• 제목/요약/키워드: Special hospital

검색결과 780건 처리시간 0.027초

간호교육 철학정립 및 교육과정 개발을 위한 기초조사 (A Preliminary Study on Setting Philosophy and Curriculum Development in Nursing Education)

  • 정연강;김윤회;양광희;한경자;한상임
    • 대한간호학회지
    • /
    • 제18권2호
    • /
    • pp.162-188
    • /
    • 1988
  • The purpose of this study is to guide the direction of the Korean nursing education to analysize ⑴ the philosophy and objectives ⑵ curriculum, and ⑶ educational environment. This analysis is based on the data from 50 nursing schools (14 4-year colleges and 35 3-year colleges) The survey was conducted from Dec. 1986 through Jan. 1987 by mail. 1) Educational philosophy and objectives 10 4-year colleges and 8 3-year college program have curricular philosoph. Most popular curricular philosophies are human beings, health, nursing, nursology, nursing education, nurses role in the present and in the future. 10 nursing schools mentioned that human being is the subject to interact with : environment physically, mentally and socially. 2 schools mentioned that health is the state of functioning well physically, mentally and socially. 13 schools mentioned that the nursing is the dynamic act to maintain and to promote the highest possible level of health. 4 schools mentioned that the nursology is an applied science. 4 schools mentioned that nursing education is the process to induce the behavioural changes based on the individual ability. There is different opinion about the nurses' role between 4-year college and 3-year college. In the responses from 4-year colleges they focus on the leadership in effective changes, self-regulating and self-determining responsibilities, applying the new technology, continuing education, and participation in research to further nursing knowledge. In the responses from 3-year colleges, they focus on the education in college, primary health care nursing, direct care provider and public health education. Among 50 respondents 40 schools have educational goals which can be divided into two categories. One is to establish the moral and the other is to develop the professionalism. 2) Curriculm The analsis of curriculum is only based on the data from the 4-year colleges because the most of 3-year colleges follow the curriculum guideline set by the Ministry of Education. a) Comparison of the credits in cultural subject and in nursing major. The average required credit for graduation is 154.6 and the median credit is the range of 140-149. The average credit of cultural subjects is 43.4. In detail, the average number of credit of required course and elective courses are 24.1 and 19.3 respectively. The average credit for major subject is 111.2. In detail, the average credit for required courses and electives course are 100.9 and 10.4 respectively. In 5 colleges, students are offered even on elective course b) Comparison of the credit by class. The average earned credits are as follows : 41.1 in freshman, 400 in sophormore 38.3 in junior and 32.4 in senior. Cultural subjects are studied in early phases. c) Comparison of the compulsory and elective cultural subject by institute. The range of credit is 7-43 in compulsory cultural subjects and there are lot of differences among institutions. While all respondents require liberal arts as compulsary subjects, few respondents lists social science, natural science and behavioral science as required subjects. Social science-related subjects are frequently chosen as cultural subjects d) Distribution of creditsin cultural subjects by institute. The liberal art subjects are taught in 20 institute. English and physical education courses are taught in all instituions. The social science subjects are taught in 15 colleges and the basic Psycology and the Basic sociology are the most popular subjects. The natural science subjects are taught in 7 colleges and Biology and Chemistry are the most popular subjects among them. e) Distribution of credits in major basic courses by institute. Most of the institutes select Anatomy, Microbiology, Physiology, biochemistry and Pathology as basic major courses. f) Comparison of the required and elective courses for nursing major by institutions. Subjects and credit ranges in major are varing by institute. More than half of the respondents select the following subjects as required major subjects. (1) Adults Health Nursing and Practice (19.5 credits) (2) Mother and Child Care and Practice (8.9 credits) (3) Community Health Care and Practice (8.5 credits) (4) Psychiatric Nursing Care and Practice (8.1 credits) (5) Nursing Management and Practice (3.9 credits) (6) Fundamental of Nursing, Nursing Research and Health Assessment and Practice. Three institutions select Introduction to nursing, Rehabilitation Nursing, School Nursing, Public Health Nursing, Nursing English, Communication, Human Development as electives in nursing major. 3) Educational environment a) Nursing institution There are forty-three 3-year colleges and seventeen 4-year colleges and 81.4% of which are private b) Number of students and faculty 19.2% of the students are in 4-year colleges and 80.8% of the students are in 3-year colleges. In 4-year colleges, the number of nursing faculty members is in the other of assistant professor, instructor and professor. In 3-year colleges, the orderiis lecturer, associate professor, full time instructor and assistant professor. In 4-year colleges, 18.8 students are allocated per nursing faculty and in 3-year colleges, 33.1 students are allocated per nursing faculty. c) Clinical practices 66.7% of the 4-year colleges practice over 1201 hours in clinic and 28.5% of 3-year colleges practice over 1201 hours in clinic. In 4-year colleges, 11.5 students are allocated per nursing faculty and in 3-year colleges,17 students are allocated per nursing faculty The survey shows no difference in the procedure between 4-year colleges and 3-year colleges but 3-year colleges choose the more variety practicing site such as special hospital and community health clinic. d) Audiovisual facilities The survey shows a lot of difference in audiovisual facilities among institution and 3-year colleges are less equipped than 4-year colleges.

