaluation of safety class components in nuclear power plant. Specimen has been designed to produce mechanical fatigue flaw with tension stress and fatigue flaw has been produced to control stress and cycle, for suitable roughness. Notch condition is considered for control of fracture mode. After seal welding for fracture surface, final welding was performed to complete flaw specimen with GTAW(Gas Tungsten Arc welding) and FCAW(Flux Cored Arc Welding). It was demonstrated flaw size of flawed specimen by radiographic. testing and ultrasonic testing.

  • PDF

A Study on the Method of Transferring Metal Specimens for Real-time Transmission Electron Microscopy using Ultrasonic Treatment (초음파 처리 활용 실시간 투과전자현미경 관찰용 금속 시편 전사 방법에 관한 연구)

  • H. Kim
    • Transactions of Materials Processing
    • /
    • v.33 no.2
    • /
    • pp.118-122
    • /
    • 2024
  • Micro-electromechanical systems (MEMS) based in-situ heating holders have been developed to enable high resolution imaging of heat treatment analysis. However, unlike the standard 3 mm metal disk specimens used in the furnace-based heating holder and general transmission electron microscopy holder, the MEMS-based in-situ heating holder requires thin specimens that can be penetrated by electrons to be transferred onto the MEMS chip. Previously, focused ion beam milling was used to transfer metal specimens, but it has the disadvantage of being expensive and the risk of specimen damage due to gallium ions. Therefore, in this study, we devised a method of transferring metallic materials by ultrasonic treatment using a transmission electron microscopy specimen made by electro jet polishing. A 3mm electropolished metal disk was placed in an appropriate solution, ultrasonicated, and then drop casted. The transfer of the specimen was successful, but it was confirmed that dislocations were formed inside the specimen due to ultrasonic treatment. This study provides a novel method for transferring metallic materials onto MEMS chips, which is cost-effective and less gallium ion damaging to the specimen. The results of this study can be used to improve the efficiency of heat treatment analysis using MEMS-based in-situ heating holders.

The Area Measurement of Composite Specimen using Digital Image Processing (디지털 영상처리를 이용한 복합재료 시편의 면적 측정)

  • Son, Byung Jik;Lee, Kyu Hwan
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.17-22
    • /
    • 2015
  • In this paper, we study the calculation for the fracture area of the composite material specimens using digital image processing techniques. This study was able to calculate the area of the fracture region through the main operation step 7 on the basis of improved image. To extract the area in the original image, we have to use opening operation, close operation, the Hit-or-Miss operation and Bottom hat filter, Top hat filter, etc. In particular, to extract the area of the composite specimen discussed in this study, we have to use the combination of the operations and filters because it is non-isotropic material, or should develop a new algorithm based on it.

Electron Microscopic Study on Fine Needle Aspiration Cytology of Metastatic Malignant Melanoma (세침흡인 검체의 전자현미경 검색으로 진단된 전이성 악성 흑색종 1예)

  • Lee, Dong-Wha;Jin, So-Young;Kwon, Kye-Hyun
    • The Korean Journal of Cytopathology
    • /
    • v.3 no.2
    • /
    • pp.82-89
    • /
    • 1992
  • Electron microscopy (EM) can provide a valuable contribution to light microscopy (LM) In the Interpretation of fine needle aspiration cytology (FNAC) specimen, especially in the diagnosis of the tumor. However, considerable care in processing the specimen is mandatory to recover the cells and avoid altering the fine structures. We experienced a case of malignant melanoma in 33-yrs-old female, diagnosed by EM study of FNAC specimen from the axillary mass, who was initially thought as disseminated carcinomatosis on LM study. The technique of EM study on FNAC specimen consisted of washing the needle and syringe in 2.5% glutaraldehyde after a rapid stain (Diff-Quik), which was used to obtain a preliminary diagnostic impression and to assure the adequacy of the EM specimen. After centrifugation in the steps of fixation and dehydration, the sediment was made into an epon block and examined. The whole processing time of EM study can be shortened within 7 or 8 hours, and results can be available within 48 to 72 hours. Our experience suggests the EM study on FNAC can be a useful diagnostic method in the diagnosis of difficult FNAC cases.

  • PDF

Microstructure, Hardness and Tensile Properties of 600 MPa-Grade High-Strength and Seismic Resistant Reinforcing Steels (600 MPa급 고강도 일반 및 내진 철근의 미세조직, 경도와 인장 특성)

  • Seo, Ha-Neul;Lee, Sang-In;Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • v.27 no.9
    • /
    • pp.477-483
    • /
    • 2017
  • This present study deals with the microstructure and tensile properties of 600 MPa-grade high strength and seismic resistant reinforcing steels. The high strength reinforcing steel (SD 600) was fabricated by Tempcore processing, while the seismic resistant reinforcing steel (SD 600S) was air-cooled after hot-rolling treatment. The microstructure analysis results showed that the SD 600 steel specimen consisted of a tempered martensite and ferrite-pearlite structure after Tempcore processing, while the SD 600S steel specimen had a fully ferrite-pearlite structure. The room-temperature tensile test results indicate that, because of the enhanced solid solution and precipitation strengthening caused by relatively higher contents of C, Mn, Si and V in the SD 600S steel specimen, this specimen, with fully ferrite-pearlite structure, had yield and tensile strengths higher than those of the SD 600 specimen. On the other hand, the hardness of the SD 600 and SD 600S steel specimens changed in different ways according to location, dependent on the microstructure, ferrite grain size, and volume fraction.

Observation of thermal properties of dental 3D printer materials (치과용 DLP 3D Printer 가공체의 열특성 관찰)

  • Song, Joon-Boo;Park, Yu-Jin;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.71-76
    • /
    • 2021
  • Purpose: In this study, thermal properties were observed by measuring the extent of thermal expansion and the amount of thermal residue that appears upon burnout on a workpiece made by using a dental digital light processing (DLP) three-dimensional (3D) printer. Methods: Thermal properties of workpieces manufactured by using two 3D printers were observed. The specimens were designed in cylindrical form with dimensions 10 mm in diameter and 10 mm in height. The control specimen was made of wax, and the experimental specimen was made of resin. The thermal expansion rate was measured by applying heat to three types of specimens, and burnout residue was measured. Results: The thermal expansion rate of the wax pattern (WP) specimen was 0.93%±0.05%, of the RP1 specimen was 1.30%±0.08%, and of the RP2 specimen was 1.20%±0.09%. Measuring the recovered residue yielded residual amounts of 0.2% for the WP specimen, 1.1% for the RP2 specimen, and 1.8% for the RP1 specimen. Conclusion: 1. From measurements of the workpieces manufactured by dental DLP 3D printing, the thermal expansion rate was found to be higher than that of wax. 2. As a result of measuring burnout residues on the workpieces manufactured by dental DLP 3D printing, the required summoning temperature to obtain suitable castings was determined to >750℃.

Validation Study on Processing Grip Part of Tensile Specimen Acquired from Corroded Pipeline (부식이 존재하는 기존 노후 관로에서 인장 시편 가공 시 그립 가공 타당성에 대한 연구)

  • Nam, Young Jun;Kim, Jeong Hyun;Bae, Cheol Ho;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.191-195
    • /
    • 2020
  • In this work, tensile tests, one of the most common test method to assess the condition of a corroded pipe, were conducted. According to ASTM E8 method, the use of flat or curved uni-axial tension test is allowed under the recommendation with the usage of grips corresponding to a curvature of the pipe. However, this method is not for corroded specimen. Furthermore, in the case of performing the multiple tensile tests with various curvatures, it is desirable not to produce zigs that fit each curvatures, if merely processing the specimen grip with curvature into the flat grip can show almost identical tensile behavior. Therefore, various tension simulations were conducted first to check if there exist any differences. Also, experiments on corroded tensile specimen were conducted and compared with the FEM simulation that reflects the actual geometry acquired from the 3D scanner.

A Study on Weldability Estirmtion of Laser Welded Specimens by Vision Sensor (비전 센서를 이용한 레이져 용접물의 용접성 평가에 관한 연구)

  • 엄기원;이세헌;이정익
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1101-1104
    • /
    • 1995
  • Through welding fabrication, user can feel an surficaial and capable unsatisfaction because of welded defects, Generally speaking, these are called weld defects. For checking these defects effectively without time loss effectively, weldability estimation system setup isan urgent thing for detecting whole specimen quality. In this study, by laser vision camera, catching a rawdata on welded specimen profiles, treating vision processing with these data, qualititative defects are estimated from getting these information at first. At the same time, for detecting quantitative defects, whole specimen weldability estimation is pursued by multifeature pattern recognition, which is a kind of fuzzy pattern recognition. For user friendly, by weldability estimation results are shown each profiles, final reports and visual graphics method, user can easily determined weldability. By applying these system to welding fabrication, these technologies are contribution to on-line weldability estimation.

  • PDF