• 제목/요약/키워드: Specific absorption rate

검색결과 238건 처리시간 0.023초

Experimental research on dynamic response of red sandstone soil under impact loads

  • Wang, Tong;Song, Zhanping;Yang, Jianyong;Wang, Junbao;Zhang, Xuegang
    • Geomechanics and Engineering
    • /
    • 제17권4호
    • /
    • pp.393-403
    • /
    • 2019
  • The cycling impact test of red sandstone soil under different axial pressure and different impact loads are conducted to reveal the mechanical properties and energy consumption mechanism of red sandstone soil with static-dynamic coupling loading. The results show that: Under the action of different axial pressure and different impact loads, the peak stress of the specimen increases, and then tends to be stable with the times of impact. With the increase of impact times, the specific energy absorption value of the red sandstone soil specimen is increased first and then gentle development trend. When the impact loads are certain, the larger the axial pressure is, the smaller the peak value of energy absorption, which indicates that the energy utilization rate is not high under the condition of large axial pressure. Through the analysis of energy utilization, it is found that the smaller the impact load, the higher the energy utilization rate. The greater the axial pressure, the lower the energy utilization rate. when the axial pressure is large, the impact loads corresponding to the maximum values of reflectivity, transmissivity and absorptivity are the same. The relationship between reflectivity and transmissivity is negatively correlated.

자기공명영상 검사 시 환자정보의 체중을 낮게 입력하여 전자파흡수율을 감소시키는 대안의 오류 (Alternative Input Lower Weight Information Method Error to Reduce Specific Absorption Rate in MRI)

  • 최관우
    • 한국콘텐츠학회논문지
    • /
    • 제20권2호
    • /
    • pp.472-477
    • /
    • 2020
  • 본 연구는 자기공명영상 검사 시 전자파흡수율을 감소시키는 대안으로 환자정보의 체중을 낮게 입력하는 방법의 오류를 바로잡고자 하였다. 연구방법은 환자정보에 입력하는 체중에 따라 전자파흡수율이 변화되지 않는다는 사실을 증명하기 위해 50kg 팬텀을 코일 안에 위치시킨 후 입력 체중을 10kg에서부터 100kg 까지 10kg 단위로 변화시켜 기기에서 산출되는 전자파흡수율을 비교평가 하였다. 연구결과, T1 강조영상은 전자파 흡수율이 평균 0.2W/kg이었고 T2 강조영상은 평균 0.4W/kg이었으나, T1, T2 강조영상 모두 체중의 변화에 따른 전자파흡수율의 변화는 없었다. 결론적으로 검사 전 검사자가 입력하는 체중에 따라 전자파흡수율은 변화되지 않으므로, 환자정보 입력 시 체중을 낮게 입력하는 것은 전자파흡수율을 감소시키는 대안이 될 수 없다.

황토를 이용한 친환경 유공 흡음보드의 흡음특성 (Absorption Characteristics of Perforated Environment Friendly Sound Absorbing Board using Hwangto)

  • 김선우;박현구
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.3-8
    • /
    • 2011
  • Sound absorbing materials used for lightweight panels and interior material are mainly made of fibroid material such as glass wool or rock wool. However these fiber type sound absorbing materials have some problems such that sound absorption could be decreased as time goes by because of durability. In addition, dust scattering from fiber type material can cause another problem in health. In this point of view, this study aims to develop environment friendly sound absorbing material using Hwangto(so called loess or yellow soil), a traditional housing material. Hwangto is natural housing material in Korea and generally known for improving indoor air quality. Hwangto panel is made to construct on the floor, wall and ceiling, and expected that there is not enough absorption. Present study tried to develop environment friendly sound absorbing material that has high sound absorption performance with good environment performance in terms of air quality. Pore rate was designed to maximize the absorption in the specific frequency bands, and two kinds of backing space were applied in order to see the effect of backing space. As a result peak frequency that has maximum absorption is going high as the pore rate is increased. The backing space provides more absorption and makes the peak frequency down to low.

