• Title/Summary/Keyword: Special medical equipment

Search Result 79, Processing Time 0.031 seconds

A study on improving the performance of special ambulances (특수구급차 성능 개선을 위한 조사 연구)

  • Yoon, Byoung-Gil;Yang, Hyun-Mo;Kim, Gyoung-Yong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.26 no.1
    • /
    • pp.87-99
    • /
    • 2022
  • Purpose: This study aimed to provide basic data for the improvement of the standards related to the performance improvement of the firefighting equipment standards for special ambulances. Methods: Among the domestic firefighting equipment standards, the special ambulance standard was compared with the NFPA 1917 standard for the United States automobile ambulance 2019 and European Union European standard EN 1789 medical vehicle and its equipment, a road ambulance. Results: Anti-skid performance based on indoor noise standards, performance standards for interior lights, seat belt warning device, child car seat fixing device, safety handle, auxiliary footrest, and flooring materials should be supplemented. Conclusion: It is necessary to strengthen the production and performance standards for improvement to a level corresponding to the national standards, such as the United States and European Union.

Study on Compatibility between ISM Equipment and WLAN (ISM 기기와 무선랜의 양립성에 관한 연구)

  • Shim, Yong-Sup;Lee, Il-Kyoo;Cho, Ju-Phil;Min, Kyoung-Il
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.1
    • /
    • pp.63-67
    • /
    • 2011
  • This paper analyzes the interference effect of ISM(Industrial Scientific Medical) equipment on WLAN in order to protect WLAN in interference environment which WLAN Station is close to ISM equipment. CISPR(International Special Committee on Radio Interference) radiation limit standard was used for interfering power of ISM equipment. Then, MCL(Minimum Coupling Loss) which is for the worst case and MC(Monte Carlo) which is based on statistic interference probability are used to get protection distance. As a result, the protection distance of 105 m was calculated by using MCL for the worst case. And, the protection distance of 17 m was calculated by using MC for statistic analysis.

Experiment and verification of the O-ring test (O-링 테스트의 실험적 검토)

  • 최기훈;김영탁;여인철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.64-67
    • /
    • 2000
  • It is usual that the medical examination of human body need special knowledpe and equipments. Thus we have to spend Lime and energy on going to special place such as hospital where doctors and equipments are. Which often cause missing a good chance af medical treatment as well as giving us inconvenience. However many simple and convenient equipments were developed for checking our health conditions recently. O-ring test is accepted a3 one of useful methods to examine our heallb conditions. Also the test is recognized as a uscful means to judge, withoul any special equipment and medical knowledge, if some medical substances or foods are beneficial or harmful to our health. However, the judgement may be mcorrect because it depend on doctor's subjective point of view.In this study, we developed an automatic O-ring t a r mach~ne which enable us to check our health conditions objectively and quantitatively. The validity of the idea to develope the machine was proved by experiments.

  • PDF

Compatibility between ISM Equipment and WiBro Service at 2.3 GHz band (2.3 GHz 대역의 ISM 기기와 WiBro 서비스의 양립성 분석)

  • Shim, Yong-Sup;Lee, Il-Kyoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2011
  • This paper calculates protection distance to protect WiBro service from ISM(Industrial Scientific Medical) equipment which is used in the same frequency with WiBro. We analyze with a scenario that WiBro receiver is closed to ISM equipment which has interfering power of CISPR(International Special Committee on Radio Interference) 11 limit. As a result, the protection distance of 14 m was calculated by using MCL (Minimum Coupling Loss) for the worst case. And, the protection distance of 10 m was calculated to meet 5 % interference probability below by using MC(Monte Carlo) for statistic analysis in case of a interferer.

Problems of the Act and Subordinate Statutes Related to the Regulation of Radiation Safety for Diagnosis (진단용 방사선 안전관리 법령의 문제점에 관한 연구)

  • Lim, Chang-Seon
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.2
    • /
    • pp.97-118
    • /
    • 2022
  • The use of diagnostic radiation in medical institutions is rapidly increasing. Accordingly, the collective effective dose is on the rise every year. Therefore, it is necessary to reduce the radiation exposure of the person undergoing the radiation examination as low as reasonably achievable. And we must establish a legal system to perform the safe management of radiation for diagnosis efficiently. In this way, I went over the problems of the Act and Subordinate Statutes regarding radiation safety management for diagnosis. As a result, the main contents are as follows. First, in the 「Medical Service Act」, there is no basis for the Safety Inspection Institute of Radiation and Radiation Exposure Measuring Institutes. And there are no provisions concerning delegation of administrative disposition. Therefore, it is necessary to secure legal justification by providing the basis for the Safety Inspection Institute of Radiation along with Radiation Exposure Measuring Institutes and the basis for administrative dispositions against these institutions in the 「Medical Service Act」. Second, the 「Rules on the Installation and Operation of Special Medical Equipment 」 should be integrated with the 「Rules on the Safety Management of Radiation Generators for Diagnostics」 to unify administrative procedures such as reporting for radiation special medical equipment for diagnosis. Third, in the case of violating the diagnostic radiation safety management standards in the 「Rules on the Safety Management of Radiation Generators for Diagnostics」, it is necessary to supplement the insufficient sanctions such as administrative disposition. Fourth, regulating diagnostic radiation and therapeutic radiation used in medical institutions with the dual legal system of the 「Medical Act」 and the 「Nuclear Safety Act」 is not efficient in the safety management of diagnostic radiation. Therefore, it is necessary to uniformly regulate diagnostic radiation and all medical radiation, including therapeutic radiation and nuclear medicine, in the 「Medical Service Act」 system.

