• 제목/요약/키워드: Specimen

검색결과 10,840건 처리시간 0.049초

Mechanical Properties of the Apple Flesh According to the Specimen Size

  • Kim, M.S.
    • Agricultural and Biosystems Engineering
    • /
    • 제1권1호
    • /
    • pp.43-48
    • /
    • 2000
  • Mechanical properties of the apple flesh were tested with compression test apparatus constructed by this study. The computer program was developed for measuring mechanical properties, and analyzing data obtained from the study. Compression tests on the apple flesh were performed at four levels of specimen diameter, three levels of specimen length, and at constant loading rate(25mm/min). Five replications were made at each treatment combination. Effect of specimen size on the mechanical properties of the apple flesh was investigated.

  • PDF

하중작용방식에 따른 점용접재의 피로거동 (A Study on the Fatigue Behavior of Spot Weld Specimen as Applied Load Pattern)

  • 송삼홍;양윤진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.485-488
    • /
    • 2000
  • In this study, the fatigue characteristic of spot weld specimen was studied by using the various specimen. The specimen types were tensile shear specimen welded one spot and two spot, and cross tension. The tensile tests and fatigue tests were executed to know the mechanical properties under static and fatigue load condition. In addition, the relationship was illustrated by finite element method.

  • PDF

노치가공법에 의한 기계적 피로결함 시험편 제조 (Fabrication of Mechanical Fatigue Flawed Specimen with Notch Processing)

  • 홍재근;박반욱
    • 연구논문집
    • /
    • 통권32호
    • /
    • pp.55-64
    • /
    • 2002
  • Performance demonstration with real flawed specimens has been strongly required for nondestructive evaluation of safety class components in nuclear power plant. Specimen has been designed to produce mechanical fatigue flaw with tension stress and fatigue flaw has been produced to control stress and cycle, for suitable roughness. Notch condition is considered for control of fracture mode. After seal welding for fracture surface, final welding was performed to complete flaw specimen with GTAW(Gas Tungsten Arc welding) and FCAW(Flux Cored Arc Welding). It was demonstrated flaw size of flawed specimen by radiographic. testing and ultrasonic testing.

  • PDF

목재(木材)의 치수변동(変動)에 관(關)한 연구(硏究) (Study on Movement of Wood)

  • 정희석;이필우;이남호
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권2호
    • /
    • pp.36-42
    • /
    • 1986
  • Both the control and heated specimen of oak, hornbean, alder, poplar, red pine and pitch pine among domestic commercial species and taun imported were used for radial and tangential shrinkage and movement that occurred on changing the relative humidity of the atmosphere from 90 percent to 60 percent at $25^{\circ}C$. The results of this study were as follows. 1. The radial and tangential shrinkage of the control and heated hornbean and oak wood, except alder, of high specific gravity showed greater than species with low specific gravity. The ratio of tangential to radial shrinkage was 1.46 for taun to 2.70 for alder. Green volume specific gravity of the heated and soaked specimen of all species except poplar decreased 1.5 to 3.1 percent. Shrinkage of the heated specimen increased more than that of the control specimen, and antishrink efficiency of all timbers except alder had negative value. Shrinkage from green to air dry of treated specimens increased more than case of total shrinkage, and radial shrinkage of those specimen increased greater than tangential shrinkage. 3. The movement of the heating specimen for 120 hours decreased than those of the control and the heating specimen for 240 hours. The movement of heating oak, poplar, red pine and pitch pine (or 240 hours increased rather than those of the control specimen.