  • PDF

최소 피부 절개술을 이용한 선천성 심장 질환 수술 (Minimal Skin Incision with Full Sternotomy for Congenital Heart Surgery)

  • 박충규;박표원;전태국;박계현;채헌
    • Journal of Chest Surgery
    • /
    • 제32권4호
    • /
    • pp.368-372
    • /
    • 1999
  • 배경: 선천성 심장 질환에서의 최소 피부 절개에 대한 보고는 매우 적다. 저자등은 수술상처를 최소화하면서 통상적인 수술수기 및 시야를 확보할 수 있는 방법을 고려하였다. 대상 및 방법: 저자등은 1997년 4월부터 1997년 9월까지 선천성 심장 질환 환자 40명을 대상으로 최소 피부 절개술과 정중 전 흉골 절단을 통해서 개심술을 시행하였다. 환자 질병 분포는 성인 환자가 5명(남:여=1:4)이며 이중, 심방 중격 결손증 3명, 심실 중격 결손증 1명, 부분 심내막상 결손증 1명이었고, 소아 35명(남:여=17:18)에서는 심방 중격 결손증 4명, 심실 중격 결손증 30명, 발살바 동맥류 1명이었다. 정중 피부 절개는 흉골 두번째 늑간하부에서 검상돌기 1~2cm상방까지 실시하였다. 흉골 하부 절단에는 일반 전기톱을, 흉골 상부 절단에는 특수 전기톱을 피부 밑에 삽입하여 전장의 흉골을 절단하였다. 그리고, 흉골 견인은 좌우 & 상하 양방향에 2개의 견인기를 각각 직각으로 거치하여 수술시야를 확보하였다. 결과: 흉골길이대비 피부절개의 길이는, 성인에서는 55.0$\pm$3.5%로 절개길이가 평균 12cm(10~13.5cm)였고, 소아에서는 63.1$\pm$3.9%로 평균 7.3cm(5.2~11cm)였다. 모든 증례에서 체외 순환시 필요한 동정맥 삽관을 추가적인 서혜부 피부 절개 없이 직접 대동맥 및 상하공 대정맥에 시행할 수 있었으며 좌심방벤트관은 필요시 삽입하였다. 전 례에서 수술사망이나 합병증은 발생하지 않았으며, 최소 피부 절개술에 따른 창상 감염 및 피부 괴사, 혈종 형성, 출혈에 의한 합병증은 없었다. 결론: 이상의 결과로 최소 피부 절개술과 정중 전 흉골 절개를 이용한 선천성 심장 질환 수술은, 통상적인 체외 심폐 순환을 할 수 있으며, 외관상 미용의 효과가 뚜렷하였고, 다양한 선천성 심질환에서 안전하고 효과적으로 사용될 수 있다고 판단된다.

  • PDF

ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구 (A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom)

