• 제목/요약/키워드: Special hospital

검색결과 783건 처리시간 0.03초

Intraoral HIV-associated Burkitt's lymphoma: a rare case report with special emphasis on differential diagnosis

  • Kamat, Mamata;Datar, Uma;Kanitkar, Sampada;Byakodi, Sanjay
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권4호
    • /
    • pp.225-229
    • /
    • 2019
  • Individuals with human immunodeficiency virus (HIV) infection present with unique intraoral manifestations of various neoplasms. Intraoral HIV-associated Burkitt's lymphoma is a rare presentation, especially in patients of Indian origin and may present as an initial sign of HIV. The objective of this paper is to report a rare case of Burkitt's lymphoma in an HIV-positive Indian patient along with a special emphasis on differential diagnosis. A 30-year-old Indian female presented with a solitary, well-defined, exophytic mass extending anteroposteriorly and buccolingually from the 35th to 38th regions with no evidence of intraosseous extension. An incisional biopsy was performed, and histopathology showed sheets of neoplastic lymphoid cells with numerous tingible body macrophages with clear cytoplasm, presenting a starry sky appearance, suggesting a diagnosis of BL. The tumor cells were positive for CD10, CD20, c-myc, and Epstein-Barr virus, with a nearly 100% Ki-67 proliferative index. The patient tested positive for HIV. This report indicates the importance of immunohistochemical analysis to differentiate Burkitt's lymphoma from other similar lesions like diffuse large B-cell lymphoma. Thorough knowledge of the clinical presentation, etiopathogenesis, histopathology, and immunoprofile of intraoral HIV-associated Burkitt's lymphoma is essential among clinicians and pathologists.

Heat or radiofrequency plasma glow discharge treatment of a titanium alloy stimulates osteoblast gene expression in the MC3T3 osteoprogenitor cell line

  • Rapuano, Bruce E.;Hackshaw, Kyle;Macdonald, Daniel E.
    • Journal of Periodontal and Implant Science
    • /
    • 제42권3호
    • /
    • pp.95-104
    • /
    • 2012
  • Purpose: The purpose of this study was to determine whether increasing the Ti6Al4V surface oxide negative charge through heat ($600^{\circ}C$) or radiofrequency plasma glow discharge (RFGD) pretreatment, with or without a subsequent coating with fibronectin, stimulated osteoblast gene marker expression in the MC3T3 osteoprogenitor cell line. Methods: Quantitative real-time polymerase chain reaction was used to measure changes over time in the mRNA levels for osteoblast gene markers, including alkaline phosphatase, bone sialoprotein, collagen type I (${\alpha}1$), osteocalcin, osteopontin and parathyroid hormone-related peptide (PTH-rP), and the osteoblast precursor genes Runx2 and osterix. Results: Osteoprogenitors began to differentiate earlier on disks that were pretreated with heat or RFGD. The pretreatments increased gene marker expression in the absence of a fibronectin coating. However, pretreatments increased osteoblast gene expression for fibronectin-coated disks more than uncoated disks, suggesting a surface oxide-mediated specific enhancement of fibronectin's bioactivity. Heat pretreatment had greater effects on the mRNA expression of genes for PTH-rP, alkaline phosphatase and osteocalcin while RFGD pretreatment had greater effects on osteopontin and bone sialoprotein gene expression. Conclusions: The results suggest that heat and RFGD pretreatments of the Ti6Al4V surface oxide stimulated osteoblast differentiation through an enhancement of (a) coated fibronectin's bioactivity and (b) the bioactivities of other serum or matrix proteins. The quantitative differences in the effects of the two pretreatments on osteoblast gene marker expression may have arisen from the unique physico-chemical characteristics of each resultant oxide surface. Therefore, engineering the Ti6Al4V surface oxide to become more negatively charged can be used to accelerate osteoblast differentiation through fibronectin-dependent and independent mechanisms.

종합병원 일반 및 특수촬영유니트의 건축계획에 관한 연구 (A Study on the Architectural Planning of the X-ray Unit in General Hospital)

  • 윤우용;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제12권3호
    • /
    • pp.27-34
    • /
    • 2006
  • Planning for the space of the Media Medical Department requires the details about the efficiency of the equipment and the operation in professional sector. For that, as designing, it is necessary to keep communicating with the experts on the technology and the officials from the company producing the equipment. One of the common concerns is not only how to insure enough room for the future extension and the upgrade of the equipment, as concerning the scale of the hospital, but the plan to cover movie cameras. As technology has been developed, despite the fact that machinery tend to be small, it can be possible to require continuously about the concerns of the scale because the camera taking body-picture tend to be much bigger and more complicated than before. Currently used diagnostic media techniques are divided by the method and the feature of the equipment such as Diagnostic X-ray, Ultrasound, CT, MRI, Angiography. The general and special photographing units which are used more than the other diagnostic parts, must be planned not for experiencing any inconvenience and unnecessary risks for the patients and must accept technical requirements. Also, it must be designed not to be seen as a clinic zone, as concerning the psychological stability of the patients. However, study of the general and special photographing units among the domestic general hospitals is insufficient. Also, as there is shortage of the material considering the development of the equipment, when planning, it's involving a lot of difficulties. Thus, this study has got a purpose on giving the basic material which is essential for further study, as suggesting the planning guidelines and the alternative plans for the general and special photographing units in a general hospital.

