• Title/Summary/Keyword: Specific humidity

Search Result 256, Processing Time 0.03 seconds

Comparative Research of Fog Using the Regular Observation and GPS Integrated Water Vapor (정규관측자료와 GPS 연직누적 수증기량을 이용한 안개에 대한 비교연구)

  • Lee, Jaewon;Cho, Jungho;Baek, Jeongho;Park, Jong-Uk;Park, Chieup
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.417-427
    • /
    • 2008
  • In this paper, we analyzed the physical and thermodynamic characteristics of fog by using the integrated water vapor (IWV) from Global Positioning System (GPS) networks and the regular observation data of meteorological stations in GPS sites. The cases of a radiation and an advection fog were selected as samples, the conversions of water substance from the water vapor to cloud water in fog were detected by the Bulk Water-Continuity Model, and the pattern analysis is adapted on GPS IWV, temperature, wind and relative humidity. Under the specific hypothesis (saturation and stable), GPS IWV could detect quantitatively the phase changing between the water vapor and cloud water content with condensation/evaporation during the formation and dissipation of fog. After it reaches to the saturation, the relative humidity can be a limited indicator for fog. However, GPS IWV can detect the status change of fog even after the saturation. It has indicated that GPS IWV could be a new observing technique for the processes of the fog formation and the dissipation.

On Interesting Correlation between Meteorological Parameters and COVID-19 Pandemic in Saudi Arabia

  • Haq, Mohd Anul;Ahmed, Ahsan
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.4
    • /
    • pp.159-168
    • /
    • 2022
  • The recent outbreak of COVID-19 pandemic cases around the globe has affected Saudi Arabia with around 15, 00,000 confirmed cases within the initial 4 months of transmission. The present investigation analyzed the relationship between daily COVID-19 confirmed cases and meteorological parameters in seventeen cities of KSA. We used secondary published data from the Ministry of Health, KSA daily dataset of COVID-19 confirmed case counts. The meteorological parameters used in the present investigation are temperature, humidity, dew point, and wind speed. Pearson correlation and Spearman rank correlation tests were utilized for data analysis. The incubation period of COVID-19 varies from 1 day to 14 days as per available information. Therefore, an attempt has been made to analyze the effects of meteorological factors with bins of 1, 3, 7, and 14 days. The results suggested that the highest number of correlations (15 cities) was observed for temperature (maximum, minimum, and average) and humidity (12 cities) (minimum and average). The dew point showed relationships for 7 cities and wind showed moderate correlations only for 2 cities. The study results might be useful for authorities and stakeholders in taking specific measures to combat the Covid-19 pandemic.

Effects of Drying Methods Based on Exhaust Cycle and Time on the Quality and Drying of Red Peppers

  • Nam, Sang Heon;Ha, Yu Shin;Kim, Tae Wook
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.101-110
    • /
    • 2014
  • Purpose: The purpose of this study is to develop a system to optimize drying potential energy of the exhausted hot air by changing relative humidity of the air. This study modified the conventional drying method into a drying method changing exhaust cycle and time in order to control the relative humidity of the exhausted hot air during drying process. Method: A valve on the vent was controlled according to a preset time to change the exhaust cycle and time. This study analyzed the influence of the two different types of drying method on the drying characteristics, required energy, and quality of the dried peppers: conventional drying method exhausting hot air continuously and new drying method controlling exhaust cycle and time. Results: Drying characteristics based on exhaust time showed that drying time increased with exhaust time, and specific energy consumption was reduced by 28% from 18.39 MJ/kg (conventional method) to 13.24 MJ/kg when exhaust time was set to one minute. Drying characteristics based on heating time showed that drying time increased with heating time and specific energy consumption was reduced by 30% from 18.39 MJ/kg (conventional method) to 12.87 MJ/kg when exhaust time was set to 22 minutes. Drying characteristics based on exhaust cycle showed that drying time increased with exhaust cycle, and specific energy consumption was reduced by 31% from 18.39 MJ/kg (conventional method) to 12.69 MJ/kg when exhaust time was set to one minute and exhaust cycle was set to 22 minutes before drying and 40 minutes after drying. The quality of the dried red peppers showed that capsaicin, color, and sugar content were high as 34.87 mg/100g, 66.33, and 11.87%, respectively, when exhaust time was set to one minute and exhaust cycle was set to 22 minutes before drying and 40 minutes after drying. Conclusions: In order to utilize the drying potential energy of the exhausted air during drying process, the conventional drying method was modified into the drying method controlling exhaust cycle and time. The results showed that drying with exhaust cycle of one minute was more efficient in terms of drying time, required energy, and quality of the dried peppers than the one with exhaust cycle of 20~40 minutes.

A Stuey on the Design of Nano-Saboratory for the Control of Environmental Parameters (Nano-Laboratory 설계환경 조절에 관한 연구)

  • 이응석;염영일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.231-236
    • /
    • 1993
  • To disign and build a ultra-precision laboratory which has been required for high technology in many areas, the environmental parameters such as temperature, humidity,vibration and nosic are controlled precisely. To absorb the outside vibration, particular concrete blocks were designed and set under the laboratory. The inside room temperature were controlled in local area within .+-. 0.3 .deg. c. It was efficient to induce laminar flow in air conditioning system for the control of room temperature, humidity etc. The control conditions should be determined according to their specific purposes. Also, the control method will be different for their respective environmental conditions.