숭례문 기와의 물리적 특성 연구 (A Study of the Physical Properties of Sungnyemun Tile)

  • 정광용
    • 건축역사연구
    • /
    • 제20권1호
    • /
    • pp.23-39
    • /
    • 2011
  • The Sungnyemun roofing tiles were twice disassembled for maintenance work, in 1963 and 1997, and modern tiles were applied in 1997. However, besides differing in visual appearance, the modern tiles had distinctly different physical properties. A study has been carried out on 22 different tiles, including original Sungnyemun tiles, modern tiles applied during maintenance, traditional tiles made by tile-makers, and others, to examine their physical properties, such as bending strength, frost resistance, absorption, whole-rock magnetic susceptibility, chromaticity, differential thermal analysis, and other characteristics. Since the method of making modern tiles involves compressing clay in a vacuum, modern tiles showed relatively greater bending strength and specific gravity, while Sungnyemun tiles and those made by tile-makers, in comparison, demonstrated less bending strength and specific gravity owing to their production method of 'treading,' in which clay is mixed by having someone tread upon it repeatedly. Over time, the absorption rate of the original tile used for Sungyemun gradually decreased from 21% to 14.7%; traditional tiles from tile-makers showed absorption rates of 17%, while the absorption rate of modern tiles was just 1%, which is significantly low. As for frost resistance, Sungnyemun tiles and traditional tiles from tile-makers showed cracking and exfoliation after being subjected to testing 4 or 5 times, while slight cracking was seen on the surface for modern tiles after 1ngy, or 3 times. In other words, no significant difference from influence by frost was found. According to the results of differential thermal analysis, the plastic temperature was shown to have been no less than 1, $on^{\circ}C$ for all types of tile, and cristobalite was measuredthrough XRD analysis from a Sungnyemun female tile applied during maintenance in 1963, which appeared to have been plasticized at between $1,200^{\circ}C{\sim}1,300^{\circ}C$. Based on these research results on the physical properties of tiles from the Sungnyemun roof, a fundamental production method for tiles to be applied in the restoration of Sungnyemun has been identified.

콘크리트 재료의 흡수상태에 따른 물리적 변화에 관한 기초적 연구 (A Fundamental Study on Physical Change According to Absorption of Materials for Concrete)

  • 한다희;박희곤;정근호;이영도;정상진;정재영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.45-48
    • /
    • 2003
  • Most concrete is recently made of an aggregate which is properly absorbed, and carried in it in order to do capability at every fields. We have been close to demand new capability of high flowing and enduring for specific concretes. That is difficult to cope with claiming the efficiency on deterioration from lack of a high quality aggregate. Therefore, For solving the problems we apply to a packing method for using dried materials. That is to say it is a kind of making into an instant. In this study, There is a purpose to present fundamental data, comparing and analyzing a phenomenon about aggregate's absorption following the rate of adding water, for using existing materials.

  • PDF

EBG 구조를 사용한 전자파 인체 흡수 차단 휴대폰 케이스 (Phone Case using the EBG Structure for Reducing SAR)

  • 오도영;유형석
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.78-81
    • /
    • 2015
  • This paper investigates the performance of phone case with different permittivities like plastic, urethane and silicone. Then, we put an electromagnetic band gap (EBG) structure in phone case to reduce the specific absorption rate (SAR). In order to design the phone case, a loop antenna for PCS 1900 band was used. The phone case consists of a hairpin-like EBG structure that is more compact than other EBG structures. The SEMCAD X fdtd simulation results showed that, this proposed phone case can reduce SAR by 13 - 30% at similar power that is radiated by the antenna. This phone case can be used in future to reduce the SAR from mobile phones.

RF 전자기장 생체 영향 실험에서 통계적 방법을 통한 전자기장 노출 불확실성 분석 (The analysis of RF dosimetric uncertainties by using statistical method at in-vivo and in-vitro experiments)

  • 최성호;김남
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.74-78
    • /
    • 2003
  • This paper shows the dosimetric uncertainties of electromagnetic field at in-vivo and in-vitro experiments. For more accurate consequences of these researches, we have tried to find out any correlations among output power, power density and specific absorption rate(SAR) with the results of in-vivo, in-vitro tests and SAR reports of cellular phone and PDA. In the case of in-vivo tests, the power density has close statistical correlations with SAR value and in the event of in-vitro tests, the output power has considerable statistical correlations with SAR containing duty factor. On the other hand, we found that both power density and output power don't have any close correlations with SAR. And, we obtained fitted regression form among frequency, power density and SAR containing duty factor through multiple linear regression analysis.

  • PDF

휴대 단말기의 SAR 저감법에 관한 연구 (A Study on SAR Reduction Method for Mobile Handsets)

  • 황재호
    • 한국정보통신학회논문지
    • /
    • 제9권4호
    • /
    • pp.833-838
    • /
    • 2005
  • 본 논문은 무선통신용 휴대 단말기를 설계하는데 있어 인체 전자파 흡수율(SAR)을 저감시키는-방법을 제안하고 있다. 휴대 단말기의 안테나로부터 방사되는 전자파에너지는 안테나 뿐 아니라 휴대 단말기 기구의 특정부분에 밀집되는데 이와 같은 표면 전계강도는 인체 두부에 영향을 미쳐 SAR값의 증가 요소로 작용한다. 따라서 이를 감소시키는 방법으로는 표면전계가 밀집되지 않도록 기구를 설계할 필요가 있으며, 이에 대한 설계 방안을 제시한다. 인체를 포함한 단말기의 해석은 유한요소법(FEM)을 사용하였으며, 본 저감법를 적용한 경우 SAR첨두치의 약 $50\;\%$를 저감하는 효과가 나타났다.

SAR Variation by EMI Paint Distribution on Front Case of Mobile Handsets

  • Lee Won Kew;Son Ji Myoung;Yang Woon Geun
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.339-342
    • /
    • 2004
  • In this paper, we investigated methods to reduce SAR(Specific Absorption Rate) value with EMI(Electromagnetic Interference) paint distribution on front case of mobile handset. Simulations for several different EMI patterns were carried out. For the purpose of modeling, we used 3 dimensional CAD(Computer Aided Design) program, `Pro-engineering'. SAR simulation was done with SEMCAD, simulation platform for electromagnetic compatibility antenna design and dosimetry. In order to distinguish the individual pieces and to enable an assignment of the different material properties, each subfile was imported separately. In simulation, folding angle was set to $142^{\circ}.$ If we vary folding angle, different SAR value will be obtained. Among the tested EMI paint patterns, the hairpin pattern showed the best performance, i.e. the decrease efficiency of $16.5\%$ and horizontal-direction zigzag pattern showed the decrease efficiency of $12.2\%$ when we set the completely removed pattern as reference.

  • PDF

자기공명영상시스템에서의 의료용 리드선의 전자기적 호환 연구 (Electromagnetic Compatibility Study of a Medical Lead for MRI Systems)

  • 유형석
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2019-2022
    • /
    • 2016
  • In the presence of an electrically conducting medical lead, radio frequency (RF) coils in magnetic resonance imaging (MRI) systems may concentrate the RF energy and cause tissue heating near the lead. A novel design for a medical lead to reduce this heating by introducing pins in the lead is presented. Peak 10 g specific absorption rate (SAR) in heart tissue, an indicator of heating, was calculated and compared for both conventional (Medtronic) lead design and our proposed design. Remcom XFdtd software was used to calculate the peak SAR distribution in a realistic model of the human body. The model contained a medical lead that was exposed to RF magnetic fields at 64 MHz (1.5 T), 128 MHz (3 T) and 300 MHz (7 T) using a model of an MR birdcage body coil. The proposed design of adding pins to the medical lead can significantly reduce the heating from different MRI systems.