  • 홍동희;정홍량;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.241-247
    • /
    • 2006
  • 최근 유방 영상 검사는 의료영상저장전송시스템(Picture Archiving and Communication System, PACS)의 도입과 특수의료장비에 관한 정도관리 실시로 인해 Computed Radiography(CR)과 Digital Radiography(DR)에 관한 관심도와 이용도가 증가하고 있는 추세이다. 본 연구는 유방영상검사에 이용되고 있는 각 시스템별 검출기의 영상 화질을 정도관리 시 사용되는 ACR 팬텀을 이용하여 비교 분석하였다. 평가 방법은 심리적인 방법으로 ACR 팬텀을 이용한 영상의 수치 값을 SPSS 통계프로그램을 이용하여 유의성과 신뢰도를 분석한 결과는 다음과 같다. 1. Fiber에서는 Screen-Film인 경우 3.9점, CR($50\;{\mu}m$)인 경우 4.2점, CR($100\;{\mu}m$)인 경우 3.2점, DR인 경우 4.2점을 얻어 CR($50\;{\mu}m$), DR, Screen-Film, CR($100\;{\mu}m$)순으로 높은 점수를 받았다(P<0.05). 2. Calcification은 Screen-Film인 경우 2.7점, CR($50\;{\mu}m$)인 경우 2.5점, CR($100\;{\mu}m$)인 경우 2.0점, DR인 경우 2.9점을 얻어 DR, Screen-Film, CR($50\;{\mu}m$), CR($100\;{\mu}m$) 순으로 높은 점수를 받았다(0.025(P<0.05). 3. Mass는 Screen-Film인 경우 3.8점, CR($50\;{\mu}m$)인 경우 3.8점, CR($100\;{\mu}m$)인 경우 3.6점, DR인 경우 4.5점을 얻어 DR, CR($50\;{\mu}m$), Screen-Film, CR($100\;{\mu}m$) 순으로 높은 점수를 받았다(P<0.1). 4. 합계점수 평가는 Screen-Film인 경우 10.4점, CR($50\;{\mu}m$)인 경우 10.6점, CR($100\;{\mu}m$)인 경우 8.7점, DR인 경우 11.3점을 얻어 DR, CR($50\;{\mu}m$), Screen-Film, CR($100\;{\mu}m$) 순으로 높은 점수를 받았다. 이상의 결과는 DR, Screen-Film시스템이 CR($100\;{\mu}m$)에 비해 화질이 우수하다는 것을 알 수 있다. 하지만 DR은 소자에 의한 불안정성, Screen-Film은 artifact에 의한 화질 저하 등 단점을 가지고 있으며, 화질 저하가 문제였던 CR시스템 중 Dual-Side방식의 CR($50\;{\mu}m$)을 사용한 경우에는 Screen-Film 시스템과 차이가 없는 것으로 나타났다. 향후 방사선 영상검사가 디지털화 되는 추세이므로 유방영상검사도 각 시스템의 발전과 보완이 필요할 것으로 사료된다.

  • PDF

소변 유기산 분석 8년의 정리 -탠덤매스(Tandem mass spectrometry)를 이용한 신생아 선별검사 도입 전후의 비교- (8 Years Report of Urine Organic Acid Analysis - Comparison before and after Introduction of Neonatal Screening Test using Tandem Mass Spectrometry -)

  • 안석민;신우철;정한빈;서영준;정활림;윤종형;배은주;이홍진
    • 대한유전성대사질환학회지
    • /
    • 제18권1호
    • /
    • pp.1-12
    • /
    • 2018
  • 목적: 유기산 대사이상 질환은 신경학적 증상과 증후를 포함하여 다양한 임상증상으로 나타날 수 있으며 때로는 생명을 위협할 수 있는 급성 악화로 발현될 수 있다. 따라서 이환된 환자들의 예후는 조기 진단과 치료에 의해 좌우된다. 탠덤매스검사의 도입 후 본원에 의뢰된 검체들을 분석하여 유기산 대사이상 질환의 진단율의 변화 및 연령별 분포와 임상양상을 알아보기 위해 본 연구를 시행하였다. 방법: 2007년 1월부터 2015년 9월까지 약 8년 9개월간 전국에 있는 대학병원에서 의뢰된 2,794례의 검체들을 이용하여 소변 유기산검사를 실시하였고 임상증상과 성별 및 연령군별 분포를 분석하여 정리하였다. 불확실한 결과를 보였던 환자들은 24시간 이상의 고단백 식사 후와 24시간 이상의 단백질 제한식사 후에 소변 유기산 분석을 재시행 하였다. 결과: 총 20가지 질환, 626례의 환자들이 진단되었는데, 사립체 질환이 482례로 가장 많이 진단되었고 그 뒤를 이어 케톤분해이상질환군 67례, 3-히드록시이소부티르산뇨증 32례, EPEMA 증후군 8례, 3-메틸크로토닐 글리신뇨증 7례, 글루타르산뇨증 II형 6례와 I형 4례, 메틸말론산뇨증, 이소발레린산뇨증, 중쇄 acyl-CoA 탈수소효소 결핍증이 각 3례 등이 진단되었다. 결론: 탠덤매스를 이용한 신생아 선별검사가 점차 보편화되고 의료환경의 변화로 인해, 이전의 보고와 비교했을 때 본 연구 기간동안의 유기산 대사이상 질환의 진단율은 다소 감소하였다. 유기산 대사이상 질환들은 다양한 증상들이 나타나고 종종 생명을 위협하는 상태로 발현되는 경우가 많다. 조기 진단과 처치를 통해 이런 급성 악화의 발현을 예방할 수 있기 때문에 진료현장에서 비특이적인 증상 및 신경학적 장애를 보이는 환자를 진료할 때 주의가 필요하다고 할 수 있겠다.