  • PDF

Effect of Surface Finishing Materials on the Moisture Conditions in Concrete: Vapor and Water Permeability of Finishing Materials Under Changing Environmental Conditions

  • Ryu, Dong-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.2
    • /
    • pp.83-90
    • /
    • 2008
  • Permeability to vapor and water among other performances required for finishing materials is dealt with in this study. The relative moisture content of concrete coated/covered with a finishing material was experimentally investigated while changing the environmental conditions including temperature, relative humidity, and rainfall. An organic paint (water-based urethane), organic synthetic resin emulsion-type film coating (film coating E), and inorganic porcelain tiles were selected as the finishing materials. When compared from the aspect of vapor and water permeability, the vapor permeability and water permeability of water-based urethane were high and low, respectively; those of film coating E were high and high, respectively; and those of porcelain tiles were low and low, respectively. This means that the moisture state of concrete structures is governed not only by the environmental conditions but also by the performance of finishing materials. It is therefore of paramount importance to appropriately select a finishing material to address the specific deteriorative factors involved in the concrete structure to be finished.

GIS-based Meteorological Data Processing Technology for Forest Fire Danger Rating Forecast System of China

  • Zhao, Yinghui;Zhen, Zhen;Li, Fengri
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.2
    • /
    • pp.197-203
    • /
    • 2010
  • The data of average temperature, average relative humidity, precipitation and average wind speed were collected from 674 meteorological stations in China. A specific procedure that processes original data into a new data format needed in forest fire danger rating forecast system of China was introduced systematically, and the feasibility of this method was validated in this paper. In addition, a set of meteorological data processing software was constructed by the secondary development of GIS in order to realize automation of processing data for the system. Results showed that the approach preformed well in handling temperature, average relative humidity and average wind speed, and the processing effect of precipitation was acceptable. Moreover, the automated procedure could be achieved by GIS and the working efficiency was about 3 times as much as that of manual handling. The informationization level of processing meteorological data was greatly enhanced.

Cooling Simulation for Fixed-Bed of Rough Rice (벼 퇴적층 냉각 시뮬레이션)

  • 김동철;김의웅;금동혁
    • Journal of Biosystems Engineering
    • /
    • v.24 no.1
    • /
    • pp.31-40
    • /
    • 1999
  • The objective of this study were to develop a cooling simulation model for fixed-bed of rough rice and to analyze the factors affecting cooling time of rough rice. A computer simulation model based on equilibrium conditions between grain and air was developed to predict temperature and moisture content changes during cooling of rough rice. the result of t-test showed that there were no significant differences between predicted and measured temperature changes on significance model agreed well with measured values. This cooling simulation model was applied to analyze the effect of some factors, such as air flow rate, cooling air temperature and humidity, initial grain temperature and moisture content, and bed depth, on cooling time of rough rice. Cooling rate increased with increase of air flow rate and bed depth whereas it decreased with increase of cooling air temperature and humidity and initial grain temperature. Among these factors, the most important factor was air flow rate. Specific air flow rate of 0.35㎥/min㎥ was required for cooling rough rice in 24 hours.

  • PDF

An Estimation of Cooling Load for Control of Ice Storage System (빙축열 시스템의 제어를 위한 냉방부하 예측)

  • Yoo, Seong-Yeon;Han, Seung-Ho;No, Kwan-Jong;Lee, Je-Myo;Kang, Tae-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.205-210
    • /
    • 2005
  • Ice storage system stores cold energy using ice, which is used for cooling on next day. Ice storage system is the effective cooling system that uses cheep electric energy during a night, and also suppresses the peak load of electricity. In this study, the normalized temperature, relative humidity and specific humidity are analyzed using the weather data for past five years in order to estimate the cooling load for the control of ice storage system. The calculated cooling loads show fairly good agreement with the measured data of model hospital, especially at the outdoor design temperature of $25^{\circ}C$.

  • PDF

Long-term Trends of Visibility in Seoul and Chunchon (서울과 춘천의 장기간 시정 변화경향)

  • 이종범;김용국;백복행
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.473-478
    • /
    • 1996
  • Using data observed from 1966 to 1994, long-term trends of visibility at 15:00 in Seoul and Chunchon were analyzed. Annual average visibility in Seoul has been decreased continuously. In particular, annual number of days for visibility more than 15km was remarkably reduced since 1980. Also, the trend of the visibility in Chunchon was similar to that of Seoul. But the variations were small to compare with Seoul. Long-term trends of relative humidity (RH) and specific humidity (q) at 15:00 in Seoul have been slightly decreased. Cumulative frequency distributions of visibility for ranges of RH (0 $\sim 50%, 50 \sim 60%, 60 \sim 70%, 70 \sim 80%, 80 \sim 90%, 90 \sim 100%$) at 15:00 in Seoul and Chunchon were generally decreased during the second period (1984 $\sim$ 1994) as compared with the first period (1973 $\sim$ 1983), except for the range of 90 to 100% RH. Despite of decreasing phenomena of RH, characteristics of urban climates in Seoul, visibility degraded due to an increase of air pollution.

  • PDF

Electrical Properties of Outdoor Insulator with the Difference of Contaminated Condition (오손조건에 따른 옥외절연물의 전기적 특성)

  • 최남호;구경완;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.467-470
    • /
    • 2000
  • This paper present the result of the investigation, electric properties of outdoor insulators with the difference of contaminated condition. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. A mini-fog chamber with transparent acryl and the standard contamination solution with kaoline was used. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current and the ambient condition, such as relative humidity and temperature, a DAS system was developed with LabView. From the result, we could know the influence of contaminated condition. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF