A MOLECULAR BIOLOGIC STUDY ON BIOCOMPATIBILITY OF METALLIC DENTAL MATERIALS USED FOR CHILDREN WITH CULTURED HUMAN GINGIVAL FIBROBLASTS (인체 섬유모세포(HGF-1) 배양에서 소아용 치과금속재의 세포친화성에 대한 분자생물학적 연구)

  • Kim, Ju-Mi;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.243-254
    • /
    • 2002
  • For the purpose of evaluating the biocompatability of 3 kinds of metallic materials frequently used in pediatric dentistry (stainless steel crown, orthodontic band, orthodontic wire), cellular and molecular studies, including cell growth and proliferation, screening of cell death with determination of types whether necrosis or apoptosis and changes in expressions of related signaling molecules were examined, using cultured human gingival fibroblasts (HGF-1), HGF-1 was cultured in Dulbecco's modified Eagle's medium. among which the 3rd to 6th generations of HGF-1 were used. The specimen were divided into stainless steel crown (R), band (B) and wire (W). The immunocytochemical study was done for the detection of anti-PCNA (proliferating cell nuclear antigen) labeling. With extracted protein, western blot was done for the detection of ERK1/2, JNK, and p38, using individual antibodies. Cultured cells proliferated, remarkably till 7 day and slightly at 11 day. There was no statistical significance in the counts of proliferating HGF-1 between control and experimental groups (p>0.05). Relative growth rates were no statistically significant difference between control and experimental groups (p>0.05). PCNA labeling indexes showing similar patterns in control and experimental groups. The expressions of ERK1 and ERK2, p38 were similar in control and experimental groups. The expression of JNK increased at 1st day, slightly decreased at 4th day and markedly increased at 7th and 11 day. Although the patterns of control and experimental groups were similar, the increased expressions of JNK at late period suggest a possible stress due to inhibited cell growth and proliferation, and worse culture condition. Conclusively, the 3 kinds of metal specimens used in this study did not induce cellular and molecular hazards during short term culture of HGF-1. But, for the better clinical stability, the establishment of long period culture and animal experiment was thought necessary.

  • PDF

A STUDY ON WEAR RESISTANCE OF FLOWABLE COMPOSITE RESINS (유동성 복합레진의 마모저항성에 관한 연구)

  • Yun, Yeon-Hee;Kim, Jung-Wook;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.217-225
    • /
    • 2002
  • When we use the flowable resin on the primary molars for quick handling, one of the most important property is the wear resistance. This study was performed to compare the wear resistance characteristics of four flowable composite resins [Arabesk flow (group 1), Tetric flow (group 2), Aeliteflow (group 3), Filtek flow (group 4)] to that of one control composite resin [Z100 (group 5)]. Specimen discs(n=10), 10mm wide and 2mm thick, were stored in distilled water at $37^{\circ}C$ for 7 days prior to testing. The specimens were subjected to 50,000 strokes at 2 Hz on the MTS system. During the test, the following parameters were maintained: the lateral excursion at 0.4mm, occlusal force at 2-100N with a force profile in the form of a half sine wave. The measurements of volume loss, depth of wear, and Vicker's hardness number of composite resins, and SEM observations of the polished and abraded surfaces were established. One-way ANOVA and Scheffe's multiple comparison test were employed to detect statistically significant differences among the flowable composite resin groups and the control composite group at P<.05. The following results were obtained: 1. Group 3 showed the least volume loss, while group 4 showed the greatest. The mean volume loss increased in the following order: group 3

  • PDF

THE EFFECT OF FLUORIDE VARNISH AND ACIDULATED PHOSPHATE FLUORIDE GEL ON ARTIFICIAL CARIES LESION - A MICROCOMPUTED TOMOGRAPHIC STUDY - (Fluoride Varnish와 Acidulated Phosphate Fluoride Gel이 인공우식 병소에 미치는 영향에 대한 미세전산화 단층 촬영을 이용한 연구)