  • PDF

간호원의 의사소통방법이 정신병환자 반응에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Excellences of Nurses′ Communication Method upon Psychiatric Patient′s Response.)

  • 이평숙
    • 대한간호학회지
    • /
    • 제4권2호
    • /
    • pp.78-92
    • /
    • 1974
  • It is the purpose of this study to make clear the way in which people can lead a more desirable human life, that is, to ascertain the method of achieving therapeutic change through transaction between nurses and psychiatric patients. The various problems proposed by th9 above-stated aims of study can be shown, such as: What kind of influences does the method of a nurse′s communication have upon the response of psychiatric patients? 1) What are the general methods of communication used by the nurses? 2) Are there any differences between the control group and experimental group in the patients′ "Child" response? 3) Are there any differences between the control group and experimental group in the Patients "Adult" response? 4) What is the most desirable method of communication for therapeutic change in the patients? In an effort to solve the above questions this study attempted and managed to draw a random sampling of 200 patients being accommodated in the National Mental Hospital by dividing them into two groups, experimental groups and control groups, and recording the transactions between nurses and patients. In the course of carrying,: out this study, the experimental group was interviewed by the nurses specially trained In the P.A.C theory. and the control group interviewed at random by the nurses with no special training in communication. Further, the communication between nurses and patients in a free, relaxed atmosphere was allowed only for 15 minutes, whereupon the nurses were requested to make process-recording according to her memory of nurse patient transaction. The process-recording which recorded a series ol transactions between the nurses and the patients was analyzed according to Berne and Harris′transactional Analysis Standard. Through this standard, the writer of this study examined the significance of difference to compare the transactions brought forth between the experimental group and the control group. The following is a summary of the study which the writer of this thesis undertook. Hypothesis to The method of communication which the nurses usually apply to the patients will be higher in "Parent" than in "Adult". The communication which the nurses carried out in the control group turned out to be not significant between "Adult" and "Parent" Accordingly hypothesis 1. carne to be rejected. Hypothesis 2. The patients "Adult" response will be higher in the experimental group than in the control group. According to the result of a CR examination, as the communication showed a significant difference on P〈.01 level′ hypothesis 2 became affirmative. Hypothesis 3. The patients′"Child" response will be higher in the control group than in the experimental group. Hypothesis 3 proved affirmative since it showed an significant degree on P〈.01 level according to the result of a CR examination. Hypothesis 4 "Adult" response of the patient will be higher in frequency by nurses′"Adult" stimulus than nurse′s "Parent" stimulus Chi-square examination revealed significant difference on P〈.05 level. Hypo. 4 is affirmed. The following conclusions are drawn out based on the result of this study. 1) The generally used method of communication stimulus used by nurses for patients proved to be "Adult" and "Parent" in similar proportion. 2) The group in which the nurses could increase the patients "Adult" response proved to be higher in the experimental group than in the control group. Therefore, the communication (or stimulus) which has been applied in the experimental group can be said to be possible method of achieving therapeutic change. 3) Since the patients′"Child" response were higher in the control group than in the experimental group the communication method used In the control group was suggested as the less agreeable method of achieving therapeutic change than that used in the experimental Group. 4) "Adult" response of patient was elicited in significantly greater percentage when the "Adult" stimulus was used by the nurse. Therefore the most desirable method of-communication to give therapeutic change definitely was shown to be the "Adult" stimulus. Recommendations for further studies are as follows: 1) Studies on nurses′role perception in nurse-patient relationships. 2) Studies on patients′response to the method of communication used by nurses according to variables such as sex, social status, educational background, state of health. 3) Application of T.A, method to various groups of patients. 4) Study of various methods to improve student skill in use of process recording.