  • PDF

전문병원의 역량과 경쟁전략이 성과에 미치는 영향과 경영환경의 조절효과 (The Effect of Competence and Competitive Strategy on Performance in Special Hospitals and the Moderating Effect of the Business Environment)

  • 류황건;장원혁
    • 보건의료산업학회지
    • /
    • 제9권4호
    • /
    • pp.13-32
    • /
    • 2015
  • Objectives : This study explored ways to identify factors that have competitive advantages and achieve high performance by investigating the influence of competence and competitive strategy on the performance and moderating effect of the business environment within special hospitals. Methods : A total of 80 specialized hospitals participated in the study. A multiple regression analysis was carried out by configuring sub-factors for each factor, and a hierarchical regression analysis was conducted with interaction terms as independent variables. Results : Among the competence factors of special hospitals, the competence of hospital staff and business management had a significantly positive (+) effect on the internal performance, and the competence of the marketing management had a significantly positive (+) effect on the external performance. Conclusions : The findings of this study suggest that in the rapidly changing health care environment, special hospitals should select and focus on competitive strategies and competency factors required to ensure competitiveness and achieve high performance, and based on this, need to seek integrated strategic management measures.

종합병원의 환기설비 사례 연구 (A Case Study on the Ventilation System of the General hospital)

  • 정종림
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.187-194
    • /
    • 2004
  • In many other buildings, hospital is very important because of its function and purpose. A proper building service systems including heating, cooling, ventilation and plumbing systems is required in hospial. Besides, a special systems like medical gas, vacuum cleaning systems are required to prevent contamination as well as cure a patient in hospital. Ventilation is very important method to keep the indoor pressure and clean class. There are some specific rooms to consider clean class and indoor pressure in the general hospital. In this article, specific rooms were set to operating room, laboratory, ICU, isolation unit, and sterilizer room. In this case study, design factors of ventilation system, including air changes of OA and TA, indoor pressure, clean class, filter, and material of system, of specific rooms in hospital were proposed through a literature research and a design examples review.

Tetralogy of Fallot with Subarterial Ventricular Septal Defect

  • Kim, Sam-Hyun;Seo, Dong-Man;Park, Pyo-Won;Song, Meong-Gun;Park, Young-Kwan;Lee, Young-Kyoon
    • Journal of Chest Surgery
    • /
    • 제21권1호
    • /
    • pp.82-86
    • /
    • 1988
  • Tetralogy of Fallot with subarterial ventricular septal defect is known to be relatively common in the Far East. Among the 140 consecutive patients who underwent repair for tetralogy, 15 [10,7@] had this variant form of tetralogy. Though the degree of pulmonic stenosis seems only mild or moderately severe because of the absence of infundibular septum and relatively large size of pulmonary arteries in this type of tetralogy, it has a special surgical implication that a patch widening of the right ventriculotomy is necessary in every case to avoid the postoperative subpulmonic stenosis. A morphological and surgical features of tetralogy with subarterial VSD are presented.

  • PDF

노인전문병원의 병동부문 공간구성에 관한 연구 (A study on the Spacial Composition for Ward in Geriatric Hospital)

  • 윤성중;이특구
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제7권2호
    • /
    • pp.59-69
    • /
    • 2001
  • The purpose of this study is to provide a basic data for architectural planning on the wards and special quality of physical remedy spaces of geriatrics hospital. This research, to analyse dependency degree of inpatients in geriatric hospital, shows relativeness between remedy space and wards, and to show behavior of each patients reaction to there space. Result of interviewed inpatients who were sorted by age, sex, dependency degree, and days in hospital, suitable space programming is to need for physical and mental state. On the bases of survey and analysis, the basic data for planning and design the hospital for the elderly with dementia has been proposed.