  • Moon, Sung-Kwon;Lee, Jae-Cheoun;Kim, Young-Jae;Lee, Sang-Hoon;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.212-222
    • /
    • 2004
  • The application of acidulated phosphate fluoride gel(APF) and fluoride varnishes are the most common topical fluoride therapy. The purpose of this in vitro study was to compare the remineralization effects of two topical fluoride agents, APF gel and fluoride varnish with microtomograph and 3D image analyzer without sample preparation and chemical fixation. For the purpose of the study, the artificial caries lesion was caused on the caries-free permanent pre molar and 48 specimens were divided into three groups each containing 16 specimens No application was performed on group 1, which acted as control group. Group 2 was treated with APF gel and was removed after a minute. Group 3 was treated with the topical application of fluoride varnish and removed after 45 minutes. Each specimen was placed into a closed container with 50ml of a artificial saliva during three months and the 3D images of the remineralization area were taken using the SkyScan each month. Using the density-measuring program in V $works^{TM}$, the density value of the remineralization area was measured. The following results were obtained: 1. All groups demonstrated an increase in the density of artificial caries lesion with time. 2. The density was significantly higher in APF gel and fluoride varnish group than control group at 1 month, 2 months, 3 months after the treatment(P<0.05). 3. The difference of the density between that "prior to treatment" and that "1 month after treatment" in Group 2 and Group 3 was significantly higher than that of Group 1 and, the difference of the density between that "1 month after treatmen" and that "2 month after treatment" in Group 3 was significantly higher than that of Group 1 and 2(P<0.05). 4. The fluoride varnish was more effective after 2 and 3 months and continuous than the APF gel.

  • PDF

CHEMICAL DEGRADATION OF VARIOUS COMPOMERS IN NaOH (콤포머의 NaOH 용액 내에서의 화학적 분해)

  • Park, Mi-Ran;Choi, Nam-Ki;Lee, Young-Jun;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.144-152
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation of three commercial compomers in an alkaline solution. Dyract(Dentsply), Elan(Kerr) and F-2000(3M) polyacid modified resin composites(compomers) were used in this study. The resistance to degradation was evaluated on the basis of mass loss(%), degradation $depth({\mu}m)$ and Si, Al, Ba loss(ppm). The results were as follows : 1. The mass loss of each brand was $1.42%{\sim}2.14%$ and there was no statistically significant difference of mass loss among Dyract, F2000 and Elan. 2. The degradation layer depth of each brand was $182.92{\sim}227.7{\mu}m$ and there was no statistically significant difference of degradation layer depth among Dyract, F2000 and Elan. 3. There was statistically significant differences in Si-loss and Al-loss among three compomers (p<0.05). Si loss was the highest value in Dyract and Al loss was the highest value in F2000. 4. There was statistically significant correlation between mass loss and degradation layer depth (r=0.60, p<0.05). 5. In SEM finding, there was some destruction of compomer matrix-filler interface in post-exposure specimen to NaOH solution. As the matrix decreased, the filler particles distinguished and the periphery of the filler particles appeared whitish color due to degradation.

  • PDF

WEAR AND CHEMICAL DEGRADATION OF ESTHETIC RESTORATIVE MATERIALS (심미수복 재료의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Hun-Ju;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.190-201
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four esthetic restorative materials in an alkaline solution. The brands studied were Charmfil, Charmfil flow(composite resin), Compoglass F and PrimaFlow(compomer). The results were as follows: 1. The mass loss were not significantly different among the materials(p>0.05). 2. The sequence of the degree of degradation layer depth was in descending order by Compoglass F, PrimaFlow, Charmfil, and Charmfil flow. There were significant differences between Compoglass F and the others(p<0.05). 3. The sequence of the Si loss was in descending order by Charmfil flow, Charmfil, PrimaFlow, and Compoglass F. There were significant differences among these materials(p<0.05). 4. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. 5. The sequence of maximum wear depth was in descending order by Comfoglass, PrimaFlow Charmal, and Charmfil flow. There were significant differences among these materials(p<0.05). 6. The correlation coefficient between Si loss and degradation layer depth (r=0.602, p<0.05) Vicker's hardness number and maximum wear depth (r=0.501, p<0.05) were relatively high. These results indicate that wear and hydrolytic degradation may be considered to be evaluation factors of composite resins and compomers.