The Study on the Perceptions of Radiological Technologist in Medical Imaging Equipment Used by the Oriental Doctor (한의사의 의료영상장비 사용에 대한 방사선사의 인식도)

  • Choi, Jae-Ho;Kang, Gi-Bong;Kim, Sang-Hyun;Kim, Tae-Hee;Kim, Gyoo-Hyung;Lee, Mi-Hwa;Ahn, Jung-Seong;Hong, Seong-Wan;Lee, Jae-Seok;Kwon, Ick-Su;Park, Jae-Yoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.109-120
    • /
    • 2017
  • In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20~30s, neutral in the 40~50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future.

A Study on the Architectural Planning of the X-ray Unit in General Hospital (종합병원 일반 및 특수촬영유니트의 건축계획에 관한 연구)

  • Youn, Woo-Young;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2006
  • Planning for the space of the Media Medical Department requires the details about the efficiency of the equipment and the operation in professional sector. For that, as designing, it is necessary to keep communicating with the experts on the technology and the officials from the company producing the equipment. One of the common concerns is not only how to insure enough room for the future extension and the upgrade of the equipment, as concerning the scale of the hospital, but the plan to cover movie cameras. As technology has been developed, despite the fact that machinery tend to be small, it can be possible to require continuously about the concerns of the scale because the camera taking body-picture tend to be much bigger and more complicated than before. Currently used diagnostic media techniques are divided by the method and the feature of the equipment such as Diagnostic X-ray, Ultrasound, CT, MRI, Angiography. The general and special photographing units which are used more than the other diagnostic parts, must be planned not for experiencing any inconvenience and unnecessary risks for the patients and must accept technical requirements. Also, it must be designed not to be seen as a clinic zone, as concerning the psychological stability of the patients. However, study of the general and special photographing units among the domestic general hospitals is insufficient. Also, as there is shortage of the material considering the development of the equipment, when planning, it's involving a lot of difficulties. Thus, this study has got a purpose on giving the basic material which is essential for further study, as suggesting the planning guidelines and the alternative plans for the general and special photographing units in a general hospital.

  • PDF

Study on the Application of Artificial Intelligence Model for CT Quality Control (CT 정도관리를 위한 인공지능 모델 적용에 관한 연구)

  • Ho Seong Hwang;Dong Hyun Kim;Ho Chul Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.182-189
    • /
    • 2023
  • CT is a medical device that acquires medical images based on Attenuation coefficient of human organs related to X-rays. In addition, using this theory, it can acquire sagittal and coronal planes and 3D images of the human body. Then, CT is essential device for universal diagnostic test. But Exposure of CT scan is so high that it is regulated and managed with special medical equipment. As the special medical equipment, CT must implement quality control. In detail of quality control, Spatial resolution of existing phantom imaging tests, Contrast resolution and clinical image evaluation are qualitative tests. These tests are not objective, so the reliability of the CT undermine trust. Therefore, by applying an artificial intelligence classification model, we wanted to confirm the possibility of quantitative evaluation of the qualitative evaluation part of the phantom test. We used intelligence classification models (VGG19, DenseNet201, EfficientNet B2, inception_resnet_v2, ResNet50V2, and Xception). And the fine-tuning process used for learning was additionally performed. As a result, in all classification models, the accuracy of spatial resolution was 0.9562 or higher, the precision was 0.9535, the recall was 1, the loss value was 0.1774, and the learning time was from a maximum of 14 minutes to a minimum of 8 minutes and 10 seconds. Through the experimental results, it was concluded that the artificial intelligence model can be applied to CT implements quality control in spatial resolution and contrast resolution.

Use of Home Nursing Therapy and Need of Home Care Equipments (가정간호환자의 치료적 간호서비스 제공과 의료기구 사용 및 요구도)

  • Ryu, Ho-Shin;Park, Chai-Soon;Kim, In-A;Kwon, Young-Dae;Kang, Sung-Wook
    • Research in Community and Public Health Nursing
    • /
    • v.19 no.2
    • /
    • pp.157-166
    • /
    • 2008
  • This study was conducted with whole home care nurses nationwide to provide secondary analyzed data to understand on their usage of medical equipments and their need of them for a month. This study found that treatments given by home care nurses were nelaton catheterization, bladder washing/urethral washing, newborn care, exchange and care for nasogastric tube and suction in that order of frequency. Second, instruments and equipments used for home care were reported to be stethoscope, patient monitor, blood pressure measuring equipment, air flotation mattresses, beds for patients, mattresses, suctioning device sets, enteral feeding equipment and dressing set in that oder of frequency. Moreover, need assessment of medical instruments and equipments showed renal dialysis was most needed and patient monitor, blood pressure measuring equipment, enteral feeding equipment, solution and other supplies for renal dialysis and beds for patient were necessary in that order. In conclusion, the results of this study investigating special treatments and medical instruments and equipments used for home care patients and analyzing patients' need, were expected to be useful for expansion of application of long-term care insurance for the elderly and health insurance as well as for quality control of home care and development of medial instruments and equipments used at home.

  • PDF

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.