  • PDF

종합병원 간호사들의 피로수준 및 관련요인 (Fatigue Symptoms and Its Related Factors among General Hospital Nurses)

  • 박안숙;권인선;조영채
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.2164-2172
    • /
    • 2009
  • 본 연구는 종합병원 간호사들을 대상으로 특수부서 근무 간호사(수술실, 중환자실, 응급실)와 병동 근무 간호사의 피로수준을 비교하고 그의 관련요인을 파악하기 위해 2008년 8월에 대전광역시에 소재하고 있는 400병상 이상의 3개 종합병원에 근무하는 여성 간호사 393명을 대상으로 자기기입식설문조사를 실시하였다. 연구결과 평균 피로점수는 특수부서 근무 간호사가 병동 근무 간호사보다 높았다. 다중회귀분석결과 피로수준에 영향을 미치는 관련 요인으로는 특수부서 근무 간호사의 경우 주관적 건강 상태, 연령, 간호직 생활에 대한 만족도가 주요 설명변수로 선정되었으며, 병동 근무자의 경우는 주관적 건강 상태, 평소 수면 시간, 교대 근무, 간호직 생활에 대한 만족도가 주요설명변수로 선정되었다. 위와 같은 결과를 볼 때, 특수부서 근무 간호사는 병동근무간호사에 비해 피로수준이 높은 것을 알 수 있으며, 특수부서 근무간호사와 병동 근무간호사의 피로에 영향을 미치는 관련 요인에도 차이가 있음을 알 수 있다.

일선 간호관리자의 자기 효능감에 관한 연구 (A Study of first-line nurse manager's self-efficacy)

  • 고명숙
    • 간호행정학회지
    • /
    • 제6권1호
    • /
    • pp.97-107
    • /
    • 2000
  • In human societies, there are various organizations which are unique and have different roles. Among them, hospital organization are much more complex than other organizations because of their multitude of professional groups each with its own goals. To achieve its purposes, hospital should manage each professional group effectively. Hospital nursing organizations are the core positions in hospitals for patient care. Therefore nursing organizations have have efficient nurse managers to lead nurses for their own purposes. First- line nurse managers have special tasks for patients and nurses, which include to motivating, managing communicating with the people. So they should have high self-efficacy, which is the belief that one can successfully perform the behaviors in question. Self-Efficacy of first line nurse managers that asked them for leading their staff, and their tasks, is essential to bring about self-realization of staff nurses through motivation and job satisfaction, taking advantage of sound surrounding which is able to operate her staff nurses in order to function efficiently. But there were few studies on the topic in a hospital setting. This study was designed to measure first-line nurse managers' self-efficacy. The subjects for this Study were 167 first-line nurse managers randomly selected from 18 university hospitals in Korea. The Self-Efficacy was measured using 'The general self-efficacy scale' developed by Sherer and Maddux(1982). The data were collected through questionnaires and analysed using SAS program, frequencies, percentages and Pearson' correlation coefficients. The results of this study were as follows : 1. The average of first- line nurse managers' self- efficacy was 66.7. 2. The correlation between first-line nurse managers' self- efficacy and general characteristics(age, education, career) was not significant. From the above findings, this study can suggest the following : 1. Repeat studies are needed in various hospital settings. 2. First-line nurse managers must be trained with special programs for each nursing organizations' purposes.

  • PDF

Role of Catheter's Position for Final Results in Intrathecal Drug Delivery. Analysis Based on CSF Dynamics and Specific Drugs Profiles

  • De Andres, Jose;Perotti, Luciano;Villanueva, Vicente;Asensio Samper, Juan Marcos;Fabregat-Cid, Gustavo
    • The Korean Journal of Pain
    • /
    • 제26권4호
    • /
    • pp.336-346
    • /
    • 2013
  • Intrathecal drug delivery is an effective and safe option for the treatment of chronic pathology refractory to conventional pain therapies. Typical intrathecal administered drugs are opioids, baclofen, local anesthetics and adjuvant medications. Although knowledge about mechanisms of action of intrathecal drugs are every day more clear many doubt remain respect the correct location of intrathecal catheter in order to achieve the best therapeutic result. We analyze the factors that can affect drug distribution within the cerebrospinal fluid. Three categories of variables were identified: drug features, cerebrospinal fluid (CSF) dynamics and patients features. First category includes physicochemical properties and pharmacological features of intrathecal administered drugs with special attention to drug lipophilicity. In the second category, the variables in CSF flow, are considered that can modify the drug distribution within the CSF with special attention to the new theories of liquoral circulation. Last category try to explain inter-individual difference in baclofen response with difference that are specific for each patients such as the anatomical area to treat, patient posture or reaction to inflammatory stimulus. We conclude that a comprehensive evaluation of the patients, including imaging techniques to study the anatomy and physiology of intrathecal environment and CSF dynamics, could become essential in the future to the purpose of optimize the clinical outcome of intrathecal therapy.