  • PDF

COMPARISON OF MICROTENSILE BOND STRENGTH OF COMPOSITE RESTORATION TO ERODED ENAMEL BY SURFACE TREATMENT (접착제의 종류에 따른 침식치아에 대한 복합레진의 결합강도)

  • Lee, Soon-Young;Lee, Kyung-Ho;Noh, Hong-Seok;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.4
    • /
    • pp.348-354
    • /
    • 2011
  • Composite resin has been widely used for eroded enamel. But, as there have been many reports about the differences in physicochemical characteristics of eroded enamel compared with sound enamel, an additional effort was thought necessary to obtain the optimal bond strength. As a possible answer, we came to think about the application of infiltrant resin which is known to have an excellent penetration capacity into enamel. This study was performed for the purpose of comparing the bond strength of composite restoration with or without infiltrant resin under adhesives on the artificially eroded enamel. 60 extracted sound maxillary primary incisors were selected and divided into group 1, 2, 3 according to the number of artificial erosion cycling for 5 minute duration in 1% citric acid of pH 3.2 at $37^{\circ}C$. And the labial surfaces were divided into 3 areas; group A, only resin adhesive was used, group I, only infiltrant resin, group IA, infiltrant resin followed by resin adhesive. Afterwards, every specimen was restored with composite resin. Microtensile bond strength was measured and failure modes were observed. The obtained results were as follows: 1. In comparing the bond strength by the degree of enamel erosion, it was revealed the highest bond strength in group 1, followed by group 2 and 3, showing the lowest bond strength in most eroded group(p<0.05). 2. In comparing the bond strength by surface treatment methods, group IA and I showed higher value than group A(p<0.05), with unsignificant difference between group I and IA(p>0.05). 3. In observation of failure mode, it was shown higher frequency of cohesive failure in order of 1-2-3 and IA-I-A. Conclusively, it was shown decreasing tendency of bond strength as the enamel is more eroded, and infiltrant resin was thought helpful to replace or add to the resin adhesive for optimal bonding with eroded enamel.

Shaping characteristics of two different motions nickel titanium file: a preliminary comparative study of surface profile and dentin chip (두 가지 다른 행정의 니켈 티타늄 파일의 성형 성상: 표면 성상, 상아질 삭편과 도말층에 대한 예비적 비교 연구)

  • Park, So-Ra;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.121-130
    • /
    • 2014
  • Purpose: To assess the surface profile of dentinal wall, dentin chips and smear layer during the canal shaping with rotary (ProTaper) and ProFile and reciprocating (WaveOne) nickel-titanium file. Materials and Methods: Sixty human extracted mandibular premolars and incisors with single canals were randomly selected. Three experimental groups (n = 20) were instrumented with ProTaper (F2), ProFile (25/.06), WaveOne (25/.08) with irrigation of 2.5% NaOCl. The dentin chips were collected from flute of file during each canal preparation. After canal preparation, roots were grinded and each group was divided into two subgroups (n = 10) for surface profile and smear layer of dentinal wall of shaped root canal. Each specimen was observed under scanning electron microscope for evaluating size of dentin chips, root canal surface recessions and smear layer. Scores of Smear layer were statistically analyzed using Kruskal Wallis test and Mann Whitney test at P = 0.05 level. Results: The size of dentin chips from ProFile, ProTaper and WaveOne was up to $7{\mu}m$, $6.5{\mu}m$, and$4{\mu}m$, respectively. In the surface profile, the width of surface irregularity was measured and Profile, ProTaper and WaveOne was up to $150{\mu}m$, $70{\mu}m$, and $80{\mu}m$, respectively. Completely cleaned root canals were not found. In the middle and apical third of the canals, WaveOne group showed higher smear layer score than ProFile and ProTaper groups (P < 0.05). Conclusion: Within limits of this study, reciprocating motion WaveOne group was not significant difference of shaping ability with the full-sequence ProFile and ProTaper systems except canal clearness of middle and apical third of root canal. When using WaveOne to shaping root canal, thorough root canal irrigation is recommended.

