염진해 오손물질의 성분 및 특성 (The Ingredient and the Properties of Contaminants)

  • 최남호;박강식;조성배;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.51-54
    • /
    • 1999
  • In this paper, the relativities, and the properties of various contaminants, which could give significant decrease in electrical insulation strength were investigated. For this investigation, the contamination degree was manually measured with brush-wiping method, and the ingredient of some specific sample was analyzed with ICP/MS. With the result, the influence of distance from sea, climatic condition contamination was investigated. And the difference in electrical properties of various salts in aquous solution was determined. Finally, we could get several significant result on the relativity and properties of contamination in various conditions

  • PDF

시장의약품(市販醫藥品)의 미생물(微生物) 오염도(汚染度) 조사(調査) (제1보)(第1報) -시판내복액제(市販內服液劑)의 세균오염도(細菌汚染度)- (A Survey on Microbial Contamination of Currently-Sold Drugs (I) -Bacterial contamination of marketed liquid-)

  • 박영주;김영일
    • Journal of Pharmaceutical Investigation
    • /
    • 제3권4호
    • /
    • pp.5-15
    • /
    • 1973
  • An investigation was carried out on a basis of the bacteriological examination with a view to detecting the degree of bacterial contamination for the 77 samples collected from the locally-sold liquid specialties. It's test period was 50 days from July 10 to August 30, 1971. Specially, the survey has put emphasis on the population of general bacteria and the identification of coli-form group, staphylococcus species, streptococcus species, bacillus species, fungi, and yeast species from liquid samples. The results obtained are summarized as follows; (1) For the 77 samples tested, the contamination of general bacteria was found out as minimun 0, i,e., maximum, $12{\times}10^4$ and the total average $45{\times}10^2$ per milliliter. (2) Although streptococcus species could not be detected with the samples, the contamination of the coli-form and staphylococcus species means the strong suggestion of the possibility of pathogenic bacterial contamination. (3) Specially, the products which stay in the neutral pH range and use suspending agents need to care for the microbial contamination in the manufacturing crocess. (4) It is thought necessary to perform the microbiological quality control in the liquid preparations only at least. (5) As the microbial contamination degree in the liquid decreases according to the elapse of time, the microbiological quality control will have to be carried out immediately after the completion of the manufacturing process in order to know the accurate degree. (6) The author thinks that the main reason of the microbial contamination in the liquid is the contamination during the manufacturing process. (7) For the purpose of prevention of the microbial contamination in liquid, therefore, it is more important to make efforts for the rationalization of manufacturing process, the improvement of equipment and environment, the specific training of workers for hygienic knowledges, etc. rather than the use of preservatives for the preparations.

  • PDF

토양.지하수오염원 분류체계 구축방안: 2. 분류체계 구축 및 속성자료 활용방안 (Building a Classification Scheme of Soil and Groundwater Contamination Sources in Korea: 2. Construction of Classification System and Applications of Attribute Data)

  • 안정이;신경희;황상일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권6호
    • /
    • pp.122-127
    • /
    • 2010
  • Constructing the national inventory that can be used as a tool to identify and assess existing or potential contamination is necessary for efficiently managing the soil and groundwater contamination. In order to start this construction, the first step is how we define and classify potential contamination sources of soil and groundwater. After selecting the basic classification model of contamination sources from developed countries, we suggested the classification and list of the potential contamination sources of soil and groundwater which are appropriate for specific conditions of South Korea. In addition, we investigated several databases to confirm the existence of available data sources and then examined established attribute data through chemical accident response information system (CARIS) and water information system (WIS) in National Institute of Environmental Research and mine geographic information system (MGIS) in Mine Reclamation Corporation. All sorts of attribute data in the existing databases can be utilized as significant assessment factors for determining the management priority of potential contamination sources in the future. Therefore, it is required the expanded investigation of additional database sources and the continual modification so that the classification system of potential contamination sources can be improved.

An Experimental Investigation on the Contamination Sensitivity of an Automotive Fuel Pump

  • Lee Jae-Cheon;Shin Hyun-Myng
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권3호
    • /
    • pp.51-55
    • /
    • 2005
  • This study addresses the contamination sensitivity test of a typical fuel pump for an automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of a fuel pump on specific contaminant particle sizes so that an optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of the fuel pump is measured under the experiments of various contaminants size ranges of ISO test dust up to $80\;{\mu}m$. The fundamental theory of contamination sensitivity is introduced and the contamination sensitivity coefficients are estimated using the experimental data. Maximum contamination sensitivity coefficient of $5\chi\;10^{-6}\;L/min{\cdot}Ea$ is found in the contaminant size range of $40\;{\mu}m\~50\;{\mu}m$. The magnified picture of the surface of vane disc reveals that the abrasive wear is the principal cause of discharge flow rate degradation. Hence, this study reveals that a high efficiency filter for contaminant particles especially in the size range of $30\;{\mu}m\~70\;{\mu}m$ especially should be used to maintain the service life of the fuel filter.

자동차 연료펌프의 오염민감도 실험 연구 (An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump)

  • 이재천;장지현;신현명
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

국내 오염부지 조사 개선을 위한 US EPA 스마트 스코핑 기술 소개 (Introduction to US EPA Smart Scoping Technical Guide for Improving Pollution Site Investigation)

  • 김보민;김한석;권만재;조호영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권2_spc호
    • /
    • pp.70-85
    • /
    • 2020
  • This paper introduces the 'Smart Scoping for Environmental Investigations Technical Guide' issued by the US Environmental Protection Agency in 2018, which describes the use of smart scoping during lifecycle of remedial investigation projects. This paper also briefly summarizes the guidelines of soil and groundwater contamination investigation of South Korea. The smart scoping practices can support the development of a robust and realistic conceptual site model that is very useful for investigations and evaluations of the contaminated site. The application of evaluation tools relevant for the site-specific characteristics is important for the development of a conceptual site model. The smart scoping recommends the use of previous investigation data and implementation of best proven strategies for successful remedial investigation project. The use of smart scoping in contaminated site investigation will provide better management of contaminated sites.

오손조건에 따른 옥외절연물의 전기적 특성 (Electrical Properties of Outdoor Insulator with the Difference of Contaminated Condition)

  • 최남호;구경완;박강식;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.467-470
    • /
    • 2000
  • This paper present the result of the investigation, electric properties of outdoor insulators with the difference of contaminated condition. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. A mini-fog chamber with transparent acryl and the standard contamination solution with kaoline was used. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current and the ambient condition, such as relative humidity and temperature, a DAS system was developed with LabView. From the result, we could know the influence of contaminated condition. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

불용성 오손물에 의한 절연물의 전기적 특성에 관한 연구 (The Electric Properties of Insulators Due to Non-soluble Contaminant)

  • 최남호;국연호;조성인;박강식;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.691-695
    • /
    • 2000
  • This paper present the result of the investigation, the electric properties of insulators due to non-soluble contamination. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. Though the non-soluble do not distribute on conductivity of contaminant layer, that has the hygroscopic property. For this study, we make a mini-fog chamber with transparent acryl and the kaoline was used for non-soluble contaminant. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current a DAS system was developed with LabView. With the result, we could know the influence of non-soluble content and the relationship between NSDD and ESDD.

  • PDF

Novel approach to predicting the release probability when applying the MARSSIM statistical test to a survey unit with a specific residual radioactivity distribution based on Monte Carlo simulation

  • Chun, Ga Hyun;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1606-1615
    • /
    • 2022
  • For investigating whether the MARSSIM nonparametric test has sufficient statistical power when a site has a specific contamination distribution before conducting a final status survey (FSS), a novel approach was proposed to predict the release probability of the site. Five distributions were assumed: lognormal distribution, normal distribution, maximum extreme value distribution, minimum extreme value distribution, and uniform distribution. Hypothetical radioactivity populations were generated for each distribution, and Sign tests were performed to predict the release probabilities after extracting samples using Monte Carlo simulations. The designed Type I error (0.01, 0.05, and 0.1) was always satisfied for all distributions, while the designed Type II error (0.01, 0.05, and 0.1) was not always met for the uniform, maximum extreme value, and lognormal distributions. Through detailed analyses for lognormal and normal distributions which are often found for contaminants in actual environmental or soil samples, it was found that a greater statistical power was obtained from survey units with normal distribution than with lognormal distribution. This study is expected to contribute to achieving the designed decision error when the contamination distribution of a survey unit is identified, by predicting whether the survey unit passes the statistical test before undertaking the FSS according to MARSSIM.

금호강, 남강 중권역 지류·지천의 상세오염 현황 및 오염기여율 조사 (Analysis of Specific Contaminated Status and Pollutant Loads Contribution Rate of the Tributaries in Gumho and Nam River Basin)

  • 나승민;권헌각;김경훈;신동석;임태효
    • 한국습지학회지
    • /
    • 제18권4호
    • /
    • pp.363-377
    • /
    • 2016
  • 본 연구는 낙동강수계 오염도가 높은 금호강 및 남강 중권역의 지천들 가운데 수질측정망과 일정한 거리에 있고 오염도가 높은 지천들을 선정하여 각 지점의 오염부하량, 오염특성, 중점관리지천별 세부 유입되는 지천의 오염현황 및 중점 지류가 낙동강 본류에 미치는 영향 등을 살펴보았다. 그 결과, 금호강 및 남강의 대부분의 수질항목별 오염도는 유사하였으나, TN, Chl-a 및 SS는 금호강이 남강에 비해 약 20~120% 이상 높은 오염도를 보였다. 오염발생부하율(kg/day) 및 발생밀도($kg/day/km^2$)는 유량과 하천유하면적에 따라 하천 오염도 순위가 달랐으며, 이러한 영향은 남강에서 더 크게 차이가 발생하였다. 금호강 및 남강의 상세오염조사는 하천의 유로길이, 합류되는 소하천의 개수와 형태에 따라 상세지점을 2개에서 최대 9개까지 나누어 조사하였으며, 그 결과 달서천과 의령천의 오염도가 높게 나타났다. 이외에도, 달서천과 의령천의 본류오염 기여율이 약 10% 내외로 높게 나타났으며, 이는 주변공단, 생활거주지역 형태 및 크기, 농경지 경작 유 무 및 축사 존재 유 무에 따라 오염도 및 상 하류 오염형태가 다르기 때문으로 판단된다