• 제목/요약/키워드: Specimen Changes

검색결과 548건 처리시간 0.035초

Influence of specimen height on the shear behavior of glass beads in the direct shear test

  • Young-Ho Hong;Yong-Hoon Byun;Jong-Sub Lee
    • Geomechanics and Engineering
    • /
    • 제34권4호
    • /
    • pp.461-472
    • /
    • 2023
  • A box scale affects the shear behavior of soils in the direct shear test. The purpose of this study is to investigate the scale effect on the shear behavior of dilative granular materials by testing specimens of different heights placed in a type C shear box. Experimental tests were performed on specimens composed of glass beads with different heights and equal initial void ratios. Results showed that the peak friction and dilation angles linearly increased with the specimen height; however, the residual friction angle remained relatively constant. Similarly, the shear stiffness increased with the specimen height, rapidly reaching its peak state. Height does not have a significant effect on the total volume changes; nevertheless, a high aspect ratio can be assumed to result in global and homogeneous failure. The results and interpretations may be used as reference for recommending shear box scale in direct shear tests.

초음파 검사법을 이용한 STS304 배관재 내부 균열 측정 방법에 대한 연구 (A study on the detection method of inner's crack of STS304 pipe using Ultrasonic Testing)

  • 황웅기;이경민;우영관;서덕희;이보영
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.415-418
    • /
    • 2011
  • Thermal fatigue is one of the life-limiting damage mechanisms in the nuclear power plant conditions. The turbulent mixing of fluids of different temperatures induces rapid temperature changes to the pipe wall. The successive thermal transients cause varying cyclic thermal stresses. These cyclic thermal stresses cause fatigue crack nucleation and growth similar to the cyclic mechanical stresses. The aim of this study was to fulfil the need by developing an real crack manufacturing method, which would produce realistic cracks. The test material was austenitic STS 304, which is used as pipelines in the reactor coolant system of a nuclear power plants. In order to fabricate thermal fatigue crack similar to realistic crack, successive thermal transients were applied to the specimen. Thermal transient cycles were combined with heating (60sec) and cooling cycle (30sec). And, In order to identify ultrasonic characteristic, it was performed the ultrasonic reflection measuring method for the fabricated specimen. From the results of ultrasonic reflection measuring testing, it was conformed that A-scan results(average 83% of real crack depth) for the TFC reference specimen was more enhanced NDT reliability than results(average 38% of real crack depth) for the EDM notch reference specimen.

  • PDF

과공정 Al-Si합금의 열팽창거동과 기계적 성질에 미치는 미세조직의 영향 (Effects of Microstructure on the Thermal Expansion Behavior and Mechanical Properties of the Hypereutectic Al-Si Alloy)

  • 박종성;이정근;김명호
    • 한국주조공학회지
    • /
    • 제17권4호
    • /
    • pp.365-370
    • /
    • 1997
  • The effects of changes in microstructure of Si phase on the thermal expansion coefficients(CTEs) and tensile properties of the hypereutectic Al-Si foundry alloy(A390) were investigated experimentally. Specimens were prepared by various fabrication processes, such as a permanent mold casting, a squeeze casting and a spray casting process, and subsequently hot-extruded. CTEs of the spray-cast specimen were found to be about 10% lower than those of the permanent mold-cast specimen, and the CTEs of the hypereutectic Al-Si alloy(A390) were changed proportionally with the size of Si phase. Ultimate tensile strength of the spray-cast and hot-extruded specimen was dramatically improved about 100% with improved elongation, compared to that of permanent mold-cast specimen. These improvements are mainly attributed to the reduction in size and aspect ratio of the brittle Si phase, and the elimination of the microvoids/porosities formed during casting.

  • PDF

Time dependent numerical simulation of MFL coil sensor for metal damage detection

  • Azad, Ali;Lee, Jong-Jae;Kim, Namgyu
    • Smart Structures and Systems
    • /
    • 제28권6호
    • /
    • pp.727-735
    • /
    • 2021
  • Recently, non-destructive health monitoring methods such as magnetic flux leakage (MFL) method, have become popular due to their advantages over destructive methods. Currently, numerical study on this field has been limited to simplified studies by only obtaining MFL instead of induced voltage inside coil sensor. In this study, it was proposed to perform a novel numerical simulation of MFL's coil sensor by considering vital parameters including specimen's motion with constant velocity and saturation status of specimen in time domain. A steel-rod specimen with two stepwise cross-sectional changes (i.e., 21% and 16%) was fabricated using low carbon steel. In order to evaluate the results of numerical simulation, an experimental test was also conducted using a magnetic probe, with same size specimen and test parameters, exclusively. According to comparative results of numerical simulation and experimental test, similar signal amplitude and signal pattern were observed. Thus, proposed numerical simulation method can be used as a reliable source to check efficiency of sensor probe when different size specimens with different defects should be inspected.