  • PDF

복부 둔상 및 유강장기 손상에 있어서 초기 나선형 복부전산화 단층촬영의 진단적 가치 (Impact of Initial Helical Abdominal Computed Tomography on the Diagnosis of Hollow Viscus Injury and Blunt Abdominal Traumare)

  • 조영덕;홍윤식;이성우;최성혁;윤영훈;임성익;장익진;백승원
    • Journal of Trauma and Injury
    • /
    • 제21권1호
    • /
    • pp.28-35
    • /
    • 2008
  • Purpose: This study was conducted to examine the clinical significance IV-contrasted helical abdomen computed tomography (CT) as a diagnostic screening tool to evaluate hollow viscus injury in blunt abdominal trauma patients. Methods: This is a retrospective study encompassing 108 patients, presenting to Korea University Medical Center (KUMC) Emergency Department (ED) from January 2007 to December 2007, with an initial CT finding suggestive of intra-abdominal injury. An initial non-enhanced abdomen CT was taken, followed by an enhanced CT with intravenous contrast. Patients' demographic data, as well as the mechanisms of injury, were inquired upon and obtained, initial diagnosis, as dictated by specialized radiologists, were added to post-operational (post-OP) findings and to additional CT findings acquired during their hospital stays, and all were combined to arrive at final diagnosis. Initial CT findings were further compared with the final diagnosis, yielding values for sensitivity, specificity, and accuracy, as well as positive and negative predictive values. Patients were further divided into two groups, namely, those that underwent operational intervention and those that did not. The initial CT findings of each group were subsequently compared and analyzed. Results: Initial CT scans revealed abnormal findings in a total of 212 cases - solid organ injuries being the most common finding, as was observed in 97 cases. Free fluid accumulation was evident in another 69 cases. Based on the CT findings, 77 cases (71.3%) were initially diagnosed as having a solid organ injury, 20 cases (18.5%) as having a combined (solid organ + hollow viscus) injury, and 11 cases (10.2%), as having an isolated hollow viscus injury. The final diagnosis however, were somewhat different, with only 67 cases (62.0%) attributed to solid organ injury, 31 cases (28.7%) to combined injury (solid + hollow), and 10 cases (9.3%) to hollow viscus injury. The sensitivity (CI 95%) of the initial helical CT in diagnosing hollow viscus injury was 75.6%, and its specificity was 100%. The accuracy in diagnosing hollow viscus injury was also meaningfully lower compared to that in diagnosis of solid organ injury. Among patients initially diagnosed with solid organ injuries, 10 patients (2 from follow-up CT and 8 from post-OP finding) turned out to have combined injuries. A total of 38 patients underwent an operation, and the proportion of initial CT findings suggesting free air, mesenteric hematoma or bowel wall thickening turned out to be significantly higher in the operation group. Conclusion: Abdominal CT was a meaningful screening test for hollow viscus injury, but the sensitivity of abdominal CT was significantly lower in detecting hollow viscus injury as compared to solid organ injury. This calls for special consideration and careful observation by the ED physicians when dealing with cases of blunt abdominal trauma.

유전자패널 시퀀싱으로 진단된 성인형 very-long-chain acyl-coenzyme A dehydrogenase (VLCAD) 결핍증 증례 (A Case of Late-onset Episodic Myopathic Form with Intermittent Rhabdomyolysis of Very-long-chain acyl-coenzyme A Dehydrogenase (VLCAD) Deficiency Diagnosed by Multigene Panel Sequencing)

  • 손영배;안선현;장자현;이새미
    • 대한유전성대사질환학회지
    • /
    • 제19권1호
    • /
    • pp.20-25
    • /
    • 2019
  • Very-long-chain acyl-CoA dehydrogenase (VLCAD) 결핍증은 상염색체 열성으로 유전되는 유전성대사질환으로 미토콘드리아에서 장쇄지방산의 산화 장애이다. VLCAD 결핍증의 임상증상은 중증도 및 발현 시기에 따라 심각한 심장 이상을 동반하는 신생아기 발현형, 소아기 발현형, 지발형의 세 가지로 분류할 수 있다. 저자들은 혈장 아실카르니틴 분석과 유전자패널 염기서열분석 방법으로 확진된 성인기 발현형 VLCAD 결핍증 1례를 경험하였기에 보고하고자 한다. 34세 여자가 반복되는 근육통증과 간헐적 횡문근융해증의 병력을 주소로 내원하였다. 환자는 12세에 처음으로 운동 후 횡문근융해증으로 급성 신부전이 발생하여 혈액 투석을 받고 회복하였다. 이후 환자는 장시간의 운동이나 금식 후에 반복적으로 근육통증과 횡문근융해증이 발생하였다. 내원 시 신체 검진과 신경학적 검진은 정상이었다. 내원시 혈장 AST/ALT, Creatinine kinase (CK)는 약간 상승해있었으나, 이전 의무기록에 의하면 횡문근융해증이 있을 당시 AST/ALT, CK는 매우 상승하였다. 환자의 병력을 토대로 지방산대사장애 의심하에 감별진단을 위하여, 유전자 패널 염기서열 분석과 혈장 아실카르니틴 분석을 시행하였다. 혈장 아실카르니틴 분석결과 C14:1 ($1.453{\mu}mol/L$; 참고치, 0.044-0.285)와 C14:2 ($0.323{\mu}mol/L$; 0.032-0.301)가 증가였고, C14 ($0.841{\mu}mol/L$; 0.065-0.920)는 높은 정상이었다. 유전자패널 염기서열분석에서는 ACADVL 유전자에서 두 개의 병원성변이가 이형접합으로 발견되었으며, 이는 Sanger 염기서열 분석으로 확진되었다: c.[1202G>A(;)1349G>A] (p.[(Ser401Asn)(;)(Arg 450His)]). 환자는 생화학적, 유전학적 검사결과를 바탕으로 지발형 VLCAD 결핍증으로 확진되어 저지방식이와 급성 대사장애를 예방하기 위한 영양 교육을 받았다. 경증의 지발형 지방산 대사장애는 임상증상과 생화학적 검사 이상이 간헐적으로 발생하기 때문에 진단이 어렵다. 유전자패널 염기서열 분석은 지방산대사 장애와 같이 임상증상과 원인 유전자 이상이 다양한 대사 이상질환에서 유용한 진단법이 될 수 있다.

  • PDF

소아청소년의 전신마취 하 치과 치료의 추세변화 및 치과 영역 중증 장애 유무에 따른 전신마취 재시행 양상에 대한 연구 (Trends of Dental Treatment under General Anesthesia and Patterns of Repeated General Anesthesia in Children and Adolescents with Severe Disabilities)

  • 이아름;김현태;송지수;신터전;현홍근;김정욱;장기택;김영재
    • 대한소아치과학회지
    • /
    • 제50권1호
    • /
    • pp.75-88
    • /
    • 2023
  • 이 후향적 연구는 2011년 1월부터 2020년 12월까지 서울대학교 치과병원 소아치과에서 시행된 전신마취 하 치과 치료의 추세 변화를 분석하고 치과 영역 중증 장애 여부에 따른 전신마취 재시행 양상을 비교해보고자 하였다. 1,719명의 환자에게 1,857건의 전신마취 하 치과 치료가 시행되었으며 평균 연령은 5.1세였고 남자가 59.3%였으며 ASA 2등급 이상인 환자가 52.9%, 치과 영역 중증 장애 환자는 26.8%였다. 연구 기간 동안 전신마취 시행 건수는 지속적으로 증가하였으며, 6.6%의 환자가 2회 이상의 전신마취 하 치과 치료를 받았고 10년 동안 전신마취 재시행률은 7.4%였다. ASA 2등급 이상인 환자(p < 0.0001)와 치과 영역 중증 장애 환자(p < 0.0001)에게서 전신마취 재시행의 가능성이 높았으며, 치과 영역 중증 장애 환자가 전신마취를 시행받은 시기의 연령이 더 높게 나타났다(p < 0.0001). 치과 영역 중증 장애 환자에게 첫 전신마취와 두 번째 전신마취에서 모두 영구치의 수복 치료(p = 0.002, p < 0.0001)가 더 많이 시행되었다. 최근 10년간 소아치과 영역에서 전신마취의 사용이 증가하고 있으며 치과 영역 중증 장애를 가진 소아청소년 환자의 전신마취 재시행을 줄이기 위한 정기 검진과 구강 위생 관리를 통한 예방이 중요하다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF