• 제목/요약/키워드: Specimen

검색결과 10,863건 처리시간 0.045초

일방향 CFRP 복합재료의 핀 베어링강도에 관한 시험편 치수의 영향 (Effect of Specimen Geometries on the Pin Bearing Strength of Unidirectional CFRP Composites)

  • 전진탁;김재동;고성위
    • 수산해양기술연구
    • /
    • 제33권4호
    • /
    • pp.346-351
    • /
    • 1997
  • The pin bearing strength is one of the most important design parameters for mechanical joints composed of fiber reinforced composites. Thus the effect of the edge distance and the width of specimen on the pin-bearing strength of unidirectional CFRP composites were experimentally investigated in this paper. As results, the failure modes and the pin bearing strength of mechanical joints turned out to depend on the edge distance and also the width of specimen. The failure of specimen with low ratio of width to hole diameter was caused by the net tension from the hole boundary, on the other hand, the failure of specimen with low ratio of edge distance to hole diameter was caused by the shear-out. The bearing strength in case of the failure by shear-out was quite lower than that in case of failure by net tension.

  • PDF

알루미나 세라믹스의 동적피로거동 (Dynamic Fatigue Behavior of Alumina Ceramics)

  • 이홍림;이규형;박성은
    • 한국세라믹학회지
    • /
    • 제34권10호
    • /
    • pp.1053-1059
    • /
    • 1997
  • The dynamic fatigue behavior of alumina ceramics was observed at room temperature using four point bending system. The dynamic fatigue fracture strength and the dynamic fatigue lifetime were observed as a function of crosshead speed and the notch length. The notched specimen showed the smaller deviation in dynamic fatigue fracture strength than the unnotched specimen. The crack growth exponent n and the material constant A of the notched specimen could be represented as functions of the notch length. Fracture strength of the specimen calculated from the notch length, when the notch length was regarded as the crack size, was in good agreement with the measured 4 point bending strength. Fracture surface of the specimen showed the different fracture modes according to the crosshead speed. The four point flexural strength, fracture toughness, Young's modulus and Weibull modulus of the alumina were measured as 360 MPa, 3.91 MPa.m1/2, 159GPa, 17.64, respectively.

  • PDF

부재의 길이가 콘크리트의 휨압축강도에 미치는 영향 (Effects of Specimen Length on Flexural Compressive Strength of Concrete)

  • 김진근;이성태;이태규
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.63-71
    • /
    • 1999
  • In evaluating the ultimate strength of a section for a reinforced concrete flexural member, the effect of member length is not usually considered, even though the strength tends to decrease with increase of member length. In this paper the influence of specimen length on flexural compressive strength of concrete was evaluated. For this purpose, a series of C-shaped specimens subjected to axial compression and bending moment were tested using four different length-to-depth ratios (from 1,2,3 and 4) of specimens with compressive strength of 590 kgf/$\textrm{cm}^2$. Results indicate that for the region of h/c <3.0 the reduction in flexural compressive strength with increase of length-to-depth ratios was apparent. A model equation was depth of an equivalent rectangular stress block was larger than that by ACI. It was also founded that the effect of specimen length on ultimate strain was negligible. Finally more general model equation is also suggested.

정지토압계수의 측정장치 개발에 관한 연구 (A Study on the Development of Measuring Equipment for Coefficient of Earth Pressure at Rest)

  • 송무효
    • 한국해양공학회지
    • /
    • 제13권2호통권32호
    • /
    • pp.159-167
    • /
    • 1999
  • For exisiting $K_0$-oedometer, the lateral wall of the ring is cut thinly to make space and by filling the space with space with water or mercuty to keep the balance to the lateral pressure of a specimen, the pressure of the fluid is checked for the pressure of the specimen. But the devices to keep the balance to the lateral pressure of a specimen are complicated, difficult to manufacture and expensive. As newly developed $K_0$-oedometer is equipped with the load cell which can resist higher pressute than the lateral pressure of the specimen, there is nearly no deformation due to the lateral pressure of the specimen. And the measuting is cheap and easy as there are fewer accessories.

  • PDF

RFID를 기반으로 한 실험실 정보 시스템의 설계 및 구현 (Design and Implementation of Laboratory Information System based on RFID)

  • 송상하;장승진;김효민;윤영로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.489-490
    • /
    • 2007
  • This paper is intended to trace and management of a medical specimen and its report in a hospital. To avoid missing and decaying specimen and to establish of order in the circulation of specimen, at the moment sampling, RFID tags for each are on examiner. And then, specimen is monitored easily, quickly and, correctly. We developed implementation LIS system has better CQI (Continuos Quality Improvement) using RFID and XML, ADO.net, ASP.net, C# 2.0. RFID technology replaces to an existing the bar-code system. Also for more convenience, we used a PDA-RFID module. The LIS system consists of main sorrel, SQL 2005, event display and analysis web page developed using asp.net 2.0 and sharing specimen data information using XML technology.