액체금속(GaInSn)윤활하에서 DLC(ta-C) 코팅된 레이저 표면 텍스쳐링 딤플패턴의 미끄럼 마찰특성평가 (Evaluation of Sliding Friction Properties of Laser Surface Texturing Dimple Pattern with DLC Coating under GaInSn Liquid Metal Lubricant)

  • 권규빈;장영준;채영훈
    • Tribology and Lubricants
    • /
    • 제37권3호
    • /
    • pp.106-111
    • /
    • 2021
  • There are several studies on reducing the friction that occurs on the relative sliding contact surface of moving parts under extreme environments. In particular, a solid lubricated bearing is studied to solve the tribological problem with friction reduction and durability parts using solid lubricants (lead or silver) in a vacuum atmosphere. Galinstan is mainly used as a liquid metal lubricant, but it is inevitable to have limited tribological applications owing to its high coefficient of friction. Many researchers work on surface texturing for surface modification and precision processing methods. To increase durability and low friction, DLC coating with hydrophobicity is applied on the contact surface texture. Therefore, using an untextured specimen, a dimple specimen, and a DLC-coated dimple specimen under liquid metal lubrication, this paper presents the following experimental sliding friction characteristics in the sliding friction test. 1) The average coefficient of friction of the DLC-coated dimple specimen and dimple specimen are lower compared to that of a non-patterned specimen. 2) In the DLC-coated dimple specimens, the average coefficient of friction changes according to the change in the dimple density. 3) DLC-coated dimple specimens with a density of 12.5 have the lowest average coefficient of friction under 41.6 N of normal load and 143.3 RPM.

오스테나이타이징 온도와 냉각 속도가 SCM415 저탄소강의 미세조직과 경도에 미치는 영향 (Effect of Austenitizing Temperature and Cooling Rate on Microstructure and Hardness of Low-carbon SCM415 Steel)

  • 이종언;이교명;차재원;박성혁
    • 소성∙가공
    • /
    • 제31권4호
    • /
    • pp.207-213
    • /
    • 2022
  • In this study, variations in the microstructure and hardness of a low-carbon SCM415 steel with austenitizing temperature and cooling rate are investigated. When the austenitizing temperature is lower than the A1 temperature (738.8 ℃) of the SCM415 steel, the microstructures of both the air-cooled and water-cooled specimens consist of ferrite and pearlite, which are similar to the microstructure of the initial specimen. When heat treatment is conducted at temperatures ranging from the A1 temperature to the A3 temperature (822.4 ℃), the microstructure of the specimen changes depending on the temperature and cooling rate. The specimens air- and water-cooled from 750 ℃ consist of ferrite and pearlite, whereas the specimen water-cooled from 800 ℃ consists of ferrite and martensite. At a temperature higher than the A3 temperature, the air-cooled specimens consist of ferrite and pearlite, whereas the water-cooled specimens consist of martensite. At 650 ℃ and 700 ℃, which are lower than the A1 temperature, the hardness decreases irrespective of the cooling rate due to the ferrite coarsening and pearlite spheroidization. At 750 ℃ or higher, the air-cooled specimens have smaller grain sizes than the initial specimen, but they have lower hardness than the initial specimen owing to the increased interlamellar spacing of pearlite. At 800 ℃ or higher, martensitic transformation occurs during water cooling, which results in a significant increase in hardness. The specimens water-cooled from 850 ℃ and 950 ℃ have a complete martensite structure, and the specimen water-cooled from 850 ℃ has a higher hardness than that water-cooled from 950 ℃ because of the smaller size of prior austenite grains.

치과용 바렐연마의 시간에 따른 가공도 및 연마도 관찰 (Observation of machining and polishing according to the dental barrel polishing time)

  • 고현정;최성민
    • 대한치과기공학회지
    • /
    • 제45권4호
    • /
    • pp.87-94
    • /
    • 2023
  • Purpose: This study aimed to observed changes in the shape of dental barrels based on application time. Machinability measures the angle of alloy specimens. Polishing performance measures the surface roughness of alloy specimens. Methods: The dental barrel polishing equipment used in this study was a Snow Barrel (DK Mungyo). Three types of cobalt-chromium alloys for partial dentures were used as specimens (BC CAST R [BP]; Bukwang, Vera PDI [VP]; Aalbadent, and GM 800+ [GP]; Dentaurum). Specimens were prepared in the form of plates (10 mmx10 mmx2 mm). Dental barrel polishing was performed at 450 rpm for 60 minutes with intervals of 5 minutes. The processing angle was measured using a microscope (SZ61; Olympus). Results: For the angle measurement, the VPC specimen was measured at 78.64°, 36.00° for the VP60 specimen, 79.57° for the BP control (BPC) specimen, 28.07° for the BP60 specimen, 75.01° for the GPC specimen, and 39.92° for the GP60 specimen. For the surface roughness measurements, the average surface roughness of the VPC and VP15 specimens were 1.09 ㎛ and 0.26 ㎛, respectively. The average surface roughness of the BPC and BP20 specimens were 1.77 ㎛ and 0.29 ㎛, respectively. The average surface roughness of the GPC and GP15 specimens were 1.08 ㎛ and 0.27 ㎛. Conclusion: The results were excellent after about 20 minutes of dental barrel polishing conditions presented in this study.

불화물 도포 전 치면연마 시행여부에 따른 우식예방효과 (The preventive effect of fluoride materials on the dental caries by dental polishing prior to fluoride application)

  • 조민정;하명옥;오한나
    • 한국치위생학회지
    • /
    • 제12권1호
    • /
    • pp.113-122
    • /
    • 2012
  • Objectives : This study was carried out to investigate the caries resistant effect of fluoride by dental polishing prior to fluoride application in vitro. Methods : Artificial caries lesion was made on the surface of specimen enamel taken from cow's permanent cuspid on the part of labial surface after resin embedding and polishing. Artificial dental plaque was formed on the 72 dental specimen 25~45 VHN(Vickers Hardness Number) which were divided into three groups(fluoride varnish, APF gel, control) with dental polishing and without polishing respectively. Fluoride varnish and APF gel group with 20 second polishing or without polishing were immersed in the artificial saliva respectively. Control group with or without polishing were immersed in the artificial saliva. Results : 1. Significant difference was not found by fluoride varnish between polishing group and non polishing group (p>0.01). 1) polishing group. The changes of Vickers Hardness Number(VHN) were $14.49{\pm}13.73$. 2) non-polishing group. The changes of VHN were $11.67{\pm}5.39$. 2. Significant difference was not found by APF gel between polishing group and non polishing group (p>0.01). 1) polishing group. The changes of VHN were $8.48{\pm}8.37$. 2) non-polishing group. The changes of VHN were $5.32{\pm}2.59$. Conclusions : Showed no significant difference between polishing group and non-polishing group regardless of fluoride materials (fluoride varnish, APF gel).

Comparison of Dynamic Sorption and Hygroexpansion of Wood by Different Cyclic Hygrothermal Changing Effects

  • Yang, Tiantian;Ma, Erni
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권2호
    • /
    • pp.191-203
    • /
    • 2016
  • To investigate the dynamic sorptive and hygroexpansive behaviors of wood by different cyclic hygrothermal changing effects, poplar (populus euramericana Cv.) specimens, were exposed to dynamic sorption processes where relative humidity (RH) and temperature changed simultaneously in sinusoidal waves at 75-45% and $5-35^{\circ}C$ (condition A) and where RH changed sinusoidally at 75-45% but temperature was controlled at $20^{\circ}C$ (condition B), both for three cyclic periods of 1, 6, and 24 h. Moisture and dimensional changes measured during the cycling gave the following results: Moisture and transverse dimensional changes were generally sinusoidal. Moisture and dimensional amplitude increased with increasing cyclic period but all were lower for thicker specimens. The amplitude ratio of condition A to condition B ranged from 1.0 to 1.6 with the maximum value of 1.57 occurring at the shortest cyclic period, not as much as expected. T/R increased as cyclic period increased or specimen thickness decreased. T/R from condition B was weaker than that from condition A. Sorption and swelling hysteresis existed in both conditions. Sorption hysteresis was negatively related to cyclic period but in positive correlation with specimen thickness. Sorption hysteresis was found more obvious in condition B, while moisture sorption coefficient and humidity expansion coefficient showed the opposite results.

AZ91 마그네슘 합금의 PEO 피막 형성거동에 미치는 HF전처리의 영향 (Effect of pre-treatment of AZ91 Mg alloy in HF solution on PEO film formation behavior)

  • 권두영;송풍근;문성모
    • 한국표면공학회지
    • /
    • 제54권4호
    • /
    • pp.184-193
    • /
    • 2021
  • This study demonstrates formation behavior and morphological changes of PEO (Plasma Electrolytic Oxidation) films on AZ91 Mg alloy as a function of pre-treatment time in 1 M HF solution at 25 ± 1 ℃. The electrochemical behavior and morphological changes of AZ91 Mg alloy in the pre-treatment solution were also investigated with pre-treatment time. The PEO films were formed on the pre-treated AZ91 Mg alloy specimen by the application of anodic current 100 mA/cm2 of 300 Hz AC in 0.1 M NaOH + 0.4 M Na2SiO3 solution. Vigorous generation of hydrogen bubbles were observed upon immersion in the pre-treatment solution and its generation rate decreased with immersion time. It was also found that 𝛽-Mg17Al12 in AZ91 Mg alloy was dissolved and a protective thin film of MgF2 was formed on the AZ91 Mg alloy surface during the pre-treatment process in the 1 M HF solution. PEO film did not grow on the AZ91 Mg alloy specimen when the surface was not pre-treated and irregular PEO films with nodular defects were formed for the specimens pre-treated up to 1 min. Uniform PEO films were formed when the AZ91 Mg alloy specimen was pre-treated more than 3 min. The growth rate of PEO films on AZ91 Mg alloy increased significantly with increasing pre-treatment time.