  • PDF

두꺼운 일방향 탄소섬유-에폭시 적층판의 정적 압축 강도 연구 (Static Compressive Strength of Thick Unidirectional Carbon Fiber - Epoxy Laminate)

  • ;;공창덕
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.61-65
    • /
    • 2005
  • Existing test methods for thick-section specimens ( 4mm) have not provided precise compressive properties to date for the analysis and design of thick structure. A survey of the failure behaviour of such thick specimens revealed that the failure initiated at the top corner of the specimen and propagated down and across the width of the specimen as premature failure, not typically reported for thin compression specimens. In the current study, the premature failure was successfully avoided during compressive testing and the failure mode was quite similar regardless of increasing specimen thickness and specimen volume. Failure mode was similar regardless of increasing specimen thickness and specimen volume, i.e. brooming failure mode combined with longitudinal splitting, interlaminar cracking, fibre breakage and kinkband formation (fibre microbuckling). Nevertheless, average failure strengths of the specimens decreased with increasing specimen thicnkiness from 2mm to 8mm with the T800/924C system (36% strength reduction) and specimen volumes from scaling factor I to scaling factor 4 with the IM7/8552 system (46% strength reduction). It was revealed from the literature$^{11}$ that the thickness effect and scaling effect arc caused by manufacturing defects such as void content and fibre waviness.

  • PDF

발전소 고온부의 수명 평가를 위한 소형 시편용 크리프 시험기의 개발 (Development of Small-Specimen Creep Tester for Life Assessment of High Temperature Components of Power Plant)

  • 김효진;정용근;박종진
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2597-2602
    • /
    • 2000
  • The most effective means of evaluating remaining life is through the creep testing of samples removed from the component. But sampling of large specimen from in-service component is actually impossible. So, sampling device and small-specimen creep tester have been applied. Sampling device has been devised to extract mechanically small samples by hemispherical, diamond -coated cutter from the surface of turbine rotor bores and thick-walled pipes without subsequent weld repairs requiring post weld heat treatment. A method of manufacturing small creep specimen, 2min gage diameter and 10min gage length, using electron beam welding to attach grip section, has been proven. Small-specimen creep tester has been designed to control atmosphere to prevent stress increment by oxidation during experiment. To determine whether the small specimens successfully reproduce the behavior of large specimens, creep rupture tests for small and large specimens have been performed at identical conditions. Creep rupture times based on small specimens have closely agreed within 5% error compared with that of large specimen. The errors in rupture time have decreased at longer test period. This comparison validates the procedure for fabricating and testing on small specimen. This technique offers potential as an efficient method for remaining life assessment by direct sampling from in -service high temperature components.

압력용기 보강재의 용접 형태에 따른 피로균열성장 거동에 관한 연구 (A Study on the Fatigue Crack Growth Behaviour for the Welded Configuration in Pressure Vessel Stiffener)

  • 차용훈;김하식;성백섭
    • 한국안전학회지
    • /
    • 제16권3호
    • /
    • pp.1-6
    • /
    • 2001
  • The study is to investigate the influence on the fatigue crack growth behaviors for the welded configuration in pressure vessel stiffener. In order to perform this goal, the automatic welded specimens were prepared. The material is ASTM A516 grade 60 steel used in pressure vessel mainly. In skip welding of pad-on-plate, continuous fillet welding and PWHT specimen, fatigue crack is generally initiated at the starting and end old toe zone, and ruptured at the starting old toe zone. The fatigue life of pad-on-plate of the continuous fillet welding specimen is larger than that of pad-on-plate skip fillet welding specimen about 85% under low load, about 20% under high load and less than that of two-pad continuous fillet welding specimen about 85%. In da/dN-$\Delta$K curve under low load, skip fillet welding specimen of pad-on-plate showed retardation on the initial crack, and the fatigue crack growth rate at the low region of $\Delta$K greater specimen E($3.8 {\times} 10^{-6}mm/cycle$). And the fatigue life of welding specimen was smaller than that of PWHT specimen.

  • PDF

Experimental and analytical assessment of SRF and aramid composites in retrofitting RC columns

  • Dang, Hoang V.;Shin, Myoungsu;Han, Sang Whan;Lee, Kihak
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.797-815
    • /
    • 2014
  • This research aimed to investigate retrofitting methods for damaged RC columns with SRF (Super Reinforced with Flexibility) and aramid composites and their impacts on the seismic responses. In the first stage, two original (undamaged) column specimens, designed to have a flexural- or shear-controlled failure mechanism, were tested under quasi-static lateral cyclic and constant axial loads to failure. Afterwards, the damaged column specimens were retrofitted, utilizing SRF composites and aramid rods for the flexural-controlled specimen and only SRF composites for the shear-controlled specimen. In the second stage, the retrofitted column specimens were tested again under the same conditions as the first stage. The hysteretic responses such as strength, ductility and energy dissipation were discussed and compared to clarify the specific effects of each retrofitting material on the seismic performances. Generally, SRF composites contributed greatly to the ductility of the specimens, especially for the shear-controlled specimen before retrofitting, in which twice the deformation capacity was obtained in the retrofitted specimen. The shear-controlled specimen also experienced a flexural failure mechanism after retrofitting. In addition, aramid rods moderately fortified the specimen in terms of the maximum shear strength. The maximum strength of the aramid-retrofitted specimen was 12% higher than the specimen without aramid rods. In addition, an analytical modeling of the undamaged specimens was conducted using Response-2000 and Zeus Nonlinear in order to further validate the experimental results.

Effects of Grain Size on the Fatigue Properties in Cold-Expanded Austenitic HNSs

  • Shin, Jong-Ho;Kim, Young-Deak;Lee, Jong-Wook
    • Metals and materials international
    • /
    • 제24권6호
    • /
    • pp.1412-1421
    • /
    • 2018
  • Cold-expanded austenitic high nitrogen steel (HNS) was subjected to investigate the effects of grain size on the stress-controlled high cycle fatigue (HCF) as well as the strain-controlled low cycle fatigue (LCF) properties. The austenitic HNSs with two different grain sizes (160 and $292{\mu}m$) were fabricated by the different hot forging strain. The fine-grained (FG) specimen exhibited longer LCF life and higher HCF limit than those of the coarse-grained (CG) specimen. Fatigue crack growth testing showed that crack propagation rate in the FG specimen was the same as that in the CG specimen, implying that crack propagation rate did not affect the discrepancy of LCF life and HCF limit between two cold-expanded HNSs. Therefore, it was estimated that superior LCF and HCF properties in the FG specimen resulted from the retardation of the fatigue crack initiation as compared with the CG specimen. Transmission electron microscopy showed that the effective grain size including twin boundaries are much finer in the FG specimen than that in the CG specimen, which can give favorable contributions to strengthening.

중형견(犬) 치과 보철물 제작을 위한 소재의 기계적 강도 관찰 (Observation of Mechanical Strength of Materials for Dog Dental Prosthesis Production)

  • 박유진;최성민
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.93-100
    • /
    • 2019
  • Purpose: This study is making a dog dental prosthesis using digital dental technology. The mechanical strength of the prosthetic material was observed in terms of compressive strength and fracture pattern. Methods: The experiment was performed using dog mandibular molars. The teeth were scanned and modeled. The specimens were made of zirconia, PMMA and Ni-Cr. The specimens were subjected to a vertical compression test with an artificial cancellous bone in UTM tester. Vertical compressive strength and fracture behavior of specimen were observed. Results: The result of observing the compressive load between specimen and artificial bone were $184.8{\pm}5.7N$ in the zirconia specimen, $185.6{\pm}8.9N$ in the PMMA specimen, and $184.4{\pm}4.0N$ in the Ni-Cr alloy specimen. Compression marks of artificial bones were observed. The fracture strength of specimen was observed. The fracture strength of the zirconia specimen was an average of 1,381.4N. The fracture strength of the PMMA specimen was an average of 572.2N. Conclusion: The crown made of three kinds(zirconia, PMMA, Ni-Cr alloy) of materials has the strength to chew about the artificial bone. zirconia and PMMA have vertical compressive strength applicable to medium dog dental prosthetic materials.