  • PDF

MEMS 소재의 기계적 특성 평가를 위한 인장형 시편 및 시험기 제작 (A Novel Tensile Specimen and Test Machine for Mechanical Properties of MEMS Materials)

  • 박준협;김정엽;이창승;좌성훈;송지호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.258-263
    • /
    • 2004
  • Mechanical property evaluation of micrometer-sized structures is necessary to help design reliable microelectromechanical systems(MEMS) devices. Most material properties are known to exhibit dependence on specimen size and such properties of microscale structures are not well characterized. This paper describes techniques developed for tensile testing of materials used in MEMS. Epi-polycrystalline silicon is currently the most widely used material, and its tensile strength has been measured as 1.52GPa. We have developed an uniaxial testing machine for testing microscale specimen using electro-magnetic actuator. The field magnet and the moving coil taken from an audio-speaker were utilized as the components of the actuator. Structure of specimen was designed and manufactured for easy handling and alignment. In addition to the static tensile tests, new techniques and procedures for measuring strength are described.

  • PDF

CRS 압밀시험의 해석과 적용에 관한 실험적 연구 (Experimental Study on Analysis and Application of CRS Test)

  • 이응준;한상재;김용수;김수삼
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.399-406
    • /
    • 2000
  • In this study, using the CRS consolidation tests on reconstituted marine clay, the characteristics of C$\sub$v/, k, e and $\varepsilon$, the anisotropic characteristics of specimen according to the rate of strain were estimated. Also, the validity of the Wissa et al.(1971) consolidation theory on CRS(Constant Rate of Strain) consolidation tests were reviewed. From that results, it was shown that the value of C$\sub$v/, k and u$\sub$b/ was increased as the rate of strain was increased. While the difference of the value( C$\sub$v/, k and u$\sub$b/) between vertically reconstituted specimen and horizontally reconstituted specimen became small as the rate of strain was increased. It is known that k is different due to the hydraulic gradient(i) during the CRS consolidation tests. The subject of this study is to distinguish steady state from transient state in CRS consolidation tests. Consequently, the difference of the value(C$\sub$v/ and k) is higher in case of vertically reconstituted specimen than horizontally reconstituted specimen.

  • PDF

한국형 발사체 적용 대형 박판 배관 시편 제작 및 성능 평가 (Manufacturing and Performance Evaluation on Specimen pipes with Large Size Diameter and Thin Thickness for KSLV-II)

  • 이한주;이정호;오승협
    • 항공우주기술
    • /
    • 제12권1호
    • /
    • pp.81-86
    • /
    • 2013
  • 본 연구에서는 다양한 발사체 추진기관 공급계 배관 자재 중 STS 300 계열의 금속보다 강도가 높고 용접성이 우수할 것이라고 판단되는 21-6-9 합금소재를 이용하여 산화제 주배관의 시편을 제작 하였다. 제작된 시편은 내압 시험을 수행하여 요구되는 내압 강도를 유지할 수 있는지를 확인하였다.

한국산 산민달팽이(Incilaria fruhstorferi) 장웅동체관 상피의 계절에 따른 미세구조의 변화 (Ultrastructural Changes of the Hermaphrodite Duct Epithelium by Season in a Korean Slug Incilaria fruhstorieri)

  • 장남섭;정계헌
    • 한국동물학회지
    • /
    • 제39권2호
    • /
    • pp.139-146
    • /
    • 1996
  • A studv on the ultrastructural changes of the hermaprodite duct epithelium in spring and summer specimens of a Korean slug Incirovia fruhstorferi was conducted. In spring specimen, the hermaphrodite duct was 0.3 H 0.2 mm in diameter and seemed to be a little bit abnormal feature, due to shrinkage. The epithelium of the duct was composed of cells containing various-sized vacuoles and their cytoplasm showed high electron density. In summer specimen, the hermaphrodite duct was 0.4 $\times$ 0.23 mm in diameter and seemed to be more voluminous than that of the spring specimen. The lumen of the duct in the summer specimen was lined by a epithelium composed of several cell types such as ciliated cuboidal, pseudostratified cuboidal, ciliated columnar and irregular cells. Phasocvtotic activities of the duct epithelium are observed only in the summer specimen. Both of the duct epithelia in the spring and summer specimens were surrounded by connective tissues at their bases. The results obtained suggest that the duct epithelia of the slugs experience seasonal variation in relation to their reproductive cycles.

  • PDF

압입에 따른 알루미나 세라믹스의 이축 파괴 거동 (Biaxial Fracture Behavior of Alumina Ceramics : Indentation Effect on Ball-on-3-ball Test)

  • 정성민;박성은;이홍림
    • 한국세라믹학회지
    • /
    • 제37권7호
    • /
    • pp.713-720
    • /
    • 2000
  • The biaxial fracture behavior of alumina ceramics was studied using ball-on-3-ball test. The polished surfaces of alumina specimens were indented at 0mm, 1mm, 2mm, 3mm apart from the center of the specimen along path A, passing between the two supporting balls from the center of the specimen, and along path B, passing above the three supporting balls from the center of the specimen. The fracture strength of the indented specimens was measured using the ball-on-3-ball test, a kind of biaxial strength test. The fracture strength increased with increasing the distance from the center to indented position. The fracture strength of the specimen indented along path B was higher than that of the specimens indented along path A. It was presented that the fracture caused by tangential stress rather than radial stress when the indented positions are 1mm and 2mm from the center of the specimen. This phenomenon was in good agreement with FEM analysis.

  • PDF