p53 and c-erbB2 as the Immunohistochemical Markers in Patients with Squamous Cell Carcinoma of the Lung (편평상피 폐암 및 주위 정상조직에서 p53 및 c-erbB2 발현의 의의)

  • Song, Chang-Seuk;Ok, Chul-Ho;Jung, Yong-Seuk;Jang, Tae-Won;Jung, Maan-Hong;Lee, Jae-Seong;Jung, Hae-Jeen;Hur, Bahng;Hur, Man-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.523-532
    • /
    • 1999
  • Background: With the development of the molecular biological methods, studies of the early diagnosis of lung cancer and the detection in the preneoplastic state by using genetic probes in the high risk groups are widely investigated. In lung cancer, squamous cell carcinoma is considered to progress from the normal bronchial mucosa to the preneoplastic state, and finally to the invasive carcinoma. In this study, we investigated the expression of p53 and c-erbB2 in the normal bronchi and the cancer tissues in patients with squamous cell lung cancer to evaluate the possibility of using these immunohistochemical markers as the diagnostic and prognostic parameters of patients with squamous cell lung cancer. Method: The normal and cancerous bronchial tissues of 25 patients with squamous cell carcinoma of the lung, surgically resected from May 1995 to November 1996, were immunohistochemically stained with the monoclonal antibodies to p53(DAKO-p53) and c-erbB2(phamingen 15821A) respectively. We compared the expression status of these markers between the normal bronchial mucosa and the tumor tissue, and also investigated the relationship between the expression status of these markers in tumor tissues and the pathological stage, and the survival time. Results: The pathological stage was as follows; stage I, II were found in 5 patients respectively, stage IIIA was in 8 patients, stage IIIB was in 4 patients, and stage IV was in 3 patients. The expression rate of p53 in the squamous cell lung cancer was 48%, and it was not expressed in the normal bronchial mucosa. The expression status was increased as the pathological stage advanced(p=0.0091 by test of trend). But there were no relationship between the expression of p53 and the median survival time. C-erbB2 did not yield a significantly meaningful result. Conclusion: p53 was not found in the normal bronchial mucosa, but it was expressed in 48% of the tumor tissue. And the expression rate increased as the pathological stage advanced. So it would be helpful to apply the immunochistochemical stain with p53 in the bronchial biopsy specimen in the early diagnosis trial or staging of squamous cell lung cancer.

  • PDF

Pulmonary Oxalosis Caused by Aspergillus Niger Infection (Aspergillus Niger 감염에 의한 폐옥살산염 1예)

  • Cho, Gye Jung;Ju, Jin Young;Park, Kyung Hwa;Choi, Yoo-Duk;Kim, Kyu Sik;Kim, Yu Il;Kim, Soo-Ok;Lim, Sung-Chul;Kim, Young-Chul;Park, Kyung-Ok;Nam, Jong-Hee;Yoon, Woong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.516-521
    • /
    • 2003
  • The Aspergillus species produces metabolic products that play a significant role in the destructive processes in the lung. We experienced a case of chronic necrotizing pulmonary aspergillosis caused by an Aspergillus niger infection, which contained numerous calcium oxalate crystals in the necrotic lung tissue. A 46-year-old man, who had a history of pulmonary tuberculosis, presented with high fever, intermittent hemoptysis and pulmonary infiltrations with a cavity indicated by the chest radiograph. Despite being treated with several antibiotics and anti-tuberculosis regimens, the high fever continued. The sputum cultures yielded A. niger repeatedly, and intravenous amphotericin B was then introduced. The pathological specimen obtained by a transbronchial lung biopsy revealed numerous calcium oxalate crystals in a background of acute inflammatory exudates with no identification of the organism. Intravenous amphotericin B was continued at a total dose of 1600 mg, and at that time he was afebrile, although the intermittent hemoptysis continued. On the $63^{rd}$ hospital day, a massive hemoptysis (about 800 mL) developed, which could not be controlled despite embolizing the left bronchial artery. He died of respiratory failure the next day. It is believed that the oxalic acid produced by A. niger was the main cause of the patient's pulmonary injury and the ensuing massive hemoptysis.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF