• Title/Summary/Keyword: Specific contamination investigation

Search Result 25, Processing Time 0.028 seconds

The Ingredient and the Properties of Contaminants (염진해 오손물질의 성분 및 특성)

  • 최남호;박강식;조성배;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.51-54
    • /
    • 1999
  • In this paper, the relativities, and the properties of various contaminants, which could give significant decrease in electrical insulation strength were investigated. For this investigation, the contamination degree was manually measured with brush-wiping method, and the ingredient of some specific sample was analyzed with ICP/MS. With the result, the influence of distance from sea, climatic condition contamination was investigated. And the difference in electrical properties of various salts in aquous solution was determined. Finally, we could get several significant result on the relativity and properties of contamination in various conditions

  • PDF

A Survey on Microbial Contamination of Currently-Sold Drugs (I) -Bacterial contamination of marketed liquid- (시장의약품(市販醫藥品)의 미생물(微生物) 오염도(汚染度) 조사(調査) (제1보)(第1報) -시판내복액제(市販內服液劑)의 세균오염도(細菌汚染度)-)

  • Park, Young-Ju;Kim, Young-Il
    • Journal of Pharmaceutical Investigation
    • /
    • v.3 no.4
    • /
    • pp.5-15
    • /
    • 1973
  • An investigation was carried out on a basis of the bacteriological examination with a view to detecting the degree of bacterial contamination for the 77 samples collected from the locally-sold liquid specialties. It's test period was 50 days from July 10 to August 30, 1971. Specially, the survey has put emphasis on the population of general bacteria and the identification of coli-form group, staphylococcus species, streptococcus species, bacillus species, fungi, and yeast species from liquid samples. The results obtained are summarized as follows; (1) For the 77 samples tested, the contamination of general bacteria was found out as minimun 0, i,e., maximum, $12{\times}10^4$ and the total average $45{\times}10^2$ per milliliter. (2) Although streptococcus species could not be detected with the samples, the contamination of the coli-form and staphylococcus species means the strong suggestion of the possibility of pathogenic bacterial contamination. (3) Specially, the products which stay in the neutral pH range and use suspending agents need to care for the microbial contamination in the manufacturing crocess. (4) It is thought necessary to perform the microbiological quality control in the liquid preparations only at least. (5) As the microbial contamination degree in the liquid decreases according to the elapse of time, the microbiological quality control will have to be carried out immediately after the completion of the manufacturing process in order to know the accurate degree. (6) The author thinks that the main reason of the microbial contamination in the liquid is the contamination during the manufacturing process. (7) For the purpose of prevention of the microbial contamination in liquid, therefore, it is more important to make efforts for the rationalization of manufacturing process, the improvement of equipment and environment, the specific training of workers for hygienic knowledges, etc. rather than the use of preservatives for the preparations.

  • PDF

Building a Classification Scheme of Soil and Groundwater Contamination Sources in Korea: 2. Construction of Classification System and Applications of Attribute Data (토양.지하수오염원 분류체계 구축방안: 2. 분류체계 구축 및 속성자료 활용방안)

  • An, Jeong-Yi;Shin, Kyung-Hee;Hwang, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.122-127
    • /
    • 2010
  • Constructing the national inventory that can be used as a tool to identify and assess existing or potential contamination is necessary for efficiently managing the soil and groundwater contamination. In order to start this construction, the first step is how we define and classify potential contamination sources of soil and groundwater. After selecting the basic classification model of contamination sources from developed countries, we suggested the classification and list of the potential contamination sources of soil and groundwater which are appropriate for specific conditions of South Korea. In addition, we investigated several databases to confirm the existence of available data sources and then examined established attribute data through chemical accident response information system (CARIS) and water information system (WIS) in National Institute of Environmental Research and mine geographic information system (MGIS) in Mine Reclamation Corporation. All sorts of attribute data in the existing databases can be utilized as significant assessment factors for determining the management priority of potential contamination sources in the future. Therefore, it is required the expanded investigation of additional database sources and the continual modification so that the classification system of potential contamination sources can be improved.

An Experimental Investigation on the Contamination Sensitivity of an Automotive Fuel Pump

  • Lee Jae-Cheon;Shin Hyun-Myng
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.3
    • /
    • pp.51-55
    • /
    • 2005
  • This study addresses the contamination sensitivity test of a typical fuel pump for an automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of a fuel pump on specific contaminant particle sizes so that an optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of the fuel pump is measured under the experiments of various contaminants size ranges of ISO test dust up to $80\;{\mu}m$. The fundamental theory of contamination sensitivity is introduced and the contamination sensitivity coefficients are estimated using the experimental data. Maximum contamination sensitivity coefficient of $5\chi\;10^{-6}\;L/min{\cdot}Ea$ is found in the contaminant size range of $40\;{\mu}m\~50\;{\mu}m$. The magnified picture of the surface of vane disc reveals that the abrasive wear is the principal cause of discharge flow rate degradation. Hence, this study reveals that a high efficiency filter for contaminant particles especially in the size range of $30\;{\mu}m\~70\;{\mu}m$ especially should be used to maintain the service life of the fuel filter.

An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump (자동차 연료펌프의 오염민감도 실험 연구)

  • 이재천;장지현;신현명
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

Introduction to US EPA Smart Scoping Technical Guide for Improving Pollution Site Investigation (국내 오염부지 조사 개선을 위한 US EPA 스마트 스코핑 기술 소개)

  • Kim, Bomin;Kim, Han-Suk;Kwon, Man Jae;Jo, Ho Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.2_spc
    • /
    • pp.70-85
    • /
    • 2020
  • This paper introduces the 'Smart Scoping for Environmental Investigations Technical Guide' issued by the US Environmental Protection Agency in 2018, which describes the use of smart scoping during lifecycle of remedial investigation projects. This paper also briefly summarizes the guidelines of soil and groundwater contamination investigation of South Korea. The smart scoping practices can support the development of a robust and realistic conceptual site model that is very useful for investigations and evaluations of the contaminated site. The application of evaluation tools relevant for the site-specific characteristics is important for the development of a conceptual site model. The smart scoping recommends the use of previous investigation data and implementation of best proven strategies for successful remedial investigation project. The use of smart scoping in contaminated site investigation will provide better management of contaminated sites.

Electrical Properties of Outdoor Insulator with the Difference of Contaminated Condition (오손조건에 따른 옥외절연물의 전기적 특성)

  • 최남호;구경완;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.467-470
    • /
    • 2000
  • This paper present the result of the investigation, electric properties of outdoor insulators with the difference of contaminated condition. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. A mini-fog chamber with transparent acryl and the standard contamination solution with kaoline was used. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current and the ambient condition, such as relative humidity and temperature, a DAS system was developed with LabView. From the result, we could know the influence of contaminated condition. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

The Electric Properties of Insulators Due to Non-soluble Contaminant (불용성 오손물에 의한 절연물의 전기적 특성에 관한 연구)

  • 최남호;국연호;조성인;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.691-695
    • /
    • 2000
  • This paper present the result of the investigation, the electric properties of insulators due to non-soluble contamination. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. Though the non-soluble do not distribute on conductivity of contaminant layer, that has the hygroscopic property. For this study, we make a mini-fog chamber with transparent acryl and the kaoline was used for non-soluble contaminant. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current a DAS system was developed with LabView. With the result, we could know the influence of non-soluble content and the relationship between NSDD and ESDD.

  • PDF

Novel approach to predicting the release probability when applying the MARSSIM statistical test to a survey unit with a specific residual radioactivity distribution based on Monte Carlo simulation

  • Chun, Ga Hyun;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1606-1615
    • /
    • 2022
  • For investigating whether the MARSSIM nonparametric test has sufficient statistical power when a site has a specific contamination distribution before conducting a final status survey (FSS), a novel approach was proposed to predict the release probability of the site. Five distributions were assumed: lognormal distribution, normal distribution, maximum extreme value distribution, minimum extreme value distribution, and uniform distribution. Hypothetical radioactivity populations were generated for each distribution, and Sign tests were performed to predict the release probabilities after extracting samples using Monte Carlo simulations. The designed Type I error (0.01, 0.05, and 0.1) was always satisfied for all distributions, while the designed Type II error (0.01, 0.05, and 0.1) was not always met for the uniform, maximum extreme value, and lognormal distributions. Through detailed analyses for lognormal and normal distributions which are often found for contaminants in actual environmental or soil samples, it was found that a greater statistical power was obtained from survey units with normal distribution than with lognormal distribution. This study is expected to contribute to achieving the designed decision error when the contamination distribution of a survey unit is identified, by predicting whether the survey unit passes the statistical test before undertaking the FSS according to MARSSIM.

Analysis of Specific Contaminated Status and Pollutant Loads Contribution Rate of the Tributaries in Gumho and Nam River Basin (금호강, 남강 중권역 지류·지천의 상세오염 현황 및 오염기여율 조사)

  • Na, Seungmin;Kwon, Heongak;Kim, Gyeong Hoon;Shin, Dongseok;Im, Tae Hyo
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.363-377
    • /
    • 2016
  • This study was investigated the pollutant load, contamination properties, pollution condition of the fine parts of tributary, the influence of Nakdong river watershed and etc. in the tributaries. The contaminated tributaries were that among the Kumho and Nam river or were too far from site of water quality monitoring stations, regularly. As a result, the water quality level was almost similar between Nam and Kumho River, except for certain parameter including TN(Total Nitrogen), Chl-a(Chlorophyll-a) and SS(Suspended Solid) in which Kumho river were 20~120%. The point discharge load(kg/day) and load density ($kg/day/km^2$) of tributaries were different the pollution level according to the flow-rate ($m^3/sec$) and stream influence area($km^2$), and the difference of these was observed highly at Nam river. Specific contamination investigation of tributaries in Nam and Kumho river watershed was conducted from two to nine points of the fine parts of tributaries depending on the confluence sites and shapes. This result observed high at the Dalseocheon and Uriyeongcheon, respectively. Beside, the pollutant load contribution rate of Nakdong watershed was high about 10% at the Dalseocheon and Uiryeongcheon. This was due to the differences of the environments about the industrial complex, metropolis residence property, agricultural cultivation, livestock pen and the downstream